| Sl No | Description | Qty | Unit | BHARAT CORP L1 | SREE PADMAVATHI ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00 | Supply, erection, testing and commissioning of 500KVA Diesel Generator set in Tower Block-I & II with following technical specification: 500 KVA - 400KW PRIME Rating – 500 KVA Kirloskar DG set. Engine Model: DV8ETA4G3, BHP : 608 Max at 1500RPM Alternator: 500 KVA, 3Ph, 4Wire, 415V, 50Hz,0.8 P.F A) DIESEL ENGINE: - "KIRLOSKAR" Make diesel engine Model Four cylinders, liquid cooled, turbocharged with after cooler, developing @ 1500 RPM. Inline, electric start, compression ignition, 4 stroke, designed to run continuously at 1500 RPM confirming to IS 10002, ISO- 3046, BS 5514 standard. Diesel Engine will comply with present CPCB- II norms. The diesel engine will comprise of following: - a) Dry type air cleaner
b) Exhaust Silencer suitable for canopy c) Expansion bellow d) Lube Oil cooler e) Full flow Lube oil filter | 1 | No | 57,37,000 ₹57.4 L | 60,00,000 ₹60 L |
| 1.01f) Fuel Filters (Pre and Micro) g) Radiator with pusher type fan and mounting h) In-line mono block fuel injection pump i) Mechanical governor and fuel feed pump j) Flywheel with starter ring and bell housing suitable for close coupling k) 12 Volt electric starter motor l) Battery charging alternator m) Microprocessor based KG934 (L1 )Controller mounted are fixed in power panel n) Protection System for - Low lube oil pressure High water temperature B) ALTERNATOR:- "KIRLOSKAR GREEN" make Alternator, suitable for continuous operation rated at 1500 rpm 415 V, 0.8 PF, 50Hz, 3Ph. in SPDP enclosure, self- excited & self- regulated, Brush less, floor mounted with Ball or Bearings on end shields. The alternator conforms to IS: 4722, BS EN 60034-1& will be suitable for tropical condition. | |||||
| 1.02C) BASE FRAME: - Suitable to couple above Engine & Alternator made from steel sheet metal. D) FUEL TANK: - 150 Liter Capacity, with Inlet & Outlet arrangement, air vent & drain plug arrangement. E) STANDARD GENSET CONTROLLER UNIT WITH CONTROL PANEL Genset controller unit ‘KG 934’ with totally enclosed, steel construction control panel suitable for indoor floor / wall mounting installation having following safeties and display parameters: Engine Display parameters - 1) Oil Pressure 2) Engine Coolant Temperature 3) Fuel Status 4) Engine speed 5) Battery Voltage 6) Engine Hours Mechanical Safeties (along with Display) - 1) Under/Over speed 2) Low Lube oil pressure 3) High engine coolant temperature Gen-set Display Parameters - 1) Phase Voltage 2) Line current 3) Frequency & PF 4) Average Voltage 5) Average Current | |||||
| 1.036) Phase kW & Total kW 7) kWH 8) kVA &kVAR Electrical Safeties (along with Display) - 1) Genset Under/Over voltage 2) Under/Over frequency 3) Phase Failure 4) Phase sequence reverse 5) Over Current 6) Over kW a) 3 Pole MCCB b) Control Fuse Base with Link (Glass Fuse) c) Power Terminal & Control Terminal Start & Stop Relay TECHNICAL SPECIFICATION OF KIRLOSKAR GREEN ACOUSTIC ENCLOSURE CONSTRUCTION Following are some technical features of Acoustic Enclosure:- 1. The enclosure is modular in construction 2. Base frame is made of Sheet metal. 3. Durable industrial locking system is provided on doors. 4. Doors are gasketed with high quality EDPN gasket. CORROSION RESISTANCE:- To make the enclosure weather proof: - 1. All sheet metal parts/components are hot dipped in seven tanks process, pretreated and passivated. | |||||
| 1.042. Sheet metal components are painted with P.P base power. 3. Base frame is epoxy coated. 4. Zinc passivated hardware is used to avoid rusting ACOUSTIC INSULATION: 1. Sound proofing of the enclosure done with quality Foam confirming to IS: 8183. 2. Acoustic form shall be fire retarded and fire resistant. 3. Attenuates are provided to control sound at entry and exit to and from the container. 4. Specially designed Residential Silencer is provided. VENTILATION AND AIR CIRCULATION: Exhaust pipe is thoroughly insulated by covering it with glass wool and further cladded in Enclosure. ELECTRICAL: Neutral Body earthing points at the sides of enclosure are isolated through Dough Moulded compound. SOUND LEVEL The canopies being offered are for output of < 75 dbA at a distance of 1- meter average around the set conforming CPCB IV+ Norms. | |||||
| 2.00 | Civil work Foundation for the size of 6Mtrs x 6Mtrs x height 1.0 Mtrs brick wall with post pcc concret 3 feet wth coarry dust filling for the plinth with complete 25mm cement concrete mat flooring and good finishing etc. | 1 | Job | 1,23,500 ₹1.2 L | 1,40,000 ₹1.4 L |
| 3.00 | Supply and clamping of 3 Runs 3 ½ x400 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. | 116 | Mts | 6,265 ₹7.3 L | 6,500 ₹7.5 L |
| 4.00 | Supply and fixing of brass cable gland for 3 ½ x400 sq.mm PVC LTUG armoured cable with earth connection (SD-174) | 10 | Nos | 1,000 ₹10,000 | 1,200 ₹12,000 |
| 5.00 | Supply and providing cable end termination of 3 ½ x400 sqmm PVC LTUG Aluminium armoured cable withnecessary aluminium cable sockets by crimping etc. with electrical connection complete | 10 | Nos | 1,300 ₹13,000 | 2,000 ₹20,000 |
| 6.00 | Supply and installation of 4 loop analogue addressable fire alarm panel, with 16 fire zone indicators, 2 x 40 character backlit LCD, 2 independent sounder circuits, Sound Alarms, Silence/Resound, Mute Buzzer, Accept, Reset buttons, 12 button alpha numeric key pad and 4 cursor keys, Fire, Fault, Test, Disablement, Delayed Mode, Alarms Silenced, Buzzer Muted, Sounders Disabled, Relays Disabled, Power, Supply Fault, CPU Fault, Sounder Fault and Earth Fault indicators, inbuilt battery charger with 2 x 7 AH 12 volts battery. Make: Morley IAS UK | 1 | No | 1,55,000 ₹1.6 L | 1,60,000 ₹1.6 L |
Updated dates
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
6 Nov 2025, 3:00 pmClosed
The Superintending Engineer, PWD.,
O/o. The Superintending Engineer, PWD., Buildings (C and M) Circle-1, Chepauk, Chennai-5
Provision of additional Diesel Generator set with AMF panel and Addressable Smoke Detection and Fire Alarm System in Tamil Nadu Government Dental College and Hospital, Chennai-3
2025_PWD_619014_1
PWD/BCMC1/67/2025-26
Open Tender
Electrical Works
120 days
TN Dental College and Hospital
Refer Tender Condition
8 documents required · 8 mandatory
₹0
₹72,000
7 Mar 2026
31 Oct 2025
6 Nov 2025
31 Oct 2025
6 Nov 2025
31 Oct 2025
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_740135.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
Provision500KVADGSet.pdf
Tender Documents • 0.82 MB
BOQ_740135.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid