Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC | L1 | Accepted-AOC Successful bidder | |
| 2 | L2₹45.1 L+₹6.6 L (17.0%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹46.7 L+₹8.1 L (21.1%)Rejected-Finance 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Incomplete documents and tender fee and EMD neither uploaded and nor physical received as per Para 7b and 7c of NIT on Page No 12 and Sl No 8b (i) on Page No 10 of tender documents |
Tender Value
Refer Docs
EMD Value
₹83,800
Closing Date
27 Apr 2022, 6:00 pmClosed
GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
SPECIAL REPAIR REPLACEMENT OF ELECTRIC LT UG CABLES OVER HEAD LINES AT ATS BELAGAVI PH-I
2022_MES_515818_1
8694/E8
Open Tender
Civil Works
Item Rate
180 days
ATS sambra
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF sambra
₹83,800
Yes
31 May 2022
30 Mar 2022
29 Apr 2022
30 Mar 2022
27 Apr 2022
14 Apr 2022
Amount
Supply, laying and testing PVC underground cable XLPE Insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade of size 3.5 core 400 sq mm all as specified and directed.
Supply, laying and testing PVC underground cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 3.5 core 240 sq mm all as specified and directed.
Supply laying and testing PVC underground cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 3.5 core 150 sq mm all as specified and directed.
Supply laying and testing PVC underground cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 3.5 core 95 sq mm all as specified and directed.
Supply laying and testing PVC underground cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 3.5 core 70 sq mm all as specified and directed.
Supply laying and testing PVC underground cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 3.5 core 50 sq mm all as specified and directed.
Supply laying and testing PVC underground cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 4 core 16 sq mm all as specified and directed.
Supply laying and testing PVC underground cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 4 core 10 sq mm all as specified and directed.
Supply laying and testing PVC underground cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 4 core 6 sq mm all as specified and directed.
Supply laying and testing PVC underground cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 2 core 16 sq mm all as specified and directed.
Supply laying and testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 2 core 6 sq mm all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in hard/dense soil for laying cable/ erecting poles etc complete all as specified and directed.
Returning and filling in soil including spreading leveling watering and well ramming in layers not exceeding 25cm thick all as specified and directed.
Removing surplus excavated material/ soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
S & F double walled corrugated HDPE Pipe IS-16205, size inner dia 143 mm, outer dia 160 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed
S & F double walled corrugated HDPE Pipe IS-16205, size inner dia 103 mm, outer dia 120 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed
S & F double walled corrugated HDPE Pipe IS-16205, size inner dia 63 mm, outer dia 75 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed
M & L Cutting the tar macadam road / hard standings for laying cable and excavating not exceeding 45cm wide and 60cm in depth and getting out and filing back with PCC 1:2:4 type B-2 using 40mm graded stone aggregate and finishing to match with the adjoining surfaces complete all as specified and as directed
M & L Galvanised Iron pipe, light grade 40 MM dia. with all fitting and fixed complete to poles/route/drains/ ceillings or laid in floors complete all as specified and as directed
M & L Galvanised Iron pipe, light grade 50 MM dia. with all fitting and fixed complete to poles/route/drains/ ceillings or laid in floors complete all as specified and as directed
M & L Galvanised Iron pipe, light grade 80 MM dia. with all fitting and fixed complete to poles/route/drains/ ceillings or laid in floors complete all as specified and as directed
M & L Galvanised Iron pipe, light grade 150 MM dia. with all fitting and fixed complete to poles/route/drains/ ceillings or laid in floors complete all as specified and as directed
Supply, install, testing and commissioning factory made LT Feeder pillar Box, CPRI approved, AC 415 Volts, 50 HZ, 3 Phase, 4 wire of suitable size, cubicle fully compartmentalized type to accommodating the following accessories, totally enclosed, self supporting structure made out of 3.15 mm thick MS sheet covered on angle iron 50x50x6mm frame work with four legs grouted in PCC (1:2:4) type B1 foundation block 45x45x60cm, protection IP 54, suitable for outdoor use,, weather proof, vermin proof, bottom cable entry with suitable cable glands, suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated,
600Amps electrical grade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, internal wiring all including the following incoming complete all as specified and directed:- Note:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires. (a) MCCB, Four Poles, 400 Amps rating, 50 Hz, 415 Volts with rupturing capacity 50 KA - 01 No (Incoming) (b) MCCB, Four Poles, 315 Amps rating, 50 Hz, 415 Volts with rupturing capacity 35 KA - 01 No (outgoing) (c) MCCB FP 63 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA - 01 No (outgoing)
Supply, install, testing and commissioning factory made LT Feeder pillar Box, CPRI approved, AC 415 Volts, 50 HZ, 3 Phase, 4 wire of suitable size, cubicle fully compartmentalized type to accommodating the following accessories, totally enclosed, self supporting structure made out of 3.15 mm thick MS sheet covered on angle iron 50x50x6mm frame work with four legs grouted in PCC (1:2:4) type B1 foundation block 45x45x60cm, protection IP 54, suitable for outdoor use,, weather proof, vermin proof, bottom cable entry with suitable cable glands, suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated,
500Amps electrical grade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, internal wiring all including the following incoming complete all as specified and directed:- Note:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires. (a) MCCB, Four Poles, 315 Amps rating, 50 Hz, 415 Volts with rupturing capacity 50 KA - 01 No (Incoming) (b) MCCB, Four Poles, 250 Amps rating, 50 Hz, 415 Volts with rupturing capacity 35 KA - 01 No (outgoing) (c) MCCB FP 40 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA - 01 No (outgoing)
Supply, install, testing and commissioning factory made LT Feeder pillar Box, CPRI approved, AC 415 Volts, 50 HZ, 3 Phase, 4 wire of suitable size, cubicle fully compartmentalized type to accommodating the following accessories, totally enclosed, self supporting structure made out of 3.15 mm thick MS sheet covered on angle iron 50x50x6mm frame work with four legs grouted in PCC (1:2:4) type B1 foundation block 45x45x60cm, protection IP 54, suitable for outdoor use,, weather proof, vermin proof, bottom cable entry with suitable cable glands, suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated,
Supply, install, testing and commissioning factory made LT Feeder pillar Box, CPRI approved, AC 415 Volts, 50 HZ, 3 Phase, 4 wire of suitable size, cubicle fully compartmentalized type to accommodating the following accessories, totally enclosed, self supporting structure made out of 3.15 mm thick MS sheet covered on angle iron 50x50x6mm frame work with four legs grouted in PCC (1:2:4) type B1 foundation block 45x45x60cm, protection IP 54, suitable for outdoor use,, weather proof, vermin proof, bottom cable entry with suitable cable glands, suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated,
Supply, install, testing and commissioning factory made LT Feeder pillar Box, CPRI approved, AC 415 Volts, 50 HZ, 3 Phase, 4 wire of suitable size, cubicle fully compartmentalized type to accommodating the following accessories, totally enclosed, self supporting structure made out of 3.15 mm thick MS sheet covered on angle iron 50x50x6mm frame work with four legs grouted in PCC (1:2:4) type B1 foundation block 45x45x60cm, protection IP 54, suitable for outdoor use,, weather proof, vermin proof, bottom cable entry with suitable cable glands, suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated,
400Amps electrical grade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, internal wiring all including the following incoming complete all as specified and directed:- Note:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires. (a) MCCB, Four Poles, 250 Amps rating, 50 Hz, 415 Volts with rupturing capacity 35 KA - 01 No (Incoming) (b) MCCB, Four Poles, 200 Amps rating, 50 Hz, 415 Volts with rupturing capacity 25 KA - 02 No (outgoing) (c) MCCB, Four Poles, 63 Amps rating, 50 Hz, 415 Volts with rupturing capacity 16 KA - 01 No(outgoing)
Supply, install, testing and commissioning factory made of LT Feeder pillar Box, CPRI approved AC 415 V, 50 HZ 3 Phase 4 wire of suitable size, cubical fully comportamentalized type to accomodating the following accessories totally enclosed self supporting structure made out of 3.15 mm thick MS sheet covered on angle iron 50X50X6mm frame work with four legs grouted in PCC 1:2:4 type B1 foundation block 45X45X60cm, protection IP 54, suitable for outdoor use, weather proof, vernim proof bottom cable entry with suitable cable glands, suitable mounting arrangement for bus bars voltmeter, ammeters and MCCBs, double hinged doors at front with suitable locking arrangement, provision of louvers at sides, structure trated under 8 - tank metal treatment process and duly powder coated 400A electrical grade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, internal wiring all including the following incoming
Material and Labour for Earthing and testing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate at a depth not less than 1.5m below normal ground level connected to and including GI strip 32x6mm as earth lead by means of bolts and nuts, check nuts and washers etc made of GI & connected to equipment and earthing test point , earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work excavation, PCC chamber, RCC 1:2:4 cover with handle and 20mm dia GI medium grade watering pipe and 40 mm dia light grade GI for protection of earth strip, wire mesh, funnel, charcoal dust & common salt, etc all as specified and directed
M & L LT Cable route indicator with a welded/riveted disc of 100mm dia and engraved with cable route marker fixed on angle iron 40 x 40 x4 mm thick dug in ground with in and including PCC 1:3:6 type C1 using 20mm graded aggregate at approx distance 100 mtr including necessary earth work complete all as specified and directed
Supply and fix in repair loop in loop out box with transparent lid IP 65 weather proof of suitable size fixed to pole / wall with suitable Flat Iron clamp 20X3 mm nuts, bolts and washers including provision of 01 No miniature circuit breaker (MCB) 06 Amps, SPN 'C' Series, 240 volts 10 KA and including suitable for 1 Nos 50/16 sqmm x 3.5/4 core XLPE incoming and 1 Nos 50/16 sqmm x 3.5/4 core XLPE outgoing cable, complete all as specified and as directed
Dismantling of ACSR Conductor all as specified and directed.
Dismantling insulator of any specification all as specified and directed.
Dismantling iron scrap all as specified and directed.
Dismantling stay assembly all as specified and directed.
ASHIRWAD ELECTRICALS
M/S - KRUPA ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .