Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.7 LAccepted-AOC | L-1 | Accepted-AOC L-1 bidder and offered rate is reasonable and acceptable | |
| 2 | Rejected-Technical | - | Rejected-Technical L-3 bidder, document of L-3 bidder not scrutinised as bid of L-1 bidder found accetable technically and financially | |
| 3 | Rejected-Technical HOUSE NO 345 SHREE RAM ELECTRICALS SONIPAT ROAD LAWANSPUR SONIPAT HARYANA 131021 | SONIPAT | HARYANA | 131021 | - | Rejected-Technical L-2 bidder, document of L-2 bidder not scrutinised as bid of L-1 bidder found accetable technically and financially |
Tender Value
₹6.1 L
EMD Value
₹7,700
Closing Date
26 Mar 2024, 5:00 pmClosed
Staff Officer(EnM)
Office of the GM, Piparwar Area, Post Bachra, Dist Chatra, Jharkhand
Separate Power Supply for Air Conditioners of different section of Panchwati Executive Hostel at Bachra under GM unit, Piparwar Area.
2024_CCL_305397_1
SO(EnM)/PPR/eNIT/23-24/112
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Bachra Township
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,700
2 May 2024
16 Mar 2024
27 Mar 2024
16 Mar 2024
26 Mar 2024
16 Mar 2024
16 Mar 2024 - 22 Mar 2024
Amount
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 125 mm X 60 mm deep
Providing and fixing of 400 A Bus Bar 3 feet size 36" x 18 " x 6 "
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.315 A TP&N
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 A
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Total impact of GST for the purpose of CTC
M/S AJAY KUMAR SINGH
SHREE RAM ELECTRICALS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .