Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹48.5 LAccepted-AOC | 1 | Accepted-AOC Lowest Bidder | |
| 2 | 2₹56.8 L+₹7.5 L (15.3%)Rejected-Finance | 2 | Rejected-Finance L-2 | |
| 3 | 3₹57.5 L+₹8.3 L (16.8%)Rejected-Finance | 3 | Rejected-Finance L-3 | |
| 4 | 4₹61.2 L+₹12.0 L (24.5%)Rejected-Finance | 4 | Rejected-Finance L-4 | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹61.9 L
EMD Value
₹93,950
Closing Date
4 Apr 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
JSV Division Jubbal
Providing LWS to village Badruni Jakrari in GP Parali Kotkhai Tehsil Kotkhai Distt Shimla HP
2023_HPIPH_71445_1
JBL-SML-09-718
Open Tender
Civil Works
Item Rate
365 days
Kotkhai
Please refer Tender documents.
10 documents required · 10 mandatory
₹800
₹93,950
Yes
19 Oct 2023
23 Mar 2023
4 Apr 2023
23 Mar 2023
4 Apr 2023
23 Mar 2023
Amount
Excavation in foundations , trenches etc., in earth work , lift up to 1.50 metres. Stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15 cm. (fifteen centimetres) layers , when required in to plinth and sides of foundations etc., conslolidating each of the disposited layer by ramming and watering and then disposing off all excavated soil as directed with in the load of 20 mtrs. Pick and Jumper work etc. complete as per the direction of the Engineer - in - Charge.
Providing and laying cement concrete 1:3:6 (1cement: 3 sand: 6 graded stone aggregate 40mm( Forty millimeter nominal size) and curing complete excluding cost of from work in foundation and plinth with in all leads & lifts as per entire satisfication of Engineer-In-Charge.
Providing and laying cement concrete 1:1:2 (1cement :1Sand: 2 graded stone aggregate 20 mm N/S) and curing complete excluding cost of form work and reinforcement for Rainforced concrete work in:
Foundation and Plinth with in all leads and lifts as per the direction of the Engineer in Charge.
Walls (Any thickness) attached pillasters, pillasters, buttresses, beam girder and contilevers upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge.
Providing and laying cement concrete work 1:1.5:3 (1cement :1.5 sand: 3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcment for reinforcement concrete work in Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
Providing mild steel/ tor steel reinfircement for rainforced concrete work I/C bending, binding and placing in position complete upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge.
Providing and placing horizontal layers filtering media duly graded screened washed and cleaned as specified by the Engineer Incharge with in all leads and lifts.
Broken Stone 50mm to 75mm
Bajri 20mm to 25mm
Bajri 6mm to 20mm
Coarse Sand 3 mm to 6 mm
Fine Sand 0.20mm to0.40 mm & uniformity 3.00
First class brick flooring laid dry and gruted with cement mortor 1:4 (1 cement : 4 sand) i/c finishing the joints flush 10 cm thick with in all leads and lifts and per direction of the Engineer-in-charge.
Providing and Fixing (M.S. Sheet & Angle Iron) 600x600 mm size man hole cover with frame and controling chaber for wheel valve complete in all respects including locking arrangements etc. (not less than 58 Kg) within all leads and lifts and as directed by the Engineer-in-charge.
Laying and fixing of G.I pipe of 50 mm dia for interconnection of filter bed tank within all leads and lifts.
Providing and laying cement concrete 1:4:8 (1cement: 4 sand: 8 graded stone aggregate 40mm (Forty millimeter nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads & lifts as per direction of Engineer - in charge.
Providing & Laying cement concrete 1:6:12(1ccement :6 sand: 12 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts as per the directions of the Engineer in charge.
Providing and laying cement concrete 1:2:4 (1cement :2 Sand: 4 graded stone aggregate 20 mm (Twenty millimeter nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in :
Foundation and Plinth with in all leads and lifts as per the direction of the Engineer in Charge.
Column, pillar & post upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge.
Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
Stair cases (except spiral stair cases) excluding landing I/c preparation of surfaces with in all leads and lifts as per the direction of the Engineer in Charge.
Providing from work steel plates 3.15 mm thick welded with angle iron in frame 30x30x5 mm so as to give a fair finish i/c centering, shuttering, strutting and propping etc. with wooded battens & ballies, height of propping and centring below supporting floor to ceilling not exceeding 4 meters and removal of the same for in situ reinforced concrete and plain concrete work with in all leads aand lifts as per the direction of the Engineer in Charge.
Foundation and Plinth with in all leads and lifts as per the direction of the Engineer in Charge.
Column, pillar & post upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge.
Beams, cantilever Girders& lintals sides&soffits of beams, beams,haunching cantilever girders not exceeding 1mtr. Depth.
Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttress, plinth and string couress and the like.
Flat surfaces such as soffits and suspended floors, roofs landing and the like: Floors etc up to 200 mm in thickness .
Slopping and battering surfaces I/c folding plates where inclination to horizontal plane not exceeding 30 degrees.
Edges of slab and breaks in floors and walls under 20cm. Wide with in all leads and lifts as per the direction of the Engineer - in - Charge.
Stair cases (except spiral stair cases) excluding landing I/c preparation of surfaces with in all leads and lifts as per the direction of the Engineer in Charge.
Half Brick masonary using common burnt clay building bricks above plinth upto floor two level in cm 1:4(1cement: 4sand)conventiohal brick first class within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing pressed steel door, frames, manufactured from comercial mild steel sheet of 1.25 mm thickness including hinges jump block Jamb, beed, and if required angle threshold of mil steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or regidly fixed together by machanical means adjustable lugs with split and tails to each Jamb i/c steel but things 2.5mm thick with guards lock strike plate and shock as specified and applying a coat of applying steel primer after pretreatment of the surfaces directed by the Engineer-in-charge
Profile - A
Profile - B
Profile - C
Providing and fixing Pannelled and glazed shutters for doors windows and clear storey windows including bright finish black enamel led iron butt hinges with necessary screws 50mm thick: 2nd class deodar wood.
P/F wire gause shutters using MS wire gause of IS gause designation 85 G for doors windows clerestorey windows I/c bright finished black enamelled iron hinges with necessary secrews 40 mm thick 2nd class deodar wood.
15 mm thick cement plaster on fair sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)
20 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)
6 mm thick cement plaster in CM 1:3( 1cement 3 sand in roof slabs
White washing with lime on undecorated wall surfaces two coats to give an even shade including throughly brooming the surface to remove all dirt dust mortar dirt and other foreign matter.
Distempering (two coats) with oil bond distemper of approved brand and manufacture and of required shade on undecorated surfaceto give an even shade and including priming coat with distemper after throughly brushing the surface free from mortar dropping and other foreign matters.
Finishing wall with water profing cement paint of approved brand and manufacture and of rerquired shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials.
Precastterrazo tiles compressed 20 mm thick with marble chips of specified size laid in floors treads of steps and landings on a bed of 25 mm average thickness of cement mortor 1:6 jointed with neat cement slury mixed with pigment to match the shade of tiles (wherever required) including rubbing & polishing with tiles of folowing Shade: Silver Gray
Precast terrazo tiles 20m thick (with marble chipsof specified size) In Skirting & riser ofsteps not exceeding 30cm in height on 10mm thick cement plaster 1:3 (1cement:3sand) and jointed with white slurry. Selvary grey
Applying priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil grease & dirt and other foreigm matter
Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters other than white paint
Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters other than white paint
Providing and fixing of MS grill of required patttern in wooden frame of window etc. with MS rounded headed bolts and nuts or by screw: Plain Grill.
Stone soling properly hand packed filling interstices with spalls and consolidating with power road roller to the required gradient and camber including spreading watering and rolling of binding materials moorum or earth etc. 100mm spread thickness (finished work including materials and labour) within all leads and lifts an da directed by the Engineer-in-charge.
Providing and fixing bright finished brass sliding door bolt with nut and screws complete. 250mm x 16mm
Providing and fixing Anodized aluminium tower bolts withnuts and screws complete.
200mm x 10mm
100mm x 10mm
Providing and fixing Anodized aluminium handle withnuts and screws complete.
125 mm dia.
100 mm dia.
Providing 40x3 mm flat iron hold fast 40cm. Long including fixing to frame with 10mm dia metres bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm. 1:3:6( 1cement:3sand:6 graded stone att. 20mm nominal size) within all leads and lifts and as directed by the Engineer-in-charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6graded stone agg. 20mm nominal size) i/c finishing the top surface of concrete smooth within all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying brick tiles over mumty roofs grouted with cement mortar 1:3 over a 12mm layer of cement mortar 1:3 and finished needly within all leads and lifts and as directed by the Engineer-in-charge.
Steel work welded in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of red lead paint etc. with in all leads and lifts as per the direction of the Engineer in charge.
Cutting in earth work in all classification of earth work such as pick work, jumper work, saturated soil, in all lifts including trimming and dressing of sides, levelling of beds where ever required, and stacking the usable/ serviceable materials/soil separately complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Pick Work
Jumper Work
Steel work in single sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint in R.S. Joists,channels, angles, tees etc. with in all leads and lifts as directed by the Engineer Incharge
Providing, laying, testing & commissioning at site in trenches bevelled ended BIS marked API pipes confirming to IS-1978-1982 ISO- 3183-2007 or its equivalent latest with up to date ammendments of following dia with steel grade Yst -240, having wall thickness as mentioned below & capable of withstanding required test pressure as prescribed in BIS/ISO code, in random lengths of 5.5 to 6.5 mtr. The pipe's ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable ends with up to date ammendments (leak proof) in three layers at site of work with welding rods of standard make & all allied accessories whatever required for welding at site, tail pieces, tees, bends & other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions. and cutting of pipes wherever required as per site requirement i/c carriage in all leads & lifts and as directed by Engineer-Incharge. The pipe shall have's zinc coating inside & outside confirming to IS-4736-1986 or latest with up to date ammendments & shall be engraved with Yst-210, code IS-3183-2007 or its equivalent . The laying shall confirm to BIS 5822-1970 or latest with up to date ammendments to the entire satisfaction of Engineer-Incharge (Earth work & cost of MS flanges after 100 meter length shall be measured & paid for seperately).
65 mm dia Wall Thickness 4.80mm Flange Table 28 X42 or L290
65 mm dia Wall Thickness 4.80mm Flange Table 17 X42 or L290
Providing laying jointing and testing of GMS pipe conforming to IS 1239-1991(part-I) of various thickness as mentioned and grade designation with bevelled edge and capable of withstanding required testing pressure in random length of 5.5-65 meters i/c testing and commissioning and cost of jointing with buttwelding as per revant BIS specification ( leak proof) including cost of bends tail pieces, tees reducers increasers etc. as per site requirement and as per directio of the Engineer-in-charge, earth work in trencher to be measured and paid for separately i/c all leads lifts and carriage of materials at site.
65 mm dia G.I Heavy Wall Thickness 4.80mm Flange Table 28
65 mm dia G.I Heavy Wall Thickness 4.80mm Flange Table 17
65 mm dia G.I Medium Wall Thickness 4.80mm Flange Table 5
Providing, welding and fixing M.S. plate flanges of various dia (nominal bore) of following Flange Tables confirming to IS 6392-1971 or latest with up to date ammendments to ERW after 100 mtr. pipe or as per site requirement including cutting of of pipes wherever required, welding in three layers (leak proof) confirming to specifications as prescribed in relvent I.S. Code i.e. IS 816-1969 with electrode as per IS: 814-1991 or latest as applicable with up to date ammendments with nuts, bolts & washers & specials etc. confirming to IS-1963 or latest with up to date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorosive paints complete in all respect in all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
65 mm dia Wall Thickness 4.80mm Flange Table 34
65 mm dia Wall Thickness 4.80mm Flange Table 28
65 mm dia Wall Thickness 4.80mm Flange Table 17
65 mm dia Wall Thickness 4.80mm Flange Table 5
Laying , jointing and testing in trenches Galvanised Mild Steel tube of the following dia metres including smooth bending by necessary bends, or through pipe bending machine with necessary all pipe fittings such as Tees, Elbows, Union & Reducers etc. of ISI marked & testing for leakage complete with in all leads & lifts as per entire satisfication of Engineer - in - charge. (Earth work in trenches to be measured and paid for separately)
15 mm dia
20 mm dia
32 mm dia.
Providing and replacing of copper alloy gate valve (Heavy duty) ISI marked with in all leads and lifts as per the direction of Engineer-in-Charge.
15 mm dia
20 mm dia
32 mm dia.
Supply & fixing galvanised steel bar-bed wire (IS 278-1962 Type -1 ) weighing 9.38 kg per 100 mtr. Min. staining & fixing to any type of standard rails straining bolts i/c securing with & provision of gavanised mild steel wire staples or steel pins etc. with in all leads & lifts as directed by Engineer in-charge.
Pumping Machinery. Providing horizontal spindle,horizontal/redial split casing/and suction(Back-full out arrangements single/double/multi stage centrifugal pump or combination of pumps. In series/parallel of recommended make such as Mather and Platt/KSB/Beacon Weir/Kirlosker/BE/Jyoti as per BIS 1520-1980 with upto date ammend-ments read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor/motors of standard make such as Kirlosker/BHEL/Crompton/NGEF/GEC/Siemens/Jyoti and suitable for operation on 400(+/-) 0% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts bolts and painting etc. and should meet the following requirements. One set is act as Standby. A) Pumps Specification: i. Make ii. Modal iii. No. of stages iv. Material (Manufacturers performance appended) i. head ii. Discharge (Q) iii. BHP observed iv. Efficiency v. NPSH B. Motor: i. Make ii. Modal iii. Motor rating (KW) iv. Speed v. Insulation Coupling Base Plate.
i) Discharge (Q) 3.11 LPS each pump. ii)Total dynamic head 429.59 Mtr. a)LWL in sump well(h) 1998.17 Mtr. b) Shaft level 1998.17 Mtr. c) Level at discharge point 2386.00 Mtr. d) suction lift (+) head 3.00 mtr. e)Discharge head 3.00 mtr. f) Static head 387.83 Mtr. iii)Raising main a) Length 1500 Rmt. b) Dia. 65 mm iv)Pumping hours 4 Hrs. v) Altitude of installation above MSL 2245 mtr. a) Temperature 0C b) Ambient temp 0C c) Turbiduty JTU d) Alkalanity e) Size of the solids NIL mm f) others
Providing and fixing ICTP main switch with HRC fuses of Kilburn/L&T/Seimen/Standred/Havells make and having capacity 30% extra of the operationl rating/as per IS-4064-1978 with up to date ammendments immediately after the power meter of the HPSEB. ICTP Switch Make Type Capacity.
Providing & fixing M.S sheet,steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40*40*6, duly painted with steel sheet of 16 guage comprising and capable of mounting the following accessories with all internal connections. Panel/Switch board Drawings Layout plan.
i) MCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments. MCB/MCCB Make Type Range Capacity.
Earth leakage circuit breaker of recommonded make L&T/MEI/GEC as per IS:2516- 1977 with upto date ammendements and of suitable range which should have control box,operating,handle and trip/reset bush button on/off indicators re-indicating off spring condition of the circuit breaker for over current protection. The cicuit should be equipped with magnet thermal release with matallic tape CST, it should be fitted with earth fault for tripping of breaker on occurance of earth fault on off breaker load side and suitable for above motor and the voltage meter relay 3 phase with all protection and usual indicators and electrid siran against single phasing, low voltage,reverse phasing,over loading and phase voltage difference as per IS:3842(latest edition) ELCB Make Type Range
(III) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition) Volt meter relay Make Type Range
100 mm diameter circular dial A.C. supply volt meter of recommended make AE/IMP/ Havells of suitable range with slector switches as per IS:4064-1978 with uptodate ammendements. Volt meter Make Type Range:
Digital power factor mtr of standard make as per relevent IS code with upto date ammendements. Power Fector Meter Type Make
Digital frequency mtr of standerd make as per relevent IS code with upto date ammendements. Frequency Meter Make Type Range
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for netural phase as per IS:8084-1976 and IS:11353-1985 read with BIS-5578-with uptodate ammendments.
ICTPswitches with HRC fuses of Kulburn/L&T/Siemens/Standered/Havells make and of suitable capacity as per IS:4064-1978 with up to date ammendments. ICTP Switches Make Capacity
Three phase indicator lamps complete with toggie switches for individual motors as per per IS:3452(P_I&II) with up to date ammendements. Three phase indicator Make Capacity
Capacitor of Mecheil/BHEL/GEC/L&Tmake as per IS2834-1986 with up to date ammendements,to raise the power factorat site to 0.95 for direct connection to induction motor individuaily of required KVA rating according to H.P offered including cables as per relevent ISI code(of Siemens/Ciocter/ IEC make0 from busbar chamber to capacitor and also including ICTP switches of appropriate up date ammendements. Capacitor Make Range
P/fixing suitable oil immersed Star Delta strarter L&T/Siemensmake as per IS:8544-1979 with up to date ammendements for squirrel cage/ slip ring motor mounted on panel board with magnetic type over load release and dashpot pot, time lag under voltage release with or with out initial oil filling as the case may be with single phase preventer as per IS:1248(P-V)-1983 with up to date ammendements. Single Type: Make:
Digital hours run meter of reputed make.
Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.
Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar make and equal to dia of suction pipe and cpable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments. Sluice valve: Size Make Material Seat pressure.
Providng double flanged cast iron sluice valves PN-I of leader/BHEL Kirlosker/Kilburn GLED/fourses/ Kartar make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements. Sluice valve: Size Make Material Seat pressure.
Providing double flanged swing type cast iron valve, PN-I of Leader/BHEL/Kirlosker/Kilburn/GLEd/Fourses/ Kartar make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments) Sluice valve: Size Make Material Seat pressure.
Providing double flanged cast iron reflux valves class PN-I of Leader/BHEL/KILROSKER/Kartar/KILBURN/GLED/FOURSES/ Kartar make and of 350 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments. Reflux valve: Size Make Material Seat pressure.
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig/Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments. Pressure gauge Make Range.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments. Discharge meter: Make Type Range.
Installation of all the items apparing at serial No.1 to 9 as per the systematic drawing.
Providing and fixing double flanged API pipe work (Layout to be approved by the Engineer -incharge of work for suction and delivery pipe suitable for pump(s) offered and common header as per the R/main respectively complete with all specials such as bends,tees,reducers,increasers with conpanion flanges mating with the relevent spectifications of the accessories as indicated in the drawing no 2 including rubber/asbestos gasket of minium 3mm thickness as per IS:2712-1979 and required no,s of nuts and bolts as per IS1364-1983. the pipe shall be as per relevent IS code and to with stand 1.5 times total head stipulated under item No.1 the size of the various components to be as under:- I)Suction pipe mm dia II)Delivery pipe mm dia III)Common header mm dia and will be extendewd up to 5mtrs from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable (one vable carrying all the three phases) of suitable size and capacity to motors and all other electrical equipments as per IS:1554 (P-I) 1988 or latest with up to date ammend ements of siemens/Gloster/IEC/ICC/ EICO/National/GRANDLY make including all other accessories such as thimbles,flexible pipes, solder,nuts and bolts,vable glands etc. laid in pipes or trenches under floor. Armored power cable Motor side (from switch to starter and starter to motor) Size Make Type Core Supply side(From meter of HPSEB to bus bar Size Make Type Core
NAKUL DHILLON
Arpit Singh Rathore
HEM LATA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .