| Sl No | Description | Qty | Unit | HYDROCON ENGINEERS L2 | Gupta Brothers L1 |
|---|---|---|---|---|---|
| 1.01 | Making and supply of cubical panel for incomer power supply suitable for up to 30 HP pumps load, made out of 16 SWG CRCA sheet, indoor type, duly painted with power coating, complete with following switchgears and instruments duly installed with their complete connection and inter connections with proper cables etc. as per requirement and with cable connectors for making required power supply connections by fixing the 4 pole 200 A MCCB with spreader terminals, 3 ph earth fault relay, Led indicators each for R,Y and B, 3 nos SP MCB 6A, onload changeover switch with enclosure 200 A, panel fabrication of suitable size to fit above items comfortably, wiring and labour as required. It also include any left out items required for proper operation of the panel. Make of the components to be used:- L&T/C&S/Schneider/C&S/ABB/HPL/DJB approved | 8 | Nos | 5,60,000 ₹6,60,800 | 5,28,000 ₹6,23,040 Lowest |
| 1.02 | Making incoming connections to be incomer panel by connecting the main supply and the panel by the existing cables as per site requirements. | 8 | Jobs | 80,000 ₹94,400 | 22,000 ₹25,960 Lowest |
| 1.03 | Making the connection from the incomer panel to existing starters/panel for operations of pump by providing and fixing of new copper cables of suitable rating as per site requirement including laying of cable/making end terminations etc. as per requirement. | 8 | Jobs | 80,000 ₹94,400 | 70,400 ₹83,072 Lowest |
| 1.04 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. DSR E&M 2025 5.2 | 8 | set | 76,000 ₹89,680 | 60,800 ₹71,744 Lowest |
| 1.05 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR E&M 5.11 | 120 | mtr | 12,000 ₹14,160 Lowest | 90,000 ₹1,06,200 |
| 1.06 | Testing and commissioning of the incomer panel at No load and On load as per site requirement. | 8 | Jobs | 20,000 ₹23,600 Lowest | 28,000 ₹33,040 |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
14 Aug 2026, 11:15 amClosed
Executive Engineer (EnM) M-8
Office of the Executive Engineer (EnM) M-8 Nangloi Phase-III, Near Maharaja Surajmal Stadium Metro Station New Delhi-110041.
Provisioning and installation of earthing and earth leakage fault protection system of various secondary BPS in Sector-7 and 8 of AC-13 Rohini.
2026_DJB_296477_1
NIT No.08 /EE(EnM)M-8/2026-27 Item 09
Open Tender
Civil Works
Works
30 days
Nangloi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 50448339804
₹19,000
Yes
16 Sept 2026
5 Aug 2026
14 Aug 2026
5 Aug 2026
14 Aug 2026
5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Making and supply of cubical panel for incomer power supply suitable for up to 30 HP pumps load, made out of 16 SWG CRCA sheet, indoor type, duly painted with power coating, complete with following switchgears and instruments duly installed with their complete connection and inter connections with proper cables etc. as per requirement and with cable connectors for making required power supply connections by fixing the 4 pole 200 A MCCB with spreader terminals, 3 ph earth fault relay, Led indicators each for R,Y and B, 3 nos SP MCB 6A, onload changeover switch with enclosure 200 A, panel fabrication of suitable size to fit above items comfortably, wiring and labour as required. It also include any left out items required for proper operation of the panel. Make of the components to be used:- L&T/C&S/Schneider/C&S/ABB/HPL/DJB approved | 8 | Nos | 80 | ₹640 |
| 1.02 | Making incoming connections to be incomer panel by connecting the main supply and the panel by the existing cables as per site requirements. | 8 | Jobs | 80 | ₹640 |
| 1.03 | Making the connection from the incomer panel to existing starters/panel for operations of pump by providing and fixing of new copper cables of suitable rating as per site requirement including laying of cable/making end terminations etc. as per requirement. | 8 | Jobs | - | - |
| 1.04 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. DSR E&M 2025 5.2 | 8 | set | - | - |
| 1.05 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR E&M 5.11 | 120 | mtr | - | - |
| 1.06 | Testing and commissioning of the incomer panel at No load and On load as per site requirement. | 8 | Jobs | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
BOQ_394676.xls
BOQ • 0.26 MB
Corrigendum08.pdf
PDF • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .