Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹16.8 L+₹12,604.90 (0.75%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹16.8 L+₹12,606 (0.76%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹18.4 L+₹1.7 L (10.3%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹21.7 L+₹5.1 L (30.3%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L5 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
12 Aug 2021, 6:00 pmClosed
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT
REPAIR/REPLACEMENT OF SECURITY LIGHT, LED FLOOD LIGHTS ALONGWITH DAMAGE LT CABLES AND ITS CONNECTING ITEMS AT AJAY GARRISON, BANA, KHETARPAL ENCLAVE AND CHAIN SINGH ENCLAVE UNDER AGE E/M OF GE (SOUTH) MAMUN
2021_MES_459608_1
GE(S)/M-23/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE SOUTH MAMUN
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE SOUTH MAMUN
₹40,000
Yes
13 Oct 2021
14 Jul 2021
14 Aug 2021
14 Jul 2021
12 Aug 2021
30 Jul 2021
Amount
Taking down street light fitting or flood light fitting any type and rating from poles, walls or any other indicated situation/location after disconnecting electrically. seggregating serviceable and unservicable fittings. Keeping aside serviceable for reuse, refix after repair at same location or any other and removing unserviceable from site complete all as specified and directed.
Maintenance of street light fitting on pole / wall at any height, cleaning of complete fitting / fixture, removing carbon from connection, tighting of bulb etc without replacing any part and making street light functional complete all as specified and directed.
S&F in replacement of HPSV lamp 70W tubular clear lamp on location including disconnecting and taking out of old unsv lamp any type any make from light fitting complete all as specified and directed.
S&F in replacement" of HPSV lamp 150 W tubular clear lamp on location including disconnecting and taking out of old unsv lamp any type any make from light fitting complete all as specified and directed.
S&F in replacement of energy efficient tube rod T-5 24 watt 230V to street light fittings at location including taking out old one complete all as specified and directed.
S&F in replacement of electronic ballast 2x24 Watt suitable for T-5 fitting having pf above 0.9 to street light fittings at location including making connection and testing including taking out old one complete all as specified and directed.
S&F in replacement of heavy duty VPIT open construction copper ballast 150W HPSV/ MH for street light or flood light fitting including disconnecting and taking out of old unsv ballast any type any make from light fitting and making connection and testing complete all as specified and directed.
S&F in replacement of heavy duty VPIT open construction copper ballast 70W HPSV/ MH for street light or flood light fitting including disconnecting and taking out of old unsv ballast any type any make from light fitting and making connection and testing complete all as specified and directed.
S&F in replacement of resin/Powder filled dry type ignitor elctronic 230V suitable 70 watt HPSV/MH lamp fittings for street light or flood light fitting including disconnecting and taking out of old unsv Ignitor any type any make from light fitting and making connection and testing complete all as specified and directed.
S&F in replacement of resin/Powder filled dry type ignitor elctronic 230V suitable 150 watt HPSV/MH lamp fittings for street light or flood light fitting including disconnecting and taking out of old unsv Ignitor any type any make from light fitting and making connection and testing complete all as specified and directed.
S&F in replacement of porcelain Lamp holder suitable for 150 watt HPSV/MH lamp with base E40, including disconnecting and taking out of old unsv holder any type any make from light fitting and making connection and testing complete all as specified and directed.
S&F in replacement of porcelain Lamp holder suitable for 70 watt HPSV/MH lamp with base E27, including disconnecting and taking out of old unsv holder any type any make from light fitting and making connection and testing complete all as specified and directed.
S&F in replacement of bracket for street light fitting made out of 40mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light firtting bracket with one coat of red oxide primer, one under coat and one finishing coat with aluminium paint including taking out old one complete all as specified and directed.
S&F in replacement of 60W LED Street Light luminaire, made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Note for srl item No 14 above 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70. 4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W. 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type. 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. 11. CA No. shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintenance required, if any can be carried out from Top cover.
S&F in replacement of old unserviceable aluminium conductor cable single core PVC insulated and sheathed aluminium conductor cable of size 2.5 sqmm down through the existing pole/GI pipe bracket including taking out old one complete all as specified and directed.
S&F in replacement of toughened clear glass cover rectangular/ circular suitable for flood light fittings/ Street light fitting any type 70 to 150 watts as per sample all as required including taking out old one complete all as specified and directed.
S&F in replacement of PVC conduit heavy duty 25 mm bore cut to size and fixed along the pole for cable protection all as required at site including taking out old one complete all as specified and directed.
S&F in replacement of cable of size 10 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminiun conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspended with galavnised steel wire, including taking out old one complete all as specified and directed.
S&F in replacement of cable of size 6 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminiun conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspended with galavnised steel wire, including taking out old one complete all as specified and directed.
M&L for scraping of old paint from the steel tubular pole 9 Mtr height with out removing accessories and preparation of surfaces for repainting. Repainting the pole with one coat of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamel paint. Marking the pole number with black enamel paint over yellow circle of dia 100mm. Repainting the remaining pole and iron parts i.e 'U' clamps, channels etc above 1.5 mtr height by applying one coat of alumn paint, complete all as specified and directed
S&F in replacement of pole mounted street light factory fabricated junction box of size 300 x 160 x 250 mm mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet , including63A ,Three Phase four wire having four no.AL Bus Bar including 6A SP MCB. The box should have auto Door Lock facility with magnetic Lock having Sizehaving Size box fixed on pole using necerssary fixing arrangement such as clamps,nut,bolts and washer including taking down existing junction box of any description/type etc complete all as specified and directed.
S&F in replacement of XLPE insulated PVC sheathed heavy duty armoured cable 1100 volts grade with aluminium conductor of size 16 Sqmm 2 core laid in trenches/ and on wall/ poles including taking out old one complete all as specified and directed.
S&F in replacement of XLPE insulated PVC sheathed heavy duty armoured cable 1100 volts grade with aluminium conductor of size 16 Sqmm 4 core laid in trenches/ and on wall/ poles including taking out old one complete all as specified and directed.
S&F in replacement of XLPE insulated PVC sheathed heavy duty armoured cable 1100 volts grade with aluminium conductor of size 50 Sqmm 3.5 core laid in trenches/ and on wall/ poles including taking out old one complete all as specified and directed.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L for dry clean fine river sand as in sand cushioning to underground cable 23cm thick (8cm before laying & 15cm after laying cable) including punning down of sand layer complete all as specified and directed. Note :- Punned thickness shall only be measured and paid.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
S&F in replacement of GI tubing light grade 40 mm bore cut to size and fixed along the pole for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts , washers etc all as required at site including taking out old one complete all as specified and directed.
S&F in replacement of GI tubing light grade 100 mm bore cut to size and fixed along the pole for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts , washers etc all as required at site including taking out old one complete all as specified and directed.
Supply, installation, connecting electrically and testing of street light panel box complete with and including Astroonomical timer ,contactor rating 65 Amp, MCB 63 A TPN complete for mounted made out of CRCA sheet 1.6 mm thick, powder coated, having provision for Astronomical Timer, Contactor, Toggle switch, SP MCBs and MCCBs etc. having self closing door lock complete with fixing clamps or mounting arrangement all as required at site, specified or directed including taking out existing U/S street light switch any type and size complete all as specified and directed.
S&F in replacement of MCB single pole 240 volts, C series, any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables including taking out old one complete all as specified and directed.
S&F in replacement of MCB single pole 240 volts, C series, any rating from 32 to 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables including taking out old one complete all as specified and directed.
Restretching aluminium conductor or GI wire on existing over head lines (running on 11 Mtrs pole) without removing including unbinding from insulator and rebinding to insulator using aluninium binding wire, connections of incoming and out going cables, binding with spacers where required, complete all as specified and directed. (Note ;- For measurement length of set of 3 conductors incl GI wire / Cradle or guarding wire shall be taken as one sapn ).
Supplying, jointing and connecting "as in repairs" cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
S&F in replacement of electronic driver of approved make suitable for LED fittings of cap upto 60watts any type and make, complete all as specified and directed.
S&F in replacement of electronic LED security light driver ISI approved company made as Crompton, Havells, Wipro suitable for LED fittings of cap upto 60 to 120watts any type and make, including taking out old one complete all as specified and directed.
M&L for scraping of old paint from the steel tubular pole 9 Mtr height with out removing accessories and preparation of surfaces for repainting. Repainting the pole with one coat of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamel paint. Marking the pole number with black enamel paint over yellow circle of dia 100mm. Repainting the remaining pole and iron parts i.e 'U' clamps, channels etc above 1.5 mtr height by applying two coat of alumn paint, incl. writting letters or figures (Block, Roman, Italic or Indian) S/L Pole No and location code n. exc. 30cm high, sto, commas, short lines, dashes, hypens, brackets etc complete all as specified and directed.
Power Electronic Engineers
M/S Vijay Punj Constructions
M/S HIMANSHU BUILDERS
Vijay Kumar Contractor and Engineers
KULBHUSHAN AGGARWAL
Bidder Name
KULBHUSHAN AGGARWAL
Vijay Kumar Contractor and Engineers
M/S Vijay Punj Constructions
Power Electronic Engineers
M/S SHAKTI ELECTRIC WORKS
M/S HIMANSHU BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .