Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹3.1 L
EMD Value
₹7,100
Closing Date
19 May 2023, 10:00 amClosed
Ex. Engineer(Elect.)/CNZ
C-Block, Defence Colony- New Delhi-110024
Improvement and development of E.I along with shifting of window/split air conditioners at first floor Nizamuddin Basti Community Centre converted as Dispensary in Ward No 55-S under Central Zone.
2023_SDMC_154115_1
EE(Elect.)/CNZ/2023-24/07-03
Open Tender
Electrical Works
Item Rate
60 days
Ward no. 56-S
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹7,100
24 Jul 2023
15 May 2023
19 May 2023
15 May 2023
19 May 2023
15 May 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as requiredb. 4 Module (125 mmX75 mm)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required 8 Module (125mmX125mm) .
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening ,including making good the damage , connection, testing,commissioning etc.as required.(a) Up to 450 mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a). 8 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole.
Supplying and fixing following rating ,double pole,240 volt,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required.(b) 63 amps
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle).
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 36 KA, FPMCCB
Supplying and fixing brass batten/ angle holder including connection etc. as required.
S/I/T/C of MCCB Sheet Metal Enclosure, 4P, 100-125A
Supply ,Installation, Testing and Commissioning of 1200mm sweeep, BEE 5 Star rated , ceiling fan suitable for 230 V 50 hertz AC Supply without regulator with blades downrod etc. complete as required
Supply of XLPE insulated and PVC sheathed Al. conductor armoured cable 1.1 KV grade confirming to IS 7098 as required. 2 x 10 sq.mm
S/I/T/C of copper pipe for split AC
Shifting of Window Air Conditioner of 1.5 Ton capacity(Removal from existing place and installation in another place in same compound) including top up of gas, servicing and accessories etc. as required.
Shifting of Split Air Conditioner of 1.5 Ton capacity(Removal from existing place and installation in another place in same compound) including top up of gas, servicing and accessories etc. as required(but excluding Copper Pipe).
SITC of single phase monoblock pumpset complete with all accessories workable of 240 Volts 50 Hz AC supply (a) 1 HP (0.75 KW) single phase pumpset head from 12- 30 metre suction and delivery 25X25 mm.
Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
S/I/T/C of LED Tube Type luminiare 20 Watt rating complete with polycarbonate housing Batten integrated electronic driver prewired with high efficient LEDs with the following: (a) Total System Wattage 20 Watt +/- 5%. (b) Luminous Efficieny lumens/watt >= 95 (c ) Power Factor>= 0.95
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .