Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 CrAccepted-AOC | ₹1.7 Cr | 1 | Accepted-AOC Agri No 326/25-26/ 23-03-26 |
| 2 | Rejected-Technical | - | - | Rejected-Technical Diaqualified due to hided the information about balance work |
Tender Value
₹2.3 Cr
EMD Value
₹2.3 L
Closing Date
7 Jan 2026, 6:00 pmClosed
EE PWD SIDHI
EE PWD SIDHI
Const. of Red Cross Hospital Building with Water Supply, Sanitary Fitting and Eletrcificaion Work at Jamodi Segran Sidhi, Under Sub Dn Sidhi, Distt. Sidhi PWD S.O.R. Building SOR W.e.f 01-01-24
2025_PWDRB_468822_1
NIT 18 /SIDHI / 2025-26 / 16-12-25
Open Tender
Civil Works - Buildings
365 days
EE PWD SIDHI
Const. of Red Cross Hospital Building with Water Supply, Sanitary Fitting and Eletrcificaion Work at Jamodi Segran Sidhi, Under Sub Dn Sidhi, Distt. Sidhi PWD S.O.R. Building SOR W.e.f 01-01-24
4 documents required · 4 mandatory
₹15,000
₹2.3 L
13 Apr 2026
22 Dec 2025
9 Jan 2026
22 Dec 2025
7 Jan 2026
22 Dec 2025
Clearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.1 M-15 - Grade concrete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate)
Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.1 M 20 —Grade Concrete
Reinforced cement concrete work (with 20mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and up to floor two level excluding cost of centering, shuttering, finishing and reinforcement : 5.2.1 M 20 —Grade Concrete
Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in beams, suspended floors, roofs havingslope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstaircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement inconcrete grade. 5.3.1 M-20 Grade Concrete
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3.Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) 5.16.3 Cold twisted bars (CTD)
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of columns, etc. for concrete up to plinth level.
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. 5.9.2.1 Uptoplinthlevel.
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts.
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.5 Lintels, beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.3 Suspended floors, roofs, landings, balconies and access platform .
Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. 2.27.1 With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm)
Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm.
Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and stacking of good earth specific useful for plantation at site including royalty if any and carriage (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking of good earth specific useful for plantation at site including royalty if any and carriage (earth measured in stacks will be reduced by 20% for payment).
Providing for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 5.24.1 Preparation of grooves
Providing and fixing mesh in verticaland horizontal junction of RCC and brick/AAC work including scaffolding and all lead and lift etc. complete 13.27.1 G.I. chicken mesh as per ISI specification and in the required width with 50mm long Bombay nails before plastering upt 10 meter height
Preconstruction antitermite treatment to the building under construction by providing. Stage 1: Treating the bottom and the sides(upto 30 cm height of the excavated trench @ 5 liters per sqm of the surface area. Stage 2: After masonry/RCC work, the backfill in the immediate contact with the foundation structure treatment @ 7.5 liters per sqm. Of the vertical surface of the substructure for each side. Stage 3: surface treatment by spreading emulsion over the plinth area before laying the base concrete under floors @ 5.0 litres/Sqm Stage 4: Pumping the emulsion in plinth masonry on filling side at floor junction @ 7.5 litres/Sqm Stage 5: Pumping the emulsion from outer side of the plinth below ground around the masonry @ 5.0 litres/Sqm as per I.S. 8944 Emulsion. (1Chlorpyrifos: 19 water) with five years service guarantee (Measurements to be taken for plinth area) Note – Treatment should start when foundation trenches and pits are ready to take bed concrete or leveling course in foundations. Lying of bed concrete should start when the chemical emulsion has been absorbed by the soil and the surface is reasonably dry. Treatment should not be carried out when it is raining or when soil is wet with rain or subsoil water. This also applies to fill up soil within the plinth area before laying he subgrade for flooring.
Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor II level in 6.7.3 having 50 kg / cm2 average compressive strength 6.7.3.2 Cement mortar 1:6 (1 cement : 6 sand)
Half brick masonry with fly ash lime Gypsum bricks (FALG bricks) conforming to IS: 12894, in super structure above plinth and upto floor two level. 6.15.2 Having 75 kg/cm2 average compressive strength. 6.15.2.1 Cement mortar 1 : 3 (1 cement : 3 sand)
Providing and laying gang saw cut 18 mm thick, mirror polished premoulded (wherever required) and pre polished machine cut granite stonework in flooring of required size shape of approved shade, color and texture in flooring laid over 20 mm thick base of cement mortar 1:4 (1 Cement: 4 sand) including grouting the joints with white cement mixed with matching pigments epoxy touch ups etc. complete as per direction of Engineer-inCharge. 11.30.2 Area of slab upto 0.50 sqm 11.30.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter
Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC rofile), appropriate dimension of UPVC extruded glazing beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profileof frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between rame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be ccepted but no extra payment on this account shall be made. 9.197.1 Two track two panels sliding window made of frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.43.1 Fixed to steel windows by welding
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side having 12 mm air gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications,drawings and direction of Engineer-inCharge complete.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangementand making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-Charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/ ceosetory windows and other frames/chowkhat comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers woodpowder/ rice .husk/wheat husk) and non toxic additives (maximum toxicity indexof 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed S.S. screws having minimum density of 750 kg/m3 and screw withdrawal strength of 2200 N (Face) & 900 N (Edge), minimum ompressive strength 58 N/mm2 , modulus of elasticity 900 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be paid separately) 9.169.3 Single or double rebate (125 mm X 65 mm)
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutter. 9.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice .husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 9.170.1 24 mm thick WPC (Wood polymer composite) solid plain flush door shutter
Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws: 9.123.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.123.4.1 Second class teak wood.
12 mm cement plaster of mix : 13.1.2 1:6 (1 cement : 6 sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.2 1:6 (1 cement : 6 sand)
12 mm cement plaster of mix : 13.1.1 1:4 (1 cement : 4 sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
12 mm cement plaster finished with a floating coat of neat cement of mix : 13.4.1 1:3 (1 cement : 3 sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 sand)
Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound) content less than 50 grams/ltr of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coat on new work.
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. up to floor two level, excluding the cost of centering, shuttering and finishing : 4.2.1.3 M 15 — Grade concrete
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1 st quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11.80.2 In dark colour and shade etc. 11.80.2.3 (c) Size 600X600 mm thickness 11-12mm (to be used in heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.)
Providing and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours & shades, 1st quality/ premium quality in skirting, riser, dado and wall lining laid on 12mm thick ement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 81.2 In dark colour and shades etc. 11. 81.2.2 (b) Size 600X600mm thickness 9-10mm
Providing and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours& shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand)preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.05% and conforming to IS: 15622 of approved make in all colours and shades for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and fixing 10mm thick acid and/ or alkali resistant tiles of approved make and colour using acid and/ or alkali resisting mortar bedding and joints filled with acid and/ or alkali resisting cement as per IS : 4457 complete as per the direction of Engineer-in- Charge. 11.60.1 In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement: 4 sand)Acid and alkali resistant tile.
Providing and laying factory made machine pressed precast cement concrete interlocking paver block of any shape and size conforming to IS:15658- 2006 and ISI marked of 60 mm thickness, M-30 grade with grey cement and pigment all as specified. Made by block making machine with strong vibratory compaction, laid in required colour andpattern over and including 50mm thick compacted bed of stone dust, filling the jointswith sand etc. all complete as per thedirection of Engineer-inCharge.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
Water Supply & Sanitary fitting Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, uPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
Providing and fixing white vitreous china pedestal type Anti germ Fluoro-Polymer Coated Water Closet with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propeline) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.2.1 Anti-germ Fluoro-Polymer Coated (nano coating) European W. C. pan Size 360X545X395 with solid poly propelyne made soft closing seat cover (Premium Range)
Providing and fixing white vitreous china type Anti germ Fluoro-Polymer Coated Wash Basin with C.I. Brackets, 15 mm C. P. wall mounted pressmatic pillar cock auto closing system (decol technology), 15mm quarter turn angular stop ock, 32 mm C.P. brass made waste coupling length 130mm and 32 mm C.P. Brass Made Bottle Trap size 200x300mm fittings and fixtures complete including Painting of fittings and cutting and making good the wall and floors wherever required. 25.7.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595X435X185 mm with basin mounted pressmatic pillar cock auto closing system (decol echnology). (Premium Range)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 17.11.7 White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required : 17.7.4 Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern.
Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish wherever required etc. complete at all levels. samples approved by Engineer-in-charge. 11.22.2 Granite of any colour and shade
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.6.4 Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 17.11.9 White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI marked.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.64.2 Flexible pipe 17.64.2.1 32 mm dia
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 19.9.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.9.1.1 With well burnt bricks
Providing and fixing uplasticised PVC connection pipe with brass unions : 18.17.2 45 cm length 18.17.2.1 15 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 17.57.2 100 mm inlet and 75 mm outlet 17.57.2.1 Sand cast iron S & S as per IS - 3989
Providing and fixing PTMT grating of approved quality and colour. 18.48.1 Circular type. 18.48.1.1 100 mm nominal dia.
Boring/drilling bore well of required dia perfectly vertical to receive casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. 16.1.2 Rocky strata including Boulders. 16.1.2.2 150 mm dia.
Boring/drilling bore well of required dia perfectly vertical to receive casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer –in-charge, beyond 90 metre depth below ground level. 16.1.4 Rocky strata including Boulders. Beyond 90 metre depth. 16.1.4.2 150 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 16.3.2 150 mm nominal size dia.
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 12.32.1 75 mm diameter (minimum wall thickness 1.8mm)
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 12.32.2 110 mm diameter (minimum wall thickness 2.2mm)
Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 17.59.1 Coupler 17.59.1.2 110 mm
Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 17.59.3 Single tee with door 17.59.3.2 110x110x110 mm
Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 17.59.5 Bend 87.50 17.59.5.2 110 mm bend
Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) up to haunches of PVC. Pipes including bed concrete as per standard design : 19.6.1 110 mm diameter PVC. Pipe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineerin-Charge. 18.6.1.3 25 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineerin-Charge. 18.6.1.2 20 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineerin-Charge. 18.6.1.1 15 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plainand brass threaded fittings. This included jointing of pipes and fittings with onestep CPVC solvent cement, trenching, refilling andtesting of joints complete as per direction of Engineer-in- Charge. External Work 18.7.2 20 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plainand brass threaded fittings. This included jointing of pipes and fittings with onestep CPVC solvent cement, trenching, refilling andtesting of joints complete as per direction of Engineer-in- Charge. External Work 18.7.3 25 mm nominal outer dia .Pipes.
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 18.15.1 25 mm nominal bore 18.15.1.1.1 Horizontal
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.14.2 20 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.14.3 25 mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931and weighing not less than 400gm, 15 mm nominal bore
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.27.3 25 mm nominal bore.
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10cm of Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. 12.28.1 100 mm diameter
Providing and fixing CP jet assembly to including connection etc complete.
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.30.1 With well burnt bricks
Constructing brick masonry road gully chamber 45x45x77.5cm with bricks in cement mortar 1:4 (1 cement : 4 sand) with precast R.C.C. vertical grating complete as per standard design : 19.28.1 With well burnt bricks
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 ement :4 sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, oundation concrete 1:5:10 ( 1 cement :5 sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :- 18.18.1 With common burnt clay bricks of 25 kg /sqcm compressive strength.
Electrification Work Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with1.5sq.mm. PVC insulated cable FRL Swith copper multistrand conductor ISI marked in concealed rigid P.V.C.conduit (HMS) ISI marked of suitable size and1.5sq.mm. PVC insulated FRL Scoppere arth continuity conductor of green colour inside conduit, screw less connector for joints etc. as required as per specification for 4.1.1 Light point/fan points. 4.1.1.1 Primary short point
Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with1.5sq.mm. PVC insulated cable FRL Swith copper multistrand conductor ISI marked in concealed rigid P.V.C.conduit (HMS) ISI marked of suitable size and1.5sq.mm. PVC insulated FRL Scoppere arth continuity conductor of green colour inside conduit, screw less connector for joints etc. as required as per specification for 4.1.1 Light point/fan points. 4.1.1.2 Primary medium point
Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with1.5sq.mm. PVC insulated cable FRL Swith copper multistrand conductor ISI marked in concealed rigid P.V.C.conduit (HMS) ISI marked of suitable size and1.5sq.mm. PVC insulated FRL Scoppere arth continuity conductor of green colour inside conduit, screw less connector for joints etc. as required as per specification for 4.1.1 Light point/fan points. 4.1.1.3 Primary Long point
Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with1.5sq.mm. PVC insulated cable FRL Swith copper multistrand conductor ISI marked in concealed rigid P.V.C.conduit (HMS) ISI marked of suitable size and1.5sq.mm. PVC insulated FRL Scoppere arth continuity conductor of green colour inside conduit, screw less connector for joints etc. as required as per specification for 4.1.3 3 Pin 6 Amp socket outlet on separate board 4.1.3.2 Medium Point
Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with1.5sq.mm. PVC insulated cable FRL Swith copper multistrand conductor ISI marked in concealed rigid P.V.C.conduit (HMS) ISI marked of suitable size and1.5sq.mm. PVC insulated FRL Scoppere arth continuity conductor of green colour inside conduit, screw less connector for joints etc. as required as per specification for 4.1.3 3 Pin 6 Amp socket outlet on separate board 4.1.3.3 Long Point
Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with1.5sq.mm. PVC insulated cable FRL Swith copper multistrand conductor ISI marked in concealed rigid P.V.C.conduit (HMS) ISI marked of suitable size and1.5sq.mm. PVC insulated FRL Scoppere arth continuity conductor of green colour inside conduit, screw less connector for joints etc. as required as per specification for 4.1.4 Call bell/buzzer points 4.1.4.2 Medium Point
Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with1.5sq.mm. PVC insulated cable FRL Swith copper multistrand conductor ISI marked in concealed rigid P.V.C.conduit (HMS) ISI marked of suitable size and1.5sq.mm. PVC insulated FRL Scoppere arth continuity conductor of green colour inside conduit, screw less connector for joints etc. as required as per specification for 4.1.4 Call bell/buzzer points 4.1.4.3 Long Point
Point wiring (excludin gmetallic switch box & sheet but including switches, sockets) for3pin6Amp. socket outlet point with1.5sq.mm. PVC insulated cable FRL Swith copper multistrand conductor ISI marked in concealed rigid P.V.C.conduit (HMS) ISI marked of suitable size and1.5sq.mm.PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board.
Wiring for circuit wiring with PVC insulated cable FRL Swith copper multistrand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification 4.3.1 2x2.5 Sq.mm.
Wiring for circuit wiring with PVC insulated cable FRL Swith copper multistrand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification 4.3.2 4x2.5 Sq.mm.
Wiring for circuit wiring with PVC insulated cable FRL Swith copper multistrand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification 4.3.3 6x2.5 Sq.mm.
Wiring for circuit wiring with PVC insulated cable FRL Swith copper multistrand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification 4.3.4 8x2.5 Sq.mm.
Point wiring (excluding metallic switch box & sheet) for 3Pin16Amp. socket outlet point with 4sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with20/16Amp. F.T. switch & socket/S.S. combined20/16/6Amp. of ISI marked and 4sq.mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screw less connector for joints as per specification for :- 9.1.1 On separate board 9.1.1.2 Medium
Point wiring (excluding metallic switch box & sheet) for 3Pin16Amp. socket outlet point with 4sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with20/16Amp. F.T. switch & socket/S.S. combined20/16/6Amp. of ISI marked and 4sq.mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screw less connector for joints as per specification for :- 9.1.1 On separate board 9.1.1.3 Long
Point wiring (excluding metallic switch box & sheet) for 3Pin16Amp. socket outlet point with 4sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with20/16Amp. F.T. switch & socket/S.S. combined20/16/6Amp. of ISI marked and 4sq.mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screw less connector for joints as per specification for :- 9.1.1 On separate board 9.1.1.4 Extra Long-I
Point wiring (excluding metallic switch box & sheet) for 3Pin16Amp. socket outlet point with 4sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with20/16Amp. F.T. switch & socket/S.S. combined20/16/6Amp. of ISI marked and 4sq.mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screw less connector for joints as per specification for :- 9.1.1 On separate board 9.1.1.5 Extra Long-II
Point wiring (excluding metallic switch box & sheet) for 3Pin16Amp. socket outlet point with 4sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with20/16Amp. F.T. switch & socket/S.S. combined20/16/6Amp. of ISI marked and 4sq.mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screw less connector for joints as per specification for :- 9.1.1 On separate board 9.1.1.6 Extra Long-III
Supplying and fixing of approved make modular type G.I. metal box1.2 mm minimum thick and depth50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 18.2.1 G.I box 1 Or 2 module
Supplying and fixing of approved make modular type G.I. metal box1.2 mm minimum thick and depth50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 18.2.4 6 Module metal box
Supplying and fixing of approved make modular type G.I. metal box1.2 mm minimum thick and depth50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 18.2.5 8/9 Module metal box
Supplying and fixing of approved make modular type G.I. metal box1.2 mm minimum thick and depth50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 18.2.6 12 Module metal box
Supplying and fixing of approved make modular type G.I. metal box1.2 mm minimum thick and depth50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 18.2.7 16 Module metal box
Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping /conduit in surface or concealed as per specification. 19.1.1 1.5 sq. mm. wire 19.1.1.1 1 X 1.5 sq. mm.
Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping /conduit in surface or concealed as per specification. 19.1.1 1.5 sq. mm. wire 19.1.1.3 3 X 1.5 sq. mm.
Wiring for sub-main swith PVC insulated cable FRL Swith copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) ISI marked of suitable size(conduitincluded) including 2mm thick accessories, connection etc, as required as per specification.(Refer General Notes for Classification of Conduit Wiring Point No.10) 23.1.4 4 Wire sub main 23.1.4.3 6.0 sq. mm. cable
Wiring for sub-main swith PVC insulated cable FRL Swith copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) ISI marked of suitable size(conduitincluded) including 2mm thick accessories, connection etc, as required as per specification.(Refer General Notes for Classification of Conduit Wiring Point No.10) 23.1.4 4 Wire sub main 23.1.4.4 10.0 sq. mm. cable
Wiring for sub-main swith PVC insulated cable FRL Swith copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) ISI marked of suitable size(conduitincluded) including 2mm thick accessories, connection etc, as required as per specification.(Refer General Notes for Classification of Conduit Wiring Point No.10) 23.1.4 4 Wire sub main 23.1.4.5 16.0 sq. mm. cable
Supply of I.S.I. marked iron clad/metal clad triple pole and neutral switch fuse (conduit entry)/cable gland entry with two earthing terminals 25.2.3 63 Amps. 415/500 Volts.
Supply of I.S.I. marked iron clad/metal clad triple pole and neutral switch fuse (conduit entry)/cable gland entry with two earthing terminals 25.2.4 100 Amps. 415/500 Volts.
Supply of I.S.I. marked iron clad/metal clad triple pole and neutral switch fuse (conduit entry)/cable gland entry with two earthing terminals 25.2.5 200 Amps. 415/500 Volts.
Supplying of ISI Marked Change over switches in sheet enclosure confirming to IS : 4064 / IS : 13947 (part I & III ) with side handle operated 4 pole with two earthing terminals 25.4.5 200 Amps. 415/500 Volts. (off load )
Supply & fixing of I.S.I.marked Porecelain Rewireable fuse unit of approved make or confirming to I.S.S. 2086-1982 25.16.4 63 Amps /415 Volts
Supply & fixing of I.S.I.marked Porecelain Rewireable fuse unit of approved make or confirming to I.S.S. 2086-1982 25.16.5 100A/415 Volts
Supply & fixing of I.S.I.marked Porecelain Rewireable fuse unit of approved make or confirming to I.S.S. 2086-1982 25.16.6 200 Amps /415 Volts
SupplyingofmetalcladISImarkedbusbarchambermadeofheavygaugeironsheetcompletewithcopperstripandbusbarsupportsasperspecificationconforming to IS -4064 26.1.2 60/63 Amp 415 VOLTS, 4 way
SupplyingofmetalcladISImarkedbusbarchambermadeofheavygaugeironsheetcompletewithcopperstripandbusbarsupportsasperspecificationconforming to IS -4064 26.1.3 100 Amp 415 VOLTS, 4 way
SupplyingofmetalcladISImarkedbusbarchambermadeofheavygaugeironsheetcompletewithcopperstripandbusbarsupportsasperspecificationconforming to IS -4064 26.1.4 200 Amp 415 VOLTS, 4 way
Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures 27.8.1 Single pole 27.8.1.2 MCB SP 6Amp to 32Amp 10kA rating
Supplying of MCB Isolators suitable for 240/415 Volts, 50 Hz AC supply with kA value rating 10 kA of approved make conforming to IS:13947-Part III :1993 & IEC:60947- 3:2001 (without enclosures ) :- 27.10.2 Double pole 27.10.2.1 Current rating upto 40Amp
Supplying of MCB Isolators suitable for 240/415 Volts, 50 Hz AC supply with kA value rating 10 kA of approved make conforming to IS:13947-Part III :1993 & IEC:60947- 3:2001 (without enclosures ) :- 27.10.2 Double pole 27.10.2.2 Current rating upto 60Amp
Supplying of MCB Isolators suitable for 240/415 Volts, 50 Hz AC supply with kA value rating 10 kA of approved make conforming to IS:13947-Part III :1993 & IEC:60947- 3:2001 (without enclosures ) :- 27.10.4 Four pole 27.10.4.4 Current rating upto 100Amp
Supply of approved make powder coated sheet steel encloser SPNMCBDB inclusive of bus bar, neutral bar, earth bar, connection copper wire not less than 16sq. Mm & two earth terminals etc. complete as perIS:13032 (exclusiveof MCB & isolator)- 27.11.4 6 Way double door IP 43 protection
Supplying of approved make TPN MCB DB metal double door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator): 27.12.1 4 Way (4+12)
Supplying of approved make TPN MCB DB metal double door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator): 27.12.3 6 Way (8+18)
Supplying & fixing of ISI marked Industrial type metal plug socket D.B.s (without MCBs) for TPN encloser three pole and earth metal plug and socket including space to incorporate TP MCB complete as per specification as required. 27.19.1 20 Amp
Fixing of metal clad enclosure on 25X 25 X 5 mm angle iron clamp including supplying and fixing of clamp as required duly embedded in masonry including cable connection and other required material as per specification :- 28.2.1 Fixing of 63Amp TP or TPN main switch or 63Amp change over switch/63 Amp 415Volt Isolators and bus bar 4 way
Fixing of metal clad enclosure on 25X 25 X 5 mm angle iron clamp including supplying and fixing of clamp as required duly embedded in masonry including cable connection and other required material as per specification :- 28.2.2 Fixing of 100Amp TP or TPN main switch or 100Amp change over switch/100 Amp 415Volt Isolators and bus bar 4 way
Fixing of metal clad enclosure on 25X 25 X 5 mm angle iron clamp including supplying and fixing of clamp as required duly embedded in masonry including cable connection and other required material as per specification :- 28.2.3 Fixing of 200Amp TP or TPN main switch or 200Amp change over switch/200 Amp 415Volt Isolators and bus bar 4 way
Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only) 28.4.1 MCB/Isolator SP/DP
Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only) 28.4.2 MCB/MCCB Isolator TP/TPN/FP
Supply and fixing in position LED lamp of approved make 29.7.3 5 Watt250Volt
Supply and fixing in position LED lamp of approved make 29.7.6 12 Watt250Volt
Supply and fixing of approved make step type modular electronic fan regulator including connection etc. asrequired on existing board 29.25.2 100 Watt (2 module)
Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. 29.28.3 Frequency Metre
Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. 29.28.5 Copper bus bar strips with PVC sleeves
Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. 29.28.6Aluminium bus bar strips with PVC sleeves
Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. 29.28.7 LED lamp indicator
Supplying, erection and testing of approve make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments. 30.1.2 Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value ≥ 4.00 as per BEE..
Supplying, erection and testing of approved make wall mounting fan oscillating type with base, blades, guard, speed regulator etc. AC230-250 volts with connections and including raw bolt/anchor hole fastener etc. complete finished and as required. 30.2.1 300 mm sweep
Supplying, erection and testing of approved make cabin fan oscillating type with base, blades, guard, speed regulator etc.AC230-250 volts with connection sand including raw bolt/anchor hole fastener etc. complete finished and as required. 30.3.1 300 mm sweep
Supplying, erection and testing of approved make' Freshairfan'AC230-250volts with connection and including frame bolt/anchor hole fasteners etc. complete finished and as required. 30.4.3 300 mm sweep bush type
Supply and fixing Led tube rod comprising of LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 31.3.4 Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser.
Supply and fixing recessed mounting LED down lighter, LED of 1to3Watt each assembled on single MCPCB, having color temp up to 6500K & having 50000 burning hrs. life with minimum@L70, system lumen output should be minimum with efficacy>100lm / Watt. LED driver PF>0.95,THD<20%& surge protection 4KV. The colour rendering index of LED light should be more than70. Housing made of pressure die cast aluminium/ CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08 / IS 16106 (2012), IEC 60598, IEC 61347 i/c connection wire, testing etc. to complete the job.. 31.618/20Watt, color temp 3000-6500k as required.
Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. 31.13.140Watt to 48Watt, color temp 3000-6500k as required.
Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. 31.13.2 60 Watt, color temp 3000-6500k as required.
Earthing with G.I. earth plate 600mm X 600mm X 6mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without charcoal or coke and salt) complete as required
Add extra for using salt and charcoal /coke for G.I. plate or copper plate earth electrode as required including excavation and refilling the pit in all type of soil, murrum
Supply and laying 25mm X 5mm G.I. strip at 0.5 metre below ground level as strip earth electrode including jointing etc. as required.
Supply of XLPE insulated power cable (conforming IS-7098 Part-I)1100Volt grade,1core/2core/3½core/4coreISImarked with alu. stranded /solid conductor 41.1.10 4 core armoured 41.1.10.5 35 sq. mm
Supply of XLPE insulated power cable (conforming IS-7098 Part-I)1100Volt grade,1core/2core/3½core/4coreISImarked with alu. stranded /solid conductor 41.1.10 4 core armoured 41.1.10.6 50 sq. mm
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_552872.pdf
techsummary_552872.pdf
finance_552872.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.08 MB
468822Doc.pdf
Tender Documents • 18.21 MB
BOQ_552872.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid