EX. ENGINEER (E AND M) M-9
D BLOCK OHT OPP DESU COLONY JANAKPURI NEW DELHI-58
Regarding power factor improvement of APFC Installation at command tank-4 in Dwarka sec 20.
2024_DJB_254203_3
N.I.T. No.24 (2023-24)/ EE(EnM)M-9
Open Tender
Civil Works
Works
30 days
OFFICE OF THE EX. ENGINEER (E AND M) M-9
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJB EMD Ac No. 50448339804
₹16,400
29 Feb 2024
19 Feb 2024
26 Feb 2024
19 Feb 2024
26 Feb 2024
19 Feb 2024
A) RENOVATION OF APFC PANEL : 2 Nos.Dismantling of defective capacitor units from the APFC panel after suitably discharging the left-over charge on capacitors to ensure safety of the working persons along with dismantling of APFC relay, indications lights, meters, A/M switches, MCBs including dismantling of terminations and existing hardware and rusted parts and various other items requiring change in the panel as required at site.
Replacement of triple pole capacitor duty contactors in place of defective contactor of 12.5 kvar in APFC panels- make Standard
Replacement of triple pole capacitor duty contactors in place of defective contactor of 5 kvar in APFC panels - make Standard
Supply of APFC relay, microprocessor based to replace defective APFC relay with digital display of power factor and other parameters to sense power factor through control CT and give phased impulses to contactor coils for switching ON-OFF required number of capacitors as per requirement to achieve target power factor- make STANDARD
Supply of heavy-duty capacitor units of various capacities, rated at 440v, 3 phase, 50 Hz system complete with terminal cover, cable end entry, mounting structure and hardware etc. -make STANDARD
Banking of capacitor units to form banks of suitable capacity by electrical interconnection with multi strand copper wires/Al. bus bars using necessary mountings and hardware, etc. as required at site.
Replacement of 32 A, triple pole MCB in place of defective MCBs of APFC panels - make Standard
Replacement of cooling fan of 6"x6" size for place of defective fans of APFC panels.
Replacement of Auto Manual to place defective Auto Manual. Make - L&T
Supply of LED indication lights of various colours to replace defective/burnt out lights make -Standard
Fixing of all above components in the APFC panel with suitable fabrication work to accommodate new items in the existing feeders for alignment of components and ease of termination complete with hardware etc. as required at site
Servicing of panels including complete dusting of all components, cleaning of contact point with CTC solution , decarbonising of various joints , tightening of all nut bolts , sleeving of live parts alignment of doors to prevent ingress of moisture and vermin and touching of rusted parts of the panels etc. as required at site.
Testing & commissioning of APFC Panel as per required parameters including following i. Continuity and earth test, ii Programming of APFC relay for target power factor ii. Meggering of all equipment’s for phase to phase and phase to earth. iii. Checking of tightness of all nut and bolts iv. Monitoring of power factor
B) REPAIR OF STATIC CAPCITORS FRO MOTOR : 03 NOS.Checking of capacitors and dismantling of defective capacitors from static capacitor banks including dismantling of terminations, wirings, hardware, as required at site.
Replacement of Super Heavy-duty capacitors of various capacities rated at 440V, 50 Hz, 3 phase AC complete with terminal cover and discharge device for replacement of defective capacitors of static capacitor banks -make standard
Banking of capacitor units to form banks of suitable capacity by electrical interconnection with multistrand copper wires/Al. bus bars using necessary mountings and hardware, etc. as required at site.
Replacement of triple pole MCCB of 250 A capacity for operation and safety of individual capacitor bank - make Standard
Installation & connection of capacitors as described above using necessary hardware, mounting arrangement and termination with multistrand copper wires, lugs, tapes etc. as required at site.
Less: Buy Back of Scrap material of APFC Panel
bhawani electrical system
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .