CE (Procurement)
O/o CE (Procurement) Block No.3, Shakti Bhawan, Jabalpur
TR-56/2023 (Design ,Supply of all materials and complete Automation of existing 132 kV Substations i.e. 132 kV Marhotal, 132 kV Ayaodhya nagar and 132 kV Satyasai on total turn-key basis)
2023_MPPTC_312547_1
TR-56/2023
Open Tender
Electrical Works
365 days
MPPTCL Site and Store
As per tender Specification
7 documents required · 7 mandatory
₹11,800
₹11.3 L
Yes
O/o CE (Procurement)
21 Feb 2024
27 Sept 2023
15 Dec 2023
27 Sept 2023
13 Dec 2023
6 Nov 2023
17 Oct 2023
Amount
Erection AND COMMISSIONING OF SAS C&R 132 kV and 33kV C&R Panel
132 kV C&R Panel Type SAS- For Transformer Control (suitable for automation/remote operation)with BCU & all associate items
132 kV C&R Panel Type SAS- For Feeder Control (suitable for automation/remote operation)with BCU & all associate items
132 kV C&R Panel Type SAS- For Bus coupler bay Control (suitable for automation/remote operation)with BCU & all associate items
33 kV C&R Panel (for 1T+2F) Type SAS- (suitable for automation/remote operation)with BCU & all associate items
33 kV C&R Panel (for 3F) Type SAS- (suitable for automation/remote operation)with BCU & all associate items
33 kV C&R Panel (for 2F) Type SAS- (suitable for automation/remote operation)with BCU & all associate items
33 kV C&R Panel for CAP. Bank Type SAS- (suitable for automation/remote operation)with BCU & all associate items
Erection AND COMMISSIONING OF Substation SAS System with Networking Panel SAS-NW
Substation SAS System with Networking Panel SAS-NW
Station HMI [Industrial grade Computer with 23 LED monitor as per specification requirements] With inbuilt storage capacity for Minimum 3Years Substation Data. Antivirus and MS office.
DR workstation [Industrial grade Computer with 23" LED monitor as per specification] along with Station Data Concentrators Hardware/Software and SFTP client Software to transfer DR files to minimum 3 Remote Control Centre. With inbuilt storage capacity for Minimum 3 Years Substation Data. Antivirus and MS office.
Remote NVR HMI [Industrial grade Computer with 70" LED monitor as per specification with antivirus] with Network Video recorder Analytic software with inbuilt storage capacity for minimum 30 days of video playback
A3 Size Color Laser Printer
Mono Crome Laser Printer
Remote Workstation(Main and hot standby) with HMI Industrial grade Computer with 23 LED monitor as per specification] With inbuilt storage capacity for Minimum 3 Years Substation Data along with softwares to receive DR files via SFTP from substation. Antivirus and MS office.
Hardware Gateways connected in PRP (for data transmission to SCADA C/R, SLDC )Multi Protocol, multi control centre support with Minimum – Two(2) dedicated Ports for IEC 61850 Communication. Eight(8) dedicated ports for Remote Control Centres on IEC 60870-5-104 protocol. Two(2) dedicated Serial parts for Remote Control Centres on IEC 60870-5-101 protocol.
Modems (both sending and Receiving End) for communication to SCADA C/R & SLDC & Sub SLDC [Specify the Break Up with Quantity and Unit Prices for various items considered for this component of Price Schedule]
Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification [Specify the Break Up with Quantity and Unit Prices for various items considered for this component of Price Schedule]
Ethernet Switches: All Switches shall be Industrial Grade with front LED and Rear Ports and shall have redundant Power Supply and Support native RSTP, SSH2, SNMPv3 and Shall be IEC61850-3 compliant
132 kV Side C&R: (12 Port (6 Nos. 10/100 Mbps + 6 No. 10/100/1000 Base FX)) connected in PRP
33 kV Side C&R Panels: (24 Port (18 Nos. 10/100 Mbps +6 No. 10/100/1000 Base FX)} connected in PRP
SAS Switch: {24 Port 10/100 Mbps+ 6 port 10/100/1000 Base FX)] connected in PRP
RCC switch: {8 Port 10/100 Mbps+ 4 port 10/100/1000 Base FX}
Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords, LIU(Line Interface Unit) etc., for completing the substation LAN as per specification requirements. [Specify the Break Up with Quantity and Unit Prices for various items considered for this component]
Inverter(3 kVA Capacity) to be Operatable on 230VAC with Battery as per availability of supply (Normally on AC) for local substation
Inverter(1 kVA Capacity) to be Operatable on 230VAC with Battery as per availability of supply (Normally on AC) for remote substation.
Add: Any other Itam bidder may require to complete the avill C&R Panels and SAS system as per specifiention requirements.
Router cum firewall connected in PRP with min 6 months Iog Storage for Remote Access and sending DR and streaming video recorder feed with minimum 4 ethernet interface.
Auxilliary BCU with sufficient input/output modules and 50% spares for Substation Auxiliary Monitoring Controlling (Battery/ACDB/OLTC/Battery and Tap control, Yard Lightinnig, weather station(temperature, humidity,wind etc.,) along with field transducers and other requied accesories.
MFM for ACDB
Erection AND COMMISSIONING OF Other Associated Items
Modular GPS with Redundant Power Supply, Receiver and Antenna to time Syncronise PRP Network on SNTP and IRIG-B
CCTV(Electronice Surveillance System)
Network video recorder(NVR)
Network based IP bullet (outdoor )Array
16 Port switch
JUNITION BOX 12X10
Iron Fabricated Pole mounting (CCTV)
LED Monitors32''
MCB single phase 240V 16A
Cat-6 Armored UTP Cable
DISMANTELLING OF EXIXTING OLD C&R PANELS
De-erection of 132KV C&R PANELS
De-erection of 33KV C&R PANELS
De-erection of RTU and telemetry
GST @18% on Schedule A4
Description of Work / Item(s)
SUPPLY OF SAS C&R 132 kV and 33kV C&R Panel
132 kV C&R Panel Type SAS- For Transformer Control (suitable for automation/remote operation)with BCU & all associate items
132 kV C&R Panel Type SAS- For Feeder Control (suitable for automation/remote operation)with BCU & all associate items
132 kV C&R Panel Type SAS- For Bus coupler bay Control (suitable for automation/remote operation)with BCU & all associate items
33 kV C&R Panel (for 1T+2F) Type SAS- (suitable for automation/remote operation)with BCU & all associate items
33 kV C&R Panel (for 3F) Type SAS- (suitable for automation/remote operation)with BCU & all associate items
33 kV C&R Panel (for 2F) Type SAS- (suitable for automation/remote operation)with BCU & all associate items
33 kV C&R Panel for CAP. Bank Type SAS- (suitable for automation/remote operation)with BCU & all associate items
SUPPLY OF Substation SAS System with Networking Panel SAS-NW
Substation SAS System with Networking Panel SAS-NW
Station HMI [Industrial grade Computer with 23 LED monitor as per specification requirements] With inbuilt storage capacity for Minimum 3Years Substation Data. Antivirus and MS office.
DR workstation [Industrial grade Computer with 23" LED monitor as per specification] along with Station Data Concentrators Hardware/Software and SFTP client Software to transfer DR files to minimum 3 Remote Control Centre. With inbuilt storage capacity for Minimum 3 Years Substation Data. Antivirus and MS office.
Remote NVR HMI [Industrial grade Computer with 70" LED monitor as per specification with antivirus] with Network Video recorder Analytic software with inbuilt storage capacity for minimum 30 days of video playback
A3 Size Color Laser Printer
Mono Crome Laser Printer
Remote Workstation(Main and hot standby) with HMI Industrial grade Computer with 23 LED monitor as per specification] With inbuilt storage capacity for Minimum 3 Years Substation Data along with softwares to receive DR files via SFTP from substation. Antivirus and MS office.
Hardware Gateways connected in PRP (for data transmission to SCADA C/R, SLDC )Multi Protocol, multi control centre support with Minimum – Two(2) dedicated Ports for IEC 61850 Communication. Eight(8) dedicated ports for Remote Control Centres on IEC 60870-5-104 protocol. Two(2) dedicated Serial parts for Remote Control Centres on IEC 60870-5-101 protocol.
Modems (both sending and Receiving End) for communication to SCADA C/R & SLDC & Sub SLDC [Specify the Break Up with Quantity and Unit Prices for various items considered for this component of Price Schedule]
Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification [Specify the Break Up with Quantity and Unit Prices for various items considered for this component of Price Schedule]
Ethernet Switches: All Switches shall be Industrial Grade with front LED and Rear Ports and shall have redundant Power Supply and Support native RSTP, SSH2, SNMPv3 and Shall be IEC61850-3 compliant
132 kV Side C&R: (12 Port (6 Nos. 10/100 Mbps + 6 No. 10/100/1000 Base FX)) connected in PRP
33 kV Side C&R Panels: (24 Port (18 Nos. 10/100 Mbps +6 No. 10/100/1000 Base FX)} connected in PRP
SAS Switch: {24 Port 10/100 Mbps+ 6 port 10/100/1000 Base FX)] connected in PRP
RCC switch: {8 Port 10/100 Mbps+ 4 port 10/100/1000 Base FX}
Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords, LIU(Line Interface Unit) etc., for completing the substation LAN as per specification requirements.
Inverter(3 kVA Capacity) to be Operatable on 230VAC with Battery as per availability of supply (Normally on AC) for local substation
Inverter(1 kVA Capacity) to be Operatable on 230VAC with battery as per availability of supply (Normally on AC) for remote substation.
Add: Any other Itam bidder may require to complete the avill C&R Panels and SAS system as per specifiention requirements.
Router cum firewall connected in PRP with min 6 months Iog Storage for Remote Access and sending DR and streaming video recorder feed with minimum 4 ethernet interface.
Auxilliary BCU with sufficient input/output modules and 50% spares for Substation Auxiliary Monitoring Controlling (Battery/ACDB/OLTC/Battery and Tap control, Yard Lightinnig, weather station(temperature, humidity,wind etc.,) along with field transducers and other requied accesories.
MFM for ACDB
SUPPLY OF Other Associated Items
Modular GPS with Redundant Power Supply,Receiver and Antenna to time Syncronise PRP Network on SNTP and IRIG-B
CCTV(Electronice Surveillance System)
Network video recorder(NVR)
Network based IP bullet (outdoor )Array
16 Port switch
JUNITION BOX 12X10
Iron Fabricated Pole mounting (CCTV)
LED Monitors32''
MCB single phase 240V 16A
Cat-6 Armored UTP Cable
GST On Schedule-A1 @18%
SCOPE T and M Pvt Ltd
SCOPE T and M Pvt Ltd
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid