Loading…
Loading…
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
6 Jun 2026, 6:00 pmDue today
GE (AF) Hakimpet
Secunderabad
REPAIRS AND MAINTENANCE OF INTERNAL ELECTRIFICATION INCLUDING EARTHING AT MD ACCN AREA AT AFS HAKIMPET UNDER GE (AF) HAKIMPET
2026_MES_765846_1
8946/E8
Open Tender
Electrical and Maintenance Works
270 days
Hakimpet
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Hakimpet
₹66,000
Yes
16 May 2026
16 May 2026
8 Jun 2026
16 May 2026
6 Jun 2026
30 May 2026
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fittings etc removing materials and making good disturbed surfaces of walls, floors etc. including paint touch up to match with the existing surface as per site requirement complete all as specified and directed by Engr-in-Charge.
Taking down existing unserviceable MCCB/main switch (any type and capacity) and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge.
Taking down existing unserviceable distribution board with MCBs, switch fuse unit, enclosure and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge.
Taking down Existing old unserviceable submain wiring of any description /type size and removal of UNSV material from site and making good the disturbed surface of walls / ceiling so as to match with the existing finishes all as specified and as directed by the Engineer -in- charge .
a) One light point controlled by one, 1 way switch
b) One 3 pin 6 Amps socket point controlled by one switch on same board
c) One 3 pin 6 Amps socket point controlled by one switch on independent board
d) One ceiling fan/exhaust fan point controlled by one 1way switch
e) One bell point controlled by one switch
f) One light point controlled by two two way switches
All as per item No. 5 here-in-before but with 2.5 Sqmm for 3 pin 6 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
All as per item No. 5 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5 sq.mm FRLSH insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through existing PVC conduit/casing capping of suitable size but not less than 20 mm dia on surface of stone/concrete wall /roof etc all as per site requirement including FRLSH,PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made out of 1.6 mm thick MS sheet with sink into the wall for mounting including laminated sheet cover 3mm thick laminated hylam sheet fixed with cadmium plated screws/PVC gang box fully enclosed type for mounting switches,sockets,fan regulator, etc including all accessories and making good the disturbed surfaces of walls and paint touch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge.
a) One light point controlled by one, 1 way switch
b) One 3 pin 6 Amps socket point controlled by one switch on same board
c) One 3 pin 6 Amps socket point controlled by one switch on independent board
d) One ceiling fan/exhaust fan point controlled by one 1way switch
e) One bell point controlled by one switch
All as per item No. 8 here-in-before but with 2.5 Sqmm for 3 pin 6 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
All as per item No. 8 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
a) One light point controlled by one, 1 way switch
b) One 3 pin 6 Amps socket point controlled by one switch on same board
c) One 3 pin 6 Amps socket point controlled by one switch on independent board
d) One ceiling fan/exhaust fan point controlled by one 1way switch
e) One bell point controlled by one switch
f) One light point controlled by two two way switches
All as per item No. 11 here-in-before but with 2.5 Sqmm for 3 pin 6 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
All as per item No. 11 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5 sq.mm FRLSH insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through existing concealed PVC conduit upto 32mm including FRLSH, PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made out of 1.6 mm thick MS sheet box with 3mm thick laminated hylam sheet fixed with cadmium plated screws for mounting switches, sockets, fan regulator, etc including all accesories if required making good the disturbed surfaces of walls and paint tuch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge.
a) One light point controlled by one switch
b) One 3 pin 6 Amps socket point controlled by one switch on same board
c) One 3 pin 6 Amps socket point controlled by one switch on independent board
d) One ceiling fan point controlled by one switch and regulator
e) One bell point controlled by one switch
All as per item No. 14 here-in-before but with 2.5 Sqmm for 3 pin 6 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
All as per item No. 14 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
Supply and laying Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed by the Engineer-in-charge.
Supply and laying casing capping , 1.2 mm thick minimum, 20mm width minimum with double locking arrangement including all accessories and hardware complete all as specified and directed by the Engineer-in-charge.
Supply only electrical flexible conduit 25mm dia, dark grey/white, corrugated , standard length of 25m all as specified and directed by Engineer-in-charge
S&F of ceiling rose 6 A, 3 plate,PVC/polycarbonate ,insulated body 240 Volt , 50 Hz all as specified and as directed.
S&F of switch piano flush type, single pole one way 6 Amps 240 volts ISI marked complete all as specified and as directed.
S&F of bell push,flush type, 6 Amps ,240 Volts ISI marked complete.
S&F of switch socket combination 2 in 1, 3 pin 6 Amps, flush type, universal ,240 volts complete all as specified and as directed
M & L of switch socket combination 2 in 1, 3 pin , 6 Amps/16 Amps, flush type,universal,240 volts complete all as specified and as directed
S&F 5A Switch Socket Combined with Box Constructed with flame-retardant (FR) grade engineering plastic complete all as specified and as directed
S&F 16A Switch Socket Combined with Box Constructed with flame-retardant (FR) grade engineering plastic complete all as specified and as directed
S&F of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz 2 module size in 5 steps flush type complete all as specified and directed.
S&F of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz single module size in 5 steps flush type complete all as specified and directed.
S&F of switch Modular type single pole one way 6 Amps 240 volts complete all as specified and as directed.
S&F of switch Modular type single pole one way 16 Amps 240 volts complete all as specified and as directed.
S&F of bell push,modular type, 6 Amps ,240 Volts ISI marked complete.
S&F of socket 2 in 1, 3 pin 6 Amps, modular type, universal ,240 volts complete all as specified and as directed
S&F of socket 2 in 1, 3 pin 16 Amps, modular type, universal ,240 volts complete all as specified and as directed
S&F of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz 2 module size in 5 steps modular type complete all as specified and directed.
S&F Anchor roma USB charging port 1000 ma 5v 1m 20460 complete all as specified and directed by the Engineer-in-charge.
S & F in replacement of batten/angle holder, PVC/Polycarbonate type with back plate, 240 V , 50 Hz suitable for batten fittings complete all as specified and directed.
Supply and fix 12W LED globe shape bulbs, cool day white, energy efficient, no visible flickering, glare reduction technology complete all as specified and directed
M & L of Call bell, ding dong, AC 240 Volts complete all as specified and as directed
S&F surface plastic boxes made of high impact plastics and metal thread inserts 3Module complete on any surface all as specified and directed by the Engineer-in-charge
All as per item here-in-before but with 4Module complete
All as per item here-in-before but with 6Module complete
All as per item here-in-before but with 8Module complete
All as per item here-in-before but with 12Module complete
Supply and fixing of modular cover plate white with frame complete for 3 module complete all as specified and directed by Engr-in-charge.
Supply and fixing of modular cover plate white with frame complete for 4 module complete all as specified and directed by Engr-in-charge.
Supply and fixing of modular cover plate white with frame complete for 8 module complete all as specified and directed by Engr-in-charge.
Supply and fixing of modular cover plate white with frame complete for 12 module complete all as specified and directed by Engr-in-charge.
M&L for submain wiring along with earth wire with 3 x 4.0 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through existing PVC Conduit in wall/roof surfaces complete all as specified and directed by Engineer-in-Charge. Note: Two runs of 4.0 Sqmm copper cable and 1 run of copper earth wire shall be measured as one unit length.
All as per item No. 48 here-in-before but with 3 x 6.0 sqmm FRLSH PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge. Note: Two runs of 6.0 Sqmm copper cable and 1 run of copper earth wire shall be measured as one unit length.
All as per item No. 48 here-in-before but with 5 x 6.0 sqmm FRLSH PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge. Note: Four runs of 6.0 Sqmm copper cable and 1 run of copper earth wire shall be measured as one unit length.
All as per item No. 48 here-in-before but with 5 x 10.0 sqmm FRLSH PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge. Note: Four runs of 10.0 Sqmm copper cable and 1 run of copper earth wire shall be measured as one unit length.
M&L for submain wiring alongwith earth wire with 3 x 4.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC casing capping in surface/recessed and its all accessories of suitable size complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 4.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length.
All as per item No. 52 here-in-before but with 3 x 6.0 sqmm FRLSH PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge. Note: Two runs of 6.0 Sqmm copper cable, 1 run of copper earth wire and one run of PVC conduit shall be measured as one unit length.
All as per item No. 52 here-in-before but with 5 x 6.0 sqmm FRLSH PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge. Note: Four runs of 6.0 Sqmm copper cable, 1 run of copper earth wire and one run of PVC conduit shall be measured as one unit length.
All as per item No. 52 here-in-before but with 5 x 10.0 sqmm FRLSH PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge. Note: Four runs of 10.0 Sqmm copper cable and 1 run of copper earth wire shall be measured as one unit length.
Supply and fix distribution board double door type TPN 4 way sheet steel powder painted with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge.
Supply and fix distribution board double door type VTPN 4 way sheet steel powder painted with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB distribution board single door type SPN 12 way sheet steel powder painted with bus bar ,neutral link & earth bar etc.with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing circuit complete all as specified and directed by Engineer-in-Charge.
All as per item No. 58 above but of SPN 8 way.
All as per item No. 58 above but of SPN 4 way.
Supply and fix sheet metal powder painted double pole enclosure with a two pin and earth plug and socket flushing in wall including 20 Amps rated double pole MCB 10 KA, "C" curve complete all as specified and directed by Engineer-in-Charge.
S&F 16 Amp 30mA PRCD Adaptor (White) - Plastic Body, Auto-Trip Safety for Appliances - Smart and Enhanced Protection Against Electrical Shock as Per IEC 61540 Guidelines all as specified and directed by the Engineer-in-charge.
Supply and fix MCB, SPN, 40-63 Amps, 240 Volts
Supply and fix MCB , SP, 6 - 32 Amps, 240 Volts
S&F MCB Triple pole and Neutral (TPN) of capacity 40-100 Amps 415 volts ,breaking capacity 10 KA,'C' series ,fixed in proper position all as directed by the Engineer in charge .
Supply and fixing MCCB 125 Amp three pole 415 Volt , breaking capacity 16 KA, with fixed thermal & magnetic setting complete all as specified and as directed by the Engineer in charge.
Supply and fixing MCCB 25-100 Amp Three pole 415 Volt , breaking capacity, 16 KA, with fixed thermal & magnetic setting complete all as specified and as directed by the Engineer in charge.
S&F 30mA 16A Double Pole RCCB Circuit Breaker, AC Type, PVC Base, DIN rail mountable design complete all as specified and directed by the Engineer-in-charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, luminous efficiency > 100 lm/watt, surge protection upto 4kV, 440V High voltage protection, power factor > 0.95, CRI > 80 including all accessories and fixing arrangement for fixing the light fitting to walls / roof surface all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F in replacement LED light fitting in replacement of 10 watt bulk head luminaries complete with all accessories and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing in replacement Deep recessed downlights, 18Watt, aluminium construction EMC/EMI compliant, Ripple<5% flicker free driver, including connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light to roof surface all as specified and directed. Model No. Havells VIBEFLRDDLR18WLED840S or similar
Supply and fixing in replacement Deep recessed downlights, 12Watt, aluminium construction EMC/EMI compliant, Ripple<5% flicker free driver, including connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light to roof surface all as specified and directed. Model No. Havells VIBEFLRDDLR12WLED840S or equivalent in Bajaj, Crompton Greaves or Seimens.
Supply and fixing in replacement surface downlights, 18Watt, aluminium housing with heat sink including connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light to roof surface all as specified and directed. Model No. Havells INTEGRANXTRDDLRSURD18WLED840S or equivalent in Bajaj, Crompton Greaves or Seimens.
Disconnecting ceiling fans of any sweep and from any height including electrical connections, bringing down, dismantling, opening up, cleaning internally and externally, overhauling by replacing unserviceable items such as split pins, bearings, bushes, copper flexible cord, cotter pins and check nuts etc, lubrication with approved lubricants, reassembling including replacement of worn-out /defective parts and refixing for smooth functioning and connecting cable from ceiling rose to fan including testing complete all as specified and directed by the Engineer-in-charge.
Description all as per Ser item No.75 above here before but exhaust fan /wall mounting fan/Pedestal fan of sweep 230/300/375/450 mm complete all as specified and as directed by the Engineer-in charge.
Notes for item No 75 & 76:- Replacement of unserviceable spare part required for servicing/overhaulingand rewinding of fans shall be measured and paid separately under relevent items after testing and commissioning vide relevent Item of this schedule.
Supply only the following parts in replacement of Ceiling/ Exhaust Fans of existing makes and size complete all as specified and as directed by the Engineer-in Chargre :-
(a) Capacitor 2.5 mfd capacity 240 volts. (Make ) : CAPCO/TIBCON
(d) Copper flexible cord 3 core of size 23/00076, 5m bundle
(g) Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. (M & L)
S & F in replacement of single phase motor for plastic exhaust fan, pure copper winding, high quality double ball bearings suitable for any size and type complete all as specified and directed by the Engineer-in-Charge.
S & F in replacement of iron and aluminium louvers with suitable frame work and fixing arrangements for exhaust fan of 300mm sweep complete including removing the existing unserviceable one complete all as specified and as directed.
S & F in replacement of louvers with suitable frame work and fixing arrangements, 3 aluminum flaps with powder-coated Tata CRCA steel frame, Weather & Pest Guard for exhaust fan of 250mm sweep complete including removing the existing unserviceable one complete all as specified and as directed.
S & F in replacement of aluminium frame and SS mesh Grade 304 mosquito net ivory colour with stopper and screws suitable for exhaust fan of any size all as specified and directed by the Engineer-in-Charge.
Taking Down water heater (Electric Geyser) storage type of any make of 25 / 50 ltr capacity after disconnecting the existing electrical connection, water pipes and reassembling in all respects after replacing unserviceable parts/components and testing for proper working after repairs and refixing in the original place/position duly connecting up water supply and electric supply etc.complete all as specified and as directed by the Engineer-in-Charge.
Note :- Spare parts replaced shall be measured and paid separately under relevent items below. However labour cost of replacement is deemed to be included in the rate quoted.
Supply and fixing the following parts in replacement of water heater (Electric Geyser) storage type of given make and size complete all as specified and as directed by the Engineer-in Chargre :-
(a) Thermostat ISI marked suitable for 25/50 litre capacity . Make -bajaj/Airex/Cotherm/Expo/Secure/Girish/Racold
(b) Heating element ISI marked, Material Incoloy 2000 watt push/thread type circular /triangular base, suitable for any make and size. Make -bajaj/Airex/Cotherm/Expo/Secure/Girish/Racold
(c) Indicator bulb 240 V suitable for given make, type and model
(d) PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides, braided reinforced type for cold/hot water connection. Make: Polytuf/ Viking/ Agmeco/ Jayna
(d) PVC connection 15 mm dia 900 mm long with PTMT nuts on both sides, braided reinforced type for cold/hot water connection. Make: Polytuf/ Viking/ Agmeco/ Jayna
(e) Auto cutout for geysers, 95deg C, suitable for any brand and model
Supply and fixing of MCB modular blank plates, made of polycarbonate, glossy finish, rectangular type, thickness minimum 2mm complete all as specified and directed by the Engineer in charge
Supply and fixing electrical panel hylam sheets 3mm thick including cutting for mounting of switches / sockets / of size required as per site requirement complete all as specified and directed.
S & F in replacement of multi stranded flexible wire white, 7/42 AWG, 70RM bundle complete all as specified and directed by the Engineer-in-charge
Supply and fixing of Round sheet 5" complete all as specified and directed by Engineer-in-charge
Supply and fixing of Round sheet 6" all as specified and directed by Engineer-in-charge
Suppy only China nails all as specified and directed by Engineer-in-charge
Suppy only PVC Insulation tape 17mm x 6m, multicolour, Weather Proof, Moisture & Fire Resistant all as specified and directed by Engineer-in-charge
Suppy only 3/4" junction box all as specified and directed by Engineer-in-charge
Suppy and fixing of Heavy duty fan hook all as specified and directed by Engineer-in-charge
Suppy only Wooden gatti all as specified and directed by Engineer-in-charge
Suppy only Wooden screw 1.5" 100pc all as specified and directed by Engineer-in-charge
Suppy only Wooden screw 2" 100pcs all as specified and directed by Engineer-in-charge
Suppy only Bamboo nails 2.5" 1kg all as specified and directed by Engineer-in-charge
Suppy only 1" screw black 500pcs pack all as specified and directed by Engineer-in-charge
Suppy only Hacksaw blade all as specified and directed by Engineer-in-charge
S&F in replacement 400mm swing wall fan, 4star, smooth oscillation, copper motor with remote control, 72 speeds, plastic body including taking down the existing unserviceable fan and depositing it to MES E/M Store complete all as specified and directed
Supply and fixing in replacement LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection with suitable no of nuts, bolts and clamps complete all as specified and directed by Engr-in-charge
S&F 20mm pipe bracket GI for security light with 2 clamps, silver painted, 2mm thickness complete all as specified and directed by the Engineer-in-charge.
Supply and fix electric water heater, vertical storage type with ferroglass coated anti-rust inner container and heating element upto 2 KW capacity 25 litre, heavy duty anode rod, preset thermal cutout, BEE 5 Star rated as per latest BEE norms (i.e. standing losses ≤ 0.465 kWh/24 hour/45°C which is only valid till 31st Dec 2025, material shall be supplied as per latest revision at the time of supply with all accessories such as safety valve, thermostat, NRV, connection piece(hot and cold water connection pipe) etc including taking down the existing unserviceable geyser and depositing it to MES E/M Store complete complete all as specified and directed by Engr-in-charge. Make: Bajaj, Havells, Crompton, Racold, Usha.
Supply and fixing ceiling fans in replacement complete with blades, copper motor, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated as per latest BEE norms in vogue at the time of supply with brushless direct current motor (BLDC) without remote complete including depositing the old fan in MES E/M store complete all as specified and as directed.
Supply and fix in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm including taking down the existing unserviceable fan and depositing it to MES E/M Store complete all as specified and directed
All as per item No. 105 here-in-before but with 200mm sweep complete all as specified and directed
Supply and fix in replacement Exhaust fan, steel body AC Single phase 230 V of size 300 mm sweep with blades, and frame and louvers including taking down the existing unserviceable fan and depositing it to MES E/M Store complete all as specified and directed by Engr-in-charge
Supply and fix in replacement Exhaust fan, steel body AC Single phase 230 V of size 225 mm sweep with blades, and frame and louvers including taking down the existing unserviceable fan and depositing it to MES E/M Store complete all as specified and directed by Engr-in-charge
Supply and laying in replacement of Weather proof flat twin core service cable size 2.5 Sq mm copper conductor PVC insulated and PVS sheathed complete all as specified and directed
Supply and laying in replacement of Weather proof flat twin core service cable size 4 Sq mm copper conductor PVC insulated and PVS sheathed complete all as specified and directed
Supply and laying in replacement of Weather proof flat twin core service cable size 6 Sq mm copper conductor PVC insulated and PVS sheathed complete all as specified and directed
Repairing/overhauling of TPN/SPN DBs of any size/type fixed on building wall incl cleaning with compressed air, tightening of all electric connection to the bus bar & switch gears , refixing of loosed doors with proper fixing & locking arrangement & necessary welding work as required and replacement of wornout/ burnt/rusted/ loose lugs , door lock, nut bolt,hing, washers,internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire ,repair to plaster work as require at site and including disconnection of all cable/ sub main from the bus bar and insulating the naked portion of Al/Cu conductor and re-connect the same after repair of panel and proper connection of main earth wire/lead with panel body using lugs complete all as specified and directed.
Supply and fixing concealed meter box with isolator made from minimum 2mm thick CRCA sheet, to accommodate 1No. Single phase energy meter complete all as specified and directed.
Supply and fixing concealed meter box with isolator made from minimum 2mm thick CRCA sheet, to accommodate 1No. Three phase energy meter complete all as specified and directed.
M&L for cutting round holes suitable for fixing of exhaust fan any size and shape into through stone/brick walls built in cement mortar or cement lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required and plastering in CM 1:4 external / internal surfaces and finished to match with the existing surfaces complete including colour/white wash to the disturbed portion all as specified and directed by Engr-in-charge.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried 6cm dept in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing including porcelain vitreous white seperators and fixing screws with brazing at each possible joint etc. as required 32X6mm GI strip all as directed by Engr in Charge.
M&LEarth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire all as directed by Engr in Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron or steel earth lead strip 32x6 mm size upto 7.5 mtr long in single length by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SSR part I including necessary excavation in hard/dense soil and earth work GI pipe 20mm dia medium grade for watering and GI 40mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to LT panel board as indicated including testing complete all as specified and as directed.
Material and Labour for earthing pit display boards made out of 3mm thick MS sheet of size 30 x 35cm welded to 75cm long 25 x 25 x 5 mm thick MS angle iron grouted in PCC 1:3:6 (with 20mm stone aggregate) to a depth of 20 cm and applying two coats of synthetic enamel paint of approved color over a coat of red oxide primer and writing the letters on plate for showing the following details: 1. EARTHING PIT NO : 2. DATE OF MEASUREMENT : 3. NEXT DUE DATE : 4. STANDARD VALUE : 5. VALUE OBTAINED : Note : Shape, size and colour of display board should be approved by Engr in Charge before fixing at site.
Measurement of earth resistance in presence of user, recording the values in Earth resistance test register, obtaining signature from user at locations and as per timelines prescibed by Engineer-incharge. Note: The necessary T&P shall be provided by the contractor to the person carrying out the job.
S&F in replacement post top lanterns, 35W , IP65 long life aesthetically designed with symmetrical light distribution with high power LED , clear/opaque cover as per site requirement complete all as specified and directed. Make: Havells RUBYNXTPT35WLED or Wipro LP07-431-XXX or similar
M&L for cleaning of Electric chimney, including removing oil and grease from exterior as well as filter, cleaning of motor, assessing the chimney for visual damage and blockages, Thorough cleanup of mesh filter using advanced steam technology, Complete functionality check followed by post-service cleanup, 180 days warranty after the repair complete all as specified and directed by the Engineer-in-charge
S&F of Stainless Steel Oil Collector Baffle Filter Container Tray For Kitchen Chimney 16 Inch (40.74 Cm), non-magnetic complete all as specified and directed by the Engineer-in-charge
S&F Domestic Chimney Bulb Light 1.5W 12V DC, Rectangle Hood Lamp, Energy Efficient, Flicker-Free, Long Lasting, Shock Resistant, made of a stainless steel frame complete all as specified and directed by the Engineer-in-charge
S&F 6 Inch 6ft Flexible Aluminum Duct Pipe for Kitchen Chimney, Complete Installation Kit with Free Cowl Cover, 2m Tape, and Clamp, silver colour complete all as specified and directed by the Engineer-in-charge
Supply only PVC saddle clamp 25mm for electrical conduits complete all as specified and directed by the Engineer-in-charge.
Supply and fixing of heavy duty hanging bolts set for electric geysers of any size and type, 8mm thick, high quality iron material complete all as specified and directed
Supply and fixing of GI bar saddle clamps 3/4" complete all as specified and directed
Cleaning geyser of any type and capacity including turning of water and power supply, draining the tank, removing sediment and scale buildup using vinegar or a descaling solution and flushing the tank with fresh water and reassembling and refixing the geyser complete all as specified and as directed.
Supply and fixing of PVC sticker, water proof, self-adhesive, micro laminated, premium quality digital print, rectangular shape, 5.5x5.5 inch with Do's and Don’t's for usage of electric geysers printed on the sticker complete all as speciifed and directed by the Engineer-in-charge
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_857724.xls
BOQ • 0.49 MB
8946ps.pdf
Tender Documents • 0.68 MB
Download all tender documents and submit your bid