Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC MOHALLA KAMA KHAN WARD NO 07 HOUSE NO 88 DISTT POONCH J K | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹29.6 L+₹1.9 L (6.73%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹30.5 L+₹2.8 L (10.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹34.3 L+₹6.6 L (23.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/S KABIR CHOUDHARY L2 | JAMWAL CONSTRUCTION CO L1 | KRISHNA BUILDERS L3 | SUNIL KUMAR SANGEET KUMAR AND SONS L4 |
|---|---|---|---|---|---|---|---|
| 1.00List of works pertains to Bathroom and Toilet Block with allied infrastructure. | |||||||
| 2.00Schedule 'A' Part-I (Building Work) | |||||||
| 2.01 | Construction of Bathroom&Toilet Block with allied infrastructure work complete all as specified and as shown on drawings. | 1 | Each | 5,00,000 ₹5,00,000 Lowest | 5,73,000 ₹5,73,000 | 5,80,000 ₹5,80,000 | 5,20,000 ₹5,20,000 |
| 3.00Schedule 'A' Part-II (Hot Water Supply Works) | |||||||
| 3.01 | Total amount of Sch 'A' Part-II (Hot Water Supply Works) brought forward from srl page No-26 | 1 | Each | 10,000 ₹10,000 Lowest | 13,000 ₹13,000 | 16,000 ₹16,000 | 15,000 ₹15,000 |
| 4.00Schedule 'A' Part-III (Road and Path Works) | |||||||
| 4.01 | Total amount of Sch 'A' Part-III (Road and Path Works) brought forward from srl page No-27 | 1 | Each | 30,000 ₹30,000 | 22,000 ₹22,000 Lowest | 23,000 ₹23,000 | 33,000 ₹33,000 |
| 5.00Schedule 'A' Part-IV (Electrification Works) | |||||||
| 5.01 | Total amount of Sch 'A' Part-IV (Electrification Works) brought forward from srl page No-28 | 1 | Each | 40,000 ₹40,000 Lowest | 41,000 ₹41,000 | 41,000 ₹41,000 | 44,000 ₹44,000 |
| 6.00Schedule 'A' Part-V (Sewage Disposal Works) | |||||||
Tender Value
₹32.9 L
EMD Value
₹65,720
Closing Date
9 Jan 2026, 6:00 pmClosed
GE 881 EWS
GE 881 EWS, C/O 56 APO
PROVN OF BATHROOM AND TOILET BLOCK WITH ALLIED INFRA FOR IFSU COLLAPSIBLE GATE IN BLDG of GE OFFICE AND SPL REP TO BLDG NO P-92 AND P-69 OF AP-255 UNDER GE 881 EWS
2025_MES_743259_1
GE/PNH-87/2025-26
Open Tender
Civil Works
Lump-sum
180 days
GE 881 EWS, C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE 881 EWS
₹65,720
Yes
13 Apr 2026
5 Dec 2025
12 Jan 2026
5 Dec 2025
9 Jan 2026
3 Jan 2026
Total amount of Sch 'A' Part-VII (Internal Electrification Works) brought forward from srl page No-33
Schedule 'A' Part-I (Building Work)
Construction of Bathroom&Toilet Block with allied infrastructure work complete all as specified and as shown on drawings.
Schedule 'A' Part-II (Hot Water Supply Works)
Pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x25x3mm thick angle iron projecting 10cm on either side & PCC 1:3:6 type C-0 in back filling of chowkats & tarring back of chowkats and holdfasts complete all as specified & directed.
Schedule 'A' Part-III (Road and Path Works)
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armouredwith galvanised steel wire or tape and overall PVC sheathed 16 sq.mm nominal cross section in service connections , complete all as specified and directed.
Schedule 'A' Part-IV (Electrification Works)
Supply and fixing in repairs, Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as spesified and directed .
Schedule 'A' Part-V (Sewage Disposal Works)
Total amount of Sch 'A' Part-II (Hot Water Supply Works) brought forward from srl page No-26
Schedule 'A' Part-VI (Area Drainage Works)
Total amount of Sch 'A' Part-III (Road and Path Works) brought forward from srl page No-27
Chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adehessive on complete exposed surfaces of concrete and provide guniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by weight of cement or as per manufactures instructions and finally applying 10 to 15 mm thick cement plaster over gunite surfaces of required thickness to give an even uniform and smooth finish conforming to proper Geometrics in cement mortar 1:4 to match with the existing surface as in side and soffits of slabs,chajjas,fins,facias ,parapets ,columns and beams etc complete including necessary scaffolding ,shuttering necessary chased to brick work or RCC members at any height of buildings incl removing of small trees shrubs etc all as specified. Note: steel welded mesh to be welded with the existing reinforcement. The cost of welded mesh is to be welded with the existing re-inforcement is deemed to be included in the quoted rate complete all as specified and directed.
Total amount of Sch 'A' Part-IV (Electrification Works) brought forward from srl page No-28
Preparation of newly plastered or unplastered surface of wall and applying two coats of white wash over a coat of primer on wall surfaces to give an even and smooth surface complete all as specified and directed.
Total amount of Sch 'A' Part-V (Sewage Disposal Works) brought forward from srl page No-30
Total amount of Sch 'A' Part-VI (Area Drainage Works) brought forward from srl page No-31
Schedule 'A' Part-VII (Internal Electrification Works)
Supply laying and fixing DWC HDPE pipe for protection of power cable (orange colour) of size 50 mm dia complete with fittings and including cutting, jointing and clamping all as specified and directed.
Schedule 'A' Part-VIII (Plumbing Works)
PVC (SWR) pipes 150mm dia any length single socketed with rubber ring, joint and laid in trenches/floors, complete all as specified and directed.
Schedule 'A' Part-IX (Internal Water Supply)
Schedule 'A' Part-X (Misc Items of Works pertain to work of Office bldg with allied infrastructure ) Note : This schedule is not prepriced by MES and the pre-priced rate indicated as "Rs0.00" under Col.5 signifies this fact only.
Brick masonry valve pit of size 60x60x90 cm (internal dimension of chamber) including plastering internal 15 mm thick in CM 1: 4 and flush pointing external as the work proceeds in same mortar complete with MS sheet cover handle, packing arrangement, earth work in any type of soil incl removal to n.exc 50 mtr and paint with 2 coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces complete all as specified.
Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
Joist,channel angle or tee sections fixed independently without connecting plates etc (cut to ordinary lengths i.e with in 20mm of the length indicated) confirming Fe-290 Gde E-165 complete all as specified and directed.
Preparation of new or previously untreated steel or iron surfaces of any description, not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
On site LLDPE septic tank 10 User designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 in foundation 150 mm thick, vent shaft, connection etc. complete all as specified and directed.
B/R Portion:- M&L for followings :- (i) Removing plaster & finishes from all exposed / damaged portion of coloumns, slabs & beams (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible from all sides) (iii) Removal of cover concrete with under cutting of up to a depth of 10mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-charge may order sand blasting, if needed) (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
Providing rust proof /anti corrosive treatment to bars :- (i) cleaning of all exposed bars (new & old) alround (ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer (iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re-bars (those towards the concrete substrate) should not be left without coating.
15mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane, and water proofing compound @ 3% complete all as specified and as directed. (NOTE : Polymeric membrane & Water proofing compound shall be measured and paid separately ).
Water proofing treatrment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top :- (a) Applying bitumenous primer @ 0.4 ltrs per Sqm over plastered surfaces of roof incl parapet surface. (b) Over the priming coat laying one layer APP based polymembric membrane of approved manufacturer 3mm thick weight not less than 3 Kgs per Sqm reinforced with non woven polyester febric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note :- (i)Laying APP bassed polymenic membrane shall be done torch on methed or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturer's instruction.
Dismantling of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position (reinforement cut as required to facilitate demolition) by using diamond saw blade cutting machine without damaging adjacent RCC structures including removal of rubbish outside compleex (MOD land ), complete all as directed by Engineer-in-Charge.
Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 all as specified and directed
RCC M-25(design mix) using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed
RCC M-25(design mix) using 20mm graded crushed stone aggregate as in roof slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like with fair finished surface complete all as specified and directed.
RCC M-25(design mix) using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span fair finished surface complete all as specified and directed.
TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified.
TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified.
Fixing TMT rebar with existing RCC slab through drilling hole n.exc 15mm dia upto 0.30mm depth horizontally and filled with injecting cement slurry in CM 1:4 and water proofing compound @ 0.20 ltr per 50 kgs complete all as specified and directed.
Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams etc with fair finished surface of concret complete all as specified & directed.
Form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for fair finished surfaces of concrete, complete all as specified and directed.
Form work to sides of pillars, posts, struts piers, columns and stanchions and similar works fair finished surface of concrete complete all as specified & directed by Engineer-in- charge.
5mm thick rendering in cement mortar 1:3 finished even and smooth surface without using extra cement on ceiling, chajja in single storey building etc complete all as specified and directed by Engineer-in-Charge
15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth surface without using extra cement complete all as specified and directed by Engineer-in-Charge
10mm thick rendering in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth surface without using extra cement complete all as specified and directed by Engineer-in-Charge
Applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces in painting on walls complete all as specified and as directed.
Complete removal of existing treatment on walls and Finishing walls with Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) all as specified and directed
(iii) APP bassed polymeric membrane shall be "Dr Fixit" manufacturered by M/S Pidilite Industries or "MOPLY FP 3MM" manufactured by M/S Texsa India Limited and 'Hyperplus" by IWL India Limited (iv) Applying two coats of Aluminium paint over APP membrane.)
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including interceptiing chamber and screen chamber made of brick masonary in CM,RCC cover sla in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8M dia X 3.0 M effective depth complete all as specified and shown on drawing. No.CE/TD-1202/2003 Sheet 1/2 and 2/2 Amended up to dat and as directed.
Complete removal of existing treatment on walls and preparing old plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion complete all as specified and directed.
Complete removal of existing treatment on ceiling and preparation of old plastered or unplastered surfaces of ceiling and applying two coats of white wash on ceiling surfaces complete all as specified and directed.
Preparation of newly plastered or unplastered surfaces of celing and applying three coats of white wash on ceiling surfaces, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed.
Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, complete all as specified and directed.
75mm thick cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in floors, hard standing etc and laid in alternate bays complete and finished the even & fair and providings joints through out the thickness of plinth protection filed with mastic filling comprising one part of 01 bitumen 85/25 grade and three part of sand by weight all as specified and directed
Non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.11Sqm but n exc. 0.18Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
Non skid coloured ceramic tiles 7 - 8 mm thick area of each tile exceeding 0.18sqm but not exceeding 0.38sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles laid over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
Glazed ceramic coloured tiles (350x250mm)/(450x350mm) x 7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick back coat layer in cement mortar 1:4, complete all as specified and directed by Engr-In-Charge.
25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base floor finishing surface even and fair, complete all as specified and directed.
Taking down Chowkats or frames exc 1.5 sqm but n.exc 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down Chowkats or frames exc 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down shutters of any description exc 2.0 sqm each complete all as specified and directed.
Schedule 'A' Part XI (List of items of Works Pertains to collapsible gate in GE office Bldg )
35mm thick 2nd class hard wood plain, framed, panelled door shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified.
35mm thick 2nd class hard wood ,Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (b) supplied and fitted to chowkats complete, all as specified.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as specified & directed.
Factory made solid core PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC sheet, 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap inserted for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified & shown in relevant drawing of item No. 08080 in MES Schedule (Part-II) and directed by Engineer-in-Charge.
Mild steel butt hinges, medium weight, cold rolled,100mm long, complete all as specified.
Aluminium anodised, barrel tower bolts of extruded section of size 150mm and fixed, complete all as specified and directed.
Aluminium alloy handles, cast type, anodised of size 100mm and fixed, complete all as specified and directed.
Aluminium alloy handles, cast type, anodised of size 150mm and fixed, complete all as specified and directed.
300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section of cast aluminium alloy and fixed, all as specified and directed.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified.
Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
Sheet glass ordinary quality, 3mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as
specified and as directed.
Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples fixed in repair, complete all as specified.
Material and Labour in repair Sheet glass ordinary quality, 3mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane,including hacking out old broken glass complete all as specified and as directed.
Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified.
Steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, complete push pull or manual type, thickness of laths is 1.25 mm all as specified and directed.
Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
Applying one coat of synthetic enamel paint to old or previously untreated steel surfaces n.exc 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
Preparation of new wooden surfaces of any description, over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer,complete, all as specified and directed.
Applying two coats of synthetic enamel paint over a coat of red oxide primer to new or previously untreated steel surfaces n.exc 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
Supply and fixing in repairs Vitreous china Wash hand basin, white,oval type, of size 630x450mm,excluding taps, waste, chain and plug and porcelain stopper but including brackets cutting for and pinning in ends of brackets or erecting stand alongwith 32mm PVC waste pipe and brass chromium plated waste coupling, complete all as specified and directed.
Supply and fixing in repairs Vitreous china urinals, bowl type or half stall type of size 465x355x265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern and waste pipe),complete including poviding and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing with automatic flushing cistern with brackets, flush pipe, waste pipe grating and union for discharge pipe, complete all as specified and directed.
Preparation of old wooden surfaces of any description, over 10 cm width or girth and applying two coat of synthetic enamel paint ,complete, all as specified and directed.
Supply and fixing in repairs 15mm bore Stop valve cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete all as specified and directed.
Supply and fixing in repairs Vitreous china squatting pan (Orissa pattern) size 580 x 440 mm, snow white, with 'P' or 's' trap, front or back inlet and integral foot rests, complete connection to drain (outgoing pipe) and to flushing pipe and syphonage pipe etc.including lime concrete bedding, complete, all as specified and directed.
Supply and fixing in repairs Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union all as specified and directed.
15mm bore brass CP mixer for mixing hot or cold water, screwed for iron pipe and fixed in repairs, complete all as specified and directed.
Supply and fixing in repairs 15mm bore Stop valve cast copper alloy chromium plated fancy type with long shank and cup (concealed type) screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete all as specified.
Supply and fixing in repairs Bib taps 15mm bore of cast copper alloy chromium plated fancy type, screwed down, high presure with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule, fixed, complete all as specified and directed.
Supply and fixing in repairs Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms), complete all as specified and directed.
PVC connection 15mm size with length 600mm fixed in repair, complete all as specified and directed.
Soap dish, vitreous China white, approximate size160x160x90mm fixed with and including chromium plated brass screws and wooden/plastic plugs, fixed in repairs, all as specified and directed.
PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint fixed in repairs, to walls as soil pipe with & including clamps, complete all as specified and directed.
PVC (SWR) bends any radius 100mm bore fixed in repair, complete all as specified and directed.
PVC(SWR) branch piece, single (single Y) equal or unequal 100mm bore fixed in repair, complete all as specified and directed.
PVC (SWR) vent cowl for 110mm dia fixed in repair, all as specified and directed.
PVC (SWR) junction single (single T) 110mm bore equal or unequal, fixed in repair, complete all as specified and directed.
PVC (SWR) floor trap of 75mm dia of outlet, plain with grating including jointing with solvent cement fixed in repair, complete all as specified and directed.
Preparation of new plastered or unplastered surface of wall including cornices pilaster etc, and applying two coats of distemper oil emulsion over and including a coat of primer surface, complete as specified and directed.
PVC (SWR) pipes 75mm dia any length single socketed with rubber ring joint laid in trenches/floors as soil pipe, fixed in repair, complete all as specified and directed.
Ball brass valves, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule, 20mm bore fixed in repair, complete all as specified and directed.
Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, Complete all as specified and directed.
20mm bore Gun metal, globe or gate valves (ISI Marked), with iron wheel head, screwed both ends for iron pipe. fixed in repair, complete all as specified and directed.
Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, Complete all as specified and directed.
Steel water tubing of 15 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified.
Steel water tubing of 20 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified.
Sub main wiring with single core cable 2 x 6 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 4 Sq mm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including taking down old unsv sub main wiring of any type, complete all as specified and directed. Note:-2 wire of 6sqmm, 1 wire of 4sqmm and one run of pvc casing caping shall be measured as one unit.
MCB SP 16 Amps, 10 KA , 230V AC, ISI marked as per IS/IEC 60898-1 2002, IP 20 protected complete all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm , drilled and screwed including 3 nos. 8mm dia 25 mm long hex. head screw, complete with suitable polycaronate box with locking arrangement all as specified and directed .
Point wiring with two single core, 1.5 Sqmm (nominal area) size multistranded copper conductor cable and one single core 1.5 sqmm (nominal area) size copper conductor cable, as earth continuity conductor connected to common earth dolly,1100 volts grade , FRLS, PVC insulated unsheathed cable in and including concealled PVC conduit of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, Bend, PVC Conduits for crossisng etc. complete with PVC terminals box for mounting switches, sockets, fan regulators etc for the followings points:-
One light/Fan point controlled by one switch complete all as specified and as directed.
One 5 pin, 6 A socket outlet on the independent board. Complete all as specified and directed.
One 5 pin, 6 A socket outlet on the same board complete all as specified and as directed.
Taking down existing tarfelt including tiles and Demolition of concrete & screed bed complete from roof surfaces including parapets and lowering without disturbing the existing RCC roof slab and removing the same to a distance exc. 50m and n. exc. 100m incl roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed.
Ceiling rose, 3 terminal, surface bakelite 65 x 50mm complete all as specified and as directed.
Piano type switch, 1 way, 6 Amps, flush type, complete all as specified and as directed
Switch socket combination 5 pin, 6 Amps, flush type complete all as specified and as directed.
E/M PORTION :- Taking down carefully copper/aluminium point wiring for light, bell socket power socket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket, ceiling rose, celing fan etc and making good to disturbed surfaces of wall, floor etc to match with existing finishes complete all as specified and directed.
Socket outlet 2 in 1, 5 pin, 6 Amps, flush type complete all as specified and as directed.
All as per item No 10.91 here-in-before but with 2 x 2.5 sqmm size cables as phase and neutral and 1 x 2.5 sqmm size cable as earth continuity conductor for one 15/20 Amps socket outlet independent complete all as specified and as directed.
Supply and fix in replacement connecting,testing and commissioning of street light fitting 35 watt LED, IP-65 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 5 KV, prewired including three core PVC insulated , sheathed 1.5 sqmm multistranded aluminium conductor with 2 core 1.5 sqmm pvc insulated cable from junction box to light fitting complete all as specified.
Taking out old unsv ceiling fan from site if capacity 1200/1400mm sweep and replacing with new BLDC ceiling fan of 1200 mm sweep, 230 V, 50 hz, incl all connecting accessories complete all as specified and directed.
Switch socket combination 2 in 1, 6 and 16 Amps, flush type complete all as specified and directed.
Supply and fixing in repairs LED light fitting 1x 20W, 230V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Schedule 'A' Part XII (List of items of Works Pertains to Spl repair to Bldg No P-92 and Bldg No P-69 at AP-255 )
MCB SP 6 to 32 Amps, 10 KA,complete all as specified and directed.
Supply and Fixing in repair Sheet Metal enclosure for SPN DBs, 8 Ways, Double Door (IP-43), with netral link complete suitable for 240 Volts, AC, 50 Hz complete all as specified and directed.
Electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep complete all as specified and as directed.
Supply and fixing in replacement Sub main wiring with single core cable 2 x 4 sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade idrawn through PVC casing/caping 25 mm dia ISI marked fixed on wall/ceiling, alongwith 1x4 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly , complete all as specified and directed. Note:-Two runs of 4sqmm cable alongwith one run of of 4sqmm PVC insulated copper conductor as earh wire incl casing caping shall be measured as one unit.
MCB SPN 40 to 63 Amps 240V,complete all as specified and directed.
Point wiring complete with 1100 V grade 1.5 sqmm single core PVC insulated cable (FR) of multistranded copper conductor cable drawn through and including in stove enamelled steel conduit in wall with all connected accessories with provision of 1.5 sqmm insulated multistranded copper conductor (FR) as earth continuity wire and connecting to common earth dolly fixed to wall/ceiling /floor/roof including sunk pressed steel terminal boxs with 3mm thick plastic laminated sheet top cover for mounting fixtures etc suitable all as specified for one light point controlled by one flame proof switch 16 Amps 1 way complete all as specified and as directed.
LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size
Switch flame proof rotary type with termination box in LM6, 16 Amps, single pole 230 volts complete all as specified and directed.
Flame proof, weather prood distribution board 8 way (one MCB SPN as incommer and six MCB SP as outgoing) conforming to standards IS 2148 : 2004/ICE 60079-1 (2001) made up to LM6 material epoxy polyester powder coated including suitable size busbar complete all as specified and directed.
MCB DP 32 Amps, 10 KA , 230V AC, ISI marked as per IS/IEC 60898-1 2002, IP 20 protected complete all as specified and directed.
Single pointed air termination copper rod 12mm dia and 300 mm long incl support block complete all as speicified and as directed.
Galvanised Iron strip 32x6 mm as a roof conductor or down conductor complete all with saddles and fixing screws for fitting the strip above ground complete all as specified and directed .
GI pipe light grade 40 mm bore for cable protection fixed on poles or laid in trenches, under floor, ducts etc with fixing clamps, nuts bolts etc all as specified.
Lamp holder insulated body complete all as specified and as directed.
Earthing complete with galvanized Steel earth plate electrode 600 x 600 x
LED Lamp, CDL, 12 watt, B22 base complete all as specified and as directed.
3.15 mm thick, buried directly in ground (earth pit not less than 2.25 meters below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and incl galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by GI protection pipe light grade 15mm dia connected to main earth wire on pole or controll board GI pipe light grade 20mm bore for watering funnel with wire mesh PCC chamber pit in PCC 1:3:6 type C-1 40mm yhick Precast RCC -25 cover reincorced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50m complete all as sprecified and shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
stage.html
html • 0.05 MB
technical_832268.pdf
techsummary_832268.pdf
finance_832268.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
DRG87.pdf
Additional Documents • 4.43 MB
TENDER87.pdf
Tender Documents • 1.69 MB
BOQ_832268.xls
BOQ • 2.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .