| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-AOC NOT AVAILABLE | ₹3.4 Cr Quoted ₹3.5 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹3.6 Cr+₹10.4 L (2.97%)Rejected-Finance | ₹3.6 Cr+₹10.4 L (2.97%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹3.8 Cr+₹29.7 L (8.50%)Rejected-Finance AT ROAD MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | 786102 | ₹3.8 Cr+₹29.7 L (8.50%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹3.8 Cr+₹31.4 L (8.98%)Rejected-Finance | ₹3.8 Cr+₹31.4 L (8.98%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹4.0 Cr+₹54.9 L (15.7%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | ₹4.0 Cr+₹54.9 L (15.7%) | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | M/s PRABIR ENTERPRISE L5 | M/S P R SINGH AND SONS L8 | M/S R G Construction L3 | LUMOS INFRA PVT LTD L4 | Phoenix Infra L9 | SATYA CHANGMAI L1 | M/s T.K. ENTERPRISE L7 | ARRYA ENTERPRISES L6 | SRC COMPANY INFRA PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00B/R PORTION | ||||||||||||
| 2.00 | Construction of 01 block of CAR and SCOOTER SHED in Single storey configuration with RCC framed structure and permanent specification, complete all as specified and as shown in drawing. | 11 | Each Block | 8,00,000 ₹88,00,000 | 8,93,200 ₹98,25,200 | 10,22,500 ₹1,12,47,500 | 9,95,000 ₹1,09,45,000 | 9,90,000 ₹1,08,90,000 | 6,20,000 ₹68,20,000 Lowest | 8,00,000 ₹88,00,000 | 7,00,000 ₹77,00,000 | 8,60,000 ₹94,60,000 |
| 3.00 | Taking down chowkat with shutters of any description without taking off shutters from frame of area not exc. 1.50 sqm each, complete all as specified and directed. | 308 | Each | 40 ₹12,320 Lowest | 100 ₹30,800 | 60 ₹18,480 | 65 ₹20,020 | 100 ₹30,800 | 60 ₹18,480 | 134 ₹41,272 | 122 ₹37,576 | 400 ₹1,23,200 |
| 4.00 | Taking down chowkat with shutters of any description without taking off shutters from frame of area exc. 1.50 sqm but n. exc. 4.00 sqm each, complete all as specified and directed. | 308 | Each | 40 ₹12,320 Lowest | 105 ₹32,340 | 110 ₹33,880 | 115 ₹35,420 | 150 ₹46,200 | 75 ₹23,100 | 166 ₹51,128 | 155 ₹47,740 | 450 ₹1,38,600 |
| 5.00 | Taking down shutters of any description exc. 1.0 Sqm but n. exc. 2.0 Sqm each, complete all as specified and directed. | 88 | Each Leaf | 100 ₹8,800 | 90 ₹7,920 | 55 ₹4,840 | 56 ₹4,928 | 80 ₹7,040 | 45 ₹3,960 Lowest | 133 ₹11,704 | 122 ₹10,736 | 100 ₹8,800 |
| 6.00 | Taking down shutters of any description exc. 1 .0 Sqm but n. exc. 2.0 sqm each and refixing the same in the same opening, complete all as specified and directed. | 44 | Each Leaf | 250 ₹11,000 | 120 ₹5,280 | 75 ₹3,300 | 76 ₹3,344 | 100 ₹4,400 | 45 ₹1,980 Lowest | 155 ₹6,820 | 144 ₹6,336 | 450 ₹19,800 |
| 7.00 | Taking down chowkat or frames exc 1.5 sqm but n.exc 4 sqm, complete all as specified and directed. | 44 | Each | 60 ₹2,640 | 130 ₹5,720 | 55 ₹2,420 | 58 ₹2,552 | 250 ₹11,000 | 50 ₹2,200 Lowest | 55 ₹2,420 | 77 ₹3,388 | 500 ₹22,000 |
| 8.00 | S&F pressed steel frames 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified and directed. | 214 | RM | 1,200 ₹2,56,800 | 1,350 ₹2,88,900 | 650 ₹1,39,100 | 640 ₹1,36,960 | 700 ₹1,49,800 | 870 ₹1,86,180 | 444 ₹95,016 | 555 ₹1,18,770 | 430 ₹92,020 Lowest |
| 9.00 | S&F pressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified and directed. | 214 | RM | 1,100 ₹2,35,400 | 1,250 ₹2,67,500 | 400 ₹85,600 | 410 ₹87,740 | 600 ₹1,28,400 | 850 ₹1,81,900 | 777 ₹1,66,278 | 666 ₹1,42,524 | 390 ₹83,460 Lowest |
| 10.00 | M&L for plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregates) for filling pressed steel frame, , complete all as specified and directed. | 4 | Cum | 6,400 ₹25,600 | 7,500 ₹30,000 | 560 ₹2,240 Lowest | 565 ₹2,260 | 7,500 ₹30,000 | 5,300 ₹21,200 | 8,888 ₹35,552 | 7,000 ₹28,000 | 10,000 ₹40,000 |
Tender Value
₹4.3 Cr
EMD Value
₹5.0 L
Closing Date
28 Oct 2025, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
ADDN ALTN TO MARRIED ACCN AT AF STN CHABUA
2025_MES_716977_1
88681/CHAB/E8
Open Tender
Civil Works
Item Rate
545 days
Chabua
As per tender documents
8 documents required · 8 mandatory
₹2,000
GE (AF) Chabua
₹5.0 L
Yes
31 Dec 2025
26 Jun 2025
30 Oct 2025
31 Jul 2025
28 Oct 2025
21 Oct 2025
Amount
B/R PORTION
Construction of 01 block of CAR and SCOOTER SHED in Single storey configuration with RCC framed structure and permanent specification, complete all as specified and as shown in drawing.
Taking down chowkat with shutters of any description without taking off shutters from frame of area not exc. 1.50 sqm each, complete all as specified and directed.
Taking down chowkat with shutters of any description without taking off shutters from frame of area exc. 1.50 sqm but n. exc. 4.00 sqm each, complete all as specified and directed.
Taking down shutters of any description exc. 1.0 Sqm but n. exc. 2.0 Sqm each, complete all as specified and directed.
Taking down shutters of any description exc. 1 .0 Sqm but n. exc. 2.0 sqm each and refixing the same in the same opening, complete all as specified and directed.
Taking down chowkat or frames exc 1.5 sqm but n.exc 4 sqm, complete all as specified and directed.
S&F pressed steel frames 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified and directed.
S&F pressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregates) for filling pressed steel frame, , complete all as specified and directed.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
S&F factory made 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided in square with plain, chamfered or rounded mitred and rebated sash bars any number, edges of framing plain, chamfered or rounded , fitted with cut and mitered beads for securing glass etc., complete all as specified in SSR Part I section 8, clause 8.24 ( a ) fitted to chowkat, complete all as specified and directed.
S&F wood grain finished solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube in opening, complete all as specified and as directed.
S&F factory made wood grain finished solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck in side with solvent cement for styles and plain colour PVC sheet for top rail ,lock rail & bottom rail on either sides and as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading, and joint together with solvent cement, complete all as specified and as directed.
S&F 150 mm long anodized aluminium barrel tower bolt of extruded section, complete all as specified and as directed.
S&F 200 mm long anodized aluminium barrel tower bolt of extruded section, complete all as specified and as directed.
S&F 150 mm long anodized aluminium handles, cast type, complete all as specified and as directed.
S&F 100 mm stainless steel butt hinges medium weight cold rolled mild steel and fixed, complete all as specified and directed.
S&F 300mm long aluminium anodized sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, complete all as specified and directed.
S&F framed work such as grills, grating etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework or water tanks and similar work confirming to Fe 290 Gde-E-165, complete all as specified and directed.
S&F powder coated aluminium window shutters in three track sliding (whichever the case may be ordered to sliding horizontally or vertically) with two or more shutters with sliding arrangement with two or more shutter rubber beading and glazing clips using aluminium sections weighing not less than 0.55 Kg/Mtr etc complete and inclusive of necessary hardware i.e. locking mechanism, handle and 4.8mm thick selcted quality glass for glazing and stainless steel wire cloth 0.71mm dia with width of aperture 1.18mm including necessary gasket / neoprene / rubber packing / beading etc., complete all as specified and directed. Note :- Sliding track includes two track of glazing and one track of mosquito net.
S&F powder coated aluminium ventiator with louvers with partially guaged shutter using 5 mm thick x 10 cm wide frosted glass strips with rubber beading and glazing clips etc using aluminium sections weighing not less than 0.55 Kg/M including fosted glass louvers and allied items to facilitate louver action etc., complete all as specified and as directed.
Dismantling asbestos cement (corrugated or semi-corrugated etc.) sheets in roof coverings, complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section, in any position of framed work, complete all as specified and directed.
Dismantling timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in framed work, complete all as specified and directed.
M&L for MS structural steel work, framed as in trusses, purlins, rafter, post, cleats etc. conforming to grade E-250 (Fe-410W, quality A) including shaped washers including necessary cutting required length, notching drilling, riveting and or welding or connecting with nut bolts with angle cleats, fish plate, gusset plate and also erecting in true position, complete all as specified and directed.
S&F gusset plates, angle, cleats, etc. incl necessary welding drilling for fixing, complete all as specified and directed.
S&F prepainted galvalume aluminium zinc coating AZ-150 GI based corrugated steel sheet 0.50 mm thick of camouflage pattern having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or 'J'/'L' hooks, complete all as specified and directed.
S&F prepainted galvalume aluminium zinc coating AZ-150 GI based plain steel sheet 0.50 mm thick of camouflage pattern having tensile strength of 550 Mpa as in ridges, gutters, facia etc., fixed with self tapping screws or 'J'/'L' hooks, complete all as specified and directed.
M&L for preparation of newly steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for preparation of newly wooden surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6 m mean radius built in CM (1:6), complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4), complete all as specified and directed.
M&L for PCC (1:2:4) type B -0 (using 12.5mm graded stone aggregate) as in coping and kerbs etc. including necessary form work etc., complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including racking out joints hacking for key and scrubbing down with water etc., complete all as specified and as directed.
M&L for 5 mm thick rendering in CM (1:3) on ceiling and finished surface fair & even, complete all as specified and as directed.
M&L for 15mm thick rendering in CM (1:4) (in two coats 10mm thick in CM (1:4) and 5mm thick finishing coat in CM (1:4) using water proofing compound as per manufacturer's instruction) on stone masonry surfaces or surface other than fair face of brick work or on one side of lathing, complete all as specified and as directed. Note : Integral water proofing compound will be measured and paid for separately.
M&L for 10mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces, complete all as specified and directed.
Supply only Integral waterproofing compound, complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of OBD of approved tint and pattern over one coat of primer over a coat of 2mm thick wall care putty on wall, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed.
Complete removal of existing treatment and M&L for preparation of walls and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty etc., complete all as specified and directed.
Complete removal of existing treatment and M&L for preparation of walls and applying three coats of white wash after and inclusive of filling depressions with wall care putty etc., complete all as specified and directed.
Complete removal of existing treatment and M&L for preparation of ceiling and applying two coats of white wash after and inclusive of filling depressions with white cement etc., complete all as specified and directed.
M&L for preparation of old painted wooden surface and applying one coat of synthetic enamel paint of any description exc. 10 cm width or girth including making good existing cracks etc.with wood filler, complete all as specified and as directed.
Complete removal of existing treatment of old plastered surface of wall and finishing with acrylic smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) in any shade after washing with water and filling depression with external putty etc., complete all as specified and directed. Note :- Shade of colour shall be approved by GE.
M&L for preparation of newly plastered surfaces of wall and finishing walls with acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) in any shade, complete all as specified and directed. Note :- Shade of colour shall be approved by GE.
S&F stainless steel wire cloth 0.36mm nominal dia. of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F in repair stainless steel wire cloth 0.36mm nominal dia. of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
Taking down carefully existing bituminous felt including plaster lime or concrete of any thickness, and cleaning of the surface of roofs, terrace including flushing and junction of parapets, kerb walls, PCC fillets benching etc. with wire brushes removal of any vegetations and making good the cracks/voids using PCC 1:2:4 type B1 (Using 20mm graded stone aggregate) and removing of rubbish outside ministry of defence land of any lead, complete all as specified and directed.
M&L for rendering 10mm thick on existing concrete surfaces of roof in CM (1:4) mixed with water proofing compound as per manufacturer's instruction and finished surface even and smooth to receive water proofing treatment complete without using extra cement at any height, complete all as specified and directed. Note:- WPC shall be measured and paid for separately.
M&L for one coat of bituminous primer over cleaned surface @ 0.40 Ltr per sqm and over one coat of polymeric modified bitumen 85/25 @ 1.2 Kg/ Sqm over bituminous primer then followed by APP modified polymeric membrane 3 mm thick minimum weight 3.6 Kg per Sqm reinforced with polyester non woven fabric (weighting not less than 150 gm per sqm) laid as per the manufacturer's instruction with longitudinal overlap of 75mm and transverse overlap of 100mm , joints/lap sealed with torch application and applying one coat of polymeric modified bitumen 85/25 @ 1.2Kg/Sqm and applying one coat of aluminium paint, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar, complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors and pavings n.exc. 15 cm thickness (above or below GL) complete inclusive of removal of debris out side defence land, complete all as specified and as directed.
M&L for 25 mm thick PCC (1:2:4) type B-1, (Using 20 mm graded stone aggregates) as in levelling course / sub base, complete all as specified and directed.
M&L for 20-25mm thick Pre-polished machine cut kota stone slab of size 550x550mm in flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab inclusive of final cleaning upto desired finish over including 20 mm thick screed bed in CM (1:6), complete all as specified and directed.
M&L for 20-25mm thich pre-polished machine cut kota stone slab for steps/treads of stair case in single piece with two straight engraved lines laid over cement screed base laid and jointed with gray cement slurry mixed with pigments to match the shade of slab inclusive of final cleaning upto desired finish after fixing over including 15 mm thick screed bed in CM (1:6), complete all as specified and directed.
M&L for 20-25mm thich pre-polished machine cut kota stone slab for risers of stair case in single piece laid over cement screed base laid and jointed with gray cement slurry mixed with pigments to match the shade of slab inclusive of final cleaning upto desired finish after fixing over including 10 mm thick screed bed in CM (1:4), complete all as specified and directed.
M&L for 16-20 mm thick pre-polished machine cut kota stone slab of size 550 x500mm in skirting dado and pillars laid over cemented screed and jointed with gray cement slurry mixed with pigments to match the shade of the slab inclusive of final cleaning uoto desired finish after fixing over including 10 mm thick screed bed in CM (1:4), complete all as specified and directed.
M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) in basin platform and partition inclusive of cutting chases / holes if ordered as counter of wash basin platforms and like fixed with cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
Dismantling floor hearth and wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises, complete all as specified and directed.
M&L for glazed coloured ceramic tiles of size 600 x 300 x 7-8 mm thick on vertical surfaces, set and jointed in neat cement slurry and pointed with white cement with pigment to match the coloured tiles including 10 mm thick rendering in CM (1:4) for vertical sub base complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm , in floor etc and jointed in neat cement slurry and pointed in white cement or coloured cement to match the shade of tile over and including 15 mm thick screed bed layer in CM (1:6), complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm , in floor etc and jointed in neat cement slurry and pointed in white cement or coloured cement to match the shade of tile over and including 15 mm thick screed bed layer in CM (1:6), complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm , in skirting etc and jointed in neat cement slurry and pointed in white cement or coloured cement to match the shade of tile over and including 10 mm thick baking coat in CM (1:4), complete all as specified and directed.
M&L for providing 75 mm thick PCC (1:3:6) type C-2 (using 40 mm graded stone aggregates) as in plinth protection and finishing surface even and smooth without using extra cement including joints @every 1.2m filled with mastic bituminous filler 10mm wide and 25mm deep, complete all as specified and directed.
S&F in repairs water closet (Squatt Pattern) complete including provn of cement concrete bedding Orissa pattern size 580x440mm white integral foot rests (excluding flush pipe or flushing cisterns) including connection to trap and flushing pipe anti syphonage pipe etc and making good to floor, complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan ( pedestal pattern) white (including two Nos fixing bolts incl PVC seat cover but excluding flushing cistern and flush pipe) complete including making good to floor with and including fixing of P or S trap, complete all as specified and directed.
S&F in repairs PVC High/Low level flushing cistern 10 litres capacity including all fittings i.e. float valve, siphon, flush pipe, brackets, complete all as specified and directed.
S&F in repair vitreous china wash hand basin, (white), flat back of size 550x400 mm with and including two CI brackets, brass chromium plated incl waste coupling fittings and PVC waste pipe, complete all as specified and as directed.
S&F in repairs PVC connections 15mm dia with brass nut on both ends and washers 450mm long, complete all as specified and directed.
S&F in repairs 15 mm dia bore cast copper alloy chromium plated angle cock/stop cock with long shank and cup (concealed type) screwed down high pressure with capstan head, screwed both ends for iron pipes or for union and fixed, complete all as specified and as directed.
S&F in repairs brass chromium plated over head shower rose with arm 125 mm size with long body with swivel joint including fixing to steel pipe or union, complete all as specified and as directed.
S&F in repairs bib taps CP brass fancy type with crutch or butterfly handle screwed down screwed for iron pipe for brass ferrule 15 mm dia., complete all as specified and directed.
S&F in repair stop valves cast copper alloy chromium plated fancy type, screwed down, high pressure with butterfly handle, screwed both ends for iron pipe or for unions 15mm bore, complete all as specified and directed.
S&F 15 mm bore galvanized tubes medium grade with all fittings and fixed complete to walls and ceiling or laid in floor ordered concealed or on face including cutting chases and making good when ordered to be concealed etc including taking up or down steel tubing and connections including cleaning for re-fixing or removal to store, complete all as specified and directed.
S&F 20 mm bore galvanized tubes medium grade with all fittings and fixed complete to walls and ceiling or laid in floor ordered concleaed or on face etc including cutting chases and making good when ordered to be concealed including taking up or down steel tubing and connections including cleaning for re-fixing or removal to store, complete all as specified and directed.
S&F in repairs 15 mm size fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed, complete all as specified and directed.
S&F in repairs grating doom 100 mm dia of stainless steel, with/without hole, complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks 1000 litres capacity 03 layers (cylindrical vertical with closed top as aproved by GE) hoisted and fixed in position all as specified in SSR Part - I including dismantling the existing water tank etc., complete all as specified and directed.
Disconnecting existing tanks exc 500 Ltr but not exc 1000 litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and directed.
S&F in repairs 20 mm size ball PTMT valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed.
S&F in repairs 20 mm size gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
S&F in repairs Waste pipe any dia (32/40mm) 1.0 mtr long, complete all as specified and directed.
S&F in repair two way bib taps CP brass fancy type with crutch or butterfly handle screwed down screwed for iron pipe for brass ferrule 15 mm dia of approved make, complete all as specified and directed.
S&F in repair health faucet of CP brass suitable for 15 mm dia pipe with 1.25 metre long flexible tube and CP brass wall hook including making connections and fixed in position, complete all as specified and directed.
S&F in repair brass CP mixer 15mm bore for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed.
Demolition and breaking up drain pipes 75mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed.
S&F 110mm dia UPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 75mm dia UPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
S&F 110mm bore UPVC (SWR) bends any radius, complete all as specified and directed.
S&F 75mm bore UPVC (SWR) bends any radius, complete all as specified and directed.
S&F UPVC (SWR) vent cowl 75 mm bore, complete all as specified and directed.
S&F 75mm bore UPVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed.
S&F in repair 20mm dia. fancy type harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers and knob etc., complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets, complete all as specified and directed.
M&L for powder coated Gl frame work for false ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as directed and specified.
M&L for 4 mm thick non asbestos e-boards as in false ceiling with exposed face printed with pattern to match existing ceiling boards and painted / white laminated, fixed to GI snap grid frame work as in ceiling, complete all as specified and directed.
Supply and fixing of factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid single side PVC Laminate with PVC foil of minimum 14 Microns thick of approved colour shade Board comprising of virgin polymer of K value 58-60 (suspension grade) calcium carbonate & Natural Fibers (wood power / rice husk /wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant , including PVC Beading on exposed surface all as per the direction of Engineer-In- Charge. Note : Material test certificate & authentication should be provided by the manufacturing company.
S&F in repair stainless steel kitchen plate rack of size not less than 25.4 cm depth x 91.4 cm width x 91.4 cm height including fixing bracket, complete all as specified and as directed.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick or concrete surfaces (in sunken portion) mixing WPC @ 3% by wt of cement and finished even & smooth without using extra cement, complete all as specified and as directed. Note:- WPC shall be measured and paid separately.
M&L for brushing neat cement slurry @ 3 Kgs/Sqm on any surface, complete all as specified and directed.
M&L for Polythene film, 200 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sqm, complete all as specified and directed.
M&L for PCC (1:5:10) type E2 (using 40mm graded aggregate) as in filling and mass concrete in sunken portion, complete all as specified and as directed.
S&F in repairs sinks with drainage board made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x 100 mm mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed Stainless steel screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/Stainless steel dash 100mm/125mm long fasteners of required dia complete as per direction of Engineer-in-Charge. Note : Material test certificate & authentication should be provided by the manufacturing company.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work,complete all as specified and directed.
M&L for RCC M-25 (Design mix) using 20mm garded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
M&L for RCC M-25 (Design mix) using 20mm garded stone aggregate as in slabs supported chajja and the like complete including all necessary arrangements, complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished, complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
M&L for TMT bars 6-8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil, complete all as specified and directed.
M&L for Hardcore broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all specified and directed.
M&L for 100mm thick plain cement concrete (1:4:8), type D2, using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for Sand filling under floors as in cushioning to receive interlocking tiles complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block, coloured any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
Removing excavated loose soil exc. 250 m but n exc. 500 m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
E/M Portion Taking down carefully existing point wiring any type (light / fan / socket or power point etc.) complete, with all fittings such as switches, socket, regulator, ceiling rose, utility light fittings and lamp holders etc. and removing materials from site and making good the disturbed surfaces of walls roof and floor etc. as per existing specification, complete all as specified and as directed.
Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and fan regulators etc. for reuse at site, complete all as specified and as directed. Note:- To be measured only when found serviceable in all respects complete for reuse.
Supply and fixing Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sqmm, Single Core, PVC Insulated, unsheathed, multistranded copper conductor cable, confirming to IS - 694 drawn through and including medium grade PVC Conduit, minimum 20 mm dia. including all accessories concealed in walls / Floors / false ceiling and open conduit on existing concrete roof etc. and pressed GI modular box of 2.0 mm thick and suitable size as required at site and suitable for modular brackets for fixing modular switches, fittings, etc concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, single core, PVC Insulated, unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light Point controlled by One modular switch testing on completion complete including making good disturbed surface, complete all as specified and as directed.
All as per Srl Item No. 124.00 here-in-before but for one light point controlled by two 2 way modular switch, complete all as specified and as directed.
All as per Srl Item No. 124.00 here-in-before but for one Ceiling fan/Exhaust fan point controlled by 1 one way modular switch and modular regulator, complete all as specified and as directed.
All as per Srl Item No. 124.00 above but for one 3/5 pin modular switch socket outlet, 5 Amp on independent board, complete all as specified and as directed.
All as per Srl Item No. 124.00 here-in-before but for one 3/5 pin modular switch socket outlet, 5 Amp on same board with other switches, complete all as specified and as directed
All as per Srl Item No. 124.00 here-in-before but for one bell point controled by one modular bell push on the same board with other switches or independent board, complete all as specified and as directed.
Supply & fixing Point Wiring complete with 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in walls / Floors / false ceiling and open conduit on existing concrete roof etc.. and pressed GI modular box of 2.0 mm thick and suitable size as required at site and suitable for modular brackets for fixing switches sockets, etc concealed in walls, including 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One 3/5 pin 15 Amp socket outlet point controlled by one modular switch of 15/16 Amp as directed on independent board, complete all as specified and as directed.
Supply and fixing modular switch flush type, single pole one way 6 Amps 230 volts, complete all as specified and as directed.
Supply and fixing switch modular flush type, single pole Two way 6 Amps 230 volts, complete all as specified and as directed.
Supply and fixing modular switch flush type, single pole one way 16 Amps 230 volts, complete all as specified and as directed.
Supply and fixing modular socket 6 Amps 3/5 pin combined 2 Module, complete all as specified and as directed.
Fixing only modular switch socket 6 amp 3/5 pin combined 2 module (Material obtained from item No 123.00 here in before), complete all as specified and as directed.
Supply and fixing modular socket 6/16 amps 3/5 pin combined 2 module shuttered, complete all as specified and as directed.
Supply and fixing modular fan speed regulator 5 step,120 Watt, 2 module, complete all as specified and as directed.
Supply and fixing ceiling rose surface bakelite three terminals, complete all as specified and as directed.
Fixing only ceiling rose surface bakelite three terminals(Material obtained from item No 123.00 here in before), complete all as specified and as directed.
Material and labour for Call bell ding dong AC 230 volt single pole, complete all as specified and as directed
Supply and fixing modular bell push, flush type 6 amps, 1 moudule, complete all as specified and as directed.
Supply and fixing TV co-axial socket 1 module, complete with all acessories, complete all as specified and as directed.
Supply and fixing modular cover inner/outer plates white colour with frame suitable for flush metal boxes for mounting modular switches or sockets etc for 8 modules, complete all as specified and as directed.
Supply and fixing modular cover inner/outer plates white colour with frame suitable for flush metal boxes for mounting modular switches or sockets etc for 6 modules, complete all as specified and as directed.
Supply and fixing modular cover inner/outer plates white colour with frame suitable for flush metal boxes for mounting modular switches or sockets etc for 3 modules, complete all as specified and as directed.
Supply and fixing modular cover inner/outer plates white colour with frame suitable for flush metal boxes for mounting modular switches or sockets etc for 2 modules, complete all as specified and as directed.
Supply and fixing modular cover inner/outer plates white colour with frame suitable for flush metal boxes for mounting modular switches or sockets etc for 1 modules, complete all as specified and as directed.
Material and labour for providing sub-main wiring with 1.5 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 1.5 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC concealed conduit of suitable size including cutting chases pinning in making good to facing and pointing in using cement mortar (1:3) to the ends including taking down old unserviceable sub main wiring and making good disturbed surface complete all as specified and as directed. Note :(i) Two run of 1.5 Sqmm and one run of 1.5 Sqmm as a earth wire cable including one run of PVC conduit shall be measured as an one unit.
Material and labour for providing sub-main wiring with 2.5 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 2.5 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC concealed conduit of suitable size including cutting chases pinning in making good to facing and pointing in using cement mortar (1:3) to the ends including taking down old unserviceable sub main wiring and making good disturbed surface complete all as specified and as directed. Note :(i) Two run of 2.5 Sqmm and one run of 2.5 Sqmm as a earth wire cable including one run of PVC conduit shall be measured as an one unit.
Material and labour for providing sub-main wiring with 6.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 6.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC concealed conduit of suitable size including cutting chases pinning in making good to facing and pointing in using cement mortar (1:3) to the ends including taking down old unserviceable sub main wiring and making good disturbed surface complete all as specified and as directed. Note :(i) Two run of 6.0 Sqmm and one run of 6.0 Sqmm as a earth wire cable including one run of PVC conduit shall be measured as an one unit.
M&L for rigid non metalic PVC conduit 20mm size with boxes (junction/terminal) including 2mm dia GI wire inclusive of all tees, bends, elbows, reducers, bell mouth tub end and fixing accessories such as couplers, locknuts, saddles, pipe hooks etc. (TV cables) including cutting chases pinning in making good to facing and pointing in using cement mortar (1:3) to the ends including making good to disturbed surface, complete all as specified and as directed.
Taking down sheet metal enclosure after disconnecting the electrical connection, dismantling for MCCB DBs, MCB DBs, MCBs and take in safe custody for reuse and re-assembling the MCCBs, MCBs complete and refixing the DBs in same position including all electrical connection, complete all as specified and as directed.
Supply and fix concealed MCB distribution box TPN 4 Way, double door, 415V, IP 43 suitable for MCB 4 Pole as incomer and MCB SP/TP as outgoing complete with suitable busbar, neutral link, earth link, complete all as specified and directed. Note:- (i) MCBs shall be measured and paid saperately. (ii) Blank space shall be covered with blank plates and cost for same shall be deemed to be included in the item quoted rate.
Supply and fix concealed MCB distribution box SPN 8 Way, double door, 240V, IP 42 with 200 Amps rated bus bar, neutral link, earth link, complete all as specified and directed. Note:- (i) MCBs shall be measured and paid saperately. (ii) Blank space shall be covered with blank plates and cost for same shall be deemed to be included in the item quoted rate.
Supply and fixing MCB Four Pole (FP) C curve 10kA breaking capacity of 63 amps, 415 Volts in proper position, complete all as specified and as directed.
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position, complete all as specified and as directed.
S&F MCB SPN of capacity up to 40 amps, 240 Volts C Curve with 10kA breaking capacity, complete all as specified and as directed.
Supply and fixing in repair of single pole and neutral enclosure of 20Amps, 240Volt with a two pin and earth plug and socket complete with one Single pole 20 amp MCB, complete all as specified and as directed.
Fixing only LED batten light 10/20 W light fitting, complete all as specified and as directed. Note :- LED batten light 10/20W light fitting obtain form Srl item No. 123.00 above.
Supply and fixing indoor luminare decorative batten for wall/ceiling mounting box type extruded aluminium housing ,PC diffuser, energy efficient saving LED BATTEN LIGHT 10W, 230 V, 50 HZ, slim integrated design easy install including twin twisted copper conductor flexible wire from ceiling rose to connector, complete all as specified and as directed.
Supply and fixing indoor luminare decorative batten for wall/ceiling mounting box type extruded aluminium housing ,PC diffuser, energy efficient saving LED BATTEN LIGHT 20W, 230 V, 50 HZ, slim integrated design easy install including twin twisted copper conductor flexible wire from ceiling rose to connector, complete all as specified and as directed.
Supply and fixing LED mirror light fittings 10 W, 230 V, 50 HZ suitiable for indoor applications, complete all as specified and as directed.
Supply and fixing LED bulk head fittings 10 W, 230 V, 50 HZ suitiable for indoor and outdoor applications, complete all as specified and as directed.
S&F 10 W LED decorative city 3 wall/surface mounting polycarbonate body siitable for retrofit LED Lamp Base B-22 including lamp , complete all as specified and as directed.
Supply and fixing on wall security LED light luminaire fitting 1X35 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1.5 m long bent to shape including bolt, nut, washer,clamp etc., complete all as specified and as directed.
Supply, testing and hanging of energy saving non decorated ceiling fan 230 v single phase ac 1200 mm sweep, bee 5 star rated Bldc without remote type with accessories like holding down rod, hanging client, blades, including writing mes no (as per standard practice) and flexible 3 core copper conductor cable of suitable size for connecting with ceiling rose complete all as specified and directed
M&L for exhaust fan metal body of size 300 mm sweep, single phase, 230 volts AC and connection complete with cutting of a hole on wall of suitable size, including taking out old unserviceable exhaust fan and kept deposit in mes store yard, complete all as specified and as directed.
M&L for exhaust fan PVC body of size 250 mm sweep, single phase, 230 volts AC and connection complete with cutting of a hole on wall of suitable size, complete all as specified and as directed.
Excavation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr in depth, and getting out in soft/loose soil, complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and as directed.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point , complete all as specified and as directed.
Material and labour for sand cushioning for protection of underground XLPE cables consolidated and compacted with clean dry sand, complete all as specified and as directed. Note :- Compacted thickness shall only be measured and paid.
Taking down Old burnt /Unserviceable underground XLPE cable of any size/type LT 1100 V grade after disconnecting of electric connection complete all as specified and directed at site.
Supplying, laying and testing of XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 70 sqmm 3.5 core laid in trench /poles/on wall, complete all as specified and as directed .
Supplying, laying and testing of XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm 4 core laid in trench /poles/on wall, complete all as specified and as directed .
Supplying, laying and testing of XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trench /poles/on wall, complete all as specified and as directed .
Supplying and laying un-reinforced Precast Cement Concrete cable covers, Class LV, Type-1 with peak, size 250mmX150mm X40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface, complete all as specified and as directed.
Drilling of hole horizontaly 80/40 mm dia bellow the road for providing casing pipe of cable protection by using mechanical/ hand drill, complete all as specified and as directed.
Material and labour for galvanized iron tubing 50 mm bore light grade with all fitting for protection of UG cables, laid in trenches/ wall/floor incl necessary clamp, bolt/nut if any all as specified and as directed. Note:- Excavation ,earth work shall be measured and paid separately.
Taking down carefully ceiling fan of any sweep and any make after disconnecting the electrical connection, dismantling the blades, replacement of ball bearing & fan condenser and removing fan including blades for safe custody for reuse and re-assembling the fan complete and refixing the fan in same position including all electrical connection, complete all as specified and as directed. Note :-Cost of ball bearing and condenser shall deemed to be included in quoted rate.
Material and labour for painting of ceiling fans complete of any sweep/make with one coat of first quality synthetic enamel paint of approved tint by spray including preparation of old painted surface and removing all dust, oil mark etc. and filling cavaties with filler materials, and writing serial / MES number as specified (with paint of black colour with each letters/figures in Block of height n.exc2 cm), complete all as specified and as directed.
Supply, fixing and building security light controller load upto 1 KW comprising of 10 amps single pole MCB, 01 for incoming and 01 for bypass twilight switch, sutaible wiring and including AC single phase static electronic KWH energy meter provision for one energy meter of rating 5-30 A , and including sutaible size enclosure in box or similar SMC box with mounting arrangement fixing nut ,bolt, washer and all accessories, complete all as specified and as directed.
M&L for earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4mm dia. GI wire [Earth Lead] and GI pipe 15 mm, light grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI bolts & nuts complete all as per electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including PCC (1:2:4), Type B1, Pit with RCC (1:2:4), Type B1, Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed. Note :- Cost of 4mm dia. GI wire upto 7.5m length shall deemed to be included in quoted rate.
M&L for earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32X6mm GI strip [Earth Lead] and GI pipe 40 mm, Light Grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI bolts & nuts complete all as per electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC (1:2:4), Type B1, Pit with RCC (1:2:4), Type B1, Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed. Note :- Cost of 32X6mm GI strip upto 7.5m length shall deemed to be included in quoted rate.
Taking down geyser of any capacity after disconnecting the electrical connection and take in safe custody for refixing in same position incl all electrical connections after completion of work, complete all as specified & directed.
Note:- Schedule of credit (Sch 'A' Part- II) amount of Rs 6,77,158.25 shall be deducted from the total quoted amount of BOQ.
SRC COMPANY INFRA PRIVATE LIMITED (BID ID -3471287)
M/S R G Construction (BID ID -3471687)
LUMOS INFRA PVT LTD (BID ID -3472084)
M/s PRABIR ENTERPRISE (BID ID -3468493)
ARRYA ENTERPRISES (BID ID -3476845)
M/s T.K. ENTERPRISE (BID ID -3476862)
M/S P R SINGH AND SONS (BID ID -3471638)
Phoenix Infra (BID ID -3477215)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.37 MB
Tendernotice_2.pdf
PDF • 0.31 MB
TENDER.pdf
Tender Documents • 1.52 MB
BOQ_802713.xls
BOQ • 0.51 MB
TD.rar
Additional Documents • 23.01 MB
WD.rar
Additional Documents • 1.11 MB
Tenderdocument.rar
Tender Documents • 1.11 MB
BOQ.xls
BOQ • 0.51 MB
Tenderdocument.pdf
Tender Documents • 1.52 MB
Tenderdocument_2.rar
Tender Documents • 23.01 MB
Corrigendum_13.pdf
PDF • 0.25 MB
Corrigendum_12.pdf
PDF • 0.25 MB
Corrigendum_11.pdf
PDF • 0.25 MB
Corrigendum_10.pdf
PDF • 0.25 MB
Corrigendum_9.pdf
PDF • 0.25 MB
Corrigendum_8.pdf
PDF • 0.25 MB
Corrigendum_7.pdf
PDF • 0.25 MB
Corrigendum_6.pdf
PDF • 0.25 MB
Corrigendum_5.pdf
PDF • 0.25 MB
Corrigendum_4.pdf
PDF • 0.25 MB
Corrigendum_3.pdf
PDF • 0.25 MB
Corrigendum_2.pdf
PDF • 0.25 MB
Corrigendum_1.pdf
PDF • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .