GEMC-511687744663474
Awarded to gental enterprises
₹1.3 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| ILTT20048 12V 160AH BATTERY | LUMINOUS INVERLAST ILTT20048 | - | 8 NOS | ₹16,250 | 130,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹1.5 L+₹17,008 (13.1%)Qualified Make: LUMINOUS
Model: LUMINOUS INVERLAST ILTT20048 2 175 RUCHI KHAND 2 LDA COLONY LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | Make: LUMINOUS
Model: LUMINOUS INVERLAST ILTT20048 | L2 | Qualified | |
| 2 | Qualified Make: EXIDE
Model: EXIDE 6EL160 2 175 HARSHIT SALES 2 175 RUCHI KHAND 2 98899 LUCKNOW UTTAR PRADESH 226002 | LUCKNOW | UTTAR PRADESH | 226002 | Make: EXIDE
Model: EXIDE 6EL160 | - | Qualified | |
| 3 | L1₹1.3 LDisqualified Make: LUMINOUS
Model: luminous ILTT20048 MB 11A MANSAROVER COMPLEX HOSHANGABAD ROAD BHOPAL MADHYA PRADESH 462003 | BHOPAL | MADHYA PRADESH | 462003 | Make: LUMINOUS
Model: luminous ILTT20048 | L1 | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
5 Oct 2018, 3:00 pmClosed
lead acid battery Average Turn Over of Last 3 Years 6 Lakh (s) Experience with Gov. Required 2 Year (s) Lead Acid Battery ( 8 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Stationary cells and Batteries
Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 Stationary cells and Batteries
Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 160 160 Warranty (Years) 4 Years 4 Years Battery Condition Dry Charged * CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications * Volume of Electrolyte (ml) 75 * 1/3 Weight of Dry Battery (Kg) shall be as per relevant IS: Specn.
corresponding Ah Yes. * No.of cells per Battery (No.) 6 Cells for 12 Volt battery * CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes * Address of the Lab BENGALORE * Name of the Lab CPRI * Test Report No. 12CPRI160B * Test Report Date 01.04.18 * Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells
and for Batteries made from them for use in portable applications YES * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ganesh Narayan Meena 302006
ESIC Model hospital
Laxminagar
Ajmer road
Jaipur 8 15
627082
GEM/2018/B/89017
GeM Contract
lead acid battery
GeM Contract
15 days
Rajasthan; Jaipur
PRODUCT
Awarded to gental enterprises
₹1.3 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| ILTT20048 12V 160AH BATTERY | LUMINOUS INVERLAST ILTT20048 | - | 8 NOS | ₹16,250 | 130,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| lead acid battery Average Turn Over of Last 3 Years 6 Lakh (s) Experience with Gov. Required 2 Year (s) Lead Acid Battery ( 8 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Stationary cells and Batteries | - | - | - |
| Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 Stationary cells and Batteries | - | - | - |
| Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 160 160 Warranty (Years) 4 Years 4 Years Battery Condition Dry Charged * CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications * Volume of Electrolyte (ml) 75 * 1/3 Weight of Dry Battery (Kg) shall be as per relevant IS: Specn. | - | - | - |
| corresponding Ah Yes. * No.of cells per Battery (No.) 6 Cells for 12 Volt battery * CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes * Address of the Lab BENGALORE * Name of the Lab CPRI * Test Report No. 12CPRI160B * Test Report Date 01.04.18 * Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells | - | - | - |
| and for Batteries made from them for use in portable applications YES * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ganesh Narayan Meena 302006 | - | - | - |
| ESIC Model hospital | - | - | - |
| Laxminagar | - | - | - |
| Ajmer road | - | - | - |
| Jaipur 8 15 | - | - | - |
Exempted
8 Oct 2018
18 Sept 2018
contract_GEMC-511687744663474.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_627082.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .