Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹62.7 L
EMD Value
₹62,730
Closing Date
10 Jun 2024, 12:00 pmClosed
SE, EUDC-I, NOIDA
33/11 KV SUBSTATION, SECTOR-18 FIRST FLOOR, OPPOSITE SAB MALL, NOIDA
10 WORK IN HEAD SYSTEM STRENGTHENING AT DPR Sl NO 9 37 38 40 41 42 43 44 45 46 UNDER EUDD 7 NOIDA
2024_PVVNL_922604_1
121/EUDC-I/2023-24/NOIDA (WORKS)
Open Tender
Electrical Works
Item Rate
IN AREA OF EUDSD-II/XIII, NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
EE, EUDD-VII, NOIDA
₹62,730
17 Jun 2024
20 Apr 2024
10 Jun 2024
20 Apr 2024
10 Jun 2024
20 Apr 2024
Amount
Cartage of following material from ESC Noida/Sahibabad/ Ghaziabad /Any other ESC of Meerut Discom to JE Store and from JE store to various points site of work including loading and unloading at both ends : -
09 Mtr. ST Pole
11 Mtr. ST Pole
13 Mtr. ST Pole
LT XLPE cable Al. 1x400 Sq.mm.
LT XLPE cable Al. 3.5x240 Sq.mm.
LT XLPE cable Al. 3.5x70 Sq.mm.
11 KV XLPE cable Al. 3x185 Sq.mm.
11 KV Polymeric pin Insulator with pint
11 KV Polymeric Disc Insulator with fitting
ACSR Dog Conductor
11 KV X-Arm
Earthing Complete
O/D jointing Kit 3x185 Sq.mm. XLPE 11 KV
Providing & fixing of following material of standard make / best quality for complete the work of pole structure at HT / LT line as per RESPO norms by the contractor at his own cost : -
Stone pad 300x300x75mm.
Aluminium Lug.
Bolt, nut and washer.
MS clamp / Holding clamp with nut & bolts.
Dismantling of following item from various site of work and carriage from work site to J.E's store / central store including loading & unloading at both ends.
LT cable old & damaged
ACB old & damaged
ST Pole off size
ST Pole damage 13 Mtr.
ST Pole damage 9 Mtr.
ST Pole damage 11 Mtr.
Removal of conductor from both side spans of damaged pole and removal of H.T/L.T. line accessories from damaged pole.
Digging of pit of damaged pole in Pakka road (Hard soil) with the help of road cutter/digging machine, Tractor etc. for dismantling the pole.
Erection of S.T. pole 13 Mtr. including fitting of all reqired accessories of HT/LT line as per RESPO schedule.
Erection of S.T. pole 11 Mtr. including fitting of all reqired accessories of HT/LT line as per RESPO schedule.
Erection of S.T. pole 9 Mtr. including fitting of all reqired accessories of HT/LT line as per RESPO schedule.
Grouting of each pole (In ratio of 1:4:8 in Cement, sand and Brick Ballast) in size 450mmx450mmx1800 mm as per RESPO schedule Complete in all respects.
Construction of Plinth in size 450x450x300 mm of each (0.880 Cu.m) pole above the ground level (In ratio of 1:3:6 in Cement, sand and Brick Ballast) as per RESPO schedule Complete in all respects.
Excavation of earth and driving of M.S. earthing rod of size 20x2500 mm in earth and jointing through G.I wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts etc. as per RESPO schedule Complete in all respects.
Re-laying and resagging of conductor in both side spans of erected pole in H.T/L.T line.
Laying of 11 KV XLPE Cable 3x185 Sq.mm. through open cut method including road restoration Pakka & Kacha road complete in all respects.
Laying of LT Cable through open cut method including road restoration Pakka & Kacha road complete in all respects.
Laying of LT Cable from DTs to ACBs to LT line in different DTs complete in all respects.
Laying, Lifting and final Binding, Sagging of ACSR Dog Conductor including fixing of all accessories as per RESPO schedule Complete in all respects.
Fixing of 11 KV Outdoor jointing kit suitable for 11 KV 3x185 sq.mm. XLPE cable.
Providing and installation of LT ACB 630 Amp. with cabinet / structure (L&T, Schneider, ABB, Hevell's, PVVNL approved make) as per following specification with all relevant certificate :-
630 amp. 03 pole fixed manual ACB.
Red/yellow/blue light indication
ON & OFF Indication
Amp., Volt meter& energy meter digital
Metering C.T 630/5A,
Panel fabrication of size 1250mm x 900mm x 600 mm made of M.S sheet 14 gauge with powder coating with panel lock and key arrangement.(two nos). and additional locking arrangement seprately including providing hut type shape as per drg.
Fabrication of aluminium bus-bar for each phases
Incoming size 425 mm x 50mmx12 mm (twin)
Out going size 720 mm x 50mm x 12 mm(twin)
Neutral size 900mmx50mmx12 mm.
Fabrication of pannel stand made of M.S Angle of size 900mm x 600mm x 500 mm as per drg.
Assembly of above ACB, Indicators, Meters, Metering CT & bus bar arrangment in the panel, fitting the panel on Stand with nut and bolts with wiring etc. & grouting in ratio 1:4:8 with cement, coarse sand and brick blast.
Providing and fixing of aluminium bus bar of size 300mmx60mmx12 mm on L.T side of T/F.
Making all connections with ACB & Distribution T/F and commissioning the ACB complete in all respect.
PROVIDING AND INSTALLATION OF CHEMICAL EARTHING FOR ACB (WITH ALL MATERIAL AND LABOUR) AFTER INSTALLATION RESISTANCE SHOULD BE LESS THAN ONE OHM. AS PER FOLLOWING (The all material and labour shall be provided by the contractor with 12 month guarantee for resistance value less than one OHM.) :-
Providing of earth elctrode for chemical earthing Pipe in pipe type proper hot deep galvanization dia 50 mm length 3 mtr - 32mm x 6mm terminal connection hole dia 8mm The cavity between the pipe & pipe is filled with conductive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystalline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be galavanized the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested for ACB installed at 11/0.4 KV L.T. Substation.
Providing and fixing of GI strip of size 32 mm x 6 mm suitable for ACB installed at 11/0.4 KV L.T. Substation.
Providing and fixing of PVC Pit covers for above earthing electrode terminals.
Saraswati Electricals & Contractors
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .