Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
19 Dec 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMISSIONER
MUNICIPAL OFFICE KOTAGIRI
Construction of Public Toilet at Melanaihatty Under SBM Scheme in Kotagiri Municipality
2025_MAWS_629933_1
DMA/288-2/2025/SBM2
Open Tender
Civil Works
Works
30 days
KOTAGIRI
REGISTERED CONTRACTOR IN GOVT SECTOR
1 document required · 1 mandatory
₹1,770
Yes
₹15,000
Yes
8 Dec 2025
8 Dec 2025
20 Dec 2025
8 Dec 2025
19 Dec 2025
8 Dec 2025
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand, silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and completed, cleaning and levelling the site etc.,complete -
Supplying stacking and Filling in foundation and basement with excavated earth in layers of not more than 15 cm thick well rammed watered and compacted -1m3 etc., complete complying with standard specification.
Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation - Plinth Beam
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Nild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13cm dia spaced at not more than 75cm centre to centre etc. complete complying with the standard specificaiton. - For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
Providing and laying in position Standardised Concrete dlix M- 20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (I'l- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requirements of IS standards. - Upto Basement
Providing and laying in position Standardised Concrete Mix f4- 20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (N- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requirements of IS standards. - Ground Floor
Supply and fabrication of steel required for all RCC items of works involved in the schedule, cost of steel at site fabrication, labour charges for cleaning the rods straightening, cutting, bending, tying grills, including overlapping to the required length whenever necessary and placing the reinforcement in position as as per design given and specified in the drawings, including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc complete as per standard specification
Brick work In CM 1:5 mix using best country bricks of size 8 3/4 x 4 1/4 x 2 3/4' having 350kg/cm2 compressive strength and 15% or less water absorbentin the period of 24hours immersement and confirming to ISI specifications.and using the screened sand and all the materials should be approved by the competent technical authorities etc complete complying with standard specification--basement
Brick work in CN 1:5 (one cement & Five Crushed Stone Sand (I'l- Sand)) using II class ground moulded bricks of size 9" X43*’"X 23 ’” standard specification including finishing, curing, etc., complete complying with standard specification (Plasonry projections wherever necessary for obtaining required elevation shall be done without extra cost) -Super structure
Manufacturing and supplying and fixing of steel doors with the following specifications. MS angles of size 40x 40x 6mm at 3.5 Kg./m are used for the outer frame and MS angle of size 35x 35x 5mm at 2.6 Kg/m for the shutter frames. Stiffeners with 32x6mm at 1.5 Kg./m MS flat is provided as the lockroll of the door and welded intact of both ends to the shutter frame 18g CR sheets of best quality is laid as panel in the shutter frames 18x5mm at 0.7 Kg./m MS flat is welded over the 32x6mm at 1.50 Kg./m MS flat on the rear side of the door sandwitching the CR sheet for rigidity. Additional stiffeners with 18x5mm at 0.7 Kg./m MB flats are provided diagonally onthe rear side of the shutter 2 Nos. of hinges in case of single leaf and 4 nos. of hinges in case of double leaf shutters is provided. 6 Nos. of hold fasts 120mm length spilced at the ends are wolded to the outer frame of the door. Tower bolt 2 Nos. one at the top and the other at the bottom are provided.
Special ceiling plastering in all floors and finishing the exposed surface of RCC items of work such as slab, beam, sunshade, facia, canopy slab, staircase waist slab, landing slab etc., with cement mortar 1:3 (One cement and three plastering sand (P- Sand)) 10mm thick including hacking the surfaces and providing cement mortar nosing, beading for sunshade, staircase, step, landing slab etc., including neat finishing and curing etc., complete complying with standard specification and as directed by the departmental officers.
Plastering with cement mortar 1:5 (One cement and five plastering sand (P- Sand)) 12mm thick in all floors including cost and conveyance of all materials to site etc,compIete as per standard specifications
Plastering with cement mortar 1:4 (One cement and five plastering sand (P- Sand)) 20mm thick in all floors including cost and conveyance of all materials to site etc,compIete as per standard specifications
Paving the floor with palin/design (desin should be got approved by the departmental officers before purchase)Stain Free Nano Polish Vitrified Tiles(colour and shade as directed) of size 600 x 600 x 8mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement etc completecomplying with standard specification.
Dadooing walls with Glazed tiles of sizes 300mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed.
Supplying and fixing in position Cement based hydruali-cally pressed Anti-Skid tiles (pattern design) 20 mmthick in cement mortar 1:3- 20 mm thick & pointed with same colour of cement etc.,complete.
Painting external wall with two coats of best approved quality of Plastice Emultion Paint over a including One Coat of priming of Exterior Emulsion Paint - Water Based Primer (Liquid) primier over cement surface wall as dirceted by the departmental officers including cleaning preparing the surface etc,complete complying with standard specification.The cement paint should be got approved by the departmental officers before use on work
Supplying and fixing of RCC Jolly of size 45cm x60 cm including all materials and labour charges
Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with 'P' trap or 'S' trap confirming to IS:2556 - Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.35 MB
BOQ_753320.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .