| 1 | L1₹42.2 LAccepted-AOC NO 8 1 KHB MAIN ROAD OPP NATURE VIEW APARTMENT MANORAYAN PALYA RT NAGAR BANGALORE 560 032 | BENGALURU URBAN | KARNATAKA | 560032 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹46.1 L+₹3.4 L (7.96%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹46.1 L+₹3.4 L (8.02%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹46.7 L+₹4.0 L (9.35%)Rejected-AOC NO 6 G 2 SS ENCLAVE 1ST MAIN 1ST CROSS INDIAN EXPRESS LAYOUT VIRUPAKSHAPURA VIDYARANYAPURA POST BANGALORE 560 097 | BENGALURU URBAN | KARNATAKA | 560097 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹48.4 L+₹5.7 L (13.4%)Rejected-AOC MILITARY ENGINEER SERVICES GARRISON ENGINEER EAST JABALPUR 482 011 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
20 Jun 2022, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
WELCOME MAINT AND REPAIR REPLACEMENT OF INTERNAL WIRING ELECTRICAL FITTINGS FIXTURES IN THE MD ACCN OF PRTC 106 IN BN 2 PARA SF UNDER GE NORTH BNG
2022_MES_525493_1
8294
Open Tender
Civil Works
Item Rate
270 days
BNG
Class D Category a(i) b(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹84,000
Yes
22 Jul 2022
21 May 2022
22 Jun 2022
21 May 2022
20 Jun 2022
7 Jun 2022
21 May 2022 - 6 Jun 2022
Amount
(B/R PORTION)
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm and Re-fixing in same opening complete all as specified and directed
Resecuring or easing & adjusting without taking down shutters of any description exc 1 sqm but n.exc 2 sqm each complete all as specified and directed
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water, etc., and disposing of debris outside MD land complete all as specified and as directed.
Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level), removing debris outside MD land, complete all as specified and as directed.
Demolition of brick work /stone masonry/pcc block masonry built in cement mortar of any description,removing debris outside MD land, all as specified and directed.
Material and labour for, brick work, with subclass 'B' bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed
All as per item No 1.006 above but except brick complete all as specified and as directed. Note: Serviceable bricks obtained during demolition shall be re-used under this item.
Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc providing material and labour for 4 mm thick figured glass, pin head type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane all as specified and as directed.
Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc providing material and labour for 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 sqm in each pane all as specified and as directed.
Supply and fix in repairs, stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm, fixed with mild steel screw & bolts all as specified and as directed.
Taking down tubular curtain rod, supply and fixing drapery rod, decorative type, made of 25 mm dia stainless steel (wall thickness not less than 0.63 mm), wood finish, colour and pattern as approved by GE, complete all as specified and as directed. (Note : Price shall not be less than 100/- per RM)
Taking down old unserviceable rod/rail, Supply and fix stainless steel type brackets suitable to hold the curtain rod with sofio phenol (Lotto) and wooden round blocks for curtain rod of 20mm dia, decorative type fixed with steel screws and PVC cleatscomplete all as specified and as directed.
Supply and fixed in repairs Aluminium anodised barrel towel bolts of extruded section of length 150 mm all as specified and as directed.
Supply and fixed in repairs Aluminium anodised barrel towel bolts of extruded section of length 200 mm all as specified and as directed.
Supply and fix in repairs 100mm Aluminium anodised barrel tower bolts of extruded section complete all as specified
Supply and fix 150mm Aluminium anodised barrel tower bolts of extruded section complete all as specified
Supply and fix in repairs Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections including taking down old sliding door bolt 300 mm all as specified and as directed.
Supply and fix in repairs Extruded alloy handles fabricated type anodised of size 100 mm all as specified and as directed.
Supply and fix aluminium handles cast type, anodised of size 150 mm all as specified and as directed.
Supply and fix in repairs Extruded alloy handles fabricated type anodised of size 150 mm all as specified and as directed.
Supply and fix in repairs Butt hinges medium weight cold rolled mild steel of size of hinges 100mm all as specified and as directed.
Supply and fix in repairs stainless steel butt hinges fixed to doors & shutters all as specified and as directed.
Supply and fix in repairs Hasp and staple safety type of size 100 mm of aluminium anodized all as specified and as directed.
Supply and fix in repairs, 100 mm size Mortice rim lock (4 lever), vertical type, brushed steel suitable for 25 to 40 mm thick doors screwing complete all as specified and as directed.
Supply and fix in repairs 40 mm dia cupboard knobs fixed with nut, screw and washer of Brass, polished complete all as specified and as directed.
Supply and fix in repairs 150 mm floor door stopper of aluminium alloy powder coated, with hard down steel spring all as specified and as directed.
Supply and fix in repairs, door closer hydraulically regulated designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg of aluminium (Die cast body) complete all as specified and as directed.
Supply and fix in repairs mild steel 300mm, ordinary rat tail rod pattern spring hinges, including roller and roller plate complete all as specified and as directed.
Supply and fix in repairs, Magnetic ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and as directed.
Taking down unserviceable boards as in shelves of cupboards, doors, etc., supply and fix 18/19 mm thick plywood, Grade 1 quality, interior grade, with decorative face veneers on one side and other side balancing white, fixed in shutters / shelves, complete all as specified and as directed.
Material and labour for, second class hardwood, plain fillets square, rectangular or triangular in section clean sawn, secured with nails or brads, fixed to cupboard shutter, cross sectional area not exceeding 3 sq cm all as specified and directed.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) area of opening not exceeding 1.5 sq m eachm providing Supply and fix, 30 mm thick Factory made solid panel PVC door shutter consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat molded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete including Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube, including making good to jambs with cement mortar (1:4) and finished to match with existing surface complete all as specified and as directed.
Supply and fix powder Coated aluminium ventilator shutters, fixed type, without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized complete all as specified and as directed. (Size of ventilator 0.60 x 0.90 mm) Note :- Sheet glass and wire gauge shall be measured and paid for separately under respective items.
Supply and fix powder coated 3 TRACK aluminium sliding window with frame and shutters (2 Nos glazed shutters and one No wire mesh shutter), without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, self closing clips, handles, etc., complete all as specified. Note :- Sheet glass and wire gauge shall be measured and paid for separately under respective items.
Material and labour for, 25 mm thick, Plain Cement concrete type B0 1:2:4 (12.5 mm graded agg) as in floorings, with surfaces, finished even and fair complete all as specified and as directed
Demolition of floor, hearth or wall tiling including cement mortar bedding (including backing), removing rubbish off the premises and disposing outside MD land and providing Material and labour, for Vitrified tiles flooring with Light shade 8-10 mm thick (Square / rectangular), tiles, not exceeding 0.36 Sq m, set and jointed in neat cement slurry and pointed in epoxy grout to match with colour of tiles over and including 15 mm thick screed bed in CM (1:4) complete all as specified and as directed.
Demolition of floor, hearth or wall tiling including cement mortar bedding (including backing), removing rubbish off the premises and disposing outside MD land and providing Material and labour, for Vitrified tile, skirting/dado, light shade with 8-10 mm thick tiles of area of each tile not exceeding 0.36 sq m, on vertical rates as in skirting, dado, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including backing coat of 10 mm thick CM 1:3 complete all as specified and as directed.
Demolition of floor, hearth or wall tiling including cement mortar bedding (including backing), removing rubbish off the premises and disposing outside MD land and providing Material and labour, for non-skid Ceramic coloured tiles 7 to 8 mm thick (Grade B-IIA), area of each tile exceeding 0.06 sq m but not exceeding 0.11 sq m, as in flooring, set and pointed in white or coloured cement to match colour of tiles over and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed.
Demolition of floor, hearth or wall tiling including cement mortar bedding (including backing), removing rubbish off the premises and disposing outside MD land and providing Material and labour, for coloured Glazed ceramic printed tiles, of size 450 x 300 x 7 mm thick (Grade B-IIA) as in vertical surfaces such as skirting, dado etc., set and jointed in neat cement slurry and pointed in epoxy grout to match with the colour of tiles, laid over and including provision of backing coat of 10 mm thick rendering in CM 1:3, complete all as specified and directed.
Demolition of stone slabs of any thickness and in any position, providing material and labour, for 18 to 20 mm thick Granite work (of any type), table rubbed and mirror polished), in single piece in steps, jambs, pillars, window-cills, cooking platform and like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, making hole for gas pipe, edges made half round, laid over and including screed bed or bedding layer of 15 mm thick in CM (1:4), complete all as specified and as directed.
Material and labour for, rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished plastered surface even and smooth without using extra cement complete all as specified and as directed
Material and labour for, rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 with WPC, finished plastered surface even and smooth without using extra cement complete all as specified and as directed. Note :- Supply only WPC will be measured and paid separately
Supply only liquid water proofing compound complete all as specified and as directed
Material and labour for, rendering 5 mm thick on ceiling / RCC surfaces in cement mortar 1:3, finished plastered surface even and smooth without using extra cement complete all as specified and as directed.
Preparation of newly plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistent primer over and including 1 mm thick wall care putty, complete all as specified and as directed. Note : Quoted rate shall deemed to include for cost of wall care putty.
Preparation of old decorated plastered or un-plastered surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of cement based paint on wall surfaces complete all as specified and as directed.
Preparation of old decorated plastered or un-plastered surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of cement based paint on wall surfaces complete all as specified and as directed.
Preparation of newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and as directed.
Preparing newly plastered ceiling surfaces and applying three coat of white wash complete all as specified & as directed.
Preparation of old decorated plastered or un-plastered surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil bound distemper on wall surfaces complete all as specified and as directed.
All as per Serial Item No 1.050 here-in-above, but on ceiling surfaces.
Preparation of old decorated plastered or un-plastered surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of oil bound distemper on wall surfaces complete all as specified and as directed.
Preparation of old decorated plastered or un-plastered surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash on wall surfaces complete all as specified and as directed.
All as per Serial Item No 1.053 here-in-above, but on ceiling surfaces.
Preparation of old decorated plastered or un-plastered surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of white wash on wall surfaces complete all as specified and as directed.
Complete removal of existing treatment and preparing the surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer over 1 mm thick wall care putty complete all as specified and directed. Note : Quoted rate shall deemed to include for cost of wall care putty.
Complete removal of existing treatment and preparing the surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
Complete removal of existing treatment and preparing the Ceiling surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
Preparation of old wooden surfaces of any description not other wise described over 10 cm width or girth applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparation of old steel surfaces of any description not other wise described over 10 cm width or girth applying one coat of synthetic enamel paint complete all as specified and as directed.
Taking down old sinks and Supply and fixing Stainless steel sink with draining board, made out of 1.00 mm thick sheet for kitchen over all size 915 mm x 460 mm with bowl size 405 x 355 x 178 mm all as per Cat No.SSSBSD-52 of Blue Star make or techno commercially equivalent in other makes specified including CP waste coupling of 40 mm dia, cast iron cantilever brackets, 40 mm dia 800 mm long corrugated PVC waste pipe, washers, connecting union etc. complete all as specified and directed.
Taking down old sinks and Supply and fixing Stainless steel sink with draining board, made out of 1.00 mm thick sheet for kitchen over all size 495mm x 420mm with bowl size 405 x 355 x 178 mm all as per Cat No.SSSB06A of Blue Star make or techno commercially equivalent in other makes specified including CP waste coupling of 40 mm dia, cast iron cantilever brackets, 40 mm dia 800 mm long corrugated PVC waste pipe, washers, connecting union etc. complete all as specified and directed.
Taking down unserviceable plate rack, supply and fix new Stainless steel plate rack of 0.63mm thick sheet, size 600mm x 750mm and of weight not less than 4.5kg each complete all as specified and directed. Make: Blue star, Model No. SSKPR-311.or techno-commercially equivalent make specified here-in-after.
Supply and fix in repairs, Vitreous china snow white, wash hand basin of size 550 mm x 400 mm excluding chain and plug and porcelain stopper including brackets, supply and fixing of 32 mm dia, PVC corrugated / flexible waste pipe, 800 mm long and with brass waste coupling of 32 mm dia, complete all as specified and as directed. Make : CERA, Cat No S2040103 or techno commercial equivalent in other makes, complete all as specified and as directed.
Supply and fix in repairs, Vitreous china, white colour, water closet pan (pedestal pattern), with PP soft seat cover, hinges, other fixing accessories set (excluding flushing cistern and flush pipe), UPVC (SWR), 'P' or 'S' trap, and connecting to drain (or outgoing pipe), flush pipe, anti syphonic pipes and removing debris outside MD land. Make : Cat Part No S1050101 of Cera or techno commercial equivalent in other makes complete all as specified and as directed.
Supply and fix in repairs, Vitreous china, white colour, 'Orissa pattern' squatting pan of size 580 mm x 440 mm with UPVC 'P' trap or 'S" Trap, front or back inlet, integral foot rests, connecting to trap, flushing pipe, anti syphonic pipe, removing debris outside MD land, complete, all as per Make : Cera, Cat No S3010102 of CALINA make or techno commercially equivalent in other makes specified here-in-after.
Supply and fix in repairs, PVC valveless, syphonic action type, flushing cistern, Duo Flush cistern 10 ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, complete all as specified and directed. (Cat No-502 of Prayag or equivalent in any approved make as in CA)
Taking down unserviceable GI/CPVC tubing, supply and fixing new CPVC pipes, outer dia 20 mm, SDR 11 Plain with all fittings, such as Tee, elbows, sockets, unions, short pieces and application of bituminous paint in concealed portion, fixed to wall/ ceiling or laid on floors, complete all as specified and as directed. Notes: Serviceable Taps, valves in any shall be removed before taking down pipe and same shall be re-fixed while providing new pipe.
All as per Serial Item No 1.068 here-in-above, but of outer dia 25 mm dia
Taking down unserviceable GI tubing, supply and fixing new 20 mm bore Galvanized Iron tubing, medium grade, with all fittings, such as Tee, elbows, sockets, unions, short pieces and application of bituminous paint in concealed portion, fixed to wall/ ceiling or laid on floors, complete all as specified and as directed. Notes: Serviceable Taps, valves in any shall be removed before taking down pipe and same shall be re-fixed while providing new pipe.
All as per Serial Item No 1.070 here-in-above, but of outer dia 25 mm dia
Supply and fix in repairs, Brass CP wall mixer for mixing hot and cold water screwed down for iron pipe, with provision for overhead shower, fixed complete all as specified and directed (Cat No-PIS-75H of Neptune series of Prayag or equivalent make as specified here-in-after)
Supply and fix in repairs, 15 mm Centre hole Basin mixture W/o Pop Up all as specified and as directed.(Cat No PIS-50 H Neptune series of Prayag or equivalent make as specified here-in-after.
Supply and fix in repairs, 15 mm pillar taps swan neck type, chromium plated cast copper alloy fancy type complete all as specified and as directed.(Cat No PIS-14H Neptune series of Prayag or equivalent make as specified here-in-after)
Supply and fix in repairs, 100mm (4") overhead shower ABS with brass Arm (225mm) & flange including fixing to steel pipe or union complete all as specified and as directed. (Cat No BS-73 Neptune series of Prayag or equivalent make as specified here-in-after).
Supply and fix in repairs, 15 mm angle cock CP cast copper alloy screwed down high pressure with capstan head handle screwed both ends or for unions etc . (Cat No PIS-10H Neptune series of Prayag or equivalent make as specified here-in-after)
Supply and fix in repairs, Bib Cock 2-way double handle with CP flange all as specified and as directed. (Cat No-PIS-12H Neptune series of Prayag or equivalent make as specified here-in-after).
Supply and fix in repairs, Chromium plated long body bib tap 15mm dia with CP flange all as specified and as directed. (Cat No-PIS-08H Neptune series of Prayag or equivalent make as specified here-in-after).
Supply and fix in repairs, Chromium plated bib tap 15mm dia with CP flange all as specified and as directed. (Cat No-PIS-06H Neptune series of Prayag or equivalent make as specified here-in-after).
Supply and fix in repairs, Health faucet, brass body with 1mtr SS braided tube & wall hook complete all as specified and as directed (Cat No-BEA-41/BEA-85 of Prayag or equivalent make as specified here-in-after)
Supply and fix in repairs, Towel rail stainless steel glossy finish complete all as specified and as directed. (Cat No-BA10S of prayag or equivalent make as specified here-in-after)
Supply and fix in repairs, Towel rack Brass glossy finish complete all as specified and directed (Cat No BA-03 of Prayag or equivalent make as specified here-in-after)
Supply and fix in repairs Towel ring Brass glossy finish complete all as specified and directed (Cat No BA-02 of Prayag or equivalent make as specified here-in-after)
Supply and fix in repairs Soap dish chromium plated brass all as per Cat Part No BA-45 of Prayag or equivlaent makes fixed in wall as per manufacturers instruction.
Supply and fix in repairs Mirror 600x450 x 5-6mm thick with frame cat No BLM-01F of PRAYAG or equivalent make complete all as specified and directed
Supply and fix in repairs PVC Mirror cabinet of size 400x500 mm (Cat No 554 of Prayag or equivalent make) complete all as specified and as directed.
Supply and fix in repairs Unbreakable (Square) wall mounted shelf 500mm (Cat No BEA-47A of Prayag or equivalent make as specified here-in-after) complete all as specified and directed
Supply and fix in repairs Unbreakable corner shelf (3Pcs set i.e, 8"-1, 10"-1 & 12"-1) (Cat No BEA-44A of Prayag or equivalent make as specified here-in-after) complete all as specified and directed
Supply and fix in repairs peg set of six (Cat No BEA 30 of Prayag or equivalent make of CA) fixed in wall as per manufacturers instruction
Supply and fix in repairs Toilet paper holder (Cat No BA-88 of Prayag or equivalent make of CA) fixed in wall as per manufacturers instructions all as specified and as directed.
Supply and fix in repairs PVC connection (Suitable for Cold Water Supply) 15 mm size with PTMT nuts of length 450 mm, all as specified and as directed.
Supply and fix in repairs PVC connection (Suitable for HOT Water Supply) 15 mm size with PTMT nuts of length 450 mm, all as specified and as directed.
Supply and fix in repairs, 32 mm dia waste fittings, brass, chromium plated for sinks, basins, etc with long screwed shanks and flynuts, flange end complete all as specified and as directed
Supply and fix in repairs, 75 mm dia waste fittings, brass,chromium plated for sinks etc with long screwed shanks and flynuts,flange end complete all as specified and as directed
Supply and fix in repairs, 32mm dia, 800mm long PVC corrugated waste pipe complete all as specified and as directed.
Supply and fix in repairs grating doom 100 mm dia of PTMT (Minimu weight 25 grams) complete all as specified and as directed
Supply and fix in repairs 15mm dia Bib tap (Minimum weight 15mm-120gms), long body, PTMT fancy type any colour screwed, for iron pipe and fixed complete all as specified and as directed.
Supply and fix in repairs 15mm dia Pillar tap PTMT fancy type (Minimum weight 15mm-120gms), any colour screwed, for iron pipe and fixed complete all as specified and as directed
Supply and fix in repairs 15mm dia angle stop valve of PTMT (Minimum weight 15mm-90gms), any colour pressed screwed, for iron pipe and fixed complete all as specified and as directed
Supply and fix in repairs, PVC water tank covers complete all as specified and as directed
Supply and fixing in repairs, EWC seat covers, white closed pattern with recessed bottom, including screws and connectors complete all as per Cat Part No B1510101 of CERA Make or equivalent in other makes, removing debris outside MD land, complete all as specified and directed.
Dismantling of water tanks of 500 litres capacity from roof top and supply and fixing Rotational moulded polyethylene water storage tanks (double layered) of 500 Litres capacity with ISI mark embossed on it, (cylindrical, vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
All as per Serial Item No 1.102 here-in-above, but re-fixing disconnected tank after carrying out repair works.
Dismantling of water tanks of 1000 litres capacity from roof top and supply and fixing Rotational moulded polyethylene water storage tanks (double layered) of 1000 Litres capacity with ISI mark embossed on it, (cylindrical, vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
All as per Serial Item No 1.104 here-in-above, but re-fixing disconnected tank after carrying out repair works.
Supply and fix in repairs, 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) complete all as specified and as directed.
Supply and fix in repairs, gun metal, globe or gate valves 20 mm bore (ISI marked) with iron wheel head screwed both ends for iron pipe complete all as specified and as directed.
Supply and fix in repairs, gun metal, globe or gate valves 25 mm bore (ISI marked) with iron wheel head screwed both ends for iron pipe complete all as specified and as directed.
Material and labour for cleaning of PVC/RCC over head water tanks at any height (on accessible/inaccessible roofs) by removing all scale, dirt, mud, any foreign material, accumulated silt, other dirty substance, algae, fungus and any other bacterial material from sides/bottom of tank, cleaning shall be done by draining / pumping out water / sludge from bottom, by high pressure water jet of pressure not less than 120 PSI for removing clogged mud/scales etc and cleaning the same again with self priming pumped fresh water and disinfecting the water tank by using UV radiator and approved chemical (chlorite), after cleaning writing letter / figures (Date of cleaning and next Date of cleaning) on black back ground with white synthetic enamel paint including removing the existing letters/ figures complete all as specified and as directed for water tanks of capacity exceeding 250 litres and not exceeding 500 litres complete all as specified and as directed.
All as per Serial Item No 1.109, but for water tanks of capacity exceeding 500 litre and not exceeding 1000 ltr.
All as per Serial Item No 1.109, but for water tanks of capacity exceeding 100 litre and not exceeding 2000 ltr. Note: (i) Contractor shall ensure that no damages / leakage occur in tank after cleaning . (ii) Any air lock /blockage of water flow after cleaning will be made good immediately.
Material and labour for spraying antiweed / non toxic solution / chemicals containing Glyphosate as per manufacture instructions and removing the weed including the roots after ensuring complete de-germification of plant/weed and cutting down the plant/trees off from roof/top sides of external walls of bldgs, in chajjas, wall junctions, junctions of GI/CI/AC/PVC pipes and taking out roots entered in wall/slabs, including making good the surface using PCC 1:2:4 type B1 or cement mortar (1:2) or brick work in CM(1:4) plastered with CM(1:4) to match with existing surface and repairing the pipes and joints which was affected by cutting down/taking out process all as specified and as directed for plants / trees located in the buildings upto four storey high, complete all as specified and directed by Engineer-in-charge. NOTE:- Contractor has to execute the work of de-generated plant/weeds as per the prior approval and directions of Engineer-in-charge.
All As per item no 1.112 here in before but plants located in the buildings of five to eight storey high.
Material and labour for cleaning of Roof (Area of Roof upto 500sqm) at height of (on accessible roof height not exc 30RM /inaccessible roofs height not exc 10RM) by removing all scale, dirt, mud, any foreign material, accumulated silt, other dirty substance, algae, fungus, leaves etc deposited over slab and making good the distrubed surfaces to match with existing surface and removing the material so obtained out side complete all as specified and directed by Engineer-in-charge. NOTE:- Contractor has to submit the phtographic record of work done (before and after the work done duly annoted the Building No/Location) at the time of claiming the payment (RAR/Final Bill). No payment has to be made without submit the photographic records.
All as per Serial Item No 1.114 here-in-above, but roof area exceeding 500 Sq m each.
(E/M PORTION)
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, call bell socket or power circuits), without taking out switches, sockets, regulators, light fittings, etc., complete and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Concealed Point Wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed in walls incl MS terminal boxes fabricated with 1.6 mm thick MS sheet, covering with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for One light point controlled by one switch / One fan point controlled by one switch/regulator / one bell/buzzer point controlled by bell push
All as per Serial Item No 2.002 here-in-above, but for one light point controlled by two way swtich
All as per Serial Item No 2.002 here-in-above, but for one 3 pin socket outlet 5 Amps on indepenedent board.
All as per Serial Item No 2.002 here-in-above, but for one 3 pin socket outlet 5 Amps on Same Board.
Material and labour for Concealed Point Wiring (For modular type switch & sockets) complete with 1.5 Sq mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiring incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for One light point controlled by one switch / One fan point controlled by one switch/regulator / one bell/buzzer point controlled by bell push
All as per Serial Item No 2.006 here-in-above, but for one light point controlled by 2 way swtich
All as per Serial Item No 2.006 here-in-above, but for one 3 pin socket outlet 5 Amps on indepenedent board.
All as per Serial Item No 2.006 here-in-above, but for one 3 pin socket outlet 5 Amps on Same Board.
Material and labour for Point Wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & Caping ISI marked incl accessories surface type wiring incl 1.6 mm thick MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for One light point controlled by one switch / One fan point controlled by one switch/regulator / one bell/buzzer point controlled by bell push
All as per Serial Item No 2.010 here-in-above, but for one light point controlled by 2 way swtich
All as per Serial Item No 2.010 here-in-above, but for one 3 pin socket outlet 5 Amps on indepenedent board.
All as per Serial Item No 2.010 here-in-above, but for socket outlet 5 Amps on Same Board.
All as per Serial Item No 2.002 here-in-above, but for concealed wiring drawn through including Conduit, but with 2.5 Sq mm cable and earth continuity conductor of 2.5 Sq mm
All as per Serial Item No 2.014 here-in-above, but with 2.5 Sq mm cable and earth continuity conductor of 2.5 Sq mm Notes for Serial Item Nos 2.002 to 2.015 :- (i) The earth wire for points in the same circuit can be looped from point to point, (ii) Earth wire shall be taken inside the conduit, (iii) Cost of terminal box shall deemed to be included in the item rate quoted for point wiring, (iv) Cost of cable from DB to any switch/ socket board to be included in point wiring. (v) Cutting chases, grooving, etc., required for taking down / providing concealed wiring will be measured and paid for separtely under respective item.
Taking down unserviceable sub main wiring, supply and fixing Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable, 2 runs of single core of size 4 Sq mm and one run of earth continuity conductor of size 4 Sq mm to be drawn through and including PVC non metallic rigid conduit complete all as specified and as directed. NOTE: - Two runs of 4 sq.mm cable, one run of 4 sq mm earth wire and PVC conduite shall be measured as one length.
Taking down unserviceable sub main wiring, supply and fixing Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable, 2 runs of single core of size 6 Sq mm and one run of earth continuity conductor of size 6 Sq mm to be drawn through and includin PVC non metallic rigid conduit complete all as specified and as directed. NOTE: - Two runs of 6 sq.mm cable, one run of 6 sq mm earth wire and PVC conduite shall be measured as one length.
Taking down unserviceable sub main wiring, supply and fixing Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable, 2 runs of single core of size 2.5 Sq mm and one run of earth continuity conductor of size 2.5 Sq mm to be drawn through and includin PVC non metallic rigid conduit complete all as specified and as directed. NOTE: - Two runs of 2.5 sq.mm cable, one run of 2.5 sq mm earth wire and PVC conduite shall be measured as one length.
Supply and fix in repairs, Modular Switch, One module, One way, 6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular Switch, One module, One way, 16 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular Switch, One module, bell push, 6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular Switch, One module, two way, 6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular socket, 6 Amps, 5 pin combined, 2 module, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular socket outlet, 2 Module, 6 pin, 6/16 Amps (multi purpose), complete all as specified and directed.
Supply and fix in repairs, Modular fan Regulator,120 W, electronic stepped type, 230 Volts 2 module, complete all as specified and as directed.
Supply and fix in repairs, piano Switch, flush type, One way, SP, 6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, piano Switch, flush type, two way, SP, 6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, flush type, bell push, SP, 5/6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, switch socket combination 5 pin, 2 in 1, 5 Amps, flush type, 240 Volts all as specified and as directed.
Supply and fix in repairs, switch socket combination 3 pin, 2 in 1, 5 & 15 Amps, flush type, 240 Volts all as specified and as directed.
Supply and fix in repairs, flush type socket outlet, 2 in 1, 3 pin 5 Amps, 240 V, complete all as specified and directed.
Supply and fix in repairs, lamp holder, pin type, pvc/polycarbonate made, complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repairs, fan Regulator, 120 W, electronic stepped type, 230 Volts, complete all as specified and as directed.
Supply and fix in repairs, Ding Dong bell, SP, AC, 230 Volts, complete all as specified and as directed.
Supply and fix in repairs, Ceiling rose surface type, Bakelite, 65 x 50 mm ISI marked with three terminals all as specified and as directed.
Supply and fix in repairs, MCB SP, 240 volts, 6 to 32 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix in repairs, MCB SPN, 240 volts, 32 to 40 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix in repairs, MCB TPN, 415 volts, 63 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix in repairs, MCB TPN, 415 volts, 100 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Taking down unserviceable sheet metal enclosure/ DB, supply and fix, MCB DB SPN 4 way (Horizontal), double door with Sheet metal enclosure, flush mounted, prewired, 240 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/ Isolators will be measured and paid separately as supply and fix under respective items.
All as per Serial Item No 2.040 here-in-above, but SPN 8 ways
All as per Serial Item No 2.040 here-in-above, but TPN 4 ways, 415 V
Supply and fixing in repirs, wall mounted LED batten, energy efficient, 20 Watt, 4 feet, with high lumen output of 2000 lumens and diffuser should be High translucent serrated milky white, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > =100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH <20%, power factor ≥ 0.90, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80 & integrated electronic driver 20 W fitting prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable complete in all respects all a directed by Engineer-in-charge. Cat Part No BCLAB 20WH LED P of Bajaj or techno commercially equivalent makes specified here-in-after complete all as specified.
All as per Serial Item No 2.043 here-in-above, but of 9/10 W LED tube light fitting 2 feet long and polycarbonate housing. Cat Part No BCLSB 10WH of Bajaj or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply and fix in repairs, down lighter fitting, 12 W, LED, efficient luminaire, aluminium die cast body with premium diffuser to ensure glare free and even distribution of light, system electrical efficiency > 85%, system efficacy > 120 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH , 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable, including lamps complete all as specified and directed. MAKE:- Cat No. BGSLO SLEEK SURFACE 12 W WH RD of Bajaj or techno-commercially equivalent mentioned here-in-after complete with all accessories pre-wired, all as specified and as directed.,
Supply and fix in repairs, bulkhead LED luminaries 10W energy efficient solution for upgrading convertional light fittings, with IP 65 protection, Make: Bajaj, Cat No : BIBWP10WLED or or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply and fix in repairs, 09/10 watt LED lamp suitable to fit in angle holder.
Taking down existing security light fitting, Supply and fix 30 W, LED security light fittings with lamp 30 W with high lumen output, environmental friendly, energy efficient LED, with pressure die cast housing with toughened glass and high power LEDs with secondary optics, with lamps and accessories, IP 66 protection, system electrical efficiency > 85%, system efficacy > 110 IP/W, 10 KV SPD, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, connecting to loop boxes electrically, light fitting conforming to Cat No ENXT P 30L WH SY PC SC of Bajaj or techno commercially equivalent approved model complete with all accessories and lamp complete all specified and as directed.
Taking down existing brackets, providing Material and labour, for bracket made of Galvanized iron pipe 25 mm dia, light grade, bend to shape not less than 1.2 mtr with 2 Nos of MS clamps fabricated out of MS Flats of size 25 x 6 mm, bolts , nuts of suitable size for fixing street light fittings, including 2 coats of aluminium paint complete all as specified and as directed.
Taking down unserviceable ceiling fan, Supply and fix new Ceiling fan BEE 5 star rated, 1200mm sweep, energy efficient suitable to function on 230V, single phase, AC supply, complete with provision for clamps for hanging of ceiling fan and accessories, writing MES No and depositing the unserviceable fan AGE EM Store yard, complete all as specified and directed.
Taking down unserviceable exhaust fan, Supply and fix new Exhaust fan with louvers, 250 / 280 / 300 mm sweep, energy efficient suitable to function on 230V, single phase, AC supply, including provision of 3 core flexible copper wire, 24/ 0.20 sq mm, writing MES No and depositing the unserviceable fan in AGE EM Store yard, complete all as specified and directed. Cat Part No 70079 MAXX AIR of Bajaj or techno commercial makes approved here-in-after.
Taking down unserviceable fresh air fan, Supply and fix new fresh air fans with louvers, 150 mm sweep, 1200 / 1400 RPM energy efficient suitable to function on 230V, single phase, AC supply, including provision of 3 core flexible copper wire, 24/ 0.20 sq mm, writing MES No and depositing the unserviceable fan in AGE EM Store yard, complete all as specified and directed.
Taking down unserviceable, storage water heaters depositing same in AGE E/M Storeyard, Supply, installation, testing and commissioning of vertical type electric storage water heater of capacity 25 litre, BEE five star rated, 230 Volt, AC, 50Hz, comprising of heating element 2000/2500 Watt, puf insulation, both power indicating LED lamp and heating indicating LED lamp, actual standing energy loss per 24 hours / 45°C temperature difference not to exceed 0.5KWH, re-heating time for 35°C temperature rise not to exceed 20 minute, adjustable thermostat (temperature range in °C is 25-75±5), rated water pressure (N/sq.cm, water head (metre)) is 80/80, glass lined tank, glass coated heating element (to prevent water scale formation on element), temperature control knob, anode ord (to protect tank from corossive element), thermal cutout, safety valve (the safety valve shall be designed to automatically relieve pressure and discharge water in case the pressure overshoots the preset limits), with and including provision of necessary suitable 3-core copper cable, suitable plug top, , fixing of geyser on wall / surface with and including provison of suitable size of wall mouting bracket and 100mm length anchor bolts, including provision of all necessary plumbing work, civil works etc., complete all as specified and directed.
Supply and fix in repairs, sheet metal enclosure, SPN, with metal plug and socket, 20 Amps, 240 Volts, complete all as specified and as directed.
Demolishing of existing earth pits, and providing Material and labour for, earthing complete with Galvanized Iron earth plate electrode 600 mm x 600 mm x 6 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized earth lead wire of 4 mm dia by means of bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 40 mm bore light grade GI pipe for watering funnel wire mesh, PCC chamber in CC (1:3:6), type C1, manhole cover with RCC (1:2:4), type B1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover and MS frame etc., complete all as specified and as directed NOTE :- Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Cutting chases, pinning in, where required for concealed conduit wiring, and making good disturbed surfaces to match with adjacent surfaces including pointing in cement mortar 1:3, girth not exceeding 15 cm on brick / PCC block masonry / concrete surfaces, complete all as specified and as directed.
OM CONSTRUCTIONS
Omkar Constructions
VIKAS CONSTRUCTIONS
deepak kumar vishwakarma
PRACHANIVA CONSTRUCTIONS
MAA ENGINEERING SERVICERS
Janatha Trading Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .