Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 CrAccepted-AOC | ₹41.5 Cr Quoted ₹41.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹48.5 CrRejected-Finance | ₹48.5 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹49.3 CrRejected-Finance | ₹49.3 Cr | L3 | Rejected-Finance L3 |
Tender Value
₹35.4 Cr
EMD Value
₹70.8 L
Closing Date
12 Jan 2022, 12:00 pmClosed
Executive Engineer-I
MPHC Office Complex
Construction of Manipur Olympians Park at Sangaithel, Manipur, on composite e-tender
2021_MPHCL_1750_1
17/EE-I/MPHC/2021-22
Open Tender
Civil Works
180 days
As per tender document
Please refer tender documents
11 documents required · 11 mandatory
₹25,000
MD MPHC Ltd.
₹70.8 L
21 Aug 2024
30 Dec 2021
12 Jan 2022
30 Dec 2021
12 Jan 2022
3 Jan 2022
31 Dec 2021 - 10 Jan 2022
Amount
SH -A:Construction of Pavilion cum Hall
EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead up to 50m and lift up to 1.5m.
Providing, laying naturally occurred sand gravel Grade -III free from organic or other deleterious constituents including watering ramming, consolidating in layers not exceeding 150mm (Spread thickness)and dressing etc. complete as directed by the Engineer-in-charge
CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centring and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. up to floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
BRICKS WORKS
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 kanhaighat coarse sand) in superstructure above plinth.
Wood Works
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position (b) Local best quality Teak Wood
P/F 38mm thick panelled, glazed or panelled & glazed shutters for doors, windows and clerestory windows i/c bright finished brass hinges (ordinary type) with necessary screws.(a)Local best quality Teak Wood
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with10mm dia bolts,nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing & Fixing M.S. grills of required patern to wooden frames of windows etc. with M.S. plates at required spacing and frames all round bar with round headed bolts & nuts or by screws(b) Ornamental grill
Providing & fixing bright finished brass 100 mm door mortice latch with one dead bolt & a pair of levers handles with necessary screws etc. complete (Indian make of approved quality).
P/F Al. Sliding door bolts bright finished or black enamelled with nuts & screws etc. complete.(a) 300x16 mm
Providing & fixing Brass Tower bolts (barrel type) with screws etc. complete.a)250 x 10 mm
Providing & fixing Brass handles with necessary screws etc. complete. (a) 125mm
Flooring Works
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand:) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
STEEL WORKS
Steel work in built up (square & hollow section) trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrom primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete.
Supply & Installation of 22mm thick (minimum) standing seam polycarbonate panels with suitable polycarbonate connector including trapezoidal HDSS Fastener, screws to fix the same on to the supporting structure including aluminium UPD etc. complete for roofing & as per the direction of the engineer in charge. The cost shall include assembling & installation of entire panel with width of 1040-1200mm (min) c/c on top of MS Structure (paid separately) to ensure a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005. Panels shall be with angular daylighting concept in translucent clear and opaque walls in two colours in single panel to achieve required Lux Levels with improved variable daylighting & shading throughout the day for better ambient temperature below the roof. Panels shall be with six to seven layers & shall pass dart drop impact test as per IS 14443-97 & shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.7 W/m2K as per EN ISO 10077-2:2018. Approve Make: Flux / DPI Daylighting or approved equivalent.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design
Providing and fixing stainless steel (grade 304 ) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge
Finishing
12mm cement plaster 1:4 (1 cement : 4 coarse sand).
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Applying ready mixed priming coat pink primer of appd. quality on wood work.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood workof appd. quality in all shades on new work to give an even shade.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat Coarse sand) with a floating coat of neat cement inside & outside as per standard design.
SH:- Providing IEI in the Multipurpose hall.
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch, modular plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X16mm2+1X16mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
P/L 70mm2 4 core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 125mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F wall mounted 12W 1739193P0 Samondra LED light with high quality Anthrasite Al. housing designed with IP 44 with connection etc as reqd.(Philips)
S/F 12W Anthrasite Garden Spike LED light with Al. housing with COB integrated lighting with IP 65, Fixture ideal for outdoor & wet areas complete with connection etc as reqd.(Philips)
S/F fan hook i/c bolt & nuts.
S/F 56"sweep (1400mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
SITC 150W energy saving, environment friendly & robust highbay(RADIOSO) LED luminaries with high efficiency suitable for ceiling(Surface/Suspended) Havell's RADIOSOHB 150W LED 75760/75790DBOPC complete with connection as reqd. (Havell's)
S/F bus bar chamber with 4 strips copper bus bar length 300mm suitable for 200 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with copper plate 600x600x6mm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for charcoal and salt for G.I.plates or copper plate earth electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Supplying & installation of ABC type 4kg capacity fire extinguisher (Repidex) etc as reqd. (ISI marked).
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked)(Repidex).
SH-B: Construction of Olympic Ring
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Providing, laying naturally occurred sand gravel Grade -III free from organic or other deleterious constituants including watering ramming,consolidating in layers not exceeding 150mm (Spread thickness)and dressing etc. complete as directed by the Engineer-in-charge
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
( d)Flat surface such as suspended floor,roofs,landing & the like ( i) floor etc upto 200mm in thickness
(f) Staircases with slopping or stepped soffits including risers & stringers excluding landing.
(e)Edges of slab and breaks in floors and walls (i) Under 20cm wide
BRICKS WORKS
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 kanhaighat coarse sand) in superstructure above plinth.
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved make ,in all colours & shades laid on 20mm thick cement mortar 1:4 (1 cem : 4 c/sand),i/c routing the joints with white cement & matching pigments etc,complete (i)size of tile-600x600mm (Double charged)branded
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved brand and manufacturer ,in all colours & shades,in skirting ,riser of steps laid with cement based high polymer modified quick set tile adhesive.(i)size of tile-600x600mm (Double charged)branded
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand:) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Steel work in built up (square & hollow section) trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrom primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 30 mm long, the perimeter of ceiling fixing to wall/partition with the help of rawl plugs at 450 mm centre with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge.
SH : FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing steel gate by using 50x50x3 mm sqm bar as as main bars horizontally and 25x25mm solid square bar vertically and 25x 8 mm as decorative bar readily available at market i/c priming , painting etc completed as per direction of Engineer -in-charge.
Fabrication, supplying, installation and commissioning of LED signage board of 5 Olympic Rings of total size of 20' outer Día & 16'5" inner Dia with Five Colour( Blue, Yellow,Black,Green & Red) acrylic and ACP sheets. LED of each ring shall be of 12V waterproof LEDs (preferably Samsung and Havells Cables). LED for each ring shall have 3 rows equally spaced. Colour of emission will be Blue, Yellow,Black,Green & Red Colour with white background. The Ring structure to be installed on the top of the Qlmp[ic Ring building shall withstand 200 km/hr wind velocity. All materials shall be as per the technical specifications of the tender and got approved before start of fabrication and installation.MS Frame Work Paid Separately
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metalliccontacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
SH:-Providing IEI in the Olympic Ring
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch, modular plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
S/F fan hook i/c bolt & nuts.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with copper plate 600x600x6mm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for charcoal and salt for G.I.plates or copper plate earth electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
SH-C: Construction of Restaurant
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Providing, laying naturally occurred sand gravel Grade -III free from organic or other deleterious constituants including watering ramming,consolidating in layers not exceeding 150mm (Spread thickness)and dressing etc. complete as directed by the Engineer-in-charge
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
(b) 1:3:6 (1 cem :3 Coarse sand:6 graded stone aggrt.40mm n/size).
(b) 1:2:4 (1 cem :2 Kanhaighat coarse sand::4 graded stone aggrt.20mm n/size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
( d)Flat surface such as suspended floor,roofs,landing & the like ( i) floor etc upto 200mm in thickness
(e)Edges of slab and breaks in floors and walls (i) Under 20cm wide
(f) Stair case ( excluding landing) slopping or stepped soffits including riser and strings etc.
BRICKS WORKS
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 kanhaighat coarse sand) in superstructure above plinth.
WOOD WORKS
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position (b) Local best quality Teak Wood
Providing and fixing 38 mm thick panelled and glazed or panelled and glazed shutters for doors, windows, c/windows etc. including bright finished brass hinges with necessary screws - (a) local best qlty Teak Wood
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand: : 6 stone aggrt. 20mm nominal guage).
Providing & Fixing M.S. grills of required patern to wooden frames of windows etc. with M.S. plates at required spacing and frames all round bar with round headed bolts & nuts or by screws (b) Ornamental grill
Providing & fixing bright finished brass 100 mm door mortice latch with one dead bolt & a pair of levers handles with necessary screws etc. complete (Indian make of approved quality).
Providing and fixing Brass sliding bolts bright finished or black enamelled with nuts & screws etc. complete.(a) 300X16 mm
Providing & fixing Brass Tower bolts (barrel type) with screws etc. complete
Providing & fixing Brass handles with necessary screws etc. complete. (a)125mm
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315 , having brand logo embossed on the body/ plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors ,embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-Charge.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing glazing in aluminium door , windows , ventilator shutter and partition etc with EPDM rudder / neoprene gasket etc complete as per the architectural drawing and the directions of engineer in charge ( Cost of aluminium snap beading shall be paid in basic item ): With plain glass panes of 4 mm thickness
Steel Work welded in built up sections framed work,i/c cutting,hoisting,fixing in position & In gratings,framed guard bars, ladders,railings,brackets and similar works applying a priming coat of red lead paints. (h) In gratings, framed guard bars, ladder, railling, brackets and similar works
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved make ,in all colours & shades laid on 20mm thick cement mortar 1:4 (1 cem : 4 c/sand),i/c routing the joints with white cement & matching pigments etc,complete (i)size of tile-600x600mm (Double charged)branded
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved brand and manufacturer ,in all colours & shades,in skirting ,riser of steps laid with cement based high polymer modified quick set tile adhesive.(i)size of tile-600x600mm (Double charged)branded
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand:) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Extra for nosing in marble stone for treads
Steel work in built up (square & hollow section) trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrom primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete.
Providing & fixing of Metal Shingles panel for roofing characterised with ASTM class A fire rating,with wind resistance in corporating with IECC solar reflectance index with minimum vapor permeance of 15 under high temperature along with compatible metal fasteners
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design
Supplying and fixing of deck profileof trapezoidal steel profile sheet TR-60 with self drilling xylan screw of 68 mm long withPVC washers MS3.16mm thick bearing end cap edge trim, restraint strap,shear stud etc. Whereever required as approved by Engineer- in- charge composite with 50mm thick CC1:2:4 (1 cem:2 Kanhaighat coarse sand : 4 stone aggregate of 20 mm) rienforcement with a mesh of # 8mm @ 200 mm C/C in both direction and finished with floating coat of neat cement
Providing and fixing 12mm thick HPL Board
SH : FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
Applying one coat of cement primer of approved quality on wall surface.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Varnishing (two or more coats) with superior Copal varnish of approved quality i/c sizing on new work.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
P / F kitchen sink white glazed vitreous china Indian make with RS or CI brackets painted white a pair of 12.5 mm CP brass pillar tap 323mm rubber plugs and CP brass chain 32mm CP brass waist of standard pattern 32 mm dia. MI/CP brass traps and unions complete i/c cutting and making good the walls Indian fittings.a) 610 x 450 x 250 mm
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Providing and fixing 600 x120 x 5 mm glass shelf (Indian make) with C.P. brass brackets guard nail complete fixed to wooden cleats with C.P. brass screws.
Providing and fixing 610 x 20 mm Diplomat brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws
Providing and fixing C.P. brass toilet paper holder
Providing and fixing liquid soap container of glass with C.P. lid and brackets fixed to wooden cleats with C.P. brass screws.
Providing and fixing brass bib cock of approved quality. 25 mm diameter (Swan neck left/right HN Delux)
Providing and fixing brass stop cock of approved quality.50 mm diameter
Providing and fixing brass full way G.M valve with CI wheel of approved quality.50 mm diameter
Providing and fixing Water Storage Tanks with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level.2000 litres net capacity storage tanks
P/F 110 mm PVC soil waste and vent pipe
P/F 75 mm PVC soil waste and vent pipe
P/F 110mm PVC plain bend of required degree
P/F socket joints to 110 mm PVC pipes
P/F plain Tee to 110 mm PVC pipes
P/F Vent Cowl joints.75 mm
Providing and fixing C.I. cover with frame for (manhole and chamber). (a) 600 X 450 mm (Heavy duty) ( 38 kg).
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 25 mm nominal outer dia Pipes
SH:- Providing IEI in the Restaurant.
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch, modular plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
SH:- Providing IEI in the Restaurant.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
P/L 50mm2 four core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F Blithe Pendant 3XE27 LED bulb capacity light model no 58076 with Metal/Al shade housing complete with connection etc as reqd.(Philips)(excluding bulb)
S/F Gleam Pendant 1XE27 LED bulb capacity light model no 58125 with Stainless steel complete with connection etc as reqd.(Philips)(excluding bulb)
S/F 9W LED bulb
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
S/F fan hook i/c bolt & nuts.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power LED as light source Havell's JETACOMPECTOFL50W LED 757LTG complete with connection as rqd. (Havell's)
S/F bus bar chamber with 4 strips copper bus bar length 300mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with copper plate 600x600x6mm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for charcoal and salt for G.I.plates or copper plate earth electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Supplying & installation of ABC type 4kg capacity fire extinguisher (Repidex) etc as reqd. (ISI marked).
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked)(Repidex).
SH-D:Construction of DG Room& Electrical
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Providing, laying naturally occurred sand gravel Grade -III free from organic or other deleterious constituants including watering ramming,consolidating in layers not exceeding 150mm (Spread thickness)and dressing etc. complete as directed by the Engineer-in-charge
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
BRICKS WORKS
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 kanhaighat coarse sand) in superstructure above plinth.
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved make ,in all colours & shades laid on 20mm thick cement mortar 1:4 (1 cem : 4 c/sand),i/c routing the joints with white cement & matching pigments etc,complete (i)size of tile-600x600mm (Double charged)branded
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved brand and manufacturer ,in all colours & shades,in skirting ,riser of steps laid with cement based high polymer modified quick set tile adhesive.(i)size of tile-600x600mm (Double charged)branded
Steel work in built up (square & hollow section) trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrom primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 30 mm long, the perimeter of ceiling fixing to wall/partition with the help of rawl plugs at 450 mm centre with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge.
Providing & fixing of Metal Shingles panel for roofing characterised with ASTM class A fire rating,with wind resistance in corporating with IECC solar reflectance index with minimum vapor permeance of 15 under high temperature along with compatible metal fasteners
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design
Trapzoidal Pre-painted Profile Sheet for Ridges, Gutter or valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screw with PVC washer & cap complete excluding the coat of purlins rafter & trusses.a) Pre painted alvalume sheet(PPGL) i) Sheet 0.50mm/4.2 kgs/sqm
Providing and fixing 12mm thick HPL Board
SH : FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Applying one coat of cement primer of approved quality on wall surface.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
SH:-Providing IEI in the DG and Electrical Room
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch, modular plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power LED as light source Havell's JETACOMPECTOFL50W LED 757LTG complete with connection as rqd. (Havell's)
Design, supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of four way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :-
1. 250 amp. TPN on load changeover switch - 1 No.
2. 250 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 4 Nos.
S/F 200 amp Kit Kat Fuse
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Supplying & installation of ABC type 4kg capacity fire extinguisher (Repidex) etc as reqd. (ISI marked).
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked)(Repidex).
SH-E:Construction of Wash Room
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Providing, laying naturally occurred sand gravel Grade -III free from organic or other deleterious constituants including watering ramming,consolidating in layers not exceeding 150mm (Spread thickness)and dressing etc. complete as directed by the Engineer-in-charge
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 (1 cem :2 Kanhaighat coarse sand::4 graded stone aggrt.20mm n/size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
( d)Flat surface such as suspended floor,roofs,landing & the like ( i) floor etc upto 200mm in thickness
(e)Edges of slab and breaks in floors and walls (i) Under 20cm wide
BRICKS WORKS
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 kanhaighat coarse sand) in superstructure above plinth.
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved make ,in all colours & shades laid on 20mm thick cement mortar 1:4 (1 cem : 4 c/sand),i/c routing the joints with white cement & matching pigments etc,complete (i)size of tile-600x600mm (Double charged)branded
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved brand and manufacturer ,in all colours & shades,in skirting ,riser of steps laid with cement based high polymer modified quick set tile adhesive.(i)size of tile-600x600mm (Double charged)branded
Steel work in built up (square & hollow section) trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrom primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 30 mm long, the perimeter of ceiling fixing to wall/partition with the help of rawl plugs at 450 mm centre with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge.
Providing & fixing of Metal Shingles panel for roofing characterised with ASTM class A fire rating,with wind resistance in corporating with IECC solar reflectance index with minimum vapor permeance of 15 under high temperature along with compatible metal fasteners
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design
Trapzoidal Pre-painted Profile Sheet for Ridges, Gutter or valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screw with PVC washer & cap complete excluding the coat of purlins rafter & trusses.a) Pre painted alvalume sheet(PPGL) i) Sheet 0.50mm/4.2 kgs/sqm
Providing and fixing 12mm thick HPL Board
SH : FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :a)Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Providing and fixing 600 x120 x 5 mm glass shelf (Indian make) with C.P. brass brackets guard nail complete fixed to wooden cleats with C.P. brass screws.
Providing and fixing 610 x 20 mm Diplomat brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws
Providing and fixing C.P. brass toilet paper holder
Providing and fixing liquid soap container of glass with C.P. lid and brackets fixed to wooden cleats with C.P. brass screws.
Providing and fixing brass bib cock of approved quality. 25 mm diameter (Swan neck left/right HN Delux)
Providing and fixing brass stop cock of approved quality.50 mm diameter
Providing and fixing brass full way G.M valve with CI wheel of approved quality.50 mm diameter
Providing and fixing Water Storage Tanks with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level.2000 litres net capacity storage tanks
P/F 110 mm PVC soil waste and vent pipe
P/F 75 mm PVC soil waste and vent pipe
P/F 110mm PVC plain bend of required degree
P/F socket joints to 110 mm PVC pipes
P/F plain Tee to 110 mm PVC pipes
P/F Vent Cowl joints.75 mm
Providing and fixing C.I. cover with frame for (manhole and chamber). (a) 600 X 450 mm (Heavy duty) ( 38 kg).
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 25 mm nominal outer dia Pipes
SH:-Providing IEI in the Toilet Block
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch, modular plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
15/16 amps switch
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
SH-F:Construction of Care Taker
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Providing, laying naturally occurred sand gravel Grade -III free from organic or other deleterious constituants including watering ramming,consolidating in layers not exceeding 150mm (Spread thickness)and dressing etc. complete as directed by the Engineer-in-charge
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
BRICKS WORKS
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 kanhaighat coarse sand) in superstructure above plinth.
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved make ,in all colours & shades laid on 20mm thick cement mortar 1:4 (1 cem : 4 c/sand),i/c routing the joints with white cement & matching pigments etc,complete (i)size of tile-600x600mm (Double charged)branded
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved brand and manufacturer ,in all colours & shades,in skirting ,riser of steps laid with cement based high polymer modified quick set tile adhesive.(i)size of tile-600x600mm (Double charged)branded
Steel work in built up (square & hollow section) trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrom primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 30 mm long, the perimeter of ceiling fixing to wall/partition with the help of rawl plugs at 450 mm centre with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge.
Providing & fixing of Metal Shingles panel for roofing characterised with ASTM class A fire rating,with wind resistance in corporating with IECC solar reflectance index with minimum vapor permeance of 15 under high temperature along with compatible metal fasteners
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design
Trapzoidal Pre-painted Profile Sheet for Ridges, Gutter or valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screw with PVC washer & cap complete excluding the coat of purlins rafter & trusses.a) Pre painted alvalume sheet(PPGL) i) Sheet 0.50mm/4.2 kgs/sqm
Providing and fixing 12mm thick HPL Board
SH : FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
SH:-Providing IEI in the Care Taker Room
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch, modular plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
S/F fan hook i/c bolt & nuts.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with copper plate 600x600x6mm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for charcoal and salt for G.I.plates or copper plate earth electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
SH-G:Construction of Souvenir shop
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Providing, laying naturally occurred sand gravel Grade -III free from organic or other deleterious constituants including watering ramming,consolidating in layers not exceeding 150mm (Spread thickness)and dressing etc. complete as directed by the Engineer-in-charge
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
BRICKS WORKS
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 kanhaighat coarse sand) in superstructure above plinth.
Providing and fixing 8 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing glazing in aluminium door , windows , ventilator shutter and partition etc with EPDM rudder / neoprene gasket etc complete as per the architectural drawing and the directions of engineer in charge ( Cost of aluminium snap beading shall be paid in basic item ): With plain glass panes of 4 mm thickness
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved make ,in all colours & shades laid on 20mm thick cement mortar 1:4 (1 cem : 4 c/sand),i/c routing the joints with white cement & matching pigments etc,complete (i)size of tile-600x600mm (Double charged)branded
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved brand and manufacturer ,in all colours & shades,in skirting ,riser of steps laid with cement based high polymer modified quick set tile adhesive.(i)size of tile-600x600mm (Double charged)branded
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand:) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Steel work in built up (square & hollow section) trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrom primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 30 mm long, the perimeter of ceiling fixing to wall/partition with the help of rawl plugs at 450 mm centre with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge.
Providing & fixing of Metal Shingles panel for roofing characterised with ASTM class A fire rating,with wind resistance in corporating with IECC solar reflectance index with minimum vapor permeance of 15 under high temperature along with compatible metal fasteners
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design
Trapzoidal Pre-painted Profile Sheet for Ridges, Gutter or valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screw with PVC washer & cap complete excluding the coat of purlins rafter & trusses.a) Pre painted alvalume sheet(PPGL) i) Sheet 0.50mm/4.2 kgs/sqm
Providing and fixing 12mm thick HPL Board
SH : FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Applying one coat of cement primer of approved quality on wall surface.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
SH:-Providing IEI in the Souvenier Shop
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch, modular plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 10W 840 LHEAAGP6IA2W010 complete with connection as rqd. (Havell's)
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power LED as light source Havell's JETACOMPECTOFL50W LED 757LTG complete with connection as rqd. (Havell's)
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with copper plate 600x600x6mm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for charcoal and salt for G.I.plates or copper plate earth electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Supplying & installation of ABC type 4kg capacity fire extinguisher (Repidex) etc as reqd. (ISI marked).
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked)(Repidex).
SH-H:Construction of Water Fountain
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Providing, laying naturally occurred sand gravel Grade -III free from organic or other deleterious constituants including watering ramming,consolidating in layers not exceeding 150mm (Spread thickness)and dressing etc. complete as directed by the Engineer-in-charge
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
Flooring Works
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand:) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
SH-I:Construction & the provding of Nursery
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
Steel Work welded in built up sections framed work,i/c cutting,hoisting,fixing in position & In gratings,framed guard bars, ladders,railings,brackets and similar works applying a priming coat of red lead paints. (h) In gratings, framed guard bars, ladder, railling, brackets and similar works
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
Providing External Solar Lighting
Supply, Installation, Testing & Commissioning of solar LED Street lamp All-in -One with in built SCC system wattage of 30W of make Crompton Greaves ltd code no. CSADEMP25/30CDL,140 Lumen/Watt high efficiency crystaline solar SPV panel and G.I. Tubular/Octagonal pole of 6 mt high including connection and muffing in RCC 1:3:6(1 cemt: 3 c/sand: 6 stone aggrt of 40 mm n/size) including centering, shutturing, earth work etc. as reqd.
SH-J:Construction of R.C.C. Steps
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 (1 cem :2 Kanhaighat coarse sand::4 graded stone aggrt.20mm n/size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
BRICKS WORKS
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Providing and fixing stainless steel (grade 304 ) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand:) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Extra for nosing in marble stone for treads
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
SH-K:Construction of Planter Box
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(g) Vertical surface such as walls (any thickness), partition and the like including attached pilasters, buttresses, plinth and the string courses and the like
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand:) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
SH-L:Construction of Compound Wall
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 kanhaighat coarse sand) in superstructure above plinth.
Polygonal rubble masonry ( uncoursed / brought to courses ) squared rubble masonry (uncoursed /brought to courses ) with hard stone of approved quality in foundation & plinth in cement mortar 1: 6 (1 cement:6 coarse sand) i/c levelling up with cement concrete 1:6:12 (1 cement:6 coarse sand:12 stone aggregate 20 mm nominal size) at plinth level.
SH : FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
Applying one coat of cement primer of approved quality on wall surface.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
Supplying and fixing galvanised steel barbed wire. weighing 9.38kg/100 m straining and fixing to any type of standard rails straining bolts i/c securing with and provision of galvanised mild steel wire, staples or steel pins etc as directed (Posts and struts of wood, concrete, steel and straining bolts shall be paid separately).
SH-M:Construction of Main Gate
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Providing, laying naturally occurred sand gravel Grade -III free from organic or other deleterious constituants including watering ramming,consolidating in layers not exceeding 150mm (Spread thickness)and dressing etc. complete as directed by the Engineer-in-charge
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
BRICKS WORKS
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand:) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Steel work in built up (square & hollow section) trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrom primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete.
Providing & fixing of Metal Shingles panel for roofing characterised with ASTM class A fire rating,with wind resistance in corporating with IECC solar reflectance index with minimum vapor permeance of 15 under high temperature along with compatible metal fasteners
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design
Trapzoidal Pre-painted Profile Sheet for Ridges, Gutter or valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screw with PVC washer & cap complete excluding the coat of purlins rafter & trusses.a) Pre painted alvalume sheet(PPGL) i) Sheet 0.50mm/4.2 kgs/sqm
Providing and fixing steel gate by using 50x50x3 mm sqm bar as as main bars horizontally and 25x25mm solid square bar vertically and 25x 8 mm as decorative bar readily available at market i/c priming , painting etc completed as per direction of Engineer -in-charge.
SH-N:Construction of RCC Culvert
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
(c) 1:3:6 (1 cem :3 Kanhaighat coarse sand: 6 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
(g) Vertical surface such as walls (any thickness), partition and the like including attached pilasters, buttresses, plinth and the string courses and the like
( d)Flat surface such as suspended floor,roofs,landing & the like ( i) floor etc upto 200mm in thickness
(e)Edges of slab and breaks in floors and walls (i) Under 20cm wide
SH-O:Construction of RCC Retaining Wall
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 (1 cem :2 Kanhaighat coarse sand::4 graded stone aggrt.20mm n/size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(g) Vertical surface such as walls (any thickness), partition and the like including attached pilasters, buttresses, plinth and the string courses and the like
Providing weep holes in plain Concrete/ Reinforced Concrete abutment, wing wall/return wall complete as per drawing and technical specification
Providing and fixing stailess steel (Grade 304) railing made of hollow tubes, channels, plates & fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fashner, stainless steel bolts etc. of required size, on the top of the floor to the side of waist slab with suitable arrangement approval of Engineer-in-charge, (for payment purpose only weight of stainless steel member shall be consider excluding fixing accessories such as nuts, bolts, fastners etc.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
SH-P:Construction of RCC Water Tank
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Providing, laying naturally occurred sand gravel Grade -III free from organic or other deleterious constituants including watering ramming,consolidating in layers not exceeding 150mm (Spread thickness)and dressing etc. complete as directed by the Engineer-in-charge
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
( d)Flat surface such as suspended floor,roofs,landing & the like ( i) floor etc upto 200mm in thickness
(e)Edges of slab and breaks in floors and walls (i) Under 20cm wide
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
P/F C.I cover with frame for (manhole and chamber) (a) 600x450mm (Heavy duty)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 25 mm nominal outer dia Pipes
SH-Q:Construction of Road side RCC Drain
SH 1 :-Hill Side Drain
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 (1 cem :2 Kanhaighat coarse sand::4 graded stone aggrt.20mm n/size).
STONE WORKS
Polygonal rubble masonry ( uncoursed / brought to courses ) squared rubble masonry (uncoursed /brought to courses ) with hard stone of approved quality in foundation & plinth in cement mortar 1: 6 (1 cement:6 coarse sand) i/c levelling up with cement concrete 1:6:12 (1 cement:6 coarse sand:12 stone aggregate 20 mm nominal size) at plinth level.
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
SH 2 :- Intermediate Drain
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
Steel Work welded in built up sections framed work,i/c cutting,hoisting,fixing in position & In gratings,framed guard bars, ladders,railings,brackets and similar works applying a priming coat of red lead paints. (h) In gratings, framed guard bars, ladder, railling, brackets and similar works
SH-R:Construction of Road Work
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 metres in width as well as 10 sqm on plan i/c disposal of excavated earth lead upto 50 m and lift upto 1.5 m disposal soil to be levelled and neatly dressed in(b) Hard/Dense Soil.
Providing and laying & compacting granular base/sub-base according to lines, grades & cross-sections by using naturally occuring sand gravel/conforming to IRC Grade - 2 of M.O.S.T. specification free from organic or other deleterious constituent compact by rolling with power roller of 8 to 10 tonnes capacity in layers not exceeding 150 mm (spread thickness) including rolling of the road surface to proper level & grade 30 cm width edging on both sides etc. complete as directed by the Engineer-in-charge
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specifications including premixing the material with water at OMC in mechanical mix (Pug Mill), carraige of mixed material by tipper to sie laying in uniform layers in sub- base / base course on well prepared underbase and compacting with power vibratory- roller to achievethe desired density including lighting,guarding,barrricating and maintenance of diversion etc.
Preparing surface by brushing with wire brushes for remaining caked mud etc. sweeping with brooms and finally fanning the cleared surface with gunny bags to removed all loose dirt etc.
Providing & applying evenly a priming/tack coat with bitumen (80/100). (a) 10 kg/10sqm
Providing and laying bituminous macadam of 50 mm as per clause 504.1 of "MOST" specification for base course with binder content @ 4% by weight of total mix including preparation of bases including filling of pot holes, cleaning the surface with wire brushes etc. and providing suitable edge supports heating of binder and aggregate handling of materials, screening, mixing, in hot mix plant conforming and transporting laying and finishing with paver finisher to the required level, grade and camber, rolling by power roller etc. complete including running expenses of all plants.
2 cm consolidated thick single coat pre-mix carpet surfacing with 0.27 cum stone chipping 12.0 mm size 0.19 cum and 10 mm size 0.09 cum mix with 14.6 kg of binder per 10.00 sqm of road surface and rolling complete including a seal coat IRC type "B" with 0.06 cum of fine aggregate and 6.8 kg of bitumen 80/100 per 10.00 sqm of road surface using H.M. plant & paver finisher
SH-S:Construction of General & VIP Parking
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 (1 cem :2 Kanhaighat coarse sand::4 graded stone aggrt.20mm n/size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
BRICKS WORKS
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
SH : FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
Applying one coat of cement primer of approved quality on wall surface.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
Providing and laying & compacting granular base/sub-base according to lines, grades & cross-sections by using naturally occuring sand gravel/conforming to IRC Grade - 2 of M.O.S.T. specification free from organic or other deleterious constituent compact by rolling with power roller of 8 to 10 tonnes capacity in layers not exceeding 150 mm (spread thickness) including rolling of the road surface to proper level & grade 30 cm width edging on both sides etc. complete as directed by the Engineer-in-charge
Providing and laying 80 mm thick factory made cement concrete interlocking paver block (Rubber Moulded ) of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over 10 cm thick C.C. 1:4:8 ( 1 cement :2 Kanhaighat coarse sand :4 graded stone aggrt. 40mm nominal size)and filling the joints with cement mortar 1:3 (1 cement : 3 kanhaighat coarse sand) all complete as per the direction of the engineer-in -charge.
SH-T:Providing of Paver block
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 (1 cem :2 Kanhaighat coarse sand::4 graded stone aggrt.20mm n/size).
Providing and laying & compacting granular base/sub-base according to lines, grades & cross-sections by using naturally occuring sand gravel/conforming to IRC Grade - 2 of M.O.S.T. specification free from organic or other deleterious constituent compact by rolling with power roller of 8 to 10 tonnes capacity in layers not exceeding 150 mm (spread thickness) including rolling of the road surface to proper level & grade 30 cm width edging on both sides etc. complete as directed by the Engineer-in-charge
Providing and laying 80 mm thick factory made cement concrete interlocking paver block (Rubber Moulded ) of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over 10 cm thick C.C. 1:4:8 ( 1 cement :2 Kanhaighat coarse sand :4 graded stone aggrt. 40mm nominal size)and filling the joints with cement mortar 1:3 (1 cement : 3 kanhaighat coarse sand) all complete as per the direction of the engineer-in -charge.
SH-U:Construction of Ticket Counter
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 (1 cem :2 Kanhaighat coarse sand::4 graded stone aggrt.20mm n/size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
( d)Flat surface such as suspended floor,roofs,landing & the like ( i) floor etc upto 200mm in thickness
(e)Edges of slab and breaks in floors and walls (i) Under 20cm wide
BRICKS WORKS
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 kanhaighat coarse sand) in superstructure above plinth.
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position (b) Local best quality Teak Wood
Providing and fixing 38mm thick panelled and glazed or panelled and glazed shutters for doors, windows, c/windows ect. Including bright finished brass hinges with necessary screws-(a) Local best quality teak wood.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarsesand : 6 stone aggrt. 20mm nominal guage).
Providing & fixing bright finished brass 100 mm door mortice latch with one dead bolt & a pair of levers handles with necessary screws etc. complete (Indian make of approved quality).
Providing and fixing Brass sliding bolts bright finished or black enamelled with nuts & screws etc. complete.(a) 300X16 mm
Providing & fixing Brass Tower bolts (barrel type) with screws etc. complete (b) 100x10 mm
Providing & fixing Brass handles with necessary screws etc. complete. (a)125mm
Providing and fixing aluminium works for doors windows ventilators and partions worth extruded builts up standard tubular section /appropriate Z sections and other section of approved make conforming to IS 733 and IS 1285 fixed with expansion hold fasteners including necessary filling up gap at junction at top bottom and side with required EPDM rubber/Neoprene gasket etc Aluminium snap beading for glazing /panelling C P brass/stainless steel screws all complete as per archectural drawing and the direction of engineer in charge(glazing and panelling to be paid for separately 10.66.1 Anodised aluminium ( anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15 )
Providing and fixing glazing in aluminium door , windows , ventilator shutter and partition etc with EPDM rudder / neoprene gasket etc complete as per the architectural drawing and the directions of engineer in charge ( Cost of aluminium snap beading shall be paid in basic item ): With plain glass panes of 4 mm thickness
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved make ,in all colours & shades laid on 20mm thick cement mortar 1:4 (1 cem : 4 c/sand),i/c routing the joints with white cement & matching pigments etc,complete (i)size of tile-600x600mm (Double charged)branded
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved brand and manufacturer ,in all colours & shades,in skirting ,riser of steps laid with cement based high polymer modified quick set tile adhesive.(i)size of tile-600x600mm (Double charged)branded
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand:) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
SH : FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
Applying one coat of cement primer of approved quality on wall surface.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
Varnishing (two or more coats) with superior Copal varnish of approved quality i/c sizing on new work.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
SH:-Providing IEI in the Ticket Counter
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch, modular plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F 300 mm dia wall mounting fan complete with all accessories as reqd.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power LED as light source Havell's JETACOMPECTOFL50W LED 757LTG complete with connection as rqd. (Havell's)
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Supplying & installation of ABC type 4kg capacity fire extinguisher (Repidex) etc as reqd. (ISI marked).
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked)(Repidex).
SH-V:Construction of Security Booth
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 (1 cem :2 Kanhaighat coarse sand::4 graded stone aggrt.20mm n/size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1:2 (1 cement : 1 Kanhaighat coarse sand: : 2 graded stone aggrt. 20mm nominal size).
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
( d)Flat surface such as suspended floor,roofs,landing & the like ( i) floor etc upto 200mm in thickness
(e)Edges of slab and breaks in floors and walls (i) Under 20cm wide
BRICKS WORKS
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 kanhaighat coarse sand) in superstructure above plinth.
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position (b) Local best quality Teak Wood
Providing and fixing 38mm thick panelled and glazed or panelled and glazed shutters for doors, windows, c/windows ect. Including bright finished brass hinges with necessary screws-(a) Local best quality teak wood.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarsesand : 6 stone aggrt. 20mm nominal guage).
Providing & fixing bright finished brass 100 mm door mortice latch with one dead bolt & a pair of levers handles with necessary screws etc. complete (Indian make of approved quality).
Providing and fixing Brass sliding bolts bright finished or black enamelled with nuts & screws etc. complete.(a) 300X16 mm
Providing & fixing Brass Tower bolts (barrel type) with screws etc. complete (b) 100x10 mm
Providing & fixing Brass handles with necessary screws etc. complete. (a)125mm
Providing and fixing aluminium works for doors windows ventilators and partions worth extruded builts up standard tubular section /appropriate Z sections and other section of approved make conforming to IS 733 and IS 1285 fixed with expansion hold fasteners including necessary filling up gap at junction at top bottom and side with required EPDM rubber/Neoprene gasket etc Aluminium snap beading for glazing /panelling C P brass/stainless steel screws all complete as per archectural drawing and the direction of engineer in charge(glazing and panelling to be paid for separately 10.66.1 Anodised aluminium ( anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15 )
Providing and fixing glazing in aluminium door , windows , ventilator shutter and partition etc with EPDM rudder / neoprene gasket etc complete as per the architectural drawing and the directions of engineer in charge ( Cost of aluminium snap beading shall be paid in basic item ): With plain glass panes of 4 mm thickness
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved make ,in all colours & shades laid on 20mm thick cement mortar 1:4 (1 cem : 4 c/sand),i/c routing the joints with white cement & matching pigments etc,complete (i)size of tile-600x600mm (Double charged)branded
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved brand and manufacturer ,in all colours & shades,in skirting ,riser of steps laid with cement based high polymer modified quick set tile adhesive.(i)size of tile-600x600mm (Double charged)branded
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand:) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
SH : FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand:).
Applying one coat of cement primer of approved quality on wall surface.
Providing and applying wall putty/plaster of paris putty of 2 mm thickness over plaster surface to prepared the surface even and smooth complete.
Finishing walls weather shield paint of approved quality on new work ( three or more coats ) to give an even shade.
Varnishing (two or more coats) with superior Copal varnish of approved quality i/c sizing on new work.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
SH:-Providing IEI in the Security Booth
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch, modular plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F 300 mm dia wall mounting fan complete with all accessories as reqd.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power LED as light source Havell's JETACOMPECTOFL50W LED 757LTG complete with connection as rqd. (Havell's)
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Supplying & installation of ABC type 4kg capacity fire extinguisher (Repidex) etc as reqd. (ISI marked).
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked)(Repidex).
SH-W:Construction of Display Gazebo
Earth work
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.(i) loose/soft soil (a) Lift upto 1.5m
Filling in plinth with sandy soil under floors including watering ramming,consolidating and dressing complete with a lead of 15 km
Concrete Works
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 40mm nominal size).
RCC Works
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
Flooring Work
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Providing & Fixing of Metal Singles with Cement Fiber Board 19mm thick including bitumen adshive etc as diected by Engineer In Charge
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
SH-X:Construction of Watch Tower
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Providing, laying naturally occurred sand gravel Grade -III free from organic or other deleterious constituants including watering ramming,consolidating in layers not exceeding 150mm (Spread thickness)and dressing etc. complete as directed by the Engineer-in-charge
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Kanhaighat coarse sand:: 8 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 18.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Reinforcement for R.C.C.work including bending,binding and placing in position complete (b) TMT bars.
FORM WORKS
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
Flooring Works
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand:) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
STEEL WORKS
Steel work in built up (square & hollow section) trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrom primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete.
Supply & Installation of 22mm thick (minimum) standing seam polycarbonate panels with suitable polycarbonate connector including trapezoidal HDSS Fastener, screws to fix the same on to the supporting structure including aluminium UPD etc. complete for roofing & as per the direction of the engineer in charge. The cost shall include assembling & installation of entire panel with width of 1040-1200mm (min) c/c on top of MS Structure (paid separately) to ensure a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005. Panels shall be with angular daylighting concept in translucent clear and opaque walls in two colours in single panel to achieve required Lux Levels with improved variable daylighting & shading throughout the day for better ambient temperature below the roof. Panels shall be with six to seven layers & shall pass dart drop impact test as per IS 14443-97 & shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.7 W/m2K as per EN ISO 10077-2:2018. Approve Make: Flux / DPI Daylighting or approved equivalent.
SH-Y:Hill Cutting & Development works
SH : EARTH WORK
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Banking excavated earth in layer not exceeding 20 cn in depth , breaking clods , watering , rolling each layer with 1/2 tonne roller or wooden or steel rammer and rolling every third and top most layer with power roller of minimum 8 tonne and dressing up in embankment for roads marginal banks flood banks and guide bank lead upto 50 metres and lift upto 1.5 metre (a) Hard / dense soil
Andy Pamei
Laishram Lalitkumar Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid