| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.9 L+₹1.4 L (30.8%)Rejected-Finance 3 100 2 KOTIAN CO NH66 KULAI POST SURATHKAL MANGALORE DAKSHINA KANNADA KARNATAKA 575019 | DAKSHINA KANNADA | KARNATAKA | 575019 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹6.5 L+₹2.0 L (43.9%)Rejected-AOC DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L3 | Rejected-AOC Being L3. Inadvertently selected Accept in Financial evaluation |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
22 Mar 2025, 6:00 pmClosed
Assistant Garrison Engineer (I) Mangalore
AGE (I) Mangalore Coast Guard Residential Area Kunjathbail-Post, Mangalore Karnataka-575015
REPAIR AND MAINTENANCE OF AC WATER COOLER AND WATER PURIFIER AT DHQ3 MANGALORE
2025_MES_699854_1
8004/24-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Assistant Garrison Engineer (I) Mangalore
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
₹10,000
Yes
4 Jul 2025
1 Mar 2025
29 Mar 2025
2 Mar 2025
22 Mar 2025
15 Mar 2025
Amount
M&L for servicing of split type AC unit of any capacity/ make by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor/ blower, by oiling, greasing, replacement of worn out rubber bushes of condensor motor, setting of grill alignment & knobs, Checking for any leakages, provision of thermocoal for air tightness, testing etc all as specified and directed.
M&L for Water wash servicing of split type AC unit of any capacity/ make for clogged air filter, noisy fans, gas leaking, leaking hoses etc of Indoor unit complete all as specified and as directed.
M&L for painting the outdoor unit of split AC of any capacity/any make and its stand by synthetic enamel spray paint as existing colour and writing MES No all as specified and directed.
M&L for Removing the unserviceable blower motor from the Split AC 1.5/2 Ton unit and M&L for rewinding of blower motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush of suitable size, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete.
M&L for Removing the unserviceable Blower motor from the Split AC 1.5/2 Ton unit and Supply and fix in replacement Blower motor suitable for Split type AC 1.5/2 Ton out door unit single ended or double ended shaft as per existing one. Make: AUE/ Marathon Electric or equivalent
M&L for Removing the unserviceable Blower from the Split AC 1.5/2 Ton unit and Supply and fix in replacement Blower suitable for Split type AC 1.5/2 Ton out door unit complete all as specified and as directed.
M&L for Removing the UNSV compressor from Split type AC and supply and fix new compressor suitable for 1.5 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/Mitsubhishi/Bluestar/Tecumseh or equivalent
M&L for Removing the UNSV compressor from Split type AC and supply and fix new compressor suitable for 2 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/Mitsubhishi/Bluestar/Tecumseh/Voltas or equivalent
S&F in replacemnt the copper piping (suction and discharge) and power cable including the thermal insulation all as directed by Engr in charge.
Supply and fix in repair Indoor cooling coil made up of copper tubing and copper/aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity split type AC all as specified and directed by engr in charge.
Supply and fix in repair condenser coil made up of copper tubing and copper/aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity split type AC all as specified and directed by engr in charge.
S&F in replacement Room sensor all as per existing one and suitable for 1.5/2 Ton capacity split AC Make : Bluestar/ LG
S&F in replacement Running capacitor 60 Mfd 440 V AC suitable for 1.5/2 Ton capacity AC Make : KELTRON/BHEL/KEL/TESLA/SYSCAP or equivalent
S&F in replacement of capacitor 6 Mfd 440 Volts suitable for condenser motor of 1.5/2 Ton A/C capacity Make : Ranutrol / Shriram/Usha/Keltron or equivalent
S&F in replacement coil sensor all as per existing one and suitable for 1.5/2 Ton capacity split AC M
S&F in replacement of condensor fan blade all as per existing one and suitable for 1.5/2 Ton capacity split AC
Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas charging (R-22/ R-32 / R-410 ) aprox 1 to 1.25 Kg or prussure as prescribed by manufacturer, leak testing & commissioning of Split type A/C of any type, any capacity, any make complete as directed by Engineer-in-Charge.
M&L for Repair/ replacement of Printed Circuit Board (PCB) complete including controlling unit all as per existing one suitable for Non inverter/ Normal type unit of 1.5 / 2 Ton A/C complete all as specified and as directed.
M&L for Repair/ replacement of Printed Circuit Board (PCB) complete including controlling unit all as per existing one suitable for Inverter Type Indoor unit of 1.5/2 Ton A/C .
M&L for Repair/ replacement of Printed Circuit Board (PCB) complete including controlling unit (ie Remote) all as per existing one suitable for Inverter Type Outdoor unit of 1.5/2 Ton A/C .
S&F in repair/ replacement of UNSV remote control of 1.5/2 TR AC of any make any type all as specified and as directed.
S&F in repair AC outdoor stand wall mounted for 1.5/2 TR split AC all as specified and as directed.
M&L for attending complaint for air conditioner/ water cooler/ Refrigerator at DHQ -3, Panambur, OTM Accn Panambur and CGRA Kunjathbail of defects such as Indoor unit water leakage, slow cooling of air conditioner, Noisy compressor, corrosion of wire and terminals, adjustment of PCB indicator, electrical control failure, clogged drain water pipe , water cooler tap leakage etc all as specified and as directed.
M&L for Removing the unserviceable condenser fan motor from the Water cooler/ refrigerator capacity and M&L for rewinding of condenser fan motor of capacity 1 HP 1350 RPM single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete all as specified and directed.
M&L for Removing unserviceable condenser fan motor from the water cooler/ refrigerator of any capacity and supply and fix in replacement new condenser fan motor 230 V, 50 HZ as per sample existing suitable for 40/120 Ltr capacity storage type water cooper. Make : Marathon Electric / AUE or equivalent
M&L for Removing the unserviceable compressor from water cooler and supply and fix new compressor suitable for 120 Ltr capacity of water cooler including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning of cooling coils necesary welding/ brazing and including required capillary tube complete all as specified and directed. Make : Kirloskar/Tecumshe or equivalent
M&L for Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas charging (R-134 A) aprox 0.75 Kg or prussure as prescribed by manufacturer, leak testing & commissioning for water cooler 40/120 Ltr storage capacity, any type, any make all complete as specified and directed by Engineer-in-Charge.
M&L for Servicing and cleaning of the water cooler/ refrigerator of any capacity any make by removing dust with suitable method, cleaning of water tank, inlet and outlets including leak proofing/ repairing of storage tank, necessary repairs to wiring of the water cooler unit (I.e) internal wiring connections to compressor, condenser motor etc., supply and replacement of damaged hinges, nuts, bolts, clamps, washers, screws, tightening of loose parts, servicing of condenser motor by oiling, greasing, required welding/bracing to the any part of the water cooler, repairs to chromium plated drain tray, replacement of worn out mounting rubber bushes of condenser motor/compressor, setting of thermostat, relay, knobs, checking for any leakages, scrap out rust and dust from body of water cooler complete all as directed by Engineer-in-Charge.
S&F in replacement starting and overload relay for 40/120 Ltr capacity water cooler including over load protector complete assembly Make : KIRLOSKAR,INDFOSS /USHA/BLUESTARor eqvlnt
S&F in replacement of running capacitor 36 Mfd, suitable for 120 Ltr capacity water cooler : Make : USHA/SRIRAM/KELTRON/Syscap or equivalent
S&F in replacement of running capacitor 10 Mfd, suitable for 40 Ltr capacity water cooler : Make : USHA/SRIRAM/KELTRON/Syscap or equivalent
S&F in replacement of chromium plated push/lifting cock, 15 mm, made up of brass and suitable for 40/80/120 Ltr capacity storage type water cooler as per existing sample. Make : JOHNSON/COSMA/ARK or equivalent
S&F in replacement of thermostat including knob, plate, screws suitable for 40/150 Ltr capacity water cooler. Make : USHA / Shriram / Blue star/Indfoss / Johnson/Ranutrol or equivalent
S&F in replacement of PVC drain pipe approx 1.5 Mtr Long of 25 mm dia for water cooler complete with clamp, screws etc complete to drain water from drain tray of water cooler as per existing sample
S&F in replacement of float valve with polythene PVC ball of 15 mm (1/2") bore size suitable for 40/120 Ltr capacity water coolers as per existing sample Make:Prayag
M&L for repair to voltage stabilizer of capacity 4/5 KVA of any type including checking the PCB control board,internal wiring,cutouts and rectify the defects all as directed.
M&L for Taking down old UNSV thermal insulation and Supply and fix and new thermal insulating puf for suction and discharge copper tubes of split type air conditioner of capacity upto 1.5/2.0 TR, neatly tying the ends with PVC insulation tape complete all as specified and directed.
M&L for Pumping down the AC, taking carefully the indoor and outdoor units of split AC along with voltage stablizer of capacity upto 1.5/2.0 TR by disconnecting all electrical connections, suction and discharge lines from its installed position and shifting to another location, making hole into brick/stone wall & filling back with white cement where directed and installing the indoor and outdoor units alongwith stablizer at specified location and connecting all the electrical, suction and discharge lines, topping up the gas as required and testing on completion for proper functioning complete all as specified and directed by Engineer-in-Charge. (Note: Gas, Copper tube, Insulation puff, Connecting wire as required additional shall be measured seperately under relevant item).
M&L for Taking down the corroded outdoor unit of split AC of any capacity, tinkering the corroded sheet metal parts, bottom base, angle iron frame, fan motor base plate, side covers, legs, door etc. with appropriate gauge MS sheet, angles by welding and brazing, renewal of nuts and bolts sheets metal screws, re-assembling, preparing the surface and painting with two coats of synthetic enamel paint over a coat of zinc chrome primer including renewal of door gasket where ever required and transportation all as specified and as directed.
S&F in replacement prefilter of water purifier . Make Aquaguard or equivalent
S&F in replacement of Carbon filter of water purifier , Make Aquagaurd or equivalent
S&F in replacement solenoid valve for water purifier. Make : Aquaguard or equivalent
S&F in replacement of printed circuit board for water purifier. Make : Aquaguard or equivalent
S&F in replacement of UV lamp for water purifier. Make : Aquaguard or equivalent
S&F in replacement of UV sensor for water purifier. Make : Aquaguard or equivalent
KOTIAN -ECC (BID ID -3268397)
KDR CONSTRUCTION (BID ID -3268484)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .