Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.0 LAccepted-AOC 78 PARASI NEAR PRIMARY SCHOOL PARASI RENUSAGAR RENUSAGAR RENUSAGAR SONBHADRA UTTAR PRADESH 231218 | SONBHADRA | UTTAR PRADESH | 231218 | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹14.4 L+₹88,808 (6.59%)Rejected-Finance | L-2 | Rejected-Finance L-2 Bidder | |
| 3 | L-3₹14.4 L+₹95,041 (7.06%)Rejected-Finance | L-3 | Rejected-Finance L-3 Bidder |
Tender Value
₹12.7 L
EMD Value
₹26,000
Closing Date
22 May 2024, 6:00 pmClosed
SE O and MC-2 DTPS Anpara Sonebhadra
Office of SE O and MC-2 DTPS Anpara Sonebhadra
Overhauling/Servicing/Replacement of HP/ LP Valves of Turbine side of Unit No. 7, 2X500 MW, DTPS, Anpara
2024_RVUNL_922571_1
N-ANP/D/OMC2/TMD/6000005272_00
Open Tender
Miscellaneous Works
Fixed-rate
30 days
Anpara Thermal Power Station DTPSAnpara Sonebhadra
As per Tender Documents
2 documents required · 2 mandatory
₹590
Dy.GM(F), construction unit, C.F.A.and B.O,DTPS
₹26,000
19 Sept 2024
20 Apr 2024
25 May 2024
20 Apr 2024
22 May 2024
20 Apr 2024
20 Apr 2024 - 22 May 2024
Amount
Servicing of Isolating Valve, Control Valve & NRVs of Condensate Line, TDBFP Extraction, Extraction-5 and Booster Pump Suction Line; Size: 400 mm, Class: 150 to 300.
Servicing of Isolating Valve, Control Valve & NRVs installed on BFP discharge, Feed Discharge Line, HPH Inlet/ Outlet, HPH 50% Bypass and other similar valve; Size: 350 mm, Class: 2500 Design press.: up to 320 Kg/cm2, temp.> 180 oC.
Servicing of HPH 100% Bypass valve and Feed water inlet to Economiser of Size: 500 mm, Class:2850
Servicing of BFP Recirculation Line Control Valve; Size: 200 mm, Class: 2500 Design press.: up to 320 Kg/cm2, temp.> 180 oC.
Servicing of BFP Recirculation Line Isolating Valve and SCNRV; Size: 200 mm, Class: 2500 Design press.: up to 320 Kg/cm2, temp.> 180 oC.
Servicing of Isolating Valve and Control Valve from Main Steam Line to Auxiliary Steam Header; Size: 200 mm, Class: 2750 SPL Design press.: 188.5 Kg/cm2, temp.: 545 oC.
Servicing of Main Steam Control Valve to Aux Steam Header; Size: 350 mm, Class: 3500 Design press.: 188.5 Kg/cm2, temp.: 545 oC.
Servicing of Isolating, Control Valve and SCNRVs installed on Aux Steam, Extraction Steam to Deaerator, Extraction Steam to TDBFPs, Extraction Steam to LPH-3; Size: 500 mm, Class: 150 to 300 Design press. <40 Kg/cm2, temp.<330 oC.
Servicing of Extraction Steam Valve or NRV to LPH-2; Size: 800 mm, Class: 150, Design Press.: Vacuum, temp.:135 oC.
Servicing of motor operated control valve, motor operated gate/ globe valves, manually operated gate/ globe valves, check valves; Size:300~350 mm, Class: 150 to 300, Design Pr.< 40 Kg/cm2 and temp.:350 oC.
Servicing of HP Bypass spray water control valves, spray isolation valves, NRVs on Turbine side. Size:100-150 mm, Class: 2500, Pr. : 320 Kg/cm2 and temp.:185 oC.
Servicing of HP Bypass Warm up line regulating valves, Isolation valves, NRVs and other similar valve; Size:50 to 80 mm, Class: 3000 special, Pr.: 188.2 Kg/cm2 and temp.:545 oC.
Servicing of turbine MAL drain valves & Angle Drain Valves (MAL-11, MAL-12, MAL-22, MAL-26, MAL-27, MAL-31, MAL-32, MAL-47, MAL-51, MAL-52, MAL-54, MAL-55, MAL-65, MAL-81, MSV-105, MSV-106, HRHV-105, HRHV-106) and othe similar valves.
Servicing of Isolating valve and control valve of Feed Control Station Size:250 mm, Class: 2500, Pr. : 320 Kg/cm2 and temp.:260 oC.
Servicing of Isolating valve, control valve and NRVs of Size:250 mm, Class: 150-600.
Servicing of Isolating valve, control valve and NRVs of Size:150 mm to 200 mm, Class: 1500, Pr. : 54 Kg/cm2 and temp.:360 oC.
Servicing of Isolating valve, control valve and NRVs of Size:150 mm to 200 mm, Class: 150-600.
Servicing of Isolating valve, control valve and NRVs of Size:40 mm to 50 mm, Class: 1500 to 2500.
Servicing of HP Evacuation valve.
Servicing of Hydraulic Operated Vacuum Breaker Valve.
Servicing of Isolating valve, control valve and NRVs of Size: 15 mm to 100 mm, Class: 1500.
Replacement of LP valves of different Floors by cutting of damaged valve & arc welding of new valve. Size: 15~50 mm.
Replacement of HP line drain valves of different Floors by cutting of damaged valve & welding of new valve. Size: 40 mm to 65 mm.
Replacement of HP drain valves of Feed Water/ Main Steam Line/ CRH Line/ HRH Line etc; above size Nb-65 mm up to150 mm.
Replacement of LP Valves of Nb-250 mm, Pressure Rating < 40 Kg/cm2.
High Pressure Argon/ Arc Welding by IBR Welder.
Replacement of butt welded gate / globe valves of LP lines. Size: 80-100 mm.
Repair/ Replacement of LP/HP piping by cutting & welding on per mm ID basis.
Replacement of flange type gate / globe valves of LP lines; Size: 75 -100 mm.
Servicing of Safety valve of HP Heater, Deaerator & FST, HT< Header of Aux. PRDS & TDBFP Inlet Steam line.
Revisioning / Servicing of Butterfly valves; Size: 65 mm to 250 mm.
Revisioning / Servicing of Butterfly valves; Size: 300 mm to 800 mm.
Revisioning / Servicing of TDBFP Exhaust Butterfly valves; Size: 1600 mm.
Revisioning / Servicing of NRV installed on ACW line & ECW line; Size: 300 mm to 500 mm.
Servicing of gear boxes of butterfly valves installed on ACW & ECW System. Valve Size: 65~250 mm.
Servicing of gear boxes of butterfly valves installed on ACW & ECW System. Valve Size: 300 to 600 mm.
Servicing of gear boxes of butterfly valves installed on ACW System. Valve Size: 800 mm.
Inspection/ Minor repairing of ball catch strainer of condenser tube cleaning system installed inside CW return line of size: 2200 mm.
Replacement of Heater Level Control Valves of Pressure Rating < 40 Kg/cm2.
Replacement of LP Valves of size Nb-300 mm, Pressure rating< 40 Kg/cm2.
Servicing of gear boxes of butterfly valves Size: 2200mm
M/S S N ENTERPRISES
M/S BHARAT ENGINEERS AND ERECTORS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .