Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical Work Exp. not as per requirement. |
Tender Value
₹92 L
EMD Value
₹1.8 L
Closing Date
30 Nov 2023, 2:00 pmClosed
Superintending Engineer
Superintending Engineer, E.U.D.C.-1, 57, George Town, Prayagraj
Refer to Tender Description
2023_PVVNV_864001_1
32/SE/EUDC-I-Pra/2023-24
Open Tender
Electrical Works
Lump-sum
90 days
Prayagraj
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,210
Yes
Account Number-0012002100504911
₹1.8 L
Yes
13 Dec 2023
22 Nov 2023
30 Nov 2023
22 Nov 2023
30 Nov 2023
22 Nov 2023
Amount
Construction of 33KV Line from 132/33KV Naini Complex to give supply to newly constructed Rajju Bhaiya (Rajendra Prasad) University, including Carriage, Loading and Unloading of materials from Store Centre Naini to Work Site.
Fabrication, errection, plinting & painting of double pole cable exposure of ST Pole 11 Mtr long including grouting with cement sand and brick balast in 1:4:8 upto 1/6th length for 33KV line with fixing of necessary clamp channel to complete work. (Only ST Poles will be provided by Department rest all material to be arranged by contractor)
Laying of 33KV 3x120 sq mm twin cable shall be parallel each other with an inter axial spacing between two cables 0.25 to 0.40 Mtr. The two cables must be separated by a partition of single brick along with total length upto height of stone slab. The parallel cable are to be laying by digging of trench of size 1050mm deep 750mm wide as per ISS. The cable boxing with brick, sand & stone slab after cable laying filling of trench leveling and ramming. (Only 33 KV 3x120 sq mm Cable will be provided by department rest all material to be provided by contractor)
Laying of 33 KV 3x120 sq mm XLPE cable in 140mm OD PN-4 PE-80 Grade UV stablized HDPE Pipe twin cable shall be parallel each other with an inter axial spacing between two cables 0.25 to 0.40 Mtr. The parallel cable are to be laying by digging trench of size 1050 mm deep 750mm wide as per ISS. (Only 33 KV 3x120 sq mm Cable will be provided by department rest all material to be provided by contractor)
Underground Road crossing for cable laying by manual digging method. (All material to be arranged by contractor)
Laying of 33 KV 3x120 sq mm XLPE cable in G.I. pipe 6" dia after fixing/ laying of suitable size in pucca road/ RCC road. (Only 33 KV 3x120 sq mm Cable will be provided by department rest all material to be provided by contractor)
Fixing of following H.S type cable jointing kits ST/Th, end termination (All Material is to be arranged by contractor)
33KV ST/Th C/J Kit 3x120 sq mm
33 KV end termination out door/Indoor type 3x120 sq mm
High Pressure testing of 33 KV cable with D.C test Voltage to which cable shall with stand on 60 KV for a duration of 5 Min. after completion of laying/joints and terminations. (All Arrangements to be done by contractor and test must be performed under the direct supervision of EE EUDD-Naini)
33 KV cable hoisting on existing /Erected Double pole support with provision of M.S pipe 125 mm dia 3 Mtr long suitable for 3x120 sq mm cable fixing of proper support and its clamping jumpering with Dog conductor properly as per ISS.
Tree cutting small & medium branches cutting Charge.
RCC Framed Structure (Floor Height 3.60M) (Pwd Plinth area rate sch. Item no. 1.1.1), PLINTH AREA= 1X(3X4=12 sq meter) for PPMC. (All material to be arranged by contractor)
Road Restoration charges for footpath side.(All material to be arranged by contractor)
Installation of 33KV PPMC Unit and CVT at Consumer Premises
GANGA ELECTRICALS
M/S Ajay Tripathi
D N S ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .