Loading…
Loading…
Tender Value
₹87.2 L
EMD Value
₹1.7 L
Closing Date
28 Aug 2026, 11:00 am4d left
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnoverof [V/N or 'V' whichever is less; where V = Advertised value of the tenderin crores of Rupees N= Number of years prescribed for completion ofwork for which bids have been invited. The average annual contractualturnover shall be calculated as an average of "total contractualpayments" in the previous three financial years, as per the auditedbalance sheet. However, in case balance sheet of the previous year isyet to be prepared/ audited, the audited balance sheet of the fourthprevious year shall be considered for calculating average annualcontractual turnover. The tenderers shall submit requisite information asper Annexure-VIB, along with copies of Audited Balance Sheets dulycertified by the Chartered Accountant/ Certificate from CharteredAccountant duly supported by Audited Balance Sheet.
Experience in similar nature of work:- a) The tenderer must havesuccessfully completed any of the following during last 07(seven) years,ending last day of month previous to the one in which tender is invited:Three similar nature of works each costing not less than the amountequal to 30% of the advertised value of the tender, or Two similar natureof works each costing not less than the amount equal to 40% of theadvertised value of the tender, or One similar nature of work eachcosting not less than the amount equal to 60% of the advertised value ofthe tender. (b) (i) In case of tenders for composite works (e.g. worksinvolving more than one distinct component, such as Civil Engineeringworks, S&T works, Electrical works, OHE works etc. And in the case ofmajor bridges - substructure, superstructure etc.), the tenderer musthave successfully completed any of the following during last 07 (seven)years, ending the last day of the month previous to the one in whichtender is invited: Three similar nature of works each costing not lessthan the an amount equal to 30% of the advertised value of eachcomponent of the tender, or Two similar nature of works each costing notless than the amount equal to 40% of the advertised value of eachcomponent of tender, or One similar nature of work each costing not lessthan the amount equal to 60 % of the advertised value of eachcomponent of the tender. Note for b(i): Separate completed works ofminimum required values for each component shall also be consideredfor fulfillment of technical eligibility criteria. (b) (ii) In such cases, whatconstitutes a component in a composite work shall be clearly predefinedwith estimated tender cost of it, as part of the tender documents withoutany ambiguity. (b) (iii) To evaluate the technical eligibility of thetenderer, only components of work as stipulated in tender documents forevaluation of technical eligibility shall be considered. The scope of workcovered in other remaining components shall be either executed by thetenderer himself if he has work experience as mentioned in clause 7 (a)(ii) of Part-II of GCC or through subcontractor fulfilling the requirementsas per clause 7 of Part-II of GCC or jointly i.e., partly himself andremaining through subcontractor, with prior approval of Chief Engineerin writing. However, if required in tender documents by way of SpecialConditions, a formal agreement duly notarised, legally enforceable in thecourt of law, shall be executed by the main contractor with thesubcontractor for the component(s) of work proposed to be executed bythe subcontractor(s), and shall be submitted along with the offer forconsidering subletting of that scope of work towards fulfillment oftechnical eligibility. In case after the award of the contract or during theexecution of work it becomes necessary for the contractor to changesubcontractor, the same shall be done with subcontractor(s) fulfilling therequirements as per clause 7 of Part-II of GCC, with prior approval of theChief Engineer in writing.
The Similar nature of works for this instant tender shall be "Supply, installation, testing and commissioning of any LT/HT electrical work"
Tenderer must have to submit valid Electrical Contractor licenseas per Indian Electricity Rules for the respective category ofworks issued by Government Electrical License Board on orbefore the closing date of tender. Copy of the electricalcontractor license should be submitted along with the tenderoffer, otherwise, the tender will be summarily rejected.
51 conditions · 5 needing a document upload
Whether the cost of earnest money deposited
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
A : Electrical work for newly constructed RPF Barrak at Haibargaon Under SSE/Elect/P/CPK . B: BPB SDRH: Upgradation of OPD, minor OT, Consultation Rooms, Toilet complex, etc. including electrical works at IPD & OPD. (Electric General Service Portion). C : Construction of multi-storied hostel for MDTI of Lumding Near Children Park under Jurisdiction of ADEN/II/LMG(Electrical Portion)D: Construction of additional 20 bedded RCC Building Loco Running Room at BPB. (Electrical portion)
EL-LM-26-27-17~NFR
EL-LM-26-27-17
Open
Works - General
180 Days
Hojai, Assam
₹0
₹1.7 L
4 Aug 2026
4 Aug 2026
14 Aug 2026
302 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 25,96,021.18 | ||
| — | 400.00 | — | — | ||
| Laying, fitting, fixing and commissioning of LT/HT XLPE insulated, armoured power cables with aluminium conductors of different sizes, suitable for the required voltage grade, including proper dressing, clamping and securing of cables partly along poles/structures and partly in ground cable trenches as per site requirement. The work shall include excavation of trenches, sand bedding, protective covering with bricks/tiles, refilling and compaction, ensuring proper route marking and safety precautions as per relevant IS standards (IS:1255/IS:7098 or latest). It also includes loading, unloading, safe transportation and carrying of cables to site by contractor's own arrangement as directed by the Engineer-in-Charge. Termination and jointing shall be carried out using approved kits with proper crimping, sealing and ferruling to ensure reliable performance. Necessary testing such as insulation resistance, continuity and phase identification shall be done before commissioning, and the entire work shall be executed as per relevant IS specifications and instructions of the Engineer-in-Charge at site. | — | — | — | 16,372 | |
| — | 500.00 | — | — | ||
| Excavation of cable trench 1.0 m x 0.5 m below the GL with laying of armored cableand refilling the same by supply of Brick, Sand and Soil after digging the earth asper direction of Engineer at site & connection of armored Cable by supply and fixingof crimping lugs etc. | — | — | — | 60,895 | |
| — | 500.00 | — | — | ||
| Supply and laying of 100 mm diameter Cast Iron (CI) Pipe, Class-B, conforming to IS:1536:2001 with Amendment No. 1 & 3, including all necessary fittings, sockets, lead/rubber ring joints, clamps/supports wherever required, cutting, threading/drilling of pipe where necessary, alignment, jointing, testing and commissioning complete in all respects, as per the direction of the Railway Engineer-in-Charge at site. | — | — | — | 3,34,355 | |
| — | 500.00 | — | — | ||
| Supply, laying and commissioning of 110 mm (OD) diameter Double Wall Corrugated (DWC) HDPE pipe, PN-6.0 kgf/cm² pressure rating, suitable for cable protection and underground/over-ground applications, conforming to IS:14930 Part-II (latest revision), complete with all necessary accessories such as sockets, couplers, bends, end caps and other fittings.The pipe shall be laid partly above ground and partly underground as per site requirements and the direction of the Railway Engineer-in-Charge. | — | — | — | 1,37,325 | |
| — | 8.00 | — | — | ||
| Supply, installation, testing and commissioning of 160 Amps, 4 Pole, 36 kA MCCB with Ics = 100% Icu, having adjustable thermal and magnetic trip settings, suitable for 415 V, 3-phase, 4- wire LT system, conforming to IS:13947 (Part-II) / IEC 60947-2 (latest revision), complete with suitable terminals, connections, mounting accessories and all necessary hardware. The MCCB shall be suitable for reliable protection against overload and short-circuit conditions and shall be installed, tested and commissioned as per manufacturer's recommendations and the direction of the Railway Engineer-in-Charge at site. | — | — | — | 1,59,920 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing and commissioning of 125 Amps, 4 Pole, 25 kA MCCB with Ics = 100% Icu, having adjustable thermal and magnetic trip settings, suitable for 415 V, 3-phase, 4- wire LT system, conforming to IS:13947 (Part-II) / IEC 60947-2 (latest revision), complete with suitable terminals, connections, mounting accessories and all necessary hardware. The MCCB shall provide reliable protection against overload and short-circuit conditions and shall be installed, tested and commissioned as per the manufacturer's recommendations and direction of the Railway Engineer-in-Charge at site. | — | — | — | 93,420 | |
| — | 15.00 | — | — | ||
| Supply, installation, testing and commissioning of 63 Amps, 4 Pole, 25 kA MCCB with Ics = 100% Icu, having adjustable thermal and magnetic trip settings, suitable for 415 V, 3-phase, 4- wire LT system, conforming to IS:13947 (Part-II) / IEC 60947-2 (latest revision), complete with suitable terminals, connections, mounting accessories and all necessary hardware. The MCCB shall provide reliable protection against overload and short-circuit conditions and shall be installed, tested and commissioned as per the manufacturer's recommendations and direction of the Railway Engineer-in-Charge at site. | — | — | — | 1,84,950 | |
| — | 1.00 | — | — | ||
| Manufacturing, supply, erection, testing and commissioning of outdoor type Feeder Pillar, fabricated from suitable gauge CRCA/GI sheet steel, complete with hinged and lockable door, suitable for 415 V, 3-phase, 4-wire LT system, equipped with RYB LED indication lamps and three- phase & neutral aluminium busbars of minimum 200 Amp current-carrying capacity for each phase and neutral, with suitable insulation/shrouding. The feeder pillar shall be of minimum overall size 1000 mm (H) x 600 mm (W) x 350 mm (D) and shall be suitable for outdoor installation with adequate weather and corrosion protection. The feeder pillar shall be grouted/fixed on ground using 4 Nos. suitable mounting angles of size 50 x 50 x 6 mm, each of 500 mm length, including all necessary foundation/fixing arrangements. The item shall also include complete end termination of incoming/outgoing cables with suitable-size compression cable glands, cable lugs, shrouds, ferrules, sleeves and all necessary accessories. The work shall include all materials, fabrication, transportation, erection, wiring, termination, testing and commissioning complete in all respects as per approved drawings and the direction of the Railway Engineer-in-Charge at site. | — | — | — | 16,551.3 | |
| — | 8.00 | — | — | ||
| Supply, installation, testing and commissioning of 100 Amps, 4 Pole, 25 kA MCCB with Ics = 100% Icu, having adjustable thermal and magnetic trip settings, suitable for 415 V, 3-phase, 4- wire LT system, conforming to IS:13947 (Part-II) / IEC 60947-2 (latest revision), complete with suitable terminals, connections, mounting accessories and all necessary hardware. The MCCB shall provide reliable protection against overload and short-circuit conditions and shall be installed, tested and commissioned as per the manufacturer's recommendations and direction of the Railway Engineer-in-Charge at site. | — | — | — | 98,640 | |
| — | 20.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of LT cable termination kit suitable for 50 sq.mm, 4-core Aluminium conductor, 1.1 kV grade XLPE/PVC insulated LT power cable, complete with suitable compression type aluminium cable lugs, brass cable glands, gland shrouds, insulation sleeves, sealing/insulation tapes, earthing accessories, nuts, bolts and all other necessary accessories required for proper termination. The termination kit shall be suitable for indoor/outdoor application as required and conform to relevant IS/IEC standards and manufacturer's recommendations. The item shall include cable-end preparation, gland fixing, lug crimping, connection, insulation, testing and commissioning complete in all respects as per the direction of the Railway Engineer-in-Charge at site. | — | — | — | 76,000 | |
| — | 20.00 | — | — | ||
| Supply, fitting and fixing of foundation bolt assembly comprising minimum 08 Nos. foundation bolts of minimum 25 mm diameter and 750 mm length, manufactured from high- strength/special-grade steel, complete with matching nuts, plain/spring washers, anchor plates of minimum 20 mm thickness and suitable steel templates for accurate positioning and alignment of the bolts. The work shall include fabrication, supply, transportation, positioning, alignment, fixing and all necessary accessories required for proper installation in the foundation, complete in all respects as per the direction of the Railway Engineer-in-Charge at site. | — | — | — | 43,015.6 | |
| — | 40.00 | — | — | ||
| Supply, installation, testing and commissioning of 45 Watt outdoor LED street light luminaire, complete with heat-resistant toughened glass and suitable connecting lead, suitable for 230 V AC supply, having minimum IP66 ingress protection and Class-I electrical protection. The luminaire shall have system efficacy of minimum 105 lm/W, pressure die-cast aluminium housing with suitable powder-coated finish, power factor greater than 0.95, total harmonic distortion (THD) less than 10% and inbuilt surge protection of minimum 5 kV. The luminaire shall be suitable for outdoor street-lighting applications and shall provide optimum illumination and uniform light distribution to ensure maximum visibility during night-time, particularly for persons with low visibility. The item shall include all necessary mounting/fixing accessories, connectors, wiring, hardware and complete installation, testing and commissioning as per the manufacturer's recommendations and direction of the Railway Engineer-in-Charge at site. | — | — | — | 1,53,433.2 | |
| — | 0.90 | — | — | ||
| Supply of Ordinary Portland Cement (OPC), Grade 53, conforming to IS:269 (latest revision), in fresh and sound condition, free from lumps and other impurities, suitable for use in civil and foundation works. The cement shall be supplied in standard manufacturer-sealed bags and shall be accompanied by relevant test certificates wherever required. The work shall include transportation, loading, unloading, stacking and storage at site as per applicable standards and the direction of the Railway Engineer-in-Charge. | — | — | — | 5,771.26 | |
| — | 100.00 | — | — | ||
| Supply, installation, testing and commissioning of 75 x 16 mm hot-dip galvanized (GI) nut and bolt set, complete with matching nuts, washers and all necessary accessories. The GI nut and bolt shall be of approved quality, corrosion-resistant and suitable for fixing of electrical structures, poles, brackets, channels and associated supports. | — | — | — | 733 | |
| — | 10.00 | — | — | ||
| Earthing complete with 50mm dia, 3.65mm thick , 3 mtr long GI pipe to be erected inside an earth pit of height 3.75 mtr& diameter 30 cm to be filled by alternate layers of salt (2) & charcoal (3) of width 50 cm each from the bottom and the rest by earth. Perforated holes of dia 12 mm each to be made in the pipe by drilling and a gap of 30 cm is to be maintained between the holes up to a height of 2.5 mtr from bottom. A second layer of perforated holes of same dimension are also to be made at an angle of 90o with the earlier layer of holes by keeping a vertical distance of 15 cm. A cement concrete chamber of size 30x30x30 cm and thickness 6 cm in ratio 1:3:6 by cement sand & 19mm and down stone chips is to be made around the pipe. The size of CC top cover is 24cmx24cmx4cm with provision of metallic folding handle is to be made. The cover to be provided on the 3mm top groove of earth pit (flash) as per direction of Railway Engineer. Earth continuity by 25x 5mm GI strip through alkathene pipe.75x16 mm GI nut, bolt and spring/flat washer has to be provided as per instruction of Railway Engineer. The connection of earth continuity wire with earth electrode to be made by GI soldering terminal socket of suitable size. The distance of earth electrode form building/other earthing system to be maintained by observing IE rules. GI pipe Make - TATA, BANSAL, JINDAL | — | — | — | 16,098 | |
| — | 80.00 | — | — | ||
| Supply of materials and wiring of light point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch(with indicator type) to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. Make - Cable- Finolex, Havells, KEI, Polycab Casing & Capping/Conduit - Diamond, Presto Plast, Richa C/Rose & Switch - Crabtree, Anchor, Legrand. | — | — | — | 34,108 | |
| — | 40.00 | — | — | ||
| Supply of materials and wiring of fan point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sqmm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch(with fan marking) and module type step fan regulator of 100 W to beprovided on good quality modular plate and frame ofsuitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVCTee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour ofthe surface. | — | — | — | 20,071.2 | |
| — | 80.00 | — | — | ||
| Supply, fitting, fixing,connection & commissioning of 18/20 watt LED indoor fitting complete set with LED tube and other accessories. The fitting shall be connected by 1.5sq mm flexible copper wire through pvc pipes/casing as required at site. | — | — | — | 25,136 | |
| — | 40.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required | — | — | — | 1,09,200 | |
| — | 10.00 | — | — | ||
| Supply of materials and wiring of modular type mobile charging through concealed/surface wiring with mobile keeping tray by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch 3 no and 6/10 amp 5 pin modular socket 3 nos to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper size (i.e. thickness of mounting boxes of 3 mm and inside width of box should be 50 mm).All other accessories i.e. PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site color of the surface. | — | — | — | 7,351.3 | |
| — | 2.00 | — | — | ||
| Supply, fitting, fixing,connection, commissioning and wiring of AC point by good quality accessories with proper connection complete with 16amps MCB and plug pointwiring by 6 sq mm single corePVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm singlecore PVC insulated unsheathed flexible copper wire to beprovided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.ethickness of mounting boxes of3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVCTee, Bend etc will be supplied by contractor. | — | — | — | 934.52 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of 1.5 Ton Inverter Split Air Conditioner, BEE 5-Star rated, suitable for operation on 230 V AC, single phase, 50 Hz supply, having copper condenser and evaporator coils, eco-friendly refrigerant, nominal cooling capacity of approximately 1.5 Ton / 4500 kcal/hr, complete with indoor and outdoor units and all standard accessories as per OEM requirements. The item shall include suitable copper refrigerant piping, interconnecting cable, drain pipe, insulation, remote control, necessary mounting/fixing hardware, electrical connections and other accessories required for complete installation. One pair of suitable heavy-duty outdoor wall mounting stands shall also be provided. The work shall include drilling, fixing, installation, testing and commissioning of the RAC and making good/re-mending of the wall, plaster, flooring or other surfaces affected during installation, complete in all respects. The entire work shall be executed as per OEM recommendations and the direction of the Railway Engineer-in- Charge at site. | — | — | — | 1,09,520 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of wall-mounted automatic voltage stabilizer suitable for 1.5 Ton Split Air Conditioner, with copper winding, suitable for single-phase 230 V, 50 Hz supply, having wide input voltage range of 90 V to 300 V and regulated output voltage range of 195 V to 245 V, with suitable capacity for 1.5 Ton AC, complete with high/low voltage cut-off protection, overload/short-circuit protection, time-delay protection, digital voltage indication/display and all necessary mounting accessories, wiring and connections. The stabilizer shall conform to IS:8448:1989 (latest revision) and shall be suitable for continuous and reliable operation with the specified air-conditioning unit. The work shall include supply, wall mounting, installation, testing and commissioning complete in all respects as per the manufacturer's recommendations and direction of the Railway Engineer-in-Charge at site. | — | — | — | 9,000 | |
| — | 4.00 | — | — | ||
| Supply, fitting, fixing, testing, installation and commissioning of 2 kVA single-phase pure sine-wave digital inverter based on MOSFET-PWM technology, suitable for operation on 230 V AC, 50 Hz supply, conforming to IS:13314 (latest revision), complete with necessary protection features, indication/display, input/output terminals, suitable enclosure, mounting arrangements and all standard accessories required for satisfactory operation. The work shall include all necessary consumables, wiring, connectors, lugs, fasteners and fixing accessories required for complete installation. A valid warranty certificate shall be furnished along with the equipment. The entire work shall be executed, tested and commissioned as per the manufacturer's recommendations and the direction of the Railway Engineer-in-Charge at site. | — | — | — | 36,550 | |
| — | 8.00 | — | — | ||
| Supply, installation, testing and commissioning of 120 Ah, 12 V Sealed Maintenance Free (SMF) Valve Regulated Lead Acid (VRLA) battery, conforming to JIS C:8702 (Part 1, 2 & 3) / latest applicable standard, suitable for use with inverter/UPS systems, complete with suitable terminals, connectors, interlinking accessories, battery rack/tray and all necessary fixing arrangements. The battery shall be supplied in fresh condition with valid test certificate and shall have a minimum warranty of 02 years from the date of commissioning. The work shall include all consumables, lugs, connectors, cables, fasteners and other accessories required for proper installation and satisfactory operation, as per the direction of the Railway Engineer-in-Charge at site. | — | — | — | 98,040 | |
| — | 350.00 | — | — | ||
| Supply, laying, wiring, testing and commissioning of concealed main-line wiring using 1.1 kV grade HRFR PVC insulated, single-core, 10 sq.mm multi-strand flexible copper cable conforming to IS:694 (latest revision), drawn through 25 mm dia heavy-duty PVC conduit pipe of approved quality, including necessary bends, couplers, junctions, saddles/clamps and other accessories. The work shall also include provision of earth continuity conductor of suitable size copper wire, complete with suitable lugs, connectors, terminals and all necessary accessories. The wiring shall be properly concealed, dressed, secured and terminated at both ends, including testing for insulation resistance, continuity and earth continuity, complete in all respects as per the direction of the Railway Engineer-in-Charge at site. | — | — | — | 84,521.5 | |
| — | 800.00 | — | — | ||
| Supply, laying, wiring, testing and commissioning of concealed sub-main wiring using 2 Nos. 4 sq.mm PVC insulated, unsheathed, multi-stranded FRLS copper cables conforming to IS:694 (latest revision), drawn through suitable size PVC conduit pipe, complete with necessary bends, couplers, junction boxes, saddles/clamps and other accessories. The work shall also include provision of 1 sq.mm PVC insulated, unsheathed, multi-stranded copper earth continuity conductor, including suitable lugs, connectors, terminals and all necessary accessories. The wiring shall be properly concealed, dressed, secured and terminated at both ends, including testing for continuity, insulation resistance and earth continuity, complete in all respects as per the direction of the Railway Engineer-in-Charge at site. | — | — | — | 61,616 | |
| — | 10.00 | — | — | ||
| Supply, wiring, testing and commissioning of concealed exhaust/wall bracket fan point with 1.5 sq.mm single-core, multi-stranded, PVC insulated and unsheathed FRLS copper cable, conforming to IS: 694 (latest revision), drawn through 19 mm dia rigid PVC concealed conduit having minimum 2 mm wall thickness, including all necessary bends, couplers, junctions and other accessories. The work shall include provision of ceiling rose and 10 AX, 1-way modular switch, mounted in suitable ½-module concealed unbreakable GI modular box with 2-module cover plate, complete with all necessary terminals, connectors, screws and fixing accessories. Earth continuity shall be provided through 1.0 sq.mm single-core, multi-stranded, green-coloured PVC insulated FRLS copper wire, conforming to IS: 694 (latest revision), including necessary lugs, connectors and accessories. The complete wiring shall be properly concealed, dressed, terminated and securely fixed, including testing for continuity, insulation resistance and earth continuity, complete in all respects as directed by the Railway Engineer-in-Charge at site. | — | — | — | 3,129 | |
| — | 10.00 | — | — | ||
| Supply, erection, testing & commissioning of 300 mm sweep ventilating type air flow exhaust fan suitable for single phase 230 volt AC supply including fixing arrangement by allied engineering works as per direction at site Engineer.. All consumables regarding fixing arrangement will be supplied by the contractor as per the direction of engineer in charge at site. | — | — | — | 12,690.6 | |
| — | 1000.00 | — | — | ||
| Supply, wiring, testing and commissioning of concealed sub-main line with 2 Nos. 6 sq.mm single-core, multi-stranded, PVC insulated and unsheathed FRLS copper cables, conforming to IS: 694 (latest revision), drawn through suitable size rigid PVC conduit pipe, including all necessary bends, couplers, junctions and accessories. Earth continuity shall be provided through 1.0 sq.mm single-core, multi-stranded, PVC insulated and unsheathed green-coloured FRLS copper wire, conforming to IS: 694 (latest revision), including necessary lugs, connectors and fixing accessories. The complete work shall include proper dressing, termination, fixing and testing for continuity, insulation resistance and earth continuity, complete in all respects as directed by the Railway Engineer-in-Charge at site. | — | — | — | 99,680 | |
| — | 4.00 | — | — | ||
| Supply, fitting, fixing, connection, testing and commissioning of 400 mm sweep, 230 V AC, single-phase, high-speed pedestal fan with metallic body, complete with suitable motor, fan guard, blades, stand and necessary accessories, including warranty certificate. The fan shall be of approved make and model as directed by the Engineer-in-Charge. All necessary materials and consumables required for fitting, fixing, connection and commissioning, including screws, fasteners, connectors, etc., shall be supplied by the Contractor at his own cost. The complete work shall be carried out as per the direction of the Engineer-in-Charge at site, complete in all respects. | — | — | — | 13,983.84 | |
| — | 400.00 | — | — | ||
| Supply and laying of 63 mm dia HDPE pipe, having pressure rating of 6.0 kgf/cm² (PN-6), including laying along poles, beams and brackets using 25 x 5 mm MS clamps, complete with required nuts, bolts, washers and other fixing accessories. Where required, the pipe shall be laid underground by excavating a trench of minimum 1.0 m depth, including proper dressing and backfilling of the trench after laying. Necessary compression sockets, short-radius compression bends and other compatible HDPE pipe fittings shall be provided as required and as directed by the Railway Engineer-in-Charge.The complete work shall include all necessary materials, fittings, clamps, supports, excavation, fixing and accessories, complete in all respects as directed by the Railway Engineer-in-Charge at site. | — | — | — | 39,504 | |
| — | 1.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of 80 litres capacity drinking water cooler with built-in water purification system, suitable for 230 V AC, single-phase, 50 Hz supply, having UV + RO water purification system with SS-304 grade water-contacting components/tank, as applicable. The RO filtration system shall have a minimum filter life/capacity of 10,000-12,000 litres. The UV water purification system shall conform to IS: 14724 (latest revision). The unit shall be complete with all necessary fittings, connections, accessories and consumables required for proper installation and commissioning. The equipment shall be supplied with a minimum 5 years comprehensive warranty, including warranty certificate. The complete work shall be carried out as per the specifications and directions of the Railway Engineer-in-Charge at site, complete in all respects. | — | — | — | 89,500 | |
| — | 1.25 | — | — | ||
| Supply and erection of PCC/RCC works for foundation of columns, pillars, posts, struts, etc., excluding the cost of cement, shuttering and centering. The CC block shall be 300 mm dia., with its height extending up to the required pole depth below Ground Level (GL), 300 mm above GL and 100 mm below the base plate, including necessary tie-muffing of DP (Double Pole) and all associated works, complete as directed by the Railway Engineer-in-Charge.(a) PCC 1:3:6 (M-10) - 1 part cement, 3 parts sand and 6 parts graded stone aggregate of 20 mm nominal size, including mixing, laying, compacting and curing, complete in all respects as per relevant specifications and directions of the Railway Engineer-in-Charge at site. | — | — | — | 3,303.82 | |
| — | 20.00 | — | — | ||
| Supply of materials and wiring of 16 amps plug point through concealed wiring by 4 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1sq mm single core PVC insulated unsheathed flexible copper wire and modular type16 amps controlling switch(with indicator type) and3 modular 16 Amps 6 Pin universal socket to be providedon good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50mm). All other necessary accessories i.e PVC Tee, Bendetc will be supplied bycontractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour ofthe surface. | — | — | — | 8,897.8 | |
| — | 10.00 | — | — | ||
| Supply and testing of 6.0 m long GI octagonal pole, complete with foundation bolts, loop box made of Bakelite sheet, one 6 A SP MCB, 16 sq.mm stud-type connector and all necessary accessories. The octagonal pole shall be hot-dip galvanized in a single dip, with uniform zinc coating and suitable for outdoor installation. The pole shall be complete with base plate, foundation bolts and other required accessories.Technical specifications of the pole shall be as follows:Type: Octagonal GI Pole, hot-dip galvanized in single dipOverall Height: 6.0 mTop Diameter (A/F): 70 mmBottom Diameter (A/F): 130 mmSheet Thickness: 3 mmBase Plate (L x B x T): 200 x 200 x 12 mmFoundation Bolt: 4 Nos. x 20 mm diaPitch Circle Diameter (PCD): 200 mmFoundation Bolt Length: 600 mmProjected Bolt Length: 100 mmLoop Box: Bakelite sheet typeMCB: 1 No. 6 A SPCable Connector: 16 sq.mm stud-type connectorThe pole shall be supplied complete with all necessary nuts, washers, foundation bolts, fixing hardware and accessories. The complete work shall include testing and inspection of the pole and associated accessories before installation, as directed by the Railway Engineer-in-Charge at site, complete in all respects. | — | — | — | 1,30,000 | |
| — | 10.00 | — | — | ||
| Supply, fitting and fixing of 1.0 m long GI single-arm bracket (header) with lamp holder, complete with suitable nuts, bolts, washers and all necessary fixing accessories. The bracket shall be securely fixed to the GI octagonal pole and properly aligned for mounting of the light fitting. The complete work shall be carried out as per the direction of the Railway Engineer-in-Charge at site, complete in all respects. | — | — | — | 20,000 | |
| — | 4.00 | — | — | ||
| Supply & fixing of ISI marked portable fire extinguisher dry chemical powder - A,B C type, 6 Kg composite / SS / Aluminium cylinder of same fire rating as per latest BIS . Specification - IS: 15683-2018 and as per Specific service pressure requirement for the use. | — | — | — | 9,960 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of dust-proof, vermin-proof, rodent- proof, weather-proof, chemically treated and dry-powder-coated LT outdoor wall-mounted/floor- mounted, rain-shed type cubical panel board, fabricated from 2 mm thick CRCA sheet steel, mounted on a suitable MS channel/angle iron frame, complete with all necessary hardware, supports, glands, terminals and accessories.The panel shall be provided with 250 A, 4-pole, 4-way electrolytic-grade copper busbar, complete with all internal connections using suitable-size copper bus strips/cables. The busbar chamber shall consist of 3-phase and neutral copper busbars of the same current rating, suitably supported and insulated. The panel shall also be provided with a suitable analogue metering module for measurement of electrical parameters.The panel enclosure shall be suitably treated against corrosion and shall be dry-powder coated, suitable for outdoor installation. The panel shall be provided with a suitable rain shed, gasketed doors and necessary arrangements to make it dust-proof, vermin-proof, rodent-proof and weather-proof. The panel shall be mounted on a suitable MS channel/angle frame wherever required.The panel shall be painted with two coats of suitable primer and two coats of exterior-grade finish coating by spray painting, or alternatively finished with approved dry-powder coating, as specified.The panel shall comprise the following switchgear:63 A, 4-Pole, 25 kA MCCB - 2 Nos.32 A, 4-Pole MCB - 2 Nos.The complete internal wiring and interconnections shall be carried out using suitable-size copper busbars/cables, properly terminated with suitable lugs, ferrules and connectors. All components shall be of approved make and rating and shall be suitably coordinated with the system requirements.Panel drawings, GA drawing, SLD and internal wiring diagrams shall be submitted for approval of the competent authority before fabrication. The panel shall be inspected, tested and commissioned after fabrication and installation. All necessary materials, accessories, hardware, supports, cable glands, lugs, ferrules, labels, nameplates, earthing arrangements and consumables required for complete installation and commissioning shall be included in the scope.The complete work shall be carried out in accordance with relevant IS/IEC standards and Railway specifications, and as per the direction of the Railway Engineer-in-Charge at site, complete in all respects. The control panel should be designed and manufactured by the CPRI and ISI.ISO approved manufacturer. | — | — | — | 1,03,600 | |
| — | 1.00 | — | — | ||
| Supply, wiring, testing & commissioning of concealed call bell point wiring by FR-LSH PVC insulated and unsheathed 1.5 sq mm, single core flexible copper wire concealed on wall through PVC rigid conduit pipe/Polyethylene pipe of dia not less than 20 mm dia with all types of joints and bends as required complete with 6 amps bell push controlling switch fitted on half flush MS board with hylem sheet top and earth continuity wire by PVC insulated and unsheathed 1 sq mm ,single core multi strand copper wire complete to be concealed in wall including supply, fixing, testing & commissioning of call bell "Ding Dong/ Multitune door bell". Wiring through Double lock PVC casing capping of not less than 19 mm width & minimum thickness of 0.85 mm maybe provided, if required as per instruction of Engineer-incharge at site. | — | — | — | 408.52 | |
| — | 4.00 | — | — | ||
| Supply and wiring of geyser point by good quality accessories with proper connection complete with 15 amps plug point and16 amps DP MCB overload protection, through concealed wiring by 4 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire: All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. | — | — | — | 1,875.72 | |
| — | 4.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of 2.0 kW, 25 litres capacity, 5-Star rated electric storage water heater (geyser) with suitable plastic/ABS outer body, suitable for 230 V AC, single-phase, 50 Hz supply, complete with heating element, thermostat, thermal cut-out, temperature control, safety valve, suitable inlet/outlet connections, mounting brackets and all necessary accessories. The water heater shall be energy efficient and suitable for continuous domestic/commercial use, with all necessary electrical and plumbing accessories required for proper installation and commissioning. The complete work shall be carried out as per the relevant standards/specifications and the direction of the Railway Engineer-in-Charge at site, complete in all respects. | — | — | — | 65,960 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-26-27-17final.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].