SPECIAL REPAIR TO BLDG NO P1 AT PASTA LANE AND PROVISION OF 3 PHASE SUPPLY FOR HEAVY DUTY COMPRESSOR AT EASTERN HANGER AND SPECIAL REPAIR TO DRAINAGE NETWORK IN AND AROUND T72B HANGAR INCULDING ADMIN BUILDING AT INS SHIKRA UNDER GE (NW) NOFRA
2024_MES_667717_2
8299
Open Tender
Civil Works
Item Rate
270 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (NW) NOFRA
₹96,960
Yes
28 Oct 2024
1 Oct 2024
28 Oct 2024
1 Oct 2024
26 Oct 2024
9 Oct 2024
1 Oct 2024 - 2 Oct 2024
Amount
Taking down cement or cement lime plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles.
Material and labour for brick work with sub class "B" bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4), complete all as specified.
M&L for Chipping , removing carefullly concrete work by low impact hammer, breakar without damaging the structure & cleaning and disposal of debris out side the premises etc. complete as directed by Engineer-in-Charge. [Note : Hard concrete should not be removed by force.]
Material and labour for cleaning existing reinforcement with wire/rotary wire brush,making the surfaces free from loose material dirt etc, copmplete, applying two coats of alkaline rust converting primer FEOVERT or equivalent specification confirming to ASTM-B-117, on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating IPNET-RB complete all as specified and directed.
M&L for Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and directed.
Material & labour for carry out application of Bi-polar migratory corrosion inhibitor EPCO-KP-100/ Protectsil CIT/Ferogard 903 on concrete surface (this inhibitor shall have migratory kind of properly which permits the material to migrate to a virtual extent of 100 mm, through pores of concrete, inhibitor the corrosion and de-passivating the Electro-chemical reaction. It should have properly to attack as well as cathode, which is purely alkaline in nature (pH-9.5), So it has no carcinogen activity with concrete all as per manufacturer's instructions and directed.
Material & labour for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes. Works shall be carried out as under :- (i)Cleaning of holes.Clean the holes by air blower prior to fixing nozzles. (ii)Fixing of nozzles.Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for minimum 12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the crack with a liberal application of the epoxy putty.
Material & labour for Injecting of cement slurry grout, in the ratio 1:2 (1-cement 2-water) including super plasticizer (supercom-100) 250 ml/50 Kgs. Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 0.5 Kg/sqcm till the grout mix flow out from the nozzle indicating complete filling of grout in the holes drilled.
Material & labour for Injecting low viscosity MONOPOL (3-5 cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including mixing of material components (part A & B) in the required quantities as per manufacture`s instruction by weigh batching, Grouting maintain the pressure at exit(0.5 to 1.0 kg/cm2) by monitoring pressure gauge at exit grout the material through prefixed nozzles in the structural elements@100ml per nozzle Repeat the process for all the nozzles. (Beam, RCC wall and columns)
M&L Providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster confirming to ASTM-C-882-91 (Arizona slant shear test) to ensure bond between old concrete and new concrete complete all as per manufacturer's instructions and as directed by Engineer-in-Charge.
M&L for Building up the profile of structural member by using latex additives (MONOBOND) modified air cured mortar system (Polymer modified mortar/LW+) (1:5:15=1 monobond-5 cement -15 sand) -in damaged area in 30mm thickness including leveling profiling etc complete all as per manufacturer's instructions and as directed by Engineer-in-Charge.
M&L for Providing and applying jacketing around columns with Micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete. [Note :- Reinforcement shall be measured and paid separately rates quoted shall be inclusive of jacketing, formwork and micro concrete etc complete all as specified.]
M&L for rendering 15mm thick cement plaster in CM 1:4 on fair faces of brick work/concrete surfaces finished even and smooth without using extra cement by using WPC @2% by weight of cement.(Note-WPC shall be measured and paid seperately).
Material & labour for preparation of newly plastered wall surfaces and applying two coats of water proof paint over a coat wall primer complete all as specified and as per manufacturer's instruction.
M&L for rendering 15mm thick cement plaster in CM 1:6 on fair faces of brick work/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 10mm thick on fair faces of ceilings in CM (1:3) & rendering is to be finishing even & smooth without using extra cement., complete all as specified.
Material and labour for preparation of new plastered surface of wall and applying 2 coats of oil emuslion distemper over a coat of primer on 2 to 3 mm thick wall care putty all as specified and directed.
Material and labour for preparation of new plastered surface of ceiling and applying two coats of oil emuslion distemper over a coat of primer on 2 to 3 mm thick wall care putty all as specified and directed.
M&L for preparation of old plastered surface of ceiling and applying 2 coats of oil emuslion distemper over a coat of 2 to 3 mm thick wall care putty all as specified and directed.
M&L for preparation of old plastered surface of wall and applying 2 coats of oil emuslion distemper over a coat of primer over 2 to 3mm thick wall care putty all as specified and directed.
Material & labour for preparation of old plastered wall surfaces and applying two coats of water proof paint wall primer complete all as specified and as per manufacturer's instruction.
Supply and fix for MS framed works as in grills, railings, brackets for chajjas etc, conforming to FE-290 Gde E-165.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.
Supply and fix Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified.
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in benching, coping, cills steps, parapets, railings up to 60cm in height, water troughs and the like rounded or chamfered on edges including necessary form work complete all as specified.
Supply and fix 110 mm dia PVC (SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls / laid in trenches with and including fixing clips and taking down old pipe of any description/ size complete all as specified and directed..
Supply and fix in repairs 110 mm dia bore PVC (SWR) bends any radius
Dismantling of 100mm cast iron or reinforced concrete drain pipes, jointed in cement mortar, complete all as specified.
S&F 100 mm bore of sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall complete all as specified.
Dismantling of 75mm cast iron or reinforced concrete drain pipes, jointed in cement mortar, complete all as specified.
S&F 75mm bore of sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall complete all as specified.
M&L in repair 75mm cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) including grating jalli complete all as specified and as directed.
S&F 75mm sand cast CI Branch pieces (Tee), Single (equal), ordinary or inverted (spigot or socket type) or with parallel branches with ovel access door and jointed with neat cement paste to CI pipes fixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge.
S&F 100mm sand cast CI Branch pieces (Tee), Single (equal), ordinary or inverted (spigot or socket type) or with parallel branches with ovel access door and jointed with neat cement paste to CI pipes fixed to wall , complete all as specified.
S&F in repair 100mm CI ‘P’ or ‘S’ Traps jointed with neat cement paste fixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge.
S&F in repair cast iron cowl suitable for 75mm dia pipe , complete all as specified.
S&F in repair cast iron cowl suitable for 100mm dia pipe, complete all as specified.
S&F in repair stack clamps suitable for securing 100mm dia CI pipe made out of 40mm by 3mm flat iron and 8mm dia round iron stays Including bolts and nuts and securing ends of stays fixed to wall, complete all as specified.
S&F in repair stack clamps suitable for securing 75mm dia CI pipe made out of 40mm by 3mm flat iron and 8mm dia round iron stays Including bolts and nuts and securing ends of stays fixed to wall, complete all as specified.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing, complete all as specified.
Taking up or down 20mm bore steel tubing and connections,complete all as specified.
Taking up or down 25mm bore steel tubing and connections, complete all as specified.
Taking up or down 50mm bore steel tubing and connections, complete all as specified.
S&F 15mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified.
S&F 20mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors , complete all as specified.
S&F 25mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified.
S&F 50mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified.
S&F in repairs fancy type CP Pillar taps 15 mm dia, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure ,with long screwed shanks and fly-nuts , screwed for iron pipe and fixed complete all as specified and as directed.
S&F in repairs fancy type bib taps, chromium plated cast copper alloy 15mm bore with crutch handle, screwed down, & fixed complete all as specified and as directed.
S & F in repairs stop valve fancy type chromium plated screwed down, high presure with butterfly handle screwed both ends for pipe and fixed to pipe of 15mm dia bore complete all as specified and as directed.
S&F in repairs 15mm bore stop valves fancy type chromium plated with long shank and cup (concealed type) 15 mm dia screwed down, high pressure with crutch or butter fly handle, screwed both ends, complete all as specified and as directed.
S&F 20 mm bore Stop valves , fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed as in repairs.
S&F in repairs Vitreous China wash down water closet pan ( pedestal pattern), white including plastic water closet seat, black or white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device ,complete all as specified and as directed.
S&F in repair vitreous china squatting pan Orissa pattern long pan size 510 x 410 x 260 mm with CI trap 100mm with integral foot rest & fixing incl but (excluding flushing cistern and flush pipe) making good floor to match all as specified.
S&F as in repair Vitreous china wash basin counter type , white , flat back, size 550 x 400mm including brackets and 32mm waste cupling, complete all as specified.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and as directed.
S&F in repairs PVC valveless syphonic action type, flushing cistern Low level white, with inlet ball valve , float and handle 10 Ltr capacity including brackets complete all as specified and as directed.
S&F in repairs Flush pipe of Polyethylene of low or high density or PVC 32 mm dia. for low level cistern complete all as specified and as directed.
S&F in repairs Chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
S&F in repairs brass chroumium plated tubular towel rail 20mm dia, D type 600mm long between flanges, complete all as specified and as directed.
S&F in repairs low density polyethylene pipes (LDPE) of pressure rating 6 kg/cm2 fixed complete to walls, ceilings or in floors etc for outlet of washing machine/wash basin etc of 40 mm dia bore complete all as specified and as directed.
S&F 2000 lit capacity rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top ) hoisted and fixed position all specified in SSR Part-I, with and including 50mm dia ball valve, high pressure of PTMT, with epoxy coated aluminium rod & high density plastic ball, minimum weight 210gm, screwed for iron pipes and fixed; including disconnecting and dismantling/ taking down of existing old unserviceable water storage tank in roof, complete all as specified and directed by Engineer-in-Charge.
Demolition of Cement concrete in any description and in any position not other wise specifically provided on terrace of bldg (above 5th floor) directed by Engineer-in-Charge and removal of debris to out side MD land as per guidelines of BMC.
Material and labour for cement concrete 1:2:4 type B-2 (40mm graded stone aggregate) by using WPC @ 2% of weight of cement as in floor of RCC roof all as specified and directed. Note: (WPC shall be paid seperately)
Supply only Integral water proofing compound.
M&L for rendering 10mm thick cement plaster in cement Mortar 1:4 on concrete surfaces as on roof finished even and smooth without using extra cement complete all as specified and directed.
Material & labour for providing in repairs water proofing treatment with 4mm APP (Atactic polypropylene) modified polyester(bituminous) membrane reinforced of 3.5Kg/Sqm with non woven polyester mat of weight 160 gms/sqm as center core and without multiple layers of polyethylene, finished on top and bottom with 7 micron thick flammable polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane, after applying a coat of bituminous primer @ 0.25 Kg/Sqm over roof (An overlap of 100mm and 150mm shall be provided on sides and ends respectively) and applying two coats of aluminium paint on APP sheet complete all as specified and directed.
Material and labour for cement 1:2:4 type B-0 (12.5mm graded stone aggregate) as in roof kerbs and leveling course on RCC roof surfaces ( Terrace above 5th floor of bldg.) all as specified and directed.
Taking down chowkats or frames n exc 1.5 sqm each with shutters (without taking off shutters from the frame) , complete all as specified.
Taking down chowkats or frames exc 1.5 sqm each but n.exc 4 sqm with shutters (without taking off shutters from the frame)
S&F powder coated (colour of coating as directed) aluminium (minimum 25 micron thickness of coating) of various section as required/suitable for doors, window & partion/Ventilator (sliding /or openable type)etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like jointing cleats, glazing clips, rubber neoprene packing. anodised aluminium snap beading screws etc. rubber beading, clips locking arrangement, handle, sealant etc all as specified and as directed.
Supply & fix aluminium anodised grill (minimum thickness of anodising 15 micron) with and including suitable aluminium anodized 'E'/'H' section frame as required with aluminium rebated/screwed attachment complete all as specified and directed complete all as specified and directed. [Note:- Aluminium grill shall be of Deco grill of approved make as per Design No DG 102, 7.50mm x 6.0mm and weight shall not be less than 3.131Kg/Sqm or approved design.]
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples all as specified and directed.
M&L 2nd class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
S&F 35mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides one face covered with decorative face veneer with lipping/ frame to match complete all as specified and directed.
S&F 2nd class hard wood 35 mm thick, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauze etc all as specified and directed.
S&F for aluminium anodized barrel tower bolts 200mm of extruded section and fixed.
S&F 200 mm size aluminium alloy handles, cast type anodised, ISI marked all as specified.
S&F 100mm butt hinges medium weight, stainless steel and fixed.
S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
M&L for Preparation of new wooden surafces & applying two coats of synthetic enemal paint over a coat of pink primer, complete all as specified.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar, complete all as directed.
M&L for machine cut cudappah stone slab 50mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
M&L, for machine cut kota stone slab flooring 20-25mm thick over cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
M&L, for machine cut kota stone slab flooring 20-25mm thick in riser / treads of steps in single piece, skirting, dado and pillar laid over cement screed and jointed withover cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
M&L Granite (of any type) work (table rubbed and polished) 20mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite., and nosing /rounding to edges of stone slabs one edge,all as specified and directed .
M&L for Preparation of new steel surafces & apply two coats of synthetic enemal paint over a coat of red oxide, complete all as specified.
Dismantling floor hearth or wall tiling including cement mortar bedding and removing serviceble tiles to store and rubbish off the permises.complete all as specified & as directed.
M & L Non - skid Ceramic tiles coloured 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6), complete all as specified.
M&L, Glazed ceramic tiles coloured of size 300X 200X 7mm laid on vertical surface such as dado/skirting over cement mortar backing coat, set jointed in neat cement slurry and pointed in white or coloured cement including 10mm thick backing coat in CM 1:4 , complete all as specified.
M&L, Glazed ceramic tiles coloured of size 300X 450X 7mm laid on vertical surface such as dado/skirting over cement mortar backing coat, set jointed in neat cement slurry and pointed in white or coloured cement including 10mm thick backing coat in CM 1:4 , complete all as specified.
M&L for Plain cement concrete 1:3:6 type C-2 using 20 mm graded stone aggregate as in floor or paving 75 mm thick and finished even and smooth without using extra cement, as in plinth protection all as specified
S&F in repairs fancy type drapery rods, powder coated aluminium of 20-25mm size incl brackets all as specified.
Supply and fix as in repairs false ceiling with powder coated exposed GI grip suspension system (E-grip T-2430 or equivalent load carrying capacity with mid span deflection not exceeding. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross tee 1200mm/600mm long wall angle. The main runners to be placed @ 1200mm, the cross tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm from a modular grid of 1200mm x 600m. Additinoal cross tees of 600mm shall be placed perpedicular to the cross tee 1200mm long to finally form a grip of 600mm x 600mm. Grip of modular size 600mm x 600mm shall be supported by 6mm dia GI wire from purlins / soffit with and including 6mm thick high pressure steam cured non asbestos fiber and fixed as in repairs complete all as specified and as directed.
Water Proofing Treatment to Sunken Floor are as under:- (a) Cleaning the surface of any description with wire brush, detecting sources of leakage/ seepages and removing/ taking down unsound treatment/ surface. (b) M&L for making holes with drill machine of dia 18mm for carrying out non-destructive waterproofing treatment to floors, sunken portion of toilet/ bathroom and junctions of floor and walls of bath/WC and floor traps (combined unit) by using construction chemical method as hydrophobic PU grouting with first course of injection MDI based PU foam and second course of injection with PU plain all as per manufacturers instruction etc and M&L for fixing the metallic packer for hydropobic PU foam sealer as per manufacturer specification. [Note :The PU foam and PU plain shall have 100% solids and solvant free and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50D.]
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius built in CM (1:6), complete all as specified.
M&L for cement concrete Type D-2 1:4:8 (by using 40mm graded stone aggregate) as in surface channels and drains, complete all as specified.
Dismantling steel work from any position complete all as specified & directed.
S&F as in repairs plates (plain or corrugated) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410(Gde-250) complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M & L for Point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated sheathed copper conductors 1100 volts grade drawn through & including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories concealed in wall/ceiling/truss including cutting chases, pinning in etc with PVC non metallic ISI marked terminal boxes concealed wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed.
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(c) One exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
Material and Labour point wiring for 15 Amps socket complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 2.5 sqmm as earth continuity conductor connected to common earth as earth dolly.
S&F Modular Switch , 6Amp, One way, 1 module, ISI marked.
S&F Modular Switch , 16Amp, One way, 1 module, ISI marked.
S&F Modular Socket , 6 Amps, 2/3 pin combined 3 module, ISI marked.
S&F Modular Socket , 16Amps, 6 pin combined 3 module, ISI marked.
S&F ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified and directed.
S&F Modular white cover plate with Frame 3 Module, ISI marked.
S&F Modular white cover plate with Frame 4 Module, ISI marked.
S&F Modular white cover plate with Frame 6 Module, ISI marked.
S&F Modular white cover plate with Frame 8 Module, ISI marked.
S&F Modular white cover plate with Frame 12 Module.
S&F Modular metal flush box 3 module flush in wall complete all as specifed and directed.
S&F Modular metal flush box 4 module flush in wall complete all as specifed and directed.
S&F Modular metal flush box 6 module flush in wall complete all as specifed and directed.
S&F Modular metal flush box 8 module flush in wall complete all as specifed and directed.
S&F Modular metal flush box 12 module flush in wall complete all as specifed and directed.
M&L in replacement Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as directed by engr-in-charge.
S&F LED lamp 14 watt, 240 volts, single phase, 50 Hz, Lumen 1450 AC supply complete all as specified and directed by Engr in Charge.
Supply and fixing LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F of New LED Bldg security light 45 Watt indus series powder coated pressure die cast aluminium high power LED bldg security light with heat resistant toughned glass with lens with IP66 Protection including 40 mm dia pipe bracket , complete all as specified and directed by Engineer-in-Charge.
S&F DB 12 way Double door TPN type, 415 volt having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed.
S&F MCB, DB, SPN 8 way double door with protection type IP-42 with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified and directed.
S & F MCB TPN 40 to 100 Amps, 415 volt, 10 KA rating complete all as specified and directed.
S & F MCB SPN 40 to 63 Amps, 240volt 10 KA rating complete all as specified and directed.
S & F MCB SP 6-32 Amps, 10 KA rating complete all as specified and directed.
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces.
Supply and fix submain wiring 4 run x 10 sqmm + 1 run x 10 sqmm earth wire FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC casing and caping/ PVC conduit of suitable dia, ISI marked including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing. [Note :- (i) Four runs of 10 Sqmm cable, 1 run of PVC casing & caping/ PVC conduit and 1 run of 10 Sqmm cable for earth shall be measured as 1 RM.]
Supply and fixing Submain wiring with proper colour coding, 2 single core FRLS 1100 Volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC casing and caping of suitable size not less than 25 mm including 1 single core cable with stranded copper conductor of size 10 Sqmm (green colour) for earthing. [Note : 2 runs of 10 Sqmm cable, 1 run of PVC Conduit/PVC casing caping and 1 run of 10 Sqmm cable shall be measured as 1 Run.]
S&F Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket for window type air conditioners.
Supply and fix , testing and commissioning of storage type water heater (geyser) vertical type of 03 Ltrs capacity , single phase, vertical type, Rust Resistant, ABS made with thermal cut off with power consumption 1500 watts, ISI marked, BEE 5 star rating including fixing on wall with chroumium plated screws & nut bolts , connection to water pipe line and electric connection complete all as specifed and directed by Engr-in-Charge.
Taking down Ceiling fan, sealing cable end, dismantling blades carefully and removing fan and blades to MES E/M Store for safe custody all as directed by Engr-in- charge.
Making round/ square hole cutting in wall with the help of cutting machine / chisel / hammer etc for fixing of exhaust fan of size 150 mm to 300 mm & making good to the distrubed surface including plaster, distumper , white wash complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories , 230 volts , 1200 sweep. Min air delivery 210 CFM with wervice value 6.0 BEE. Five star rated with brushles direct current motor.
M & L for rewinding of unserviceable exhaust fans lof size 225/300 mm sweep with approved copper enamalled wire of suitable guage, varnishing, replacing existing nut bolts pins, rubber bush, capacitor , bearing ,m bush, frastner and one coat of synthetic enamel paint by spray painting complete including taking down and refixing in exsiting position and testing complete all as specified and directed by Engr in charge.
Supply and fix heavy duty 300 mm exhaust fan metal blade (03 nos blade set) complete all as specified and directed by Engr in Charge.
Material & Labour for Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.5 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6 mm with the help of bolts, nuts, check nuts and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type D2 and PCC cover 1:2:4 type B1 watering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No.3 including taking down and connection to the earthing test point and testing on completion.
S&F CP gate valve of 15 mm bore suitable for fixing on existing fittings complete all as specified and directed by engineer in charge.
Supply and fix hot water extension pipe made out of copper chromium plated 450 mm long with brass adaptor and fixing in position complete all as specified.
Supply and fix Cold water extension pipe made out of copper chromium plated 450 mm long with brass adaptor and fixing in position complete all as specified.
Supply and fixing 15 mm Bib taps, cast copper alloy with crutch or round handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.
S&F in replacement hot water PVC pipe 15 mm bore with all fittings as required at site i.e. elbow,socket,nipple reducer & union as required for plumbing work and making connection as required at site all as specified and as directed by engr-in-charge. [Note: Rate quoted shall deemed to be inclusive of plumber work as per site requirements. ]
S&F in replacement of top plug 15 Amp 3 pin complete all as specified and directed by engineer in charge.
S&F wall mounted fan 400 mm sweep RPM 1320, 50 watt Acrylonitrile Butadiene Styrene body, pull chain type complete all as specifed and directed by Engr in Charge.
M&L for XLPE insulated, armoured heavy duty electric cable with copper conductor, 1100 volts grade, 35 sqmm 4 core laid in trenches/wall including suitable size of clamp complete all as specified and directed by Engr in Charge
S&F HDPE of pressure rating 6kg/cm sq pipe of 40 mm outer dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge.
S&F Plug and Socket enclosure,Triple pole and earthencolsure with a threepin and earth plug with socket complete with one triple pole MCB 32 Amp complete all as specifed and directed by Engr in Charge.
Supply and fix submain wiring with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing and caping of suitable dia, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing. [Note :- (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM.]
SN CONSTRUCTION (BID ID -3149336)
GANGAJAL (BID ID -3137392)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .