Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC 10 BRIJ VATIKA LAXMIPURA JAIPUR RAJASTHAN 302022 | JAIPUR | JAIPUR | RAJASTHAN | 302022 | L1 | Accepted-AOC Awarded by Competent Authority |
| Sl No | Description | Qty | Unit | R K ENTERPRISES L1 |
|---|---|---|---|---|
| 1.01 | SH -I
Earthing with G.I. earth pipe 4.5 mtrs long x 40mm dia i/c
accessories and Pdg. masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt) complete as reqd | 4 | Job | 32,984 ₹38,921.12 Lowest |
| 1.02 | Providing and laying earth connection from earth electrode
with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth
electrode including connection with G.I. thimble excavation and refilling etc as reqd. | 15 | mtr | 4,395 ₹5,186.1 Lowest |
| 1.03 | Providing and fixing 6 SWG dia GI wire on surface
or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring cable etc. as reqd | 25 | mtr | 1,500 ₹1,770 Lowest |
| 1.04 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required .
(a). 4 way (4+12), Double door | 1 | No | 8,977 ₹10,592.86 Lowest |
| 1.05 | Supplying and fixing following rating four pole 415 V isolator in the existing MCBDB complete with connections, testing and commissioning etc as reqd.
(a). 63 Amp | 2 | No | 2,472 ₹2,916.96 Lowest |
| 1.06 | Supplying and fixing 5 A to 32 A rating 240/415 volt 10 KA "C" curve MCB suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc as reqd.
(a). Single pole | 15 | Nos | 4,590 ₹5,416.2 Lowest |
| 1.07 | (b) Triple Pole | 2 | Nos | 2,406 ₹2,839.08 Lowest |
| 1.08 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface recessed steel/PVC conduit as reqd.
(a) 2x1.5 Sq mm | 100 | Mtr | 8,400 ₹9,912 Lowest |
| 1.09 | (b) 3x1.5 sq mm | 50 | Mtr | 5,700 ₹6,726 Lowest |
| 1.10 | {c}4x1.5 sq mm | 50 | Mtr | 7,150 ₹8,437 Lowest |
Tender Value
₹3.9 L
EMD Value
₹7,725
Closing Date
4 Aug 2025, 4:00 pmClosed
Executive Engineer Electrical BSNL Gorakhpur
Telephone Exchange Raptinagar Gorakhpur
Repairing of 32.50 KVA EA set at TE Sardarnagar and rectification of Electrical wiring faults at OLT location Sardarnagar , Pipraich in OA Gorakhpur
2025_BSNL_242337_1
33/TED/GKP/2025-2026
Open Tender
Electrical Works
Item Rate
90 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
ACCOUNTS OFFICER(Cash)BSNL O/o The GMTD GORAKHPUR
₹7,725
16 Sept 2025
23 Jul 2025
5 Aug 2025
23 Jul 2025
4 Aug 2025
23 Jul 2025
SH -I Earthing with G.I. earth pipe 4.5 mtrs long x 40mm dia i/c accessories and Pdg. masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt) complete as reqd
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and refilling etc as reqd.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring cable etc. as reqd
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required . (a). 4 way (4+12), Double door
Supplying and fixing following rating four pole 415 V isolator in the existing MCBDB complete with connections, testing and commissioning etc as reqd. (a). 63 Amp
Supplying and fixing 5 A to 32 A rating 240/415 volt 10 KA "C" curve MCB suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc as reqd. (a). Single pole
(b) Triple Pole
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface recessed steel/PVC conduit as reqd. (a) 2x1.5 Sq mm
(b) 3x1.5 sq mm
{c}4x1.5 sq mm
(a) 2x2.5 Sq mm
(b) 3x2.5 sq mm
{c}6x2.5 sq mm
Supply aqnd fixing following piano type switch / socket on the existing switch box / cover including connections etc as reqd. (a)5/6 amps switch
(b) 5 Amp 3pin Socket
© 15 Amp Switch
(d) 15 Amp 6pin Socket
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 20 mm dia
(b) 25 mm dia
Supplying and fixing of 40/32 mm dia x 1.50 mtr long GI pipe (medium class) bracket for mounting of street light fitting on wall bending the pipe to the required shape2 nos 20 mm x 3 mm flat iron clamps with nuts and bolts and washers painting the flat iron with primer and finish paint etc as reqd.
Supply and fixing of 45 watt LED type energy saver with inbuilt day night sensor street Light fitting i/c connection ,testing etc complete as reqd (Havells or ss make)
Providing and fixing 20 watt LED tube fitting i/c connection with 1.0 sq mm copper wire as reqd.
Replacement of 63 Amp Kit Kat fuse unit i/c fixing, connection, etc complete as reqd. (M/S L&T/Havells/S.s make)
Supply and Fixing of 1200 mm sweep ceiling fan i/c regulator, connection, testing etc as reqd.
Supply and Fixing of electronic regulatorfor ceiling fan i/c connection, testing etc as reqd.
Replacement of 63 Amp 4 pole on load change over switch in sheet steel enclosure i/c connection, testing etc complete as reqd. (M/S HPL/Havells/S.s make)
Visit charges of the skilled mechanic with helper for tracing out various faults of EI /engine testing complete as required.
Running test of EA set on load for 1 Hr by providing required diesel & making connections properly on both ends of EA set etc.complete as reqd
Replacement of following faulty items in existing LT panels etc. i/c connection, testing etc. complete as required. (a ) 63 Amp TPN SFU (HPL)
(b ) 32 Amp TPN SFU
(c ) 63 Amp HRC fuse
(d ) 32 Amp HRC fuse
Refilling of existing 4.5 Kg fire extinguisher i/c pressure testing etc complete as reqd.
Replacement of damaged Hose & horn pipe on existing fire extinguisher etc complete as reqd.
S/F of electronic battery charger for charging of starting battery of DG set on UPPCL supply i/c connection testing etc. complete as reqd.
Wiring of control wiring & making arrangement for starting with starting key panel i/c connetion testing etc as reqd.
Replacement of solenoid switch i/c connetion testing etc as reqd.
Repairing and overhauling of Kirloaskar make 32.5 kVA engine i/c replacement of following parts, testing etc complete as reqd PART A (Parts) (a) PISTON ASSEMBLY
SET OF RINGS
INTERMEDIATE RING: 1.1MM
OIL SPRAY NOZZLE ASSLY
SEALING RING CAP
WASHER
COMBINED LEAK OFF PIPE NOZZLE TO PUMP (M12 BANJO)
BUSH FOR INJECTOR
Part B -Job Work- Head Repair
Labour for EA repair
FUEL PUMP repairing & calibration
INJECTOR NOZZLE Repairing
Oil Cooler assembly
Alternator Reassembling
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .