Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹2,500
EMD Value
₹1.1 L
Closing Date
7 Oct 2024, 2:00 pmClosed
e
PDD Choglamsar
same as above
2024_PDNRE_14219_1
e-NIT No. 64 of ED Leh of 2024-25 dated 21-09-2024
Open Tender
Electrical Works
Turn-key
30 days
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,500
Payable To Executive Engineer EDD Leh
₹1.1 L
16 Oct 2024
21 Sept 2024
8 Oct 2024
21 Sept 2024
7 Oct 2024
23 Sept 2024
Amount
DT ( Supply Part )
Supply of 100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Supply of 11KV GO, AB Switch 3-phase, 3-pole, 200 Asmp, Vertical Type
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply of 185 mm² Cable,1.1kV Grade, PVC XLPE unarmoured FRLS type
Supply of 9 Mtr. Long Pole,ST-410 SP33)
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Supply of GI Channel/Angle/Flat of sizes including clamps
Supply of Galvinized Nuts and Bolts.
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
Supply of Three Phase Treivector meter (Smart Meter)
Supply of Wedge Connectors/PG Clamps
Supply of Danger Plates with Clamps
Supply of GI Barbed Wire for Anti Climbing
Supply of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Supply of Painting of Poles Red Oxide
Supply of Painting of Poles Aluminium Paint
Supply of Painting of Poles Aluminium Paint
Transformer fencing
Installation/Testing/Commissioning (Part)
Supply of 100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Supply of 11KV GO, AB Switch 3-phase, 3-pole, 200 Asmp, Vertical Type
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply of 185 mm² Cable,1.1kV Grade, PVC XLPE unarmoured FRLS type
Supply of 9 Mtr. Long Pole,ST-410 SP33)
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Supply of GI Channel/Angle/Flat of sizes including clamps
Supply of Galvinized Nuts and Bolts.
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
Supply of Three Phase Treivector meter (Smart Meter)
Supply of Wedge Connectors/PG Clamps
Supply of Danger Plates with Clamps
Supply of GI Barbed Wire for Anti Climbing
Supply of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Supply of Painting of Poles Red Oxide
Supply of Painting of Poles Aluminium Paint
Supply of Painting of Poles Aluminium Paint
Transformer fencing
HT line (Supply Part)
Supply of 9 Mtr. Long Pole,ST-410 SP33)
Supply of GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
Supply of 30 mm² ACSR Conductor
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Supply of 33kV Polymeric composite Disc Insulator 36kV, min failing load 70kn, lighting impulse 170kv positive and 180kv Negative, creepage distance 900mm
Supply of Galvinized Nuts and Bolts
Supply of Danger Plates with Clamps
Supply of Anti-Climbing Device with Clamps
Supply of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Supply of Red Oxide
Supply of Aluminium Paint
Supply of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Supply of Link Set
HT line (installation/Testing /Commissioning Part)
Installation/Testing/Commissioning of 9 Mtr. Long Pole,ST-410 SP33)
Installation/Testing/Commissioning of GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
Installation/Testing/Commissioning of 50 mm² ACSR Conductor
Installation/Testing/Commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Installation/Testing/Commissioning of 33kV Polymeric composite Disc Insulator 36kV, min failing load 70kn, lighting impulse 170kv positive and 180kv Negative, creepage distance 900mm
Installation/Testing/Commissioning of Galvinized Nuts and Bolts
Installation/Testing/Commissioning of Danger Plates with Clamps
Installation/Testing/Commissioning of Anti-Climbing Device with Clamps
Installation/Testing/Commissioning of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Installation/Testing/Commissioning of Red Oxide
Installation/Testing/Commissioning of Aluminium Paint
Installation/Testing/Commissioning of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
installation of Link Set
LT 3-phase/1-phase (Supply Part)
Supply of 8 Mtr. Long Pole( ST-410 SP15)
Supply of GI Channel X-arm (75x40x6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8.83kg, 1No Clamp = 0.83Kg=total weight = 8.83kg)
Supply of GI Channel X-arm (75x40x6mm) 2ft along with GI Clamp, 50x8mm, (2ft=8.83kg, 1No Clamp = 0.83Kg=total weight = 4.83kg)
Supply of 30mmsq ACSR Conductor
Supply of 16KN Polymer Shackle Insulator
Supply of Galvinized Nuts and Bolts.
Supply of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Supply of Red Oxide
Supply of Aluminium Paint
Supply of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
LT line (installation/Testing /Commissioning Part)
installation of 8 Mtr. Long Pole( ST-410 SP15)
installation of GI Channel X-arm (75x40x6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8.83kg, 1No Clamp = 0.83Kg=total weight = 8.83kg)
installation of GI Channel X-arm (75x40x6mm) 2ft along with GI Clamp, 50x8mm, (2ft=8.83kg, 1No Clamp = 0.83Kg=total weight = 4.83kg)
installation of 30mmsq ACSR Conductor
installation of 16KN Polymer Shackle Insulator
installation of Galvinized Nuts and Bolts.
installation of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
installation of Red Oxide
installation of Aluminium Paint
installation of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
M/S MASOOD AHMAD GOVT CONTRACTOR (BID ID -136861)
NAMDRUK ELECTRICALS (BID ID -136909)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .