| 1 | L1₹3.2 LAccepted-AOC | L1 | Accepted-AOC Being qualified as L1 bidder | |
| 2 | L2₹2.9 L+₹14,490 (5.34%)Rejected-Finance | L2 | Rejected-Finance Did not qualify in Financial Bids Evaluation as L1 bidder. |
Tender Value
₹3.1 L
EMD Value
₹6,182
Closing Date
7 Aug 2023, 3:00 pmClosed
Executive Engineer (E), BSNL, Bhubaneswar
Door Sanchar Bhawan, Unit-IX, Bhubaneswar-751022
Misc. Electrical works
2023_BSNL_162781_1
NIT No- 22/BSNL-EDB/2023-24
Open Tender
Electrical Works
Item Rate
15 days
GOSANI GAJPATI ODISHA
3 documents required · 3 mandatory
₹590
A O (Cash), BSNL, O/o GMTD, Bhubaneswar.
₹6,182
Yes
6 Feb 2024
31 Jul 2023
8 Aug 2023
31 Jul 2023
7 Aug 2023
31 Jul 2023
31 Jul 2023 - 4 Aug 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP-A
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core flexible cable in the existing surface/ recessed steel/ PVC conduit as required.
4X10sqmm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100 mmX75 mm)
6 Module (200 mmX75 mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
Supplying and fixing 5 stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (2M)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). a) 4 way (4 + 12), Double door (Make- Legrand/L&T/Hager
Supplying and fixing following rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/Siemens/ L & T)
63 Amp 4 pole isolator
63 Amp 4 pole MCB
6-32Amps Single pole
Blanking plate
Supply and fixing of 20 watt, 65000K LED Batten suitable for operation on 140 volts to 270 volts AC, 50Hz i/c fixing and connection etc. as required. (Havells /Phillips /Crompton)
Supply and fixing of the following type lamp holders /lamps i/c connection, testing etc. as required.
Polycarbonate Angle Holder
14/15-watt LED lamp suitable for B22 holder
Supply and Fixing of 30 watt new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 along with fixing bracket made of 32/40mm dia medium class GI pipe with clamps i/c connection, testing etc. as required.
Supply and Fixing of 1200mm sweep superior quality Ceiling fan suitable for operation on 230 volts 50Hz, AC supply, connection, testing etc. complete as required. (Make- Havells: Pacer / Usha Striker)/Equivalent)
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing RCC ring of 300 mm dia and 450 mm depth enclosure with RCC cover plate having lifting arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
Supply and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Supply and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply and fixing of earth bus of 50 mm x 5 mm GI strip on surface above suitable size insulators, drilling holes for connections etc. complete as required.
Providing and fixing 6SWG dia G.I. wire on surface / recess for loop earthing as required.
Supply of the following size PVC insulated & PVC sheathed Aluminium conductor armoured cable 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 i/c transportation etc. as required.
4 core 25 sqmm
Laying of 4X10sqmm / 4X16sqmm / 4X25sqmm XLPE/PVC insulated Aluminium conductor armoured cable in Air etc. as required.
Laying of 4X10sqmm / 4X16sqmm / 4X25sqmm XLPE/PVC insulated Aluminium conductor armoured cable on surface of wall with GI saddles etc. as required.
Laying of 4X10sqmm / 4X16sqmm / 4X25sqmm XLPE/PVC insulated Aluminium conductor armoured cable in masonary open duct/on air etc. as required.
Supplying and making end termination for 4X16sqmm / 4X10sqmm / 4X25sqmm Al. cond. Armd. Cable with brass compression glands and al. sockets/lugs etc. as required.
Supplying and fixing of 40 mm dia medium class GI pipe Directly in ground as per specification for LT cable for protection of LT power cable as required.
Supplying and fixing of 40 mm dia medium class GI pipe On surface of wall/on pole with necessary clamping arrangement for LT cable for protection of LT power cable as required.
Supply and laying of 6SWG dia GI wire along with cables/ conduits as bearer wire/for loop earthing etc. as required.
Supply of 9 mtrs. long PSC pole (conforming to IS: 1678/ 1998 as amended up to date) with working load 300 Kg. including transportation to site, loading and unloading etc. complete as required.
Erection of PSC pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. (a) Above 8.0 meter and up to 11.0 meter
Providing and making PSC pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape above the ground level including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted)
Providing Coil earthing for PSC/Metal HT/LT line Poles using 8 SWG GI wire closely wound for 115 turns with coil dia 50mm and length 450mm erected below 1500mm from ground level including excavation, refilling the trench etc. as required.
Supplying and erection of stay set complete (galvanized) with 19/20 mm dia X 1.8metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow lightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying and erection of G.I. channel iron 75 mm X 40 mm X 6 mm (7.14 kg per meter) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Supplying and erection of 75 mm X 90 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required
Supply of 3X35sqmm + 1X25sqmm AB Cable of XLPE insulation for 3 phase 4 wire 400/250 volts OH line i/c transportation to site etc. as required. The phase conductors shall be of multi stranded aluminum of compacted circular cross section. The aluminum shall comply with IS 8130:1984. The messenger conductor shall be of multi stranded Aluminum Alloy conforming to IS 398 (Part 4) 1994.
Supply and fixing of pole Clamps made of 50mmX5mm G.I. flats with suitable size G.I. nuts, bolts and washers and G.I. Eye hooks on 9 mtrs long (300Kg) PSC poles for laying/drawing of AB cable etc. complete as required
Laying / Drawing of 3X35sqmm + 1X25sqmm AB Cable on 9 mtrs long PSC pole i/c binding with AAA conductors etc. as required.
Supply & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscriptions in signal red colour on front side i/c fixing on poles with suitable size clamps etc. as reqd. a) For Medium Voltage size 200mm x 150mm
Supply of exhaust fans by a new complete set of 380mm /15" heavy duty 1400 RPM Exhaust Fans having maximum free air delivering capacity not less than 3250 m3/ hour (1910 CFM) and maximum sound level not more than 60-65 db. with a capacitor start and run type, continuously rated, totally enclosed and ruggedly built motor having pre-lubricated double ball bearing with Class "A" and "E" insulation suitable for operation on 230 volts single phase 50 HZ AC supply with features for smooth & silent operation to deliver the maximum output at lower operating cost. The impeller of the Exhaust Fan is to be propeller type and both hub and impeller are to be dynamically balances and frames and arms mounted on rubber bushing so that, vibration are virtually eliminated. (Make- Almonard HD (ISI) / Crompton Greaves or similar superior) (Excluding installation)
380mm /15" heavy duty 1400 RPM, maximum free air delivering capacity not less than 3250 m3/ hour (1910 CFM) and maximum sound level not more than 60-65 db.
Installation of exhaust fan up to 450mm sweep in the existing opening with fastener/ GI nuts and bolts after removing the faulty/damaged if required, including making good the damage, connection, testing, commissioning etc. as required
Supplying and installation of gravity type Aluminum/ GI louver shutters suitable for 380mm sweep exhaust fans with fastener /GI nuts and bolts etc. complete as required
Making opening on brick wall of suitable size for fixing of 380mm sweep Exhaust Fans including making good the damages, minor civil works etc. complete as required. (For room BTS sites)
Supply of 450mm X450mmX50mm size panel type Inlet Air Filter having washable Synthetic Fiber filtration medium, GI/Aluminium frame with aluminium /spray iron protect mesh capable for air filtration 35 microns (maximum size ) and maximum air handling capacity of 2000 CFM, including fixing the same in existing GI /MS frame structure etc. complete as required.
Supply of inlet Air filter housing cum louver unit of following overall size , made of 18 SWG GI sheet with collars of about 50mm width in all front sides , suitable size drill holes for fixing the same on wall, detachable 18 SWG thick, 10mm width GI supporting strip of length 560 mm with drill holes at both ends in front facia for holding the air filter in position, louver blades of 100mm width of required quantities shall be welded horizontally at back side of the filter housing frame with half of the portions remain outside the frame at an angle of about 30 deg downwards to prevent entering of rain water into the room/shelter , a GI /stainless steel protective wire mesh type (25mmX25mm - 2.64mmX2.64mm ) ( Wire diameter 14 SWG-2.64mm, distance from centre to centre of wire - 25mm for both main and cross) i/c 19x3mm MS flat protection grill to be welded inside the GI sheet housing frame, painting the welded spots by aluminium oxide paint etc. as per the direction of Engineer in charge, including fixing the same in existing opening with Fastener /GI nuts and bolts etc. complete as required.
Overall Size 460mm (Width) X 450 mm (Height) X 300 mm (Depth) - For Room BTS sites
Making of air inlet opening on brick wall of approximate size 450mmX460mm, suitable for fixing the filter housing cum louver unit including making good the damages, minor civil works etc. as required.
Supply and fixing of 2 Amps, C- Series, 240 volts, 50 Hz, 10 KA SP MCB in existing MCBDB for exhaust fan protection i/c connection, testing etc. as required.
Supply of 3core 1.5sqmm PVC insulated and PVC sheathed copper conductor un-armoured cable i/c laying of the same on surface of wall/shelter with PVC C- clamps or on existing cable tray etc. complete as required.
Supply and Fixing of 63Amp 4-pole on load change over switch in sheet steel enclosure , front handle type (Make: HPL Socomec /Havells / L & T) .
Liaison with the DISCOM authority for obtaining permission/Demand note for 3 Phase LT 3 phase power supply to BTS site i/c site visit with DISCOM's officer/staff, co-ordination for obtaining Demand notes and payments by BSNL to the DISCOM, arranging completion certificates/Drawings/Layouts and other requisite documents for inspection of the installation by the Electrical Inspector, making all arrangements for inspection of site by the Electrical Inspector and obtaining Inspection report from him, (Any fees towards inspection will be paid by BSNL or will be paid separately), making arrangements and coordination with DISCOM offices for execution of agreement by BSNL authority with DISCOM and release of charging order, making arrangements for submission of test reports in prescribed formats to DISCOM, co ordination with MRT section and field staff of DISCOM for energisation of 3 phase power supply to the BTS etc. complete as required.
M/S PRACHI ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .