| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | ₹32.4 L Quoted ₹32.7 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹46.9 L+₹14.2 L (43.4%)Rejected-Finance | ₹46.9 L+₹14.2 L (43.4%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹57.9 L+₹25.2 L (77.0%)Rejected-Finance | ₹57.9 L+₹25.2 L (77.0%) | L3 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | RAHUL ENTERPRISES L1 | R Tech Mech L3 | B5BUILDING SOLUTIONS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance to VRF type AC 12 HP X 2 Nos ODU with 4 Nos of cassette type and 8 Nos high wall type IDU of Carrier make including general servicing of indoor unit and outdoor unit as and when ordered as in preventive maintenance including cleaning, removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure, charging of refrigerant gas etc., complete with all T&P required including scaffolding if required for the smooth and satisfactorily functioning of the AC units complete all as specified and as directed by Engineer-in-Charge. Location: RUSTOM HANGER
NOTE :-
Replacement of compressors, condenser fan motors, blower and motor, PCBs, solenoid valves, drain pumps, refrigerant gas, compressor oil etc., if required shall be measured and paid separately. | 11 | EACH JOB | 11,000 ₹1,21,000 | 6,000 ₹66,000 Lowest | 15,000 ₹1,65,000 |
| 2.00 | Comprehensive maintenance to VRF type AC 18 HP x 2, 16 HP x 2, and 12 HP x 1 Nos ODU with 35 Nos high wall type IDU of Carrier make including general servicing of indoor unit and outdoor unit as and when ordered as in preventive maintenance including cleaning, removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure, charging of refrigerant etc all complete with all T&P required including scaffolding if required for the smooth and satisfactorily functioning of the AC units complete all as specified and directed by Engineer-in-Charge.
Location: DEBEL & RUSTOM HANGER
NOTE :-
Replacement of compressors, condenser fan motors, Blower and motor, PCBs, solenoid valves, drain pumps, refrigerant gas, compressor oil etc., if required shall be measured. | 11 | EACH JOB | 10,500 ₹1,15,500 | 6,000 ₹66,000 Lowest | 16,500 ₹1,81,500 |
| 3.00 | Comprehensive maintenance to VRF type AC 20 HP X 1, 18 HP X 8, 16 HP X 2, 14 HP X 2 and 10 HP X 4 Nos ODU with 148 Nos of cassette type IDU of Carrier make including general servicing of indoor unit and outdoor unit as and when ordered as in preventive maintenance including cleaning, removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure, charging of refrigerant etc complete with all T&P required including scaffolding if required for the smooth and satisfactorily functioning of the AC units complete all as specified and directed by Engineer-in-charge.
Location : DEBEL New Bldg
NOTE :-
Replacement of compressors, condenser fan motors, blower and motor, PCBs, solenoid valves, drain pumps, refrigerant gas, compressor oil etc., if required shall be measured and paid separately under relevant items. | 11 | EACH JOB | 20,000 ₹2,20,000 | 6,000 ₹66,000 Lowest | 30,000 ₹3,30,000 |
| 4.00 | Comprehensive maintenance to VRF type AC 16 HP X 4, and 12 HP X 12 Nos ODU with 40 Nos of cassette type IDU of Voltas make including general servicing of indoor unit and out door unit as and when ordered as in preventive maintenance including cleaning, removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure, charging of refrigerant etc complete with all T&P required including scaffolding if required for the smooth and satisfactorily functioning of the AC units complete all as specified and directed by Engineer-in-Charge.
Location: DEBEL New Bldg
NOTE :-
Replacement of compressors, condenser fan motors, blower and motor, PCBs, solenoid valves, drain pumps, refrigerant gas, compressor oil etc., if required shall be measured and paid separately under relevant items. | 11 | EACH JOB | 12,000 ₹1,32,000 | 6,000 ₹66,000 Lowest | 17,000 ₹1,87,000 |
| 5.00 | General servicing and maintenance of package / cassette type AC of any make and capacity upto 5.5 TR to 8.5 TR including general servicing of indoor and outdoor unit as and when ordered as in preventive maintenance including cleaning, removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure, charging of refrigerant etc complete with all T&P required including scaffolding if required for the smooth and satisfactorily functioning of the AC unit complete all as specified and directed by Engineer-in-Charge. Location- DEBEL / RUSTOM
NOTE :-
Replacement of compressor and spares such as starting capacitor, running capacitor, fan motor, blowers, PCBs, Refrigerant, drain pump, sensors, oil etc., if required shall be measured and paid separately under relevant items. | 30 | EACH JOB | 2,000 ₹60,000 Lowest | 6,000 ₹1,80,000 | 3,500 ₹1,05,000 |
| 6.00Supply and fixing of fixed speed compressor of VRF unit after disconnecting the electrical and refrigerant pipe connection, replace the compressor, reconnect the electrical and refrigerant pipe connection after flushing the system thoroughly with N2 gas, pressure testing for leakages, vaccumising , gas charging and re-commissioning the VRF unit all as required and as per standards complete all as specified and as directed. NOTE :- Old compressor taking down/ removal shall be replaced with the same make and model. | ||||||
| 6.01 | (a) 10 HP to 14 HP | 6 | EACH | 32,000 ₹1,92,000 | 1,75,000 ₹10,50,000 | 25,000 ₹1,50,000 Lowest |
| 6.02 | (b) 16 HP to 26 HP | 6 | EACH | 34,000 ₹2,04,000 | 2,05,000 ₹12,30,000 | 29,000 ₹1,74,000 Lowest |
| 7.00 | Supply and fixing in replacement of outdoor fan motor DC for VRF unit complete, including taking down of old unserviceable one complete all as specified and as directed. | 2 | EACH | 4,000 ₹8,000 Lowest | 10,000 ₹20,000 | 12,000 ₹24,000 |
| 8.00 | Supply and fixing in replacement of compressor IPDU (PCB) for VRF unit complete, including taking down of old unserviceable one complete all as specified and as directed. | 2 | EACH | 2,500 ₹5,000 Lowest | 10,000 ₹20,000 | 20,000 ₹40,000 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
9 Feb 2026, 6:00 pmClosed
MAJOR ANIRUDDHA SUBBA
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
REPAIRS AND MAINTENANCE OF CENTRAL PACKAGE TYPE AC PLANTS AND CONNECTED WORKS AT ADE DEBEL UNDER GE I R AND D EAST BANGALORE
2026_MES_747289_1
8677/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY c(i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹96,000
Yes
27 Mar 2026
20 Jan 2026
11 Feb 2026
20 Jan 2026
9 Feb 2026
3 Feb 2026
20 Jan 2026 - 2 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive maintenance to VRF type AC 12 HP X 2 Nos ODU with 4 Nos of cassette type and 8 Nos high wall type IDU of Carrier make including general servicing of indoor unit and outdoor unit as and when ordered as in preventive maintenance including cleaning, removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure, charging of refrigerant gas etc., complete with all T&P required including scaffolding if required for the smooth and satisfactorily functioning of the AC units complete all as specified and as directed by Engineer-in-Charge. Location: RUSTOM HANGER
NOTE :-
Replacement of compressors, condenser fan motors, blower and motor, PCBs, solenoid valves, drain pumps, refrigerant gas, compressor oil etc., if required shall be measured and paid separately. | 11 | EACH JOB | - | - |
| 2 | Comprehensive maintenance to VRF type AC 18 HP x 2, 16 HP x 2, and 12 HP x 1 Nos ODU with 35 Nos high wall type IDU of Carrier make including general servicing of indoor unit and outdoor unit as and when ordered as in preventive maintenance including cleaning, removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure, charging of refrigerant etc all complete with all T&P required including scaffolding if required for the smooth and satisfactorily functioning of the AC units complete all as specified and directed by Engineer-in-Charge.
Location: DEBEL & RUSTOM HANGER
NOTE :-
Replacement of compressors, condenser fan motors, Blower and motor, PCBs, solenoid valves, drain pumps, refrigerant gas, compressor oil etc., if required shall be measured. | 11 | EACH JOB | - | - |
| 3 | Comprehensive maintenance to VRF type AC 20 HP X 1, 18 HP X 8, 16 HP X 2, 14 HP X 2 and 10 HP X 4 Nos ODU with 148 Nos of cassette type IDU of Carrier make including general servicing of indoor unit and outdoor unit as and when ordered as in preventive maintenance including cleaning, removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure, charging of refrigerant etc complete with all T&P required including scaffolding if required for the smooth and satisfactorily functioning of the AC units complete all as specified and directed by Engineer-in-charge.
Location : DEBEL New Bldg
NOTE :-
Replacement of compressors, condenser fan motors, blower and motor, PCBs, solenoid valves, drain pumps, refrigerant gas, compressor oil etc., if required shall be measured and paid separately under relevant items. | 11 | EACH JOB | - | - |
| 4 | Comprehensive maintenance to VRF type AC 16 HP X 4, and 12 HP X 12 Nos ODU with 40 Nos of cassette type IDU of Voltas make including general servicing of indoor unit and out door unit as and when ordered as in preventive maintenance including cleaning, removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure, charging of refrigerant etc complete with all T&P required including scaffolding if required for the smooth and satisfactorily functioning of the AC units complete all as specified and directed by Engineer-in-Charge.
Location: DEBEL New Bldg
NOTE :-
Replacement of compressors, condenser fan motors, blower and motor, PCBs, solenoid valves, drain pumps, refrigerant gas, compressor oil etc., if required shall be measured and paid separately under relevant items. | 11 | EACH JOB | - | - |
| 5 | General servicing and maintenance of package / cassette type AC of any make and capacity upto 5.5 TR to 8.5 TR including general servicing of indoor and outdoor unit as and when ordered as in preventive maintenance including cleaning, removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure, charging of refrigerant etc complete with all T&P required including scaffolding if required for the smooth and satisfactorily functioning of the AC unit complete all as specified and directed by Engineer-in-Charge. Location- DEBEL / RUSTOM
NOTE :-
Replacement of compressor and spares such as starting capacitor, running capacitor, fan motor, blowers, PCBs, Refrigerant, drain pump, sensors, oil etc., if required shall be measured and paid separately under relevant items. | 30 | EACH JOB | - | - |
| 6Supply and fixing of fixed speed compressor of VRF unit after disconnecting the electrical and refrigerant pipe connection, replace the compressor, reconnect the electrical and refrigerant pipe connection after flushing the system thoroughly with N2 gas, pressure testing for leakages, vaccumising , gas charging and re-commissioning the VRF unit all as required and as per standards complete all as specified and as directed. NOTE :- Old compressor taking down/ removal shall be replaced with the same make and model. | |||||
| 6.01 | (a) 10 HP to 14 HP | 6 | EACH | - | - |
| 6.02 | (b) 16 HP to 26 HP | 6 | EACH | - | - |
| 7 | Supply and fixing in replacement of outdoor fan motor DC for VRF unit complete, including taking down of old unserviceable one complete all as specified and as directed. | 2 | EACH | - | - |
| 8 | Supply and fixing in replacement of compressor IPDU (PCB) for VRF unit complete, including taking down of old unserviceable one complete all as specified and as directed. | 2 | EACH | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_839248.xls
BOQ • 2.04 MB
8677Tender.pdf
Tender Documents • 0.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .