| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-Finance | L1 | Accepted-Finance Lowest and Reasonable Bid | |
| 2 | L2₹8.2 L+₹84,480 (11.4%)Rejected-Finance | L2 | Rejected-Finance other than lowest bid | |
| 3 | L3₹8.8 L+₹1.4 L (18.7%)Rejected-Finance | L3 | Rejected-Finance other than lowest bid | |
| 4 | L4₹8.9 L+₹1.5 L (20.0%)Rejected-Finance | L4 | Rejected-Finance other than lowest bid |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
25 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) SURANUSSI
SURANUSSI
REPAIR/ MAINT OF DBs, ELECTRIC CONNECTION TO BLDG AND ALLIED WORKS AT MIL STN SURANUSSI UNDER AGE(I) SURANUSSI
2023_MES_620945_1
AGE(I)S-23/2023-24
Open Tender
Civil Works
Item Rate
270 days
SURANUSSI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) SURANUSSI
₹20,000
Yes
8 Nov 2023
29 Sept 2023
1 Nov 2023
29 Sept 2023
25 Oct 2023
13 Oct 2023
Amount
Taking down of old DBs with MCB/ fuses any size and rating complete from the position after disconnecting the electrical connection all as specified and as directed.
S & F Sheet metal enclosure conceiled to the wall for 12 way Distribution Boards (DB’s), double door, single pole & neutral with 100 amps rated bus bar,suitable for fixing MCBs/RCBOs all as specified and directed.
S & F in repairs/replacement double door, sheet metal enclosure, powder coated for MCB DB SPN 8 way fitted with neutral link, earth bar , din rail 230 volt conforming to IS 13032-1991 complete all as specified.
S & F in repairs/replacement double door, sheet metal enclosure, powder coated for MCB DB SPN 4 way fitted with neutral link, earth bar, din rail, 230 volt conforming to IS 13032-1991 complete all as specified.
S & F in repairs/replacement double door, sheet metal enclosure, powder coated for MCB DB TPN 4way fitted with neutral link, earthing bar , din rail, 415 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. Make ; Havells Cat No DHDNTHODAW-04
S & F load line distribution board TPN, Vertical type 4 ways, double door with & including one MCCB 4 pole 63 Amps 10 KA as incommer, powder coated DB for single phase outing and provn for MCCB including necessary Phase bars, earth bar and neutral link, and outgoingh MCB Make : Havells , Cat Part No DHDPTVODRW04 Note: Outgoing MCB will be measured and paid separately.
S & F in repair of MCB SP 6 to 32 Amp, 240V, 10KA C curves all as per site requirement complete all as specified and directed Make-Legrand cat part no.408595 or its equivalent
S & F in repair of MCB SPN 16-32 Amp,240V, 10KA C curves all as per site requirement complete all as specified and directed Make-Legrand cat part no.408617 or its equivalent
S & F in repair of MCB TPN 63 Amps 415V, 10KA C curves all as per site requirement complete all as specified and directed Make-Legrand cat part 408661 or its equivalent
M & L for Submain wiring alongwith earth wire of size 4x10.0 sq. mm + 1x10 sq. mm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor, single core cable drawn in and including PVC Conduit ISI marked, and all accessories as required as specified and as directed. Including taking down old un servicable sub main wairing all as specified and as directed (For DB to DB) Note :(i) Four run of PVC wire and one run of earth wire one run of conduit will be measured and paid as one length.
M & L for Submain wiring alongwith earth wire of size 2x6.0 sq. mm + 1x6 sq. mm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor, single core cable drawn in and including PVC Conduit ISI marked, and all accessories as required as specified and as directed. Including taking down old un servicable sub main wairing all as specified and as directed (For DB to DB) Note :(i) Two run of PVC wire and one run of earth wire one run of conduit will be measured and paid as one length.
M & L for Submain wiring alongwith earth wire of size 2x4.0 sq. mm + 1x4 sq. mm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor, single core cable drawn in and including PVC Conduit ISI marked, and all accessories as required as specified and as directed. Including taking down old un servicable sub main wairing all as specified and as directed (For DB to DB) Note :(i) Two run of PVC wire and one run of earth wire one run of conduit will be measured and paid as one length.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6.00 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron or steel earth lead wire 4 mm dia size by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 3 of SSR part I 2009 including necessary excavation and earth work GI pipe 20mm dia medium grade ISI marked for watering and GI 15mm dia medium grade ISI marked pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated including testing complete.
S&F transparant meter enclosure hinge type for fixing existing single phase meter with 3 Nos NIC seal complet all as specified and directed by Engr -in- Charge. Make L&T
S&F transparant meter enclosure hinge type for fixing existing three phase meter with 3 Nos NIC seal complet all as specified and directed by Engr -in- Charge. Make L&T
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230V, 10-60 AMP,accuracy class-I 50 Hz, conforming to IS13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH single Phase 230 Volt.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230V, 10-60 AMP,accuracy class-I 50 Hz, conforming to IS13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH three Phase 415 Volt.
S&F in repair of switch piano, flush type, 5 amps, 230 volts, single pole, one way (ISI marked) complete specified.
S&F in repair of switch piano, flush type, 15 amps, 230 volts, single pole, one way (ISI marked) complete all as specified.
S&F in repair of sockets outlet multipurpose 2 in 1, 5 Amps flush type confirming to IS all as specified.
S&F in repair of sockets outlet multipurpose 2 in 1 pin, 5 and 15 Amps flush type confirming to IS all as specified.
Supply and laying or fixing or passing through GI pipe, 1100 volts grade heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 Core nominal cross section in service connections Complete all as specified by Engineer-in-Charge.
M/s. Aggarwal Engineers
R K ENTERPRISES
PAWAN KUMAR GOVT. CONTRACTORS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .