| 1 | L1₹55.5 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹55.5 L Quoted ₹57.0 L | L1 | Accepted-AOC AOC |
| 2 | L2₹63.8 L+₹6.8 L (11.9%)Rejected-Finance NAKARI BORIGAON SIDING JORHAT 785001 ASSAM | JORHAT | JORHAT | ASSAM | 785001 | ₹63.8 L+₹6.8 L (11.9%) | L2 | Rejected-Finance Other than L1 bidder |
| Sl No | Description | Qty | Unit | PURBANCHAL BUILDERS L1 | HEMONTA DAS L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and directed. | 425.5 | CUM | 229 ₹97,439.5 Lowest | 250 ₹1,06,375 |
| 2.00 | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed.
Note :- Only punned down sand shall be measured. | 127.7 | CUM | 799 ₹1,02,032.3 Lowest | 980 ₹1,25,146 |
| 3.00 | Material and labour for Sub class ‘B’ old size well burnt brick laid flat in trenches over the cable for protection of LT cable complete all as specified and directed. | 12.6 | PER 1000 NOS | 11,999 ₹1,51,187.4 Lowest | 12,500 ₹1,57,500 |
| 4.00 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and directed. | 245.6 | CUM | 99 ₹24,314.4 Lowest | 125 ₹30,700 |
| 5.00 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and directed. | 180 | CUM | 229 ₹41,220 Lowest | 250 ₹45,000 |
| 6.00 | Taking out old unserviceable UG cable of size 10-16 Sqmm 2/4 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. | 460 | RM | 19 ₹8,740 Lowest | 25 ₹11,500 |
| 7.00 | Taking out old unserviceable UG cable of size 25-50 Sqmm 3.5 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. | 580 | RM | 19 ₹11,020 Lowest | 30 ₹17,400 |
| 8.00 | Taking out old unserviceable UG cable of size 70-95 Sqmm 3.5 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. | 200 | RM | 29 ₹5,800 Lowest | 35 ₹7,000 |
| 9.00 | Taking out old unserviceable UG cable of size 120-185 Sqmm 3.5 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. | 410 | RM | 39 ₹15,990 Lowest | 40 ₹16,400 |
| 10.00 | Taking out old unserviceable UG cable of size 240-300 Sqmm 3.5 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. | 320 | RM | 49 ₹15,680 | 45 ₹14,400 Lowest |
Tender Value
₹56 L
EMD Value
₹1.1 L
Closing Date
24 Aug 2026, 6:00 pmClosed
CWE SHILLONG
HQ CWE SHILLONG
REPAIR/ MAINT TO OVER HEAD/ UNDER GROUND ELECTRIC SUPPLY LINES AND OTHER ALLIED WORKS SERVICES UNDER GE NARANGI
2026_MES_768873_2
8005/NAR/E8
Open Tender
Civil Works
Item Rate
180 days
Narangi
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE Narangi
₹1.1 L
Yes
18 Sept 2026
29 Jul 2026
26 Aug 2026
29 Jul 2026
24 Aug 2026
5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and directed. | 425.5 | CUM | - | - |
| 2 | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed.
Note :- Only punned down sand shall be measured. | 127.7 | CUM | - | - |
| 3 | Material and labour for Sub class ‘B’ old size well burnt brick laid flat in trenches over the cable for protection of LT cable complete all as specified and directed. | 12.6 | PER 1000 NOS | - | - |
| 4 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and directed. | 245.6 | CUM | - | - |
| 5 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and directed. | 180 | CUM | - | - |
| 6 | Taking out old unserviceable UG cable of size 10-16 Sqmm 2/4 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. | 460 | RM | - | - |
| 7 | Taking out old unserviceable UG cable of size 25-50 Sqmm 3.5 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. | 580 | RM | - | - |
| 8 | Taking out old unserviceable UG cable of size 70-95 Sqmm 3.5 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. | 200 | RM | - | - |
| 9 | Taking out old unserviceable UG cable of size 120-185 Sqmm 3.5 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. | 410 | RM | - | - |
| 10 | Taking out old unserviceable UG cable of size 240-300 Sqmm 3.5 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. | 320 | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
BOQ_875543.xls
BOQ • 0.32 MB
8005TENDER2.pdf
Tender Documents • 0.85 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .