Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹44.2 LAccepted-AOC | 1 | Accepted-AOC L-1 | |
| 2 | 2₹44.9 L+₹303.70 (<0.01%)Rejected-Finance 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹45.2 L+₹26,711.64 (0.59%)Rejected-Finance B 259 RAJAJI PURAM LUCKNOW 226017 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226017 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹46.0 L+₹1.1 L (2.44%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
23 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST LUCKNOW
GE EAST LUCKNOW
SPECIAL REPAIR TO BLDG. NO P-210 AND P-326 (JCO MD ACCN) OF 4 RAJPUT AND SPECIAL REPAIR TO BDY WALL OF HOUSE NO 217 MG ROAD UNDER GE (EAST) LUCKNOW
2022_MES_504011_1
GE/E/LKO/T-76 of 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE EAST LUCKNOW
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE EAST LUCKNOW
₹96,000
Yes
31 Mar 2022
27 Jan 2022
24 Feb 2022
27 Jan 2022
23 Feb 2022
10 Feb 2022
60 days
Amount
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in any position n.exc 15 cm thickness below and above ground level, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position as in roofs, floors (other than ground floors) and similar works complete all as specified and directed.
Excavation in trenches not exc1.5M wide and not exc 1.5M in depth for foundation etc and getting out in soft/ loose soil complete all as specified and as directed.
Returning filling including spreading, levelling, watering and well ramming in layers not exc. 25cm complete all as specified and directed.
Removing excavated material exc 1.50 Km but not exc 5.00 Km and depositing complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for brick work using old size fly ash brick, straight or curved on plan exc 6m mean radius, built in CM (1:6), complete all as specified and directed.
All as per item No 08 above but except bricks (Note:- Old bricks shall be used obtained from demolition)
M&L for brick work with old size fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4, complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5 graded stone aggregate) as in coping, bands, bed plates etc and similar works including necessary formwork complete all as specified and as directed.
M&L for 40mm thick PCC 1:2:4, type B-1 using 20mm graded crushed stone aggregae roof padding, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair face of brick work of walls, finished even & smooth without using extra cement, complete all as specified and directed.
M&L for rendering 10mm thick in cement plaster 1:4 on surfaces fair faces of brick work and surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair face of brick work of walls, mixed with water proofing compound (ISI marked) @ 2% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified and directed. (Note : - Water proofing compound shall be measured and paid separately as 'Supply only').
M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement, complete all as specified and directed.
Supply only integral water proofing compound, ISI Marked complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer, complete all as specified and directed.
M&L for complete removal of existing treatment of surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/ tint, complete all as specified and directed.
M&L for applying two coats of wall care putty on walls overall thickness 3mm and finished surface even and smooth, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint complete all as specified and directed.
Complete removal of existing treatment of wall & applying two coats of cement base paint of approved shade/tint complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling & applying three coats of white wash, complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of ceilling and applying one coat of white washing on ceilling complete all as specified and directed.
M&L for preparation of old previously treated surfaces of walls and applying one coat of white wash on walls complete all as specified and directed.
M&L for three coat of white wash on walls including complete removal of existing treatment complete all as specified and directed.
M&L for applying three coat of white wash including preparation new plaster surface on wall, complete all as specified and directed.
M&L for preparation of old decorated plastered surface of walls, and applying two coat of weather proof exterior emulsion paint of approved shade/tint on walls complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
S&F coloured non skid edge cut (joint free) ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exc 0.06 sqm but not exc 0.11 sqm, in floors etc set and jointed in white or coloured cement to match over and including 15mm thick screed in CM 1:4 complete all as specified and directed.
M&L for non skid coloured ceramic tiles, joint free 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exc 0.38 sqm in floors with borders, over and including 15mm thick screed bed in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floors complete all as specified and directed.
M&L for glazed ceramic tiles (coloured) 600x300x7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick rendering (as screed bed) in cement & sand mortar 1:4, complete all as specified and directed.
Dismantling of stone slabs and tiles laid in bedded cement mortar of any description or thickness in floors, aprons etc, complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over and including 15mm screed bed (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and including granite polish on Kota slab stonecomplete all as specified and directed.
All as per item No 35 above but except stone.
All as per item No 35 above but on vertical surface such as dado, skirting etc over and including 10 mm thick rendering in CM 1:4.
M&L for 50 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exc 3 M in length, Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3) complete all as specified and directed.
Forming construction joints 30 mm deep x 10mm wide filled with sealing compound grade "A" complete all as specified and directed.
M&L for 18-20 mm thick granite (of any type) work (table rubbed & polished) in steps, jambs, pillars, window-cills, cooking platforms & like, over and including 20mm thick screed bed in CM (1:4) including pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite, complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking plateform incl making hole for gas pipe and other similar situation complete all as specified and directed.
Suply and laying of 3mm thick (Minimum) polymeric water proofing membrane weighing not less than 3 Kgs/Sqm laid on a coat of bitumen primer @ 0.50 kg per Sqm for sunken treatment complete all as specified and directed.
Taking down loose filling of aggregate in any form from sunken slab and refiiling after treatment complete all as specified and directed.
Taking up or down steel water tubing and connections of 15mm bore, fixed in walls, ceiling, floors, trenches etc. complete all as specified and directed.
Taking up or down steel water tubing and connections of 20mm bore, fixed in walls, ceiling, floors, trenches etc. complete all as specified and directed.
M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing etc. and making good, cutting not exc 10 cm girth in brick walls complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Fixing only 15mm bore tubes "medium grade " galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. (Note:- Old pipe shall be used obtained from taking down)
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Fixing only 20mm bore tubes "medium grade " galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. (Note:- Old pipe shall be used obtained from taking down)
S&F in repair vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc including provision of PCC (1:5:10) type E2 in filling, making good to floor, complete all as specified and directed.
S&F in repairs PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified and directed.
S&F in repair vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified and directed.
S&F sink made of stainless steel 0.8mm thick for kitchen with plugs, washers and wastes, including fixing with cast iron cantilever brackets, bedding in cement mortar on to dwarf wall, connecting union to pipe, overall minimum size 600mm x 460 mm with bowl size 590mm x 430mm x160 mm including 40mm bore PVC waste fitting suitable for sink with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0, complete, including taking down old unserviceable sink complete all as specified and directed.
S&F for stainless steel kitchen plate rack of overall size 750 mm x 600 mm and 250 mm deep, with partitions for small/large plates etc made out of stainless steel 0.63 mm thick fixed with rawl plug and CP steel screws complete all as specified and directed. Make:- Blue Star (Silver shine), Diamond, Nirali, Prayag as approved by GE.
S&F CP grating 125mm dia with waste hole complete all as specified & directed.
S&F CP grating 125mm dia without waste hole complete all as specified & directed.
S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including CP brass nuts on both sides, complete all as specified & directed.
S&F in repair long body 15mm bore bib tap, fancy type, chromium plated, cast copper alloy, with capstan head, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F in repair CP angle valve, fancy type long body for 15 mm bore pipe with capstan head long screwed shank including CP cover plate complete all as specified and directed.
S&F in repair 15mm bore concealed type, stop valve cast copper alloy screwed down high pressure with capstan head and cup, screwed both ends for iron pipe or for union complete all as specified and directed.
S&F in repair 15mm bore pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and flynuts, screwed for iron pipes, complete all as specified and directed.
S&F for PVC corner shelf 300mm with chromium plated guard, fixed with brass screws and wooden/plastic cleats complete all as specified and directed.
S&F in repair CP brass tubular towel rail, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete all as specified and directed.
S&F 40mm bore PVC low density (LDPE) pipe of pressure 6kg/cm2 fixed to wall or laid in floor, complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125 mm size without swivel joint including fixing to steel pipe of 15mm bore or union complete all as specified and directed.
Dismantling RCC/PVC water tanks and removing from site capacity exc 250 litres & not exc 500 litres etc complete all as specified and directed.
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks, white colour, Triple layered (cylindrical, vertical with closed top) hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete, all as specified and directed.
S&F 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed.
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm bore, complete all as specified and directed.
S&F PVC coated 25mm dia Mild steel pipe as in curtain rods including brackets and fancy type end knobs, complete all as specified and directed.
Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm bore pipe drain pipes, set in cement mortar including PCC haunching and bedding, complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including PVC holding clamps, complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including PVC holding clamps, complete all as specified and directed.
S&F PVC (SWR) floor trap of size 75/110mm, complete all as specified and directed.
S&F for 110mm PVC (SWR) WC connector bent type, complete all as specified and directed.
S&F 110mm bore PVC (SWR) bend, any radius, complete all as specified and directed.
S&F 75mm bore PVC (SWR) bend, any radius with access door, complete all as specified and directed.
S&F 75mm bore PVC (SWR) bend, any radius, complete all as specified and directed.
S&F 110mm bore PVC (SWR) vent cowl, complete all as specified and directed.
Taking down chowkhat with shutter (without taking off shutter from the frame) and area exc 1.5 sqm but not exc 4 sqm each, complete all as specified & directed.
Taking down chowkhat with shutter (without taking off shutter from the frame) and area not exc 1.5 sqm each, complete all as specified & directed.
Taking down shutter of any description exc 1 Sqm and not exc 2 Sqm each and refixing in same opening including easing and adjusting of shutter as required including renewal of unserviceable screws complete all as specified and directed.
Taking down shutters of any description not exc 1.0 sqm each complete all as specified and directed.
S&F 2nd class hard wood plain, solid, straight chawkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F mild steel holdfast, hook and pintle hinges, large hasp and staples, clamps, hooks for hanging fans and similar small articles conforming to Grade E-165 (Fe 290) including necessary welding etc complete all as specified and directed.
M&L for plain cement concrete cast in situ 1:3:6 type C1 using 20 mm graded stone aggregate as in copings, hold fast, back filling of pressed steel frame and other similar work water troughs and the like including weathering, slightly rounded or chamfered angles and throating etc including form work complete all as spcefied and directed
S&F pressed steel frame for door with one or more rebates size 125x60mm including necessary fixing lugs, lock striking plates, hinges, hold fast etc. complete all as spcefied and directed
S&F pressed steel frame for door with one or more rebates size 105x60mm including necessary fixing lugs, lock striking plates, hinges, hold fast, etc. complete all as spcefied and directed
S&F for 30mm thick factory made flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides, complete all as spcefied and directed .
S&F for 35mm thick factory made glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24 (a) of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & directed.
S&F in repair framed work as in cupboards, gates angle, sheet or other section etc (Fe-410-W Gde-250) complete all as specified and directed.
M&L for in repair block board, 19/20mm thick, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame work as in cup board shutter/shelves/cabinet etc, complete all as specified and directed.
M&L for 0.90mm thick decorative laminates 'Mica type 1 of surface finished,colour and pattern as approved, fixed with adhesive as per makers instructions complete, all as specified and directed.
S&F in repair kitchen cabinet shutter with frame including shelves, drawer made of solid PVC Block board18/19 mm thick one side decorative face having smooth outlet integral skin are made and shall be fixed to walls using required size sheet metal screw and solvent adhesive vertical and horizontal profile made of PVC 18/19mm solid board profile complete all as specified by manufacturer instruction complete, all as specified and directed.
M&L for external teak wood lipping, 6mm thick fixed with nail, complete all as specified and directed.
M&L for magnet ball catcher for cup board shutters, complete all as spcefied and directed.
S&F for clip type stainless steel self closing hinges for cabinets fitted with cadmium coated screws complete all as specified and directed.
M&L for 100mm size stainless steel fancy type handle, complete all as specified and directed.
S&F for 100 mm long Hasp & staple, safety type, Stainless steel with mild steel hinges pin including bolt to hinges plate & fixed with screw, complete all as specified and directed.
S&F PVC solid door frame of size 50x47mm made out of 5m plain coloured sheet reinforced with MS square tube & with wood grain printed complete all as specified and directed.
S&F for factory made soild PVC profiled panel door shutter 28mm thick with integral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill, with 'C type Gl or 40 x 20 x19 of MS pipe as stiffner & supplying & fixing in frame at site as per pecifications & drawing complete all as specified and directed.
S&F butt hinges of size 100 mm medium weight, stainless steel ISI marked complete all as specified and directed.
S&F aluminium handle, 150mm size, cast type, anodized (ISI marked) complete all as specified and directed.
S&F 200 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed.
S&F 300 mm long mild steel sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S&F mild steel helical door spring 300mm ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and directed.
S&F small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, articles of 2nd class hardwood, articles not exc 200 cucm each complete all as specified and directed.
Dismantling of steel windows/ventilators withot taking off shutters, complete all as specified and directed.
S&F for powder coated aluminium glazed window shutter sliding type using 1.80 mm thick aluminium open three track section having size of style & top rails 83x44mm, bottom rails 100x44mm including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading screws, anodised aluminium fittings complete and including glazing by using 5mm thick plain sheet glass and stainless steel wire mess of dia 0.36mm and aperture 1.4mm, complete all as specified and as directed. (Note- Cost of glass thickness not less than 5.00 MM and SS wiremesh as approved by GE is also included in quoted rates)
S&F for powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F for powder coated aluminium grill (opening of grill not more than 100x100mm) fixed to windows or ventilators with anodised aluminium U channel 25x12mm size complete all as specified and directed.
S&F for powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified.
S&F for powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 No.) complete all as specified and directed.
S&F mild steel work as in fencing posts including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work complete all as specified and directed.
S&F mild steel framed work such as grills, guard bars, barred iron doors, cooler stand, framework of water tanks and similar works, conforming to Grade E-165 (Fe 290), including welding etc. complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire, staples complete all as specified and directed.
S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire, staples complete all as specified and directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of red oxide complete all as specified and direced.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified and directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L for cement concrete (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in surface channels, drains, coping and benching including necessary formwork whrever required complete all as specified and directed. (Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately).
Dismantling of stone slabs and tiles laid in dry of any description or thickness in floors, aprons etc complete all as specified and directed.
M&L for 60mm thick pressed precast concrete interlocking paver block reflective type, rubber moulded coloured of M-35mm grade over and incliding 25 mm thick sand cushion as in floors complete all as specified and directed.
All as per item No 127 but excet paver block. (Note:- Old paver block shall be used obtained from dismantling).
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed
M&L for providing precast cement concrete type B-O using 12.50 mm graded stone aggregate louvres and jallies set in CM 1:4, 35mm thick (measured solid), including all mouldings but excluding frame complete all as specifed and directed.
M&L for precast RCC 1:2:4 type B-0 using 20mm graded stone aggregate as in Chhajjas, cover slab, shelves and similar articles set in CM 1:4 complete all as specified and directed. (Note:- Reinforcement shall be measured & paid separately).
M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking and binding with Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as spcefied and directed.
Excavating in post holes in soft/loose soil (or similar holes) each not exc 0.5 cum getting out, returing, filling in and ramming earth or broken ruble mixed with earth around, in layers not exc 25 cm , watering, and removing surplus soil to a distance not exc 50 M and making good surface complete all as spcefied and directed.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate in foundation, filling & mass concrete complete all as spcefied and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete drilled for fixing of steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing confirming to Fe 410-W (Gde-E- 250) quality complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type of standerd, rails, straining bolts etc including provision of binding wire complete all as spcefied and directed.
Supply only 3 mm dia galvanised chain link fencing, 75mmx75mm complete all as specified and directed.
S&F galvanized 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc complete all as specified and directed.
S&F 150 mm dia reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
M&L for concrete bed to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 complete all as specified and directed.
M&L for cement concrete type C2 1:4:8 (40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed
Dismantling of Trellis work (Jafri)/RCC jali complete all as specified and directed
M&L for mild steel screw 5 to 10 mm dia of bolts (machine made) with haxagonal or square heads at one end and screwed the other,or screwed bolt ends, each screwed and to be fitted with washers and one hexagonal or square nut, length of bolts exc 5 cm and not exc 10 cm long complete all as spcefied and directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per serial item No 146 here-in-before but one bell point controlled by one bell push, 06 Amp.
All as per serial item No 146 here-in-before but one, two way light point controlled by two, two way switches, 06 Amp.
All as per serial item No 146 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.
All as per serial item No 146 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.
All as per serial Item No 146 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board.
S&F switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
S&F switch piano flush type, 06 Amp, single pole, two way, 230 volt complete all as specified & directed.
S&F bell push, flush type, 06 Amp, 230 volt complete all as specified & directed.
S&F socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete all as specified & directed.
S&F switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete all as specified & directed.
S&F ding dong bell, AC, 230 volt, single pole complete all as specified & directed.
S&F electronic ceiling fan regulator with rotary step, two module, humfree, AC, 240 volt, 100 Watt and duly ISI marked complete all as specified & directed.
S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed.
S&F in replacement of decorative wall mounting type LED light fitting, 1 x 15 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 9/10 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed. Make:-Philips, Cat No : 30575 (Comet) Havells, Cat No : LHDL06160099 (CITY 3) as approved by GE.
S&F in replacement of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed. Make : Crompton, Cat No : LBHE-10-CDL Havells, Cat No : RUGBYNEONFT10WLED760SSYMBOPC, or PHILIPS Cat no WT202WLED6SCWPSUS2PC as approved by GE.
S&F in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into and including LED tube light fixture of four feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed. Make : Crompton, Cat No : IGP131LT8-16& LT8-20-865-2 or Havells, Cat No : REGALBATTENT8UPT01X22WSSBS & PHOTONULTRA1213T8SSTL20WLED865SPC, or Philips Cat no TMC 501P1XT-LED22W P 3241 as approved by GE.
S&F in replacement of single side connection LED T8 tube light rod 8 Watt, 6500K of two feet long into and including LED tube light fixture of two feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed. Make : Crompton, Cat No : DMLN1LT8-8& LT8-8-865-2 or equivalent in havells / Philips as approved by GE.
S&F LED wall/surface mounted down lighter, 12 W including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified. Make:- Crompton Model-LCDSPLN-R12-CDL or equivalent in Havells/Philips/Bajaj as approved by GE.
S&F ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Taking down carefully ceiling fan of any sweep complete with all accessories, dismantling blades and deposit in safe custody of AGE E/M Yard-II for BER procedure complete all as specified & directed.
Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
S&F in replacement of industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. Make: - Legrand, Cat No. 5078 11 & 4085 93, or Hager, Cat No : VYA120C & NCN120N or Schneider, Cat No : A9HMS220 & A9N1P20C as approved by GE.
S&F door, single pole and neutral, AC, 240 volt, 08 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. Make :-Legrand, Cat No. 5076 11 & 5079 13 or Hager, Cat No : VYS08D & VYS08E or Schneider, Cat No : A9HSND08 & A9HSND08WB as approved by GE.
S&F in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed Make :-Legrand, Cat No. 5077 50 & 5079 38, Hager, Cat No : VYV04PM & VYV00E or Schneider, Cat No : A9HVD04M & A9HVDXXWB and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. Make :-Legrand, Model : DPX 160, Cat No. 4200 16, Hager, Cat No : HDA126Z or Schneider, Cat No : LV516312 (b) MCB, SP, AC, 240 volt of 06 to 32 Amp, "C" curve, 10 KA breaking capacity - 12 Nos. Make :-Legrand, Cat No. 4085 87 to 4085 95, Hager, Cat No. NCN106N to NCN132N or Schneider, Cat No. A9N1P06C to A9N1P32C
S&F in replacement of MCB, SP, AC, 240 volt of 06 to 40 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make :-Legrand, Cat No. 4085 87 to 4085 95 or Hager, Cat No : NCN106N to NCN132N or Schneider, Cat No : A9N1P06C to A9N1P32C as approved by GE.
S&F in replacement of MCB, DP, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make :-Legrand, Cat No. 4086 36 or Hager, Cat No : NCN232N or Schneider, Cat No : A9N2P32C as approved by GE.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
S&F ceiling fan of 1200 mm sweep,230V,350-370 RPM, with air delivery of 215 cmm or more with BEE STAR RATED including provn of fan hook made of MS of required size and shape,hanging with the help of down rod upto 04 feet and connecting with provn of 3 core copper cable of size 1.5 sqmm from ceiling rose to fan complete all as specified and directed. Make:-Khaitan/Havells/Crompton/Bajaj/Usha
S&F exhaust fans single phase 230/240 volts heavy duty metalicbody of size 300 mm sweep 1400 RPM ISI marked, and making connection with twisted copper flexibelwire 23/0.076 mm complete all as specified and directed. Make/Model:- Havells Turbo Force SP / Almonard 300 mm Heavy Duty/Usha Turbo Heavy Duty
S&F exhaust fans, plastic body, AC, single phase, 230/240 v of size 200 mm sweep with louver and making connection with twisted copper flexible wire 23/0.076mm all as specified and directed. Make:- Havells / Almonard /Usha as approved by GE.
Cutting walls any type, making holes for fixing of exhaust fan of any size or sweep and making good surface with fine plastering, finishing and colouring with existing colour matching complete all as specified and directed
Taking down electric meter and refixing on same board after rewiring complete all as specified and directed.
S&F LED bulb 9/10 Watts suitable for B22 white in colour all as specified and directed. Make:- Havells/ Crompton/Bajaj
M/S KAUSHIK CONSTRUCTION
M/s Rathore Traders
M/s Bhadoria Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .