| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.7 L+₹1.2 L (5.17%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹26.9 L+₹3.5 L (14.8%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹56,952
Closing Date
24 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KHUMBATHANG
GE KHUMBATHANG
REPAIR REPLACEMENT OF MISCELLANEOUS ITEMS OF VARIOUS E M INSTALLATIONS AND REPAIR REPLACEMENT OF VARIOUS E M HEATING AND COOLING DEVICES AT KHUMBATHANG IN THE AOR OF AGE E M UNDER GE KHUMBATHANG
2023_MES_606134_1
GE/KHU-35/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE KHUMBATHANG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE KHUMBATHANG
₹56,952
4 Sept 2023
27 Jun 2023
25 Jul 2023
27 Jun 2023
24 Jul 2023
11 Jul 2023
Amount
S&F in repair of booster pump with vessel of capacity 1 HP with all accessories including water seal complete all as specified and directed by Engr-in- Charge.
Repair and replacement of auto voltage regulator complete with wire connection and connecting to existing field coil 24 volts for capacity of 125 to 600 KVA Make: Crompton Greaves/ Kirloslar/Cummins complete all as specified and directed by Engr-in- Charge.
S & F low engine oil pressure switch/sensor for 12/24 volts 3.5 to 10 Kg/Sq cm for DG sets of capacity 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in- Charge.
S&F in replacement lead acid power pack unit of capacity 12 volts 180 AH of DG Sets complete all as specified and directed by Engr-in- Charge
Supply and fixing of Turbo Charger Assy of DG set of capacity 320 KVA to 600 KVA incl taking down old u/s Turbo Charger complete all as specified and directed by Engr-in- Charge
S&F in repairs cable jointing kit for 11 KV (Earthed) grade cable for out door termination cold shrink type joint complet with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed by Engr-in- Charge
S&F in repairs cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complet with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm all as specified and directed.
S & F in repair automatic star delta starter 415 V 3 phase suitable for 20 HP motor complete all as specified and directed by Engr-in- Charge
M & L for changing the locking arrangement and refixing the doors of LT panels by welding and painting the outer and inner surface of panel complete all as specified and directed by Engr-in- Charge
Disconnecting from circuit/bus bar LT panel and taking out cables for extension of loop/passing through pipe reconnection with circuit and tightening of connections by using suitable size of lugs/thimbles complete all as specified and directed by Engr-in- Charge
S&F in replacement of existing unserviceable onload changeover switch any size & capacity with onload changeover switch 4 pole 630 Amps side handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole, 415 Volt , adjutable type, 400 Amps breaking capacity 36KA Thermal magnetic and Microprocessor release with thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 415 Volt , adjutable type, 250 Amps breaking capacity 36KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge
S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 415 Volt , adjutable type, 160 Amps breaking capacity 36 KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
Supply and laying, jointing & testing in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor,1100 volt grade laid in trenches,ducts,drawn through pipes across the road/path/along .poles/floors/equipment etc of size 300 sq mm 3.5 core. complete all as specified and directed by Engr-in- Charge
All as per item srl item No. 15 here-in-before but of size 120 sqmm 3.5 core
All as per item srl item No. 15 here-in-before but of size 95 sqmm 3.5 core
All as per item srl item No. 15 here-in-before but of size 70 sqmm 3.5 core
S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 125 Amps 16KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 63 Amps 16KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
Supply & Fixing in repair VCB battery charger 415 V ripple free DC output capacity 20 AH to 180 AH max charging current 15 A suitable for charging series connected dry cell cap 12V amp 20 AH to 150 AH complete all as specified
Supply & Fixing 12 V 80-100 AH dry rechargeable maintenance free battery suitable for VCB power pack complete all as specified and directed by Engr-in- Charge.
Supply & Fixing sheet metal Enclosures DB's single pole and neutral double door of 4 ways with 200 Amp rated bus bar complete all as specified and directed by Engr-in- Charge.
Supply & Fixing sheet metal Enclosures DB's single pole and neutral double door of 8 ways with 200 Amp rated bus bar complete all as specified and directed by Engr-in- Charge.
Supply & Fixing sheet metal Enclosures DB's single pole and neutral double door of 12 ways with 200 Amp rated bus bar complete all as specified and directed by Engr-in- Charge.
Supply and fixing in repair LT line separator suitable for three phase four wire water proof, weather proof, shock proof, Resistant to chemicals , robust construction easy to install low maintenance and fine uniform finish all as directed by Engr-in-charge.
S&F in repair relay 8 pin MY2N , 240 volt AC suitable for electric based CHS and Hot water generator incl taking down old one complete all as specified and directed by Engr-in- Charge.
S&F in repair relay 8 pin LY2N , 240 volt AC suitable for electric based CHS and Hot water generator incl taking down old one complete all as specified and directed.
S&F in repair relay 14 pin MY4N, 240 volts suitable for electric based CHS and Hot water generator incl taking down old one complete all as specified and directed by Engr-in- Charge.
Repair of body leakage of electric Hamam of capacity 45 Ltr , steel body rectangular/cylindrical type with thermostates for auto cut and change of burnt heating element of capacity 1.5 KW complete all as specified and directed by Engr-in- Charge.
Repair of body leakage of electric hamam of capacity 25 Ltr, steel body rectangular/cylindrical type with thermostates for auto cut and change of burnt heating element of capacity 1 KW complete all as specified and directed by Engr-in- Charge.
M&L for replacement of step controller card (4 Nos relay) alongwith step controller display with all connected accessories of the control system of electrical CHS and Hot water generator system as required at site complete all as specified and directed.
M&L for replacement of step controller card (8 Nos relay) alongwith step controller display with all connected accessories of the control system of electrical CHS and Hot water generator system as required at site complete all as specified and directed.
M&L for replacement of damaged aluminium cladding of pipe off size complete as required at site complete all as specified and directed.
M&L for replacement of damaged nitrile rubber insulation of 16mm thick and 1 mtr wide over pipes of CHS of any size as required at site complete all as specified and directed by Engr-in- Charge.
S&F in replacement of reciprocating/rotary compressor including refilling of refrigirant R-134a brazing and bring to be serviceable condition and testing suitable for 500 ltr Deep Freezer complete all as specified and directed by Engr-in- Charge.
S&F in replacement of reciprocating /rotary compressor including refilling of refrigirent R-134 a, brazing and bring to be serviceable condition and testing suitable for 300 ltr Deep Freezer complete all as specified and directed.
S&F in replacement of reciprocating/rotary compressor including refilling of refrigirent, brazing and bring to be serviceable condition and testing suitable for 200 tr Deep Freezer complete all as specified and directed by Engr-in- Charge.
S&F in replacement of wall mounted fan coil unit of capacity 1.5/2 TR (4500 K Cal/Hrs 600 Cfm) complete all as specified and directed by Engr-in- Charge.
Supply, installation, testing and commissioning of wall mounted type heating panels of rating 450 W and suitable size as per site requirement alogwith all connected accessories, complete all as specified and directed by Engr-in- Charge.
S&F in replacement of heating element AC 230 volt, triangle/round type of rating 1500 watt suitable for geyser/Hamam as per sample, complete all as specified and directed by Engr-in- Charge.
Supply and fixing in repair heating element AC 230 volt, triangle/round type of rating 2000 watt suitable for geyser/Hamam as per sample complete all as specified and directed by Engr-in- Charge.
Material and labour for repair of Water heater storage type, electric based,capacity 25 litres rate included in change of themostat,stainless steel tank,heating element complete all as specified and directed by Engr-in- Charge.
Supply & Fixing Gun metal Ball valve of 20 mm dia complete all as specified and directed by Engr-in- Charge.
M&L for replacement of unsv diesel fired burner of heat output capacity 50000 Kcal/hr for standalone CHS complete all as specified and directed by Engr-in- Charge.
Supply & Fixing in repair 500 LPD solar water tank complete all as specified and directed by Engr-in- Charge.
Supply & Fixing in repair solar plate gasket complete all as specified and directed by Engr-in- Charge.
Supply & Fixing in repair borosilicate glass heater tube suitable for 500 LPD solar water heating system complete all as specified and directed by Engr-in- Charge.
Supply & Fixing in repair copper tubing 8mm/12mm dia suitable for hot and cool Air conditioning connection complete all as specified and directed by Engr-in- Charge.
Deduct Credit for Demolished/Dismantled material Rs (-) 1,29,172.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
M/s Raj Construction
national engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .