Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹43.5 L+₹3.9 L (9.83%)Rejected-Finance MIRZAPUR MUMTAZ NAGAR AYODHYA AYODHYA UTTAR PRADESH 224001 | AYODHYA | UTTAR PRADESH | 224001 | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Eligible for Part I |
Tender Value
₹40 L
EMD Value
₹40,000
Closing Date
8 Jan 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
EDC, Ayodhya
112 H(F)(W)/2024-25
2024_MVVNL_986024_1
112 H(F)(W)/2024-25
Open Tender
Electrical Works
Item Wise
90 days
Ayodhya
As Per Tender Specification
2 documents required · 2 mandatory
₹3,540
Superintending Engineer, EDC
₹40,000
21 Jan 2025
23 Dec 2024
9 Jan 2025
23 Dec 2024
8 Jan 2025
23 Dec 2024
Amount
Part - A ( Material) Following Material Supplied by the Contractor:-
Top Channel Holding Clamp
Dropper Holding Clamp
11 KV F Clamp
Guarding Angle Clamp
Danger Board
Holding Clamp for Dropper /T-off/Top
Stone Pad
nut and Bolt
Aluminum lug 250 KVA T/F
Eye Hook with Clamp
L.T. Clamp
LT Shackle Insulator
Carriage including loading,unloading & Proper stacking of following Stock materials from store/departmental store to Dump site distance 0 to 70 Kms. (distance approx)
PCC Pole 8.5 Mtr. Long
ST Pole 11 Mtr. Long
AB Cable 3x50
AB Cable 3x95
AB Cable 3x120
Distribution Box
XLPE Cable 3.5x240 sqmm
Transformer 16 KVA
Transformer 25 KVA
Transformer 63 KVA
Transformer 250 KVA
Transformer 400 KVA
Line Isolator 800 A 33 KV
11 KV VCB I/C CTR 600/300/5A 350 MVA 24 Volt (1250 AMP)
11 KV VCB O/G CTR 200/100/5A 350 MVA (1250 AMP)
11 KV XLPE Cable 3x185 sqmm
11 KV Cable Jointing kit 3x185 sqmm indoor
11 KV Cable Jointing kit 3x185 sqmm outdoor
ACSR Weasel Conductor
Other matching Materials
Dragging of PCC Pole from dump site to pit site
Dragging of ST Pole from dump site to pit site
Fabrication and Errection of Double Pole Support on PCC/ST Pole Pole including grouting with 1:4:8 ratio Cement, sand & Brick Ballast& including digging of pit and fixing of all accessories clamp & earthing as per RESPo Norms. (Cost of clamps borne by contractor)
Fabrication and Errection of Single Pole Support on PCC/ST Pole Pole including grouting with 1:4:8 ratio Cement, sand & Brick Ballast& including digging of pit and fixing of all accessories clamp & earthing as per RESPo Norms. (Cost of clamps borne by contractor)
Stringing, Sagging, Binding and jumpering of AB Conductor (3x50) as per RESSPO Norms
Stringing, Sagging, Binding and jumpering of AB Conductor (3x95) as per RESSPO Norms
Stringing, Sagging, Binding and jumpering of AB Conductor (3x120) as per RESSPO Norms
Stringing, Sagging, Binding and jumpering of ACSR Weasel Conductor as per RESSPO Norms
Grouting and Binding of Stay with in 1:4:8 ratio with cement, sand and brick ballast including cost of all grouting materials as per RESSPO Norms
Earthing of Poles as per RESPO Norms
Mounting of 16 KVA Transformer as per RESSPO Norms.
Mounting of 25 KVA Transformer as per RESSPO Norms.
Mounting of 63 KVA Transformer as per RESSPO Norms.
Mounting of 250 KVA Transformer as per RESSPO Norms.
Mounting of 400 KVA Transformer as per RESSPO Norms.
Connection of L.T. XLPE Cable Different Size & Different Places
Laying of underground 11 KV 3x185 sq mm XLPE Cable in Normal Soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, Ist class bricks as per norms. (All the material will be supplied by the contractor except 11 KV XLPE cable)
Hanaging, Hosting & clamping of G.I. Pipe, channel, nut & Bolt 3x185 mm2 XLPE 11 KV cable as per RESSPO Norms (cost of all accessories will be borne by contractor)
Installation of Heat Shrinkable Type cable jointing kits Outdoor end Termination suitable for 11 KV XLPE cable 3x185 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.)
Installation of Heat Shrinkable Type cable jointing kits Indoor end Termination suitable for 11 KV XLPE cable 3x185 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.)
Construction of Transformer Plinth size 2x2x1.5 including excavation of foundation, base concreting of 1:6:12 (Cement mortar of Ratio 1:4 foundation, CC in 1:4:8 ratio (Cement fine sand and brick ballast ) and RCC work with ratio 1:2:4 Cement, Coarse sand and Stone Grit of 20 mm gause as per RESSPO norms
Fencing of Transformer Plinth with the help of wire mesh/Barbed wire after grouting proper size of angle as per RESSPO Norms. Inclusive of all material such as Wiremesh/Barbed Wire, Angle Flats, Nut Bolts etc.
Earthing by way of boring and lowering of "B" class G.I. pipe 50 mm dia 20 mtr. Long from ground upto the water lavel it will be connected to the G.S. Strip for T/F nutral connection the earth strip will be welded to the G.I. pipe the work also included top cap and clamps for pouring water the cost of all material will all labour and T n P etc. complete in all respect . (all the material will be supplied by the contractor.)
Installation of Line Isolator 800 A 33 KV
Installation of 11 KV VCB I/C CTR 600/300/5A 350 MVA 24 Volt (1250 AMP)
Installation of 11 KV VCB O/G CTR 200/100/5A 350 MVA (1250 AMP)
Erection & Commissioning of of 3 Phase/Single Phase Distribution Box with help of clamps (Cost of clamp & Bolt & Nuts shall be borne by contactor ) as per Norms.
Rect. Back old and used 10 KVA T/F
Rect. Back old and used 16 KVA T/F
Rect. Back old and used 100 KVA T/F
Rect. Back old and used 250 KVA T/F
Hindustan Electric Work (BID ID -4829751)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .