Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.4 LAccepted-AOC RAVI KIRAN MARKET JIWAJI CHOWK BADA LASHKAR GWALIOR M P 474001 | GWALIOR | GWALIOR | MADHYA PRADESH | 474001 | L1 | Accepted-AOC Being a lowest | |
| 2 | L2₹58.6 L+₹2.1 L (3.67%)Rejected-Finance | L2 | Rejected-Finance Not a lowest tender | |
| 3 | L3₹62.4 L+₹5.8 L (10.3%)Rejected-Finance | L3 | Rejected-Finance Not a lowest tender | |
| 4 | L4₹65.5 L+₹9.0 L (15.9%)Rejected-Finance | L4 | Rejected-Finance Not a lowest tender |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
18 Dec 2020, 6:00 pmClosed
CWE AF Gwalior
AF Station Gwalior
PROVISION OF AC PLANT AT AF STATION GWALIOR
2020_MES_377036_1
84088/E8
Open Tender
Miscellaneous Works
Lump-sum
540 days
AF Station Gwalior
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹1,000
GE AF Tech Area Gwalior
₹2.2 L
Yes
8 Feb 2021
12 Sept 2020
21 Dec 2020
12 Sept 2020
18 Dec 2020
4 Dec 2020
12 Sept 2020 - 30 Nov 2020
Amount
SCHEDULE A PART -I (BUILDING WORKS)
Construction of A C Plant room with permanent specification single story complete all as specified and shown in drawings.
Construction of AHU room with permanent specification single story complete all as specified and shown in drawings.
Sch A Part -II (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION" as listed in SCHEDULE ‘A’ PART- II .
Sch A Part -III (EXTERNAL ELECTRIFICATION & STANDBY POWER SUPPLY)
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION & STANDBY POWER SUPPLY", as listed in Sch ‘A’ Part- III .
Sch A Part- IV(ROAD,PATH &CULVERT)
Lump sum price worked out by the contractor for "ROAD,PATH & CULVERT", as listed in Sch ‘A’ Part-IV.
Sch A Part -V (AREA DRAINAGE)
Lump sum price worked out by the contractor for "AREA DRAINAGE,as listed in Sch ‘A’ Part- V.
Sch A Part -VI ( ADDITION /ALTERTION OF BLDG NO.P-1119)
Lump sum price worked out by the contractor for "ADDITION /ALTERATION OF BLDG NO.P-1119)",as listed in Sch ‘A’ Part- VI .
Sch A Part -VII ( DEMOLITION & DISMANTLING WORKS)
Lump sum price worked out by the contractor for "DEMOLITION & DISMANTLING WORKS",as listed in Sch ‘A’ Part- VII .
Sch A Part -VIII ( SITE CLEARANCE & DEVELOPMENT , EXCAVATION AND EARTH WORK)
Lump sum price worked out by the contractor for "SITE CLEARANCE & DEVELOPMENT , EXCAVATION AND EARTH WORK",as listed in Sch ‘A’ Part- VIII .
Sch A Part - IX (Miscellaneous Items of B & R and E & M)
S&F MCB SPN 6 to 32 A, 240V volt B curve breaking capacity 10 KA complete all as specified and directed.
S&F MCB SP 6-32 A, 240V volt B curve 10 KA complete all as specified and directed.
S&F ceiling fan, BEE 5 star rating,with down rod, fan connector/fan hook, 1200mm sweep, 240V AC with 3 Blade and connecting up including provn of three core PVC insulated multi stranded flexible copper conductor cable of size 1.5 sqmm copper wire from connector to fan of length not less than 0.5M complete all as specified and directed. Make – Usha/Crompton greave/Havells/Bajaj/Orient
Supply and fixing ultra slim square profile LED Tube light fitting, with extruded polycarbonate, environmental friendly, energy efficient 18 watt lumilinaire basic all purpose surface and wall mounted E-Lite LED pride plus tube light fitting 1 x 18 watt, 230 Volts, 1200mm including connecting to ceiling rose with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. Make- Havells Cat No - LHEXBLP7UN1W018 or equivalent approved make of Crompton /Philips/ Bajaj/Surya
S&F LED building security light fitting 35 watt new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and impact sesistance of IK07 with 10KV Built-in- Surge Protection Device with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. Make - Havells cat part No ENDURACITYLITEPLATPLUSSL35WLED757SASYBOPC or approved equivalent make CG/Philips/Bajaj.
S&F for 380mm sweep size ventilating fan with louvers heavy duty metallic body 1400RPM,AC, Single phase 230/240volts, including cutting/making opening of walls and making good the distrubed surfaces as per the existing internally and externally complete all as specified and as directed by the Engr-in-Charge. Make-Havells/Khaitan/Bajaj/Cromton Greaves.
S&F Sub main wiring using two runs of single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 2x 4 .0 Sq.mm of voltage rating 1100V & drawn in and including concealed PVC conduit of dia not less than 20mm with standard accessories, alongwith one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 1x4.0 Sq.mm as earth continuity conductor complete all as specified and directed. Note-Two runs of single core PVC cable 4.0 Sq.mm with one run of 4.0 Sq.mm as earth wire conductor and conduit shall be measured as one unit.
S & F factory made epoxy powder coated Distribution Board SPN 8 ways 240 Volt grade (SPN MCB DB) with double door ( IP-43 protection ) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with Knockouts complete all as specified and as directed.
M&L for preparation of newly plastered external surfaces of wall including cornices pilasters and apply two coats of exterior acrylic weather proof antifungal emulsion paint of approved brand and shade over a coat of 1.5 mm thick wall care puttyr as per manufacturers instructions including necessary scaffolding etc complete all as specified and directed.
S&F rubber gasket for fixing glass pane complete all as specified and directed
M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with preparation of plastered surfaces of existing external surfaces of walls and apply two coats of exterior acrylic weather proof antifungal emulsion paint of approved brand and shade over a coat of 1.5 mm thick wall care putty l as per manufacturers instructions including necessary scaffolding etc complete all as specified and directed.
S&F mild steel galvanised powder coated suspended false ceiling system with grid of size 605mm x 605mm, consisting of mild steel galvanised powder coated main runner of size 24mmx32mm and cross Tee of size 24mm x 27 mm and wall angle of size 22.2mmx22.2mm, suspended with 4 mm dia GI wire hanger at 1200 mm spacing, fixed with steel dash fasteners or from purlin of roofs with butterfly clips etc includding 12mm thick gypsum board ( Semi-perforted) in ceiling fixed to GI snap grid frame work with hold screws, of any height upto 8.5m with adjustable cleat of J hook including making provision for housing light fitting, AC grills etc complete including fixing, re-fixing false ceiling lights, wastage T&P as per manufacturer's instructions including preparation of new surfaces of gypsum board for false ceiling and applying two coats of oil emulsion distemper complete all as specified and directed.
Supply ,install,testing and commisioning copper wound step down distribution transformer of capacity 100 KVA In door type (ONAN) complete with standard fitting .HT ,11 KV,3 phase ,LT 433 volts ,3 phase, 4 wire with off load taping on primary side to vary secondery voltage at + 7.5% with taping at every 2.5%, type of winding : Delta/Star and Vector group : Dyn II all as per IS-1180 complete all as specified and directed comprising following accessories:- (i) Oil conserverter with filling hole and cap -01 No. (ii) Silica gel breather with initial charging -01 set (iii) Drain /sampling/filter valve with plug -01 No. (iv) Top filter valve with plug -01 No. (v) Explosion vent with diaphram -01 No. (vi) Thermometer 2 Nos, (vii) Rating and diaphragm plate 1 No. (viii) Earthing terminal 2Nos (ix) Additional neutral bushing for solid earthing 1 No. (x) Plain oil level guage 1 No. (xi) Lifting plug 2 Nos. (xii) Air release plug 2 Nos. (xiii) Bi directional rollers -04 Nos Note :- (i) The cost of PCC works for placing transformer on plinth is deemed to be included in the cost, the size of plinth should be as per the manufacturers instructionand as directed by Engr-in-charge.
Supply and installation of HT 11 KV, 3 phase, 50 Hz totally enclosed metal clad switchgear complete with Vacuum circuit breaker having rupturing capacity 250 MVA, the circuit shall comply with the requirements of the latest edition of IS: 13118/1991 or IEC-62271-100, The circuit breakers shall be with vaccum insulation medium and shall be indoor, floor mounted draw out type with overload and earth fault protection, ammeter, and of rating upto 400 Amp, 13 KA/3 Sec rated short time current, Motor operated manual operated closing method, Mannual emergency closing method, auxillary voltage for closing and tripping coils shall be 240 Volt DC, Auxillary voltage spring charging motor shall be 240 V, AC, 50 Hz with voltage variation +10% and -15% working at maximum ambient temperature 50 degree celcius alongwith set of CT's of ratio 10/5-5+5, class accuracy, 5VA burdens for metering and relay operation, with numerical relay for O/C + EF operation complete all as specified and directed Engr-in-charge. Note :- 1. The rate quoted by the contractor is deemed to be inclusive of any Adaptor panel required to connect with existing VCB panel. 2. The contractor shall obtain approval of detailed specification of VCB by GE before placing of order.
Design, fabrication, supply, install, testing and commissioning of factory made floor mounted LT cubical panel board in door type (double door) made out of 3.15mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opening and locking arrangement 415Volts, 3 phase, 50 Hz having Copper bus bar of capacity 400 Amps and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve hearing short circuit current with stand minimum 35 KA for one second complete connection from bus bar to breakers with suitable copper cable , panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc. The panel board shall be powder coated and red oxided primed :- (a) MCCB 4P, 200A, 36KA -01 No (b) The following items are provided in one compartment :- (i) Digital Voltmeter - 01 No (ii) Digital Ameter - 01 No (iii) Three Indiaction LED Lamp with warning - Set of 03
Supply, commissioning, erecting and testing complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set of capacity 100 KVA or next higher capacity, water cooled, 415 Volts (AC three phase, 4 Wire system of supply) 50 Hz at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Gwalior including PCC foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5 M height), anti-vibration pads complete all as specified and directed, including all features to comply with latest CPCB guidelines and comprising of followings:- (A) ENGINE (Prime Mover): Diesel Engine 1500 RPM, direct injection, multi cylinders, four stroke, confirming to IS:10000/ISO3046/BS:649/BS:5514 amended up to date, for continuous running capable of taking 10% overload for one hour in 12 Hour, water cooled, naturally turbo charged having adequate BHP to drive alternator 125 KVA or next higher capacity at outdoor atmostpheric conditions at Gwalior fitted with the following accessories subject to the design of manufacturer:
(i) Radiator cooling (ii) Radiator fan with guard (iii) Flywheel with starter ring (iv) Air cleaner oil bath type (v) Vacuum indicator (vi) Electronic governor class 1A (vii) Exhaust silencer (viii)Fuel filter & fuel hoses (ix) Fuel injection pump (FIP) (x) Fan & water pump assembly (xi) Lub oil filter & Pump (xii) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 12 volts 180 AH DC or as per manufacturers requirement including interconnecting cables/leads with terminals complete with starting/stopping switch, volt meter etc - 01 Set. (xiii) Engine safety shut down system against low lub oil pressure and high water pressure (xiv) Exhaust gas driven turbo charger (xv) Oil filter (xvi) Lub oil cooler (xvii) Engine maintenance manual with spare parts list (xviii) Suitably designed acoustic enclosure as per CPCB regulations.
(B) ENGINE INSTRUMENT PANEL digital type indicating the following:- (i) Starting switch on/off (ii) Water temp guage (iii) Hour meter cum RPM indicator (iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure (C)ALTERNATOR:- Alternator shall be self excited, self regulated, brushless for 100 KVA or next higher capacity continuous operation at the speed of 1500 RPM at 415 Volts, 50 Hz, Three Phase, 4 Wire system with advance electronic voltage regulator to ensure high voltage accuracy with +/-1% with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming to IS-13364 complete-01 No Note:- Alternator should be able to deliver output rating at actual site conditions. (D) Common fabricated base frame for engine and alternator made from structural channel leak proof PCC 1:2:4 mix, type B1 foundation including adequate number of suitable anti vibration pad all as per the recommendation of the manufacturer-01 Number (E) Bottom mounted (or as per manufacturer design) steel fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 12 Hour continous operation inside canopy with fuel level gauge, drain plug, locking arrangement etc with and including GI pipe connection duly laid as per Engineering practice complete.
Allied Agencies
M/s Kohli Builders
M/S LAKSHYA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .