| 1 | L1₹26.2 LAccepted-AOC H NO 154 VILLAGE SHIKARPUR PO NAJAFGARH NEW DELHI 110043 | WEST | DELHI | 110043 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹32.5 L+₹6.3 L (24.3%)Rejected-Finance 1 206 SHOP NO 71 MANDIR MARKET SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹32.7 L+₹6.5 L (24.9%)Rejected-Finance N A | NA | NA | 121004 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹35.4 L+₹9.3 L (35.5%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical As per NIT MOU not submitted |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
5 Jan 2021, 6:00 pmClosed
GE (East) Delhi Cantt-10
GE (East) Delhi Cantt-10
REPAIR TO ROOF TREATMENT OF CERTAIN BUILDINGS AT ZONE I AND ZONE II IN THE AREA OF AGE BR I UNDER GE (EAST) DELHI CANTT-10.
2020_MES_401702_1
GE/DE-51/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (East) Delhi Cantt-10
Class D Cat a i
9 documents required · 9 mandatory
₹500
GE (East) Delhi Cantt-10
₹97,000
Yes
22 Jan 2021
8 Dec 2020
7 Jan 2021
8 Dec 2020
5 Jan 2021
23 Dec 2020
8 Dec 2020 - 15 Dec 2020
Amount
Demolition of cement concrete in ground floor and pavings not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, complete all as specified and as directed.
Demolition of bricks (laid flat or on edge), brick tiles in f;loors, roofs, channels, kerbs, aprons etc., (each layer) laid, bedded and pointed in any mortar, complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, including racking out joints, hacking for key, scrubbing down with water etc., to receive new plaster, complete all as specified and as directed.
Dismantling scantlings 40Sqcm and over in section, fixed in any position, unframed work, complete all as specified and as directed.
Taking down PVC/CI rain water pipes (any size and pattern) including all fittings, head shoes, bends, swan necks, etc., and removal off the site, complete all as specified and as directed.
Taking up or down steel tubing and connections 20mm dia including cleaning for refixing and removal off the site, complete all as specified and as directed.
Dismantling existing water tanks of capacity exc 500 & not exceeding 1000 ltrs lowering from its position and removal to store, complete all as specified and as directed.
Excavation in post holes (or similar holes) in soft/loose soil each not exceeding 0.5 cum getting out, returning, filling in ramming earth or broken rubble in layers not exceeding 25 cm, watering and removing of surplus soil to a distance not exc 50m and making good surfaces, complete all as specified and as directed.
Cutting out cracks to V-section in existing roofs or terracing surfaces, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight), complete all as specified and as directed.
PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in roof kerb, mud stops etc., and similar type of works including weathering, slightly rounded or chamfered angles, complete all as specified and as directed.
PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in PCC padding/ base of OHT over roof, complete all as specified and as directed.
Brick work with sub class “B” bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar 1:6 using old size bricks, complete all as specified and as directed.
Brick work with sub class “B” bricks straight or curved on plan built to any radius in cement mortar 1:4 using old size bricks in half brick walls, complete all as specified and as directed.
40mm thick Brick tiles, laid flat on water proofing membrane, jointed and pointed in cement mortar 1:3 mixed with 5% crude oil by weight of cement, complete all as specified and as directed.
All as per description of Stl item No.- 15 here-in-before but except tiles, complete all as specified and as directed.
Cutting holes in brick walls not exc half brick, built in cement mortar for inserting hold fasts and making good disturbed prtion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 (using 20mm graded crushed stone aggregate), complete all as specified and as directed.
Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates to Fe-290 (Gde E- 165), complete all as specified and as directed.
Pre-Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws including dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings, fixed in repairs, complete all as specified and as directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified and as directed.
Preparing newly plastered surfaces of walls and applying two coats of cement based paint, complete all as specified and as directed.
Preparation of new steel surfaces and applying two coats of synthetic enamel paint on surfaces of any description exceeding 10 cm width or girth over a coat of red oxide, complete all as specified and as directed.
Rendering 10mm thick on concrete surfaces in cement mortar 1:4 mixed with water proofing compound finished even and smooth without using extra cement, complete all as specified and as directed. (Note : Water proofing compound shall be measured and separately).
Supply only liquid water proofing compound and mixed as per manufacturer's instructions, complete all as specified and as directed.
Wire brushing and cleaning top surface of tiles, cement concrete, including flashings and junction of parapets including taking out grass roots/vegetation etc., from existing roof surfaces and cleaning the surface after drying from dirt, mortar, dust mortar buds, algae and all other foreign matter and brushed and wiped, complete all as specified and as directed.
Applying evenly a tack coat of industrial bitumen 85/[email protected]/Sqm to the cleaned concrete surfaces (before laying APP and after laying APP under Srl item 27 here-under), complete all as specified and as directed.
Providing APP modified Polymeric five layered membrane with central core 100 micron high molecular high density polyethylene film. Minimum weight of membrane will be 3.6 Kg/Sqm. APP membrane will be laid across the slope from lowest line of roof towards ridge with over laps of 75mm in length side and 100mm on the width side of membrane bonded with hot blown bitumen. Over the APP membrane apply semi hot blown 85/25 penetration grade bitumen conforming to IS- 702 @ 1.2 Kg/Sqm and blinded with fine sand in dry condition @ 0.50Kg/Sqm dusted over the bitumen coat. Provide final layer of two coats of aluminium paint over a coat of primer as per manufacturer's instructions, complete all as specified and as directed.
NOTE:- a. (Applicable to Srl items No. 27 Here-in-above) At the time of uploading bids each tenderer shall upload a copy of MOU towards triparty agreement between tenderer, Manufacturer of Water Proofing Tretment from M/s Asian Paints lTD/M/s Sika India Pvt Ltd/M/s STP Ltd/M/s Fosroc Chemicals (India) Pvt Ltd. M/S Torchstar Membrane & Bitumen Products Pvt Ltd. only and their Applicators, for material and execution of work from any of the said manufacturers. Financial Bids of only those bidders shall be admitted whosoever shall uploads a legitimate MOU.
b. Terms of the MOU so entered between tenderes, Applicators and Manufacturers mentioned above shall also cover the warantee from manufacturer of Water Proofing Treatment for any defect in work executed by their applicator for a period of 10 Years. All other aspects with regard to payment, execution of work or other legal points shall be solely as decided between the tenderer, Water Proofing Tratment manufacturer & Applicator. Department shall in no way be responsible for any complicacy arising at a later stage between the parties to MOU with regard to payments or execution of work.
c. Stage for prepration of surfaces shall be approved from GE before applying the Water Proofing Treatment.
d. Material shall be procured from manufacturer and work shall be executed through authorised applicator. Engr-in-Charge shall ensure towards quality and quantity of consumption of materials at site as per manufacturer's instructions
e. The necessary equipment whatever required to execute the work shall be provided by the contractor and the cost of providing such equipments shall be deemed to be included in the quoted rates of the contractor and nothing extra shall be admissible on this account.
20mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs, complete all as specified and as directed.
PVC(SWR) pipes 110mm bore size single socketed, in any length with rubber ring joints,laid in trenches or in floors or walls including fixing clamps, complete all as specified and as directed.
PVC (SWR) bend of 110mm bore any radius, complete all as specified and as directed.
Rotational moulded polyethene three layers 1000 Litres capacity hoisted and fixed in position, 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed with pipe and fixed, complete all as specified and as directed.
20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball, screwed for iron pipe and fixed minimum weight -210gms, fixed in repairs, complete all as specified and as directed.
Gun metal globe or gate valve screwed down high pressure with iron wheel head, screwed both ends for iron pipe 20mm bore, fixed in repairs, complete all as specified and as directed.
Disconnecting existing tanks of capacity exceeding 500 Ltrs and not exceeding 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning etc., hoisting (if required),fixing in position and reconnecting, complete all as specified and as directed.
NOTE:- For minimum fair wages, other than Srl item No. 09, EPF and payment to labour employed, refer Sch A Note No-16,17 and Special Condition No 5 & 21.2 of this tender. Contractor must produce all the relevent record such as payment made to labour, EPF etc at the time of payment of RARs/Final bill. No payment will be released to contrator without producing the proper record.
NOTE:- Irrespective of whatever specified elsewhere in tender documents, all the debris/waste materials produced out of above mentioned work shall be removed out of Cantonement land and disposed off at locations notified by the Delhi Cantonment Board for disposal of waste building materials within NCR area, without any extra cost to Department under own arrangement of contractors. The rates quoted by the contractors against the items catered here-in-above in the BOQ are inclusive of said provision.
A R construction
MAA SANTOSHI ENTERPRISES
GAUTAM ELECTRIC WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .