Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | ₹33.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹36.5 L+₹2.6 L (7.75%)Rejected-Finance H NO 831 1 HINDU NAGAR TILAKWADI BELGAUM 590006 | BELGAUM | BELGAUM | KARNATAKA | 590006 | ₹36.5 L+₹2.6 L (7.75%) | L2 | Rejected-Finance Second lowest |
| 3 | L3₹39.0 L+₹5.2 L (15.3%)Rejected-Finance FLAT NO 1004 BUILDING NO L 11 KEDAR HOUSING SOCIETY 10TH FLOOR SECTOR NO 21 TALOJA PHASE 2 PANVEL RAIGAD NAVI MUMBAI 410208 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410208 | ₹39.0 L+₹5.2 L (15.3%) | L3 | Rejected-Finance Third lowest |
| 4 | L4₹40.4 L+₹6.5 L (19.3%)Rejected-Finance 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹40.4 L+₹6.5 L (19.3%) | L4 | Rejected-Finance Fourth lowest |
| 5 | L5₹41.6 L+₹7.7 L (22.9%)Rejected-Finance | ₹41.6 L+₹7.7 L (22.9%) | L5 | Rejected-Finance Fifth lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Apr 2024, 6:00 pmClosed
GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
REPLACEMENT REPAIRS TO LT PANELS OUTDOOR AND INDOOR LT OH AND UG CABLING ALONG WITH CONNECTED WORKS AT AFS SAMBRA
2024_MES_648498_1
GE(AF)/SAM/TOK-05 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF Sambra
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE AF Sambra
₹90,000
Yes
7 Jun 2024
30 Mar 2024
1 May 2024
30 Mar 2024
29 Apr 2024
17 Apr 2024
Amount
M&L for disconnecting LT cables from the panel of 16 to 95 Sqmm, 3.5 core/4 core size along with cable glands, cutting out the burnt/over heated cable ends with necessary excavation and making new connections using new aluminium lugs of appropriate size including insulation tapes, refixing the cable gland and making all connections & testing for proper smooth functioning/ working complete all as directed:-
All as per Srl item No.1 above but 120 to 240 Sqmm, 3.5 core
S&F in replacement MCCB 4 pole 400Amps 415 Volts, Adjustable type with breaking capacity 36 KA including connecting up with suitable aluminum cable lugs etc.complete all as specified and directed
S&F in replacement MCCB 4 pole, 250Amps 415 Volts, Adjustable type with breaking capacity 25 KA including connecting up with suitable alumnium cable lugs etc.., complete all as specified and directed
S&F in replacement MCCB 4 pole, 200Amps 415 Volts, Adjustable type with breaking capacity 25 KA including connecting up with suitable alumnium cable lugs etc.., complete all as specified and directed.
S&F in replacement MCCB 4 pole, 100 Amps 415 Volts, Adjustable type with breaking capacity 16 KA including connecting up with suitable alumnium cable lugs etc.., complete all as specified and directed
S&F in replacement MCCB 4 pole, 63Amps 415 Volts, Adjustable type with breaking capacity 16 KA including connecting up with suitable alumnium cable lugs etc.., complete all as specified and directed
S&F in replacement MCCB 3 pole, 100 Amps 415 Volts, Adjustable type with breaking capacity 16 KA including connecting up with suitable alumnium cable lugs etc.., complete all as specified and directed
S&F in replacement MCCB 3 pole, 63Amps 415 Volts, Adjustable type with breaking capacity 16 KA including connecting up with suitable alumnium cable lugs etc.., complete all as specified and directed
Note for items 3 to 9 :- Quoted rate is deemed to be included the necessary minor modifications such as making additional holes / cutting slots etc in the existing panel if found required for fixing the MCCB it shall be carried out without additional rate and rate for which shall deemed to be included in the above quoted rate.
S&F in repairs enclosure of MCCB suitable size for mounting of MCBB 100-400 Amps, 4 pole complete all as specified and directed.
Supply, install, testing and commissioning of floor mounted LT feedar pillar AC 415 Volts, 50 HZ 3 Phase, 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, suitable for outdoor use, with bottom cable entry with suitable cable glands, structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs, hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated, including taking down old / rusted pillar complete all as specified and directed :- (Main Panel) NOTE:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires. The pillar box shall be provided with durable and legible Aluminium nameplates for each MCCB containing Qtr No/Bldg No and FPB No.
M&L for spray painting for panel with one coat of primer and two coats of synthetic enamel paint of smoke gray colour after throughly preparing, cleaning In & Out side of the panel complete all as specified and as directed.
S&F in replacement broken hinges 100mm size of LT Panel, rusted portions of LT Panle, DB, steel tubular poles etc through electric welding including denting and painting with two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
M&L for for HT/LT Cable route indicator with a welded/riveted disc of 4 inch dia and engraved with cable with cable route marker made out of angle iron 40 x 40 x4 mm thick dug in ground with in and incl PCC 1:3:6 type C1 using 20mm graded aggregate at approx distance 100 mtr including necessary earth work complete all as specified and directed
M&L for L T under ground cable, XLPE insulated, armoured, heavy duty electric cable with aluminium conductor 1100 Volts grade in trenches / passing through pipes of following cross sectional area including taking out old existing unserviceable cables:- Note:- Excavation and earth work, DWC pipe shall be measured and paid separately.
3 1/2 core 120 sqmm
3 1/2 core 70 sqmm
3 1/2 core 50 sqmm
3 1/2 core 35 sqmm
4 core 25 sqmm
4 core 16 sqmm
2 core 16 sqmm
2 core 10 sqmm
S&F in repair Aluminium lugs suitable for UG cable of size 3 .5 / 4 core, 25 / 16 sqmm including respective size of lugs for the neutral cable complete all as specified and directed
All as per Sl item No 16 here in before but for UG cable of size 3.5 core 50 / 70 sqmm.
All as per Sl item No 16 here in before but for UG cable of size 3.5 core 95 / 120 / 185 sqmm.
M&L for Straight through jointing heat shrinkable kit for cable of 185/120/95/70 sqmm 3.5 core LT cables suitable for aluminium conductor including necessary earth work excavation including taking down old unserviceable kit complete all as specified & directed
All as per item No 19 herein before but 50/35/25 sqmm x3.5 core
Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in hard/dense soil complete all as specified and as directed.
All as per Srl item No. 21 here-in-before but exceeding 1.5 m deep and not exceeding 3.0 m deep.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soil complete all specified and as directed.
Removing excavated materials /soil to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all specified and as directed.
S&F Double wall corrugated HDPE Pipe IS-16205, outer dia 120 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed
S&F Double wall corrugated HDPE Pipe IS-16205, outer dia 75 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed
S&F Double wall corrugated HDPE Pipe IS-16205, outer dia 40 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed
Cutting the tar macadam road / hard standings for laying cable and excavating not exe. 60cm wide and n. exc 75cm depth and getting out all as directed including filing back, consolidating etc complete and finishing it with 200mm thick PCC 1:4:8 type D-2 complete all as specified and directed
M&L for for PVC insulated flat twin core sheathed cables standard aluminium conductor 1.1 KV grade of size 10 sqmm cable including taking down old cable complete all as specified and directed
All as per Srl item No.29 above but 16 sqmm cable
All as per Srl item No.29 above but 6 sqmm cable
S&F galvanised iron pipes 50 mm bore,. light grade, with all fitting and fixed complete to poles/route/drains etc and ceillings or laid in floors complete all as specified and directed
All as per item No 32 herein before but 40 mm bore
All as per item No 32 herein before but 80 mm bore
S&F L T RCC poles 09 mtr long 102X172 mm at top and 102X279 mm at bottom class 10 erecting in vertical position and applying cement based paint upto 1.2 mtr height from top of coping and then paintof 03 Nos of each black and yellow alternate strip of 20 cm width upto GL including removing broken pole from site complete all as specified and directed
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in foundation filling for poles complete all as specified & directed
M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in foundation filling for poles complete all as specified & directed
M&L for cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as coping around poles etc complete including necessary formwork and finishing the exposed surfaces even and smooth without using extra cement all as specified and as directed.
M&L for painting of PCC/RCC poles 9 mtr height with two coats of synthetic enamel paint alternatively with black and yellow strip of width 150mm up to a height of 1.50mtr from ground level and applying one coat of cement wash for the remaining height including writing pole Nos complete all as specified and directed
M&L for painting steel tubular poles 9 mtr height with two coats of synthetic enamel paint alternatively with black and yellow strip of width 150 mm up to height of 1.5mtr from ground level / coping including writing pole number including cross arms with one coat of aluminium paint from bottom to top after cleaning and preparing the surface complete all as specified and directed
M&L for connecting the Street Light point from Loop in Loop out box by using a two runs of single core 1.5 Sq.mm. PVC insulated sheathed FR copper conductor cable including PVC conduit/Flexible Pipe of Suitable dia along with one run of 1.5 Sq.mm FR copper cable for earth continuity conductor as earth lead for Street Light complete all as specified and directed Note: The rate includes taking down the old unserviceable conduit.
M&L for stay assembly with complete accessories as shown in electrical plate No. 1 using 20 mm dia stay rod complete all as specified and directed Note : loop type insulator, stay clamps, excavation and concrete will be measured and paid separately
S&F GI stay strand of size 7/4.00 mm complete all as specified and directed
S&F loop type insulator large size with over all dimensions 90x140mm, clearance of hole 25.5mm complete all as specified and directed
S&F Aluminum conductor, steel reinforced ( ACSR ) drawn / fixed on poles including aluminum binding wire for jumpering, dismantling old U/S conductor complete all as specified and directed
S&F PVC spacers 4 way for LT OH line 1100 volts grade with necessary screws nuts bolts etc complete all as directed to prevent the lines touching each other on heavy wind as a preventive arrangement to the existing system including removing the existing old / out lived spacers complete all as specified and directed
Straining only existing over head line loose conductors/ GI wire of any line of wires or any size complete all as directed (One span not more than 50 metre) complete all as specified and directed
Cutting tree branches below, top and around the OH conductors not less than two metre around the line and keeping the line clearance throughout the contract period by trimming the branches repeatedly as many times as required, depending on the growth of new branches including clearing the site by depositing the branches to a distance not exceeding 50m all as specified and directed
S&F Pin type porcelin vitreous white brown or green insulator including one galvanised steel spindle two galvanised washers and GI nut bolt 100 mm height for 1100 volts grade LT including taking down the old broken complete all as specified and directed
All as per Srl item No 49 herein before but shackle type insulator for LT 1100 volts
M&L for mild steel cross arms, angles, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including painting with two coats of Aluminium paint over a coat of red oxide primer complete all as specified and directed
M&L for spreading 40 mm coarse graded aggregate (blue metal) in the substation yards/as indicated locations complete all as specified and as directed Note:- Aggregate should be laid after scrapping of existing aggregate and levelled at various transformer yard/locations as indicated.
S&F Galvanised steel wire 4 mm dia complete all as specified and directed
S&F in replacement LED Mushroom decorative gate light fitting made of high grade unbreakable polycarbonate material suitable for retrofit LED B22 base with 9W/10W lamp including LED driver complete all as specified and directed
S&F in replacement PLUTO PRO LED Flood light fittings 200 Watt, presure die cast aluminium housing, toughened glass and high power LEDs, secondary lenses with IP 66 protection including Surge Protection Devices 10 KV, Heat resistant, resistant TRS cable, 6000-6500K cool white colour complete with all accessories & necessary fixing arrangement i.e. GI clamps, nuts bolts and washers etc complete all as specified and directed
S&F in replacement ROVER PLUS LED Flood light fittings 100 Watt with presure die cast aluminium housing, toughened glass and high power LEDs, secondary lenses, IP 66 protection, surge protector device 10 KV, with all accessories & necessary fixing arrangement i.e. GI clamps, nuts bolts and washers etc complete all as specified and directed
S&F in replacement ROVER LED Flood light fittings 50 Watt with presure die cast aluminium housing, toughened glass, high power LEDs, secondary lenses, IP 66 protection, surge protector device 10 KV with all accessories & necessary fixing arrangement i.e. GI clamps, nuts bolts and washers complete all as specified and directed
S&F in replacement street light fitting ASTRA NEO LED 25 watt, pressure die cast housing, toughened glass and high power LEDs with secondary optics, IP-66 protection including necessary fixing arrangement i.e. GI clamps, nuts bolts and washers complete all as specified and directed
S&F in repairs earth continuity conductor or main earthing lead with aluminium strip of size 25x3mm mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all as specified and directed
S&F in repairs earth continuity conductor or main earthing lead with copper strip of size 20x3mm mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all as specified and directed
S&F in repairs earth continuity conductor or main earthing lead with galvanised iron strip of size 32 x 6 mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all as specified and directed
M&L for earthing and testing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 M below normal ground level with top edge of earth plate at a depth not less than 1.5 M below normal ground level connected to and including GI wire 4 mm as earth lead by means of bolts and nuts, check nuts and washers etc made of GI & connected to equipment and earthing test point , earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work, excavation PCC chamber cover with handle (PCC 1:2:4) and 20mm dia GI watering pipe and 25 mm dia light grade GI for protection of earth strip, wire mesh, funnel, charcoal dust & common salt, etc all as specified and directed and testing on completion including taking down old earthing all as specified and directed .
M&L for earthing and testing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 M below normal ground level with top edge of earth plate at a depth not less than 1.5 M below normal ground level connected to and including GI strip 32x6 mm as earth lead by means of bolts and nuts, check nuts and washers etc made of GI & connected to equipment and earthing test point , earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work, excavation PCC chamber cover with handle (PCC 1:2:4) and 20mm dia GI watering pipe and 25 mm dia light grade GI for protection of earth strip, wire mesh, funnel, charcoal dust & common salt, etc all as specified and directed and testing on completion incl taking down old all as specified and directed .
S&F in replacement timelite distribution board of 32 Amps 3 pole 230 Volts Analog time switch all as specified and directed after dismantling the existing U/S timer control box complete all as specified and directed
All as per Srl item No.64 above but 16 Amps 3 pole 230 Volts analog time switch
S&F in replacement FRP junction box of size 295 mm x 255 mm x 160 mm with self locking arrangement comprising of one No MCB SP 06 Amps with suitable din chanel, 4 way 32A PVC connector fixed to pole with Flat iron clamps of size 25x4 mm, nuts and bolts and connecting the incoming and out going cables complete all as specified and directed
S&F in repairs 3 pole power contactor 32 Amps rated capacity, 50 cycles 220/240 Volts including incoming and outgoing wiring with copper conductor of 10 Sq mm size with suitable copper lugs including taking down the existing unserviceable contactor complete all as directed.
M&L for replacement earth chamber of size 700x700mm (External size) with PCC 1:3:6, Type C-1 (using 20mm graded stone aggegrates) including necessary earth work in any type of soil all as shown in Electrical Plate No. 03 of MES Schedule Part I complete all as specified and directed
M&L for replacement of broken earth chamber cover of pre-cast RCC 1:2:4 type B-1 (using 20mm graded stone aggergates) of size 550x550x40mm thick reinforced with 8mm dia TMT steel bars @10cm centre to centre in both direction and 12mm dia MS handle of suitable size all as shown in Electrical Plate No. 03 of MES Schedule Part I complete as specified and as directed.
S&F in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
S&F in repair Air termination, single pointed aluminium rod 12mm dia and 300mm long fixed to overhead reservoir as in lightening protection with necessary connections to earthing etc complete all as specified and directed.
Labour only for Checking and measuring earth pit resistance value by using 3 pole method using Fluke Make meter at earth pits complete all as directed Note: (i) T & P required for testing shall be arranged by the contractor without any extra cost to the Govt. (ii) The measurement are required to be taken as and when directed by the Engr-in-Charge during the contract period (iii) The contractor shall provide minimum one electrician and one helper daily during working hours for this purpose during contract period (iv) All reading are to be recorded in earth register measurement books which are to be maintained properly duly signed by the Engr-in-Charge
M&L for maintenance of existing earthing system by cleaning the earth chamber funnel and adding adequate water with 20Kg salt complete all as specified and as directed.
DHAIRYASIL RAMAKANT DESAI
M/s ASPIRE ENGINEERING ENTERPRISES
SHIVANI ENTERPRISES
ASHIRWAD ELECTRICALS
M/s. VIJAY ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .