Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 3 294 SURESH CHANDRA SHUKLA NYAYA MARG PRIMARY SCHOOL BHARWARA 1 GOMTI NAGAR GOMTI NAGA LUCKNOW UTTAR PRADESH 226028 | LUCKNOW | UTTAR PRADESH | 226028 | Admitted-Finance |
| 2 | DUCK CONSTRUCTION COMPANY Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹79.5 L
EMD Value
₹1.6 L
Closing Date
30 Mar 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGM EM
FCI RO Lucknow
Improvement of existing power supply and internal and External illumination with LED Lights at FSD Talkatora under DO Lucknow.
2023_FCI_745344_1
EM/20/2022-23
Open Tender
Electrical Works
Item Rate
120 days
talkatora
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.6 L
4 Jul 2023
16 Mar 2023
31 Mar 2023
16 Mar 2023
30 Mar 2023
16 Mar 2023
Amount
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required (Confirming to IS694-2010) as per direction of engineer in charge .
3x1.5sqmm
5x1.5sqmm
3x2.5sqmm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.(conforming to IS-9537 Part 3 ) 25 mm
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (conforming to IS 14772 (2000) ) 200mm x 150mm x 75 mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc as required.(conforming to IS 3854:1997 5/6 Amp Switch
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required conforming to relevant BIS/IS codes.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4way (4+12), Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and Neutral
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. (Confoming to relevent BIS/IS standard)
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 m X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (conforming to relevant BIS/IS codes)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (Confoming to relevant BIS/IS standard )
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35sqmm
35mm to 95mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kv grade as required.(conforming to IS 12943 (1990)
2 X 10 sqmm (19mm)
3.5 X 50 sqmm (35mm)
4 X 16 sqmm (28mm)
Erection of metallic pole of following length in cement concrete 1:3:6(1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required. Above 8.0 metre and upto 10.0metre
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.(conforming to IS-1239 part 1 (2004) )
Supply , Installation, Testing & Commissioning of integral well glass luminaire compressed of dia cast canopy gear box housing and glass driver surge with heat resistance glass of LED well glass fitting 35 to 40 watt, minimum 110 Lm/watt to 125 Lm/watt or Luminous should not be less than 4200, SPD with internal surge protection upto 4KV and External surge protection upto 10KV,Line voltage protection upto 8Hrs with autorestart having minimum 2 years warranty (Conforming to IP 65/IP66 protection and IS-16103-2012) as per direction of engineer in charge .
Supply , Installation, Testing & Commissioning of LED Street Light fitting with mandatory driver set having die cast aluminium body and lenses suitable for 45 watt with IP66 protection having Luminous 110 Lm/watt to 125Lm/Watt or Luminous should not be less than 4800 and having SPD with internal surge protection upto 4KV and External surge protection upto 10KV,Line voltage protection upto 8Hrs ,autorestart having minimum 2 years warranty (Conforming to IP 65/IP66 protection and IS-16103-2012) as per direction of engineer in charge .
Supply,Installation,testing & commissioning of LED Flood Light 100Watt made up of pressure die cast alumimium housing with toughened glass and high power LEDs and secondary lenses having Luminous minimum 110 Lm/watt or Luminous should not be less than 11000 and having SPD with internal surge protection upto 4KV and External surge protection upto 10KV,Line voltage protection upto 8Hrs ,autorestart having minimum 2 years warranty and Confoming to IP 65/IP66 protection and IS -16103-2012 as per direction of engineer-in- charge.
Supplying of 18 to 22 watt LED polycarbonate batten fixture with minimum 100 lumens/watt or Luminous should not be less than 2000 having minimum 2 years warranty (conforming to IS-16103 part 2 (2012)) as per direction of enginner in charge
Supply , Installation, Testing & Commissioning of loop in loop out box made of PVC sheet 200x 150x100 mm having suitable size 2 nos. terminals and 1 no. SP MCB 5A detachable gland plate, interconnection etc are required (Confoming to relevent BIS/IS standard )
Supply of PVC insulated PVC sheathed cable of 1.1KV grade armoured Underground aluminum conductor cable as reqd confirming to IS –7098 part I) of the following size as per direction of engineer in charge .
2x10 sqmm
4x16 sqmm
3.5x50 sqmm
S/I/T/C of weather proof 3 phase SMC MOULDED SERVICE CONNECTION BOARDS / Busbar box for AB Cables with pole mounting arrangement, with cable entry from bottom or sides and Busbar for high fault currents(Confoming to relevant BIS/IS standard )
Supply, installation, testing and commisioning of weather proof MS loop in loop out busbar box havin 4P MCCB 63Amp and of size not less than 450x350x200 mm with 4 Nos. suitable capacity ALU (upto 150 Amp) Bus Bar (R,Y,B & N) duly finished and painting, detachable gland plate & Arrangement for interconnection etc as required. (Confoming to relevent BIS/IS standard )
Supply of steel Tubular pole 8.5 to 9.00 mt 410/SP.-29(Confoming to IS 2713 (PART I TO III) : 1980
Dismantling and refixing of steel conduit along with all accessories in surface/recess including painting etc. in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Credit the following items
Aluminium Scrap ( i.e., Cables etc)(L.S.)
SUDEEP ELECTRICALS
M/S POOJA ELECTRICALS
AVADH KAARYA SOLUTIONS LLP
Saurabh Enterprises
DUCK CONSTRUCTION COMPANY
VASUDEV ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .