Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC TERMS AND CONDITIONS ACCEPTED | |
| 2 | L2₹19.4 L+₹4.9 L (34.3%)Rejected-Finance | L2 | Rejected-Finance Rejected being not the lowest | |
| 3 | L3₹20.8 L+₹6.4 L (44.3%)Rejected-Finance NO 3 JANI JAN KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L3 | Rejected-Finance Rejected being not the lowest | |
| 4 | L4₹22.4 L+₹8.0 L (55.7%)Rejected-Finance NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L4 | Rejected-Finance Rejected being not the lowest |
Tender Value
₹18.8 L
EMD Value
₹37,200
Closing Date
24 Apr 2021, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I)(CG) Military Engineer services Second Floor CG DHQ No 5(TN) No 4 and 4 A Clive Battery complex Rajaji Salai Chennai 600001
Special repairs to conversion of convention lights into LED lights at CG Family Accommodation Royapuram and special repairs to replacement of BER motor/pumps and cooling appliances at RHQ(E) CGRA Royapuram and Provision of LED Name Board for BMU(CHN)
2021_MES_423946_2
8838/GE(I)CG
Open Tender
Civil Works
Item Rate
90 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹37,200
Yes
18 Jun 2021
8 Apr 2021
26 Apr 2021
8 Apr 2021
24 Apr 2021
10 Apr 2021
Amount
Taking down carefully by unscrewing from boards /outlet boxes ,fittings and fixtures such as lamp holdres ,brackets , ceiling fittings , bulk head fittings , tube light fittings of any size and recessed mounted fittings etc and removing the item from site and taken as credit and making good the disturbed surfaces/false ceiling complete all as specified and as directed.
Supply and Fix wall/surface mounted LED batten 20W, 230 V ,luminous efficacy more than 100 lm/W with integrated driver etc with all accessories internally prewired and including connecting up with twincore flexible copper conductor cable with suitable size complete all as specified and as directed. Make : Surya Roshini cat part No SLE BT 20 IL or equivalent in Wipro cat part No D632065 20W-6500K
Supply and Fix wall/surface mounted LED batten 10W, 230 V , luminous efficacy more than 100 lm/W with integrated driver etc with all accessories internally prewired and including connecting up with twincore flexible copper conductor cable with suitable size complete all as specified and as directed. Make : Surya Roshini cat part No SLE BT 10 or equivalent in Wipro cat part No D631065 10W-6500K:
Supply and Fix ceiling fan complete with electronic regulator and canopy,down rod ,03 numbers of blades and accessories ,230 V ,1200 mm sweep ,BEE 5 star rated including pre wired with PVC flexible copper cable of required length including taking down old ceiling fan of any size and removal from site and taken as credit complete all as specified and as directed.Note Make of ceiling fan :Orient/Bajaj/Almonard
Supply and Fix wall mounted fan complete with accessories ,230 V ,450 mm sweep ,BEE 5 star ratedincluding pre wired with PVC flexible copper cable of required length including taking down old wall mounted fan of any size and removal from site and taken as credit complete all as specified and as directed.Note Make of wall mounted fan :Orient/Bajaj/Almonard
Supply and Fix pedestal fan complete with accessories ,230 V ,450 mm sweep ,BEE 5 star ratedincluding pre wired with PVC flexible copper cable of required length including taking down old pedestal fan of any size and removal from site and taken as credit complete all as specified and as directed.Note Make of pedestal fan :Orient/Bajaj/Almonard
Supply and Fix exhaust fan complete with accessories ,single phase ,230 V ,300 mm sweep , heavy duty ,BEE 5 star ratedincluding pre wired with PVC flexible copper cable of required length including taking down old exhaust fan of any size and removal from site and taken as credit complete all as specified and as directed.Note Make of exhaust fan :Orient/Bajaj/Almonard
Supply, fix and test water heater storage type (Geyser) of capacity 25 litres capacity, 5 Star rating, 2 KW heating element, ergoniminally styled plastic body. Unique temparature indicator dial, adjustable thermostat, magnesium anode for extra protection from corrison and leakage, glass line inner tank, PUF insulation, product warranty 2 years, Tank warranty 7 years, heating element warranty 3 years rust & shock proof autocut facility complete fixed at location as directed including one non return valve & one safety valve inbuilt of geyser fire retardant ISI mark supply cord with plug top and electrically operated suitable for 230 volts and cold water line 01 No and anchor bolts including taking down old water heater of any size and removal from site and taken as credit complete all as specified and directed. Note : Anchor bolt shall be grouted with hammer drill only. Make of Geyser : Bajaj /Racold/Venus
Supply and fix in repairs Microprocessor based single phase electronic temper proof energy metre of rating 10 to 60 Amps with optical communication port confirming to IS-13779 including taking down old energy metre of any size and removal from site and taken as credit complete all as specified and as directed.Note Make of energy metre :Secure/L&T/EL Measure
Supply, Install, Test & Commisssion Open well Submersible pump set, electric driven 3 Phase, 415 V, 3 Star rating, 3 HP, 2.20 KW discharge 11 LPS at 22 Meter Head. Size of Suction and delivery size: 65mmx50mm dia including FRLS PVC flexible copper conductor of size 4sqmm 3 core for connection of Pump complete all as specified and as directed..Note:. Make : Kriloskar Brother Ltd. Model No: KOSJ-325 3 65x50 3P Cll or Equivalent make of M/S Texmo/M/s KSB
Supply and fix 3 Phase DOL starter suitable for 1HP to 5 HP submersible pump setcomplete all as specified and as directed..Note:. Make :BCH/L&T
Supply and fix LED Signage Board of size 23 feetx 5.5 feet and of letter height not less than 60cm made out of Aludecor or AlutechACP Panel for background Acrylic and GI base channel letters,illuminated using 1.50 watts,12 V DC samsung LED Modules and powdered using 200 Watts driver with 3 D Model colour including electrical connection , MS frame work and fixing arrangement etc.as per manufacturers instruction Note :(i) Fixing arrangements such as screw, nut &Bolt, washers and cement work all are included in the above quoted rates. Note (ii) LED light from Samsung 3 year warranty ,1.5/120lm/IP 68 /CE/RoHs, LED Drive 1 year warranty against Rain proof ,.Male letters 2mm thick imported acrylic, Female letters 3mm Acrylic base with 25mm inner beading,letters projection 50mm from the back ground,internal frame 25x25x1mm GI Pipe, letter box 50mm, Pvc copper cable of size 3 core 2.5 sqmm from switch board to display board with fixing arrangement including on/off switch etc.
Material and labour for Sub main wiring with two runs of single core 2.50sqmm multi stranded copper conductor FRLS PVC insulated unsheathed cable 1100 volts grade and one run of 2.50 sqmm multi stranded PVC FRLS copper conductor cable as earth continuity conductor drawn into and including non-metalic rigid PVC conduit, 25mm dia and conduit accessories/PVC casing capping and concealed/surface of wall/roof/ceiling etc complete all as specified and as directed. Note: (i)Three runs of 2.5 sqmm cable and one run of 25mm dia conduit/casing capping shall be measured as one unit length. (ii)Make of PVC cable : Finolex/ Polycab/Plaza.(iii) Make of PVC Conduit :Avon Plast/Presto Plast/Finolex (iv) Two different colour cable shall be used for phase and neutral.(v) The PVC cable connections with MCBs or Busbar shall be done through appropriate size brass/copper thimbles.
Supply and fix Switch socket combination 2 in 1, 3 pin, 5/15 Amps Flush type 240 Volts complete all as specified and directed.Make: Legrand/Anchor/ABB
Material and labour for Earthing complete with copper earth plate electrode of size 600 mm x 600 mm x 6mm thick buried directly in ground ( earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to copper earth strip of 32mm x 6mm by means of bolts, nuts, check nuts and washers of copper all as shown in electric plate No 3 connecting to earthing test point including necessory excavation in any earth strata, PCC chambers in PCC 1:3:6 type C1, RCC 1:2:4 type B1 cover slab 50mm thick with 8mm dia TMT HCR / CRS steel bars at 140mm C/C both way and lifting handle watering pipe of GI 20 mm dia medium grade, funnels, wire mesh, charcoal and including 25 kgs of bentonite with lifting handle watering pipe of GI medium grade 20mm dia, wire mesh, funnel, lugs and charcoal, salt etc all as applicable and as per Electric Plate No 3 of SSR complete all as specified and as directed.
Material and labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chasses or buried in grouting or drawn in conduit/pipe or foxed to poles or any other indicated situation for loop earthing etc as requried 32*6mm complete all as specified and as directed.
Note: Orginial GST paid PV's/TC for the materials procured for the above BOQ items shall be produced alongwith the payment claimed by the contractor.
NVRAGAVANANDSONS
SRI LAKSHMI ASSOCIATES
PSK Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .