Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical as Per Attachment |
| 2 | Accepted-Technical | Accepted-Technical as Per Attachment |
| 3 | Rejected-Technical | Rejected-Technical as Per Attachment |
Tender Value
₹8.4 L
EMD Value
₹16,847
Closing Date
1 Jun 2026, 6:00 pmClosed
Executive Engineer PHED Division Malpura
Executive Engineer PHED Division Malpura
Construction and Commissioning of 3 nos 150mm dia.Single Phase Tubewell with PVC tank At village Thadoli, Bhasoo, Dabardooba under block Todaraisingh District Tonk
2026_PHCJA_561236_1
EE PHED DIV MALPURA 37/2026-27
Open Tender
Civil Works - Water Works
Percentage
20 days
Executive Engineer PHED Division Malpura
As Per Tender Document
3 documents required · 3 mandatory
₹1,000
Executive Engineer PHED Division Malpura
₹16,847
Yes
11 Jun 2026
21 May 2026
2 Jun 2026
21 May 2026
1 Jun 2026
21 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. | |||||
| 1.01 | Nominal bore 150 mm dia. | 300 | Mtr | 726 | ₹2,17,800 |
| 1.02 | Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr. | 120 | Mtr | - | - |
| 2Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes | |||||
| 2.01 | 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) | 45 | Mtr | 1,933 | ₹86,985 |
| 3Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. | |||||
| 3.01 | 150 mm dia | 3 | Each | 812 | ₹2,436 |
| 4 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. | 3 | Each | 696 | ₹2,088 |
| 5Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. | |||||
| 5.1 | Above 2.0 KW | 6.72 | KW | 13,050 | ₹87,696 |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.16 MB
Tendernotice_2.pdf
PDF • 2.26 MB
BOQ_998853.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .