| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.7 LAccepted-AOC 6 341 RATAN VIHAR NANGLOI DELHI 110041 | DELHI | WEST DELHI | DELHI | 110041 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹24.8 L+₹5.0 L (25.0%)Rejected-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹25.8 L+₹5.9 L (29.8%)Rejected-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹26.3 L+₹6.5 L (32.5%)Rejected-AOC | L-4 | Rejected-AOC L-4 | |
| 5 | L-5₹26.6 L+₹6.7 L (33.9%)Rejected-AOC B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L-5 | Rejected-AOC L-5 |
Tender Value
Refer Docs
EMD Value
₹86,500
Closing Date
21 Jan 2023, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINT OF ALL TYPES OF DG SET, AMF PANEL AND OTHER CONNECTED WORKS IN METCALFE HOUSE AND JCB LAB UNDER GE I RND DELHI
2022_MES_570296_1
GE/RND-92/DLI/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D, cat-b(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹86,500
Yes
25 Feb 2023
20 Dec 2022
23 Jan 2023
20 Dec 2022
21 Jan 2023
9 Jan 2023
Amount
M&L for B check general servicing by authorised representative of manufacturer of DG set of capacity 125 KVA, replacement of oil filter, fuel filter, air filter, by pass filter cleaning of radiator with chemical after draining out engine/ lubrication oil, coolant flushing and cleaning of oil chamber after opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment refixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasket at the servicing and other work comes under B Check service as mentioned in B Check by the manufacturer complete all as specified and directed. Note:- Engine oil & Coolant will be paid separately under respective item.
All as per item Ser No 1.00 above but of capacity of DG set 180 KVA.
All as per item Ser No 1.00 above but of capacity of DG set 200 KVA.
All as per item Ser No 1.00 above but of capacity of DG set 250 KVA.
All as per item Ser No 1.00 above but of capacity of DG set 300 KVA.
All as per item Ser No 1.00 above but of capacity of DG set 380 KVA.
All as per item Ser No 1.00 above but of capacity of DG set 750 KVA.
M&L for repair of self starter 12 V including rewinding of armature with super enamelled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon bush including services suitable for DG set 62.5 to 125 KVA complete all as specified and directed.
M&L for repair of self starter 24 V including rewinding of armature with super enamelled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon bush including services suitable for DG set upto 750 KVA complete all as specified and directed.
S&F in replacement of automatic battery charger with auto cut OFF suitable for 2X12V 180AH batteries with all required necessary wiring complete all as specified and directed.
M&L for replacement of complete wiring to AMF panel for any capacity of DG set including interlock system of AMF panel with existing size of copper wiring including proper connection and testing complete all as specified and directed.
S&F in replacement of self starter 24 volts suitable for upto 750 KVA DG sets complete all as specified and directed.
S&F in replacement of battery brass terminals heavy duty suitable for 12V 180 AH battery with minimum 2 RM Battery Lead of copper cable single core complete all as specified and directed.
S&F in replacement of relay 24 V 8 pin type as per matching to existing and properly connection and testing after completion complete all as specified and directed.
S&F in replacement of engine starting relay suitable for DG set of capacity upto 125 KVA as per matching to existing complete all as specified and directed.
S&F in replacement of engine starting relay suitable for DG set of capacity 200 to 750 KVA as per matching to existing complete all as specified and directed.
S&F in replacement of Electronic timer suitable for AMF panel of DG set as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed.
S&F in replcement of Voltmeter analog type for voltage range of (0-24V) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
S&F in replacement of Voltmeter analog type for voltage range of (0-500V) complete with all accessories and wiring complete all as specified and directed.
S&F in replacement of Ammeter analog type for current range of (0-24Amps) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
S&F in replcement of Ammeter analog type for current range of (0-1000Amps) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
S&F in replacement of power contactor ML 6 suitable for AMF panel of DG set as per matching to existing complete all as specified and directed.
S&F in replacement of power contactor ML 4 suitable for AMF panel of DG set as per matching to existing complete all as specified and directed.
S&F in replacement of power contactor ML 3 suitable for AMF panel of DG set as per matching to existing complete all as specified and directed.
S&F in replacement of power contactor ML 2 suitable for AMF panel of DG set as per matching to existing complete all as specified and directed.
S&F in replacement of under voltage relay suitable for DG set upto 380 KVA complete all as specified and directed.
Supply and Fix in replacement of complete wiring with single core 2.50 Sqmm multistranded copper cable with flexible conduit 15mm dia for DG set of various capacities complete all as specified and directed.
S&F and testing Electronic Governor Controller for 200 to 750 KVA DG Set including taking down old Governor Controller complete all as specified and directed.
Taking down the old unserviceable actuator from its position and S&F new actuator for upto 750 KVA DG set complete all as specified and directed.
Opening the DG set of 200 to 380 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing all flexible/steel wire mesh type hose pipes including fuel pipe line, belts & bearings and including re-assembling the same and testing complete all as specified and directed. Note :- Spare parts required for replacement shall be measured & paid under following item.
Supply only Piston ring and liner for 200 to 380 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Head valve, Head Guide, Head sheet & Head seal for 200 to 380 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Injector sleeves & Head gasket for 200 to 380 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Packing Kit for 200 to 380 KVA DG Set as per existing make & OEM complete all as specified and directed.
M&L for repair of Head and fuel injector assembly complete for 200 to 380 KVA complete all as specified and directed.
M&L for repair of Turbo assembly complete for 200 to 380 KVA complete all as specified and directed.
Opening the DG set of 750 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing all flexible/steel wire mesh type hose pipes including fuel pipe line, belts & bearings including re-assembling the same and testing complete all as specified and directed. Note :- Spare parts required for replacement shall be measured & paid under following item.
supply only Piston ring and liner for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Head valve, Head Guide, Head sheet & Head seal for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Injector sleeves & Head gasket for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Packing Kit for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
M&L for repair of Head and fuel injector assembly complete for 750 KVA complete all as specified and directed.
M&L for repair of Turbo assembly complete for 750 KVA complete all as specified and directed.
Taking down the old unserviceable fan belt and Supply and Fix Fan belt of existing size for DG Set of capacity 125 to 200 KVA complete all as specified and directed.
Taking down the old unserviceable fan belt and Supply and Fix Fan belt of existing size for DG Set of capacity 250 to 380 KVA complete all as specified and directed.
Taking down the old unserviceable fan belt and Supply and Fix Fan belt of existing size for DG Set of capacity 750 KVA complete all as specified and directed.
Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifold for DG set 300 KVA including removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
S&F in replacement fly wheel ring of DG set of capacity 125 KVA complete all as specified and directed
S&F in replacement fly wheel ring of DG set of capacity 200 to 380 KVA complete all as specified and directed
Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 125 to 200 KVA complete all as specified and directed
All as per item Ser No 39.00 above but 250 KVA.
All as per item Ser No 39.00 above but 300 to 750 KVA.
S&F in replacement of Changeover switch on load front operated 300 Amps 4 Pole 415 volt complete including properly connecting incoming and outgoing cable and testing after completion complete all as specified and directed
M&L for repair to radiator of 125 to 200 KVA DG set, arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed. Note :- Necessary coolant and distilled water required will be measured and paid seperately.
All as per item Ser No 43.00 above but 250 to 380 KVA.
M&L in replacement lead acid battery of size 12 Volt, 180 AH including charging complete all as specified directed.
Removing old unserviceable insulating material asbestos rope and fixing of new asbestos rope of existing size and shape complete all as specified and directed.
M&L for Spray painting of diesel generating set of capacity 125 to 200 KVA of accostic enclosure/open type with one coat of synthetic enamel paint, body colour shall be apple green, black for foundation base frame, red for all guards including preparing old surfaces complete all as specified and directed.
All as per item Ser No 47.00 above but 250 KVA.
All as per item Ser No 47.00 above but 300 KVA to 750 KVA.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) for foundation of pole complete all as specified and directed.
S&F in replacement of 3 Pole MCCB, 630 Amp, 50 Hz, 415 V 36 KA rupturing capacity with microprosseor release and adjustable overload setting complete all as specified and directed.
S&F in repair MCCB 125 Amps 3 pole breaking capacity 35 KA complete all as specified and directed
All as per item Ser No 52.00 above but 100 Amp 3 pole 25 KA.
All as per item Ser No 52.00 above but 250 Amp 3 pole 25 KA.
All as per item Ser No 52.00 above but 200 Amp 3 pole 25 KA.
S&F in repair MCCB 630 Amps 4 pole breaking capacity 50 KA complete all as specified and directed.
S&F in repair MCCB 400 Amps 4 pole breaking capacity 36 KA complete all as specified and directed.
S&F in repair MCCB 250 Amps 4 pole breaking capacity 36 KA complete all as specified and directed.
Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron earth wire 4.00 mm dia by means of Copper nuts, bolts and washers. GI wire shall be laid in 20 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI wire of 4 mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
M&L for earth continuity conductor main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 4 mm galvanised iron wire complete all as specified and directed.
Supply and laying in replacement GI pipe light grade of 50mm dia including new fittings laid in trenches or under road crossing for protection of UG cable complete all as specified and directed
All as per item Ser No 61.00 above but 80mm dia.
M&L for boring of holes under road, pavement, hard standing etc by trenchless techonology using ultra sound technique/mannually/mechanically and necessary machine including supply and laying of 100mm dia GI pipe light grade complete all as specified and directed.
S&F in repair alternator of DG Set of capacity upto 200 KVA complete including rewinding & replacement of connected items such as bearing, sleeves Nut bolts, coupling etc complete all as specified and directed.
All as per item Ser No 64.00 above but of capacity 300 KVA.
S&F earth pit chamber alongwith cover of Polymer, FRP Pit Cover of heavy high grade polypropelene for high stress and starin level of size 225x300x 195 mm complete all as specified and directed.
S&F in replacement ACP retro sign board of size 1.5 x 1.1 Mtr using retro reflective high intensity prismatic reflective sheeting. The back ground of board is blue colour with white border and writing letter, numbers white colour mentioning the DG Set substation details, and single line schematic diagram of substation. Retro sign board shall be pasted on 3 mm thick ACP sheet. The board shall be fixed on Wall including fixing of fastners, nuts, bolts, washer etc complete all as specified and directed.
M&L in repair 6mm thick MS chequered plate of suitable size for cable duct cover and earth pit cover complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for protection of cable duct including for taking out and relaying of LT Cables etc complete all as specified and as directed.
Returning, filling in including spreading, levelling watering and well ramming in layers not exceeding 25cm thick in soft/loose complete all as specified and directed.
Removing surplus excavated materials to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
M&L for burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and laying clean dry river sand in trenches, ducts including leveling, punning for cushioning of cables complete all as specified and directed. Note : Punned thickness of sand cushioning shall be measured (8 cm below the cable & 15 cm above the cable).
Supply and laying in trenches, fixed to wall/pole/tray etc UG cable XLPE insulated armoured heavy duty electric UG cable with aluminum conductor 1100 volts grade of cross sectional area of following size including taking out old unserviceable cable complete all as specified and directed :-
10 Sqmm 2 Core
16 Sqmm 4 Core
25 Sqm 3.5 Core
35 Sqm 3.5 Core
120 Sqm 3.5 Core
240 Sqm 3.5 Core
M&L in replacement of GI bracket made out of 40 mm medium grade GI pipe bend to shape approx 1.2 mtr length including clamp, nut, bolt, washer etc complete for fixing of street light complete all as specified and directed.
S&F in replacement Junction box SMC KIOSK box water proof of size 140x140x95 mm including fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specified and directed.
All as per item Ser No 77.00 above but 300x200x125mm.
S&F in replacement copper cable 2.5 Sqm 3 core PVC sheathed multi core for connection of street light inserting from top in side the pole and connecting in junction box complete including making Hole in Pole as per site complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) for coping around pole complete all as specified and directed.
S&F LED Post Top Lantern 25W wall luminaire with diffuser and painted spun aluminium deflector including taking down old unserviceable post top lantern complete all as specified and directed.
S&F in replacement of LED Post Top bollard light 10 W including necessary excavation and PCC work for fixing complete all as specified and directed.
S&F powder coated pressure die cast aluminium SMD LED street light with heat resistant toughened glass of capacity 45 Watt including taking down old unserviceable street light complete all as specified and directed.
S&F powder coated pressure die cast aluminium SMD LED street light with heat resistant toughened glass of capacity 70 Watt including taking down old unserviceable street light complete all as specified and directed.
All as per item Ser No 84.00 above but of capacity 90 Watt.
All as per item Ser No 84.00 above but of capacity 120 Watt.
S&F LED flood light with pressure die cast aluminium housing 100 Watt with connection including taking down old unserviceable flood light complete all as specified and directed.
All as per item Ser No 87.00 above but 150 Watt.
All as per item Ser No 87.00 above but 200 Watt.
S&F in replacement of driver for 45 W LED street light fitting complete all as specified and directed.
All as per item Ser No 90.00 above but 75 W.
All as per item Ser No 90.00 above but 100W.
All as per item Ser No 90.00 above but 150W.
S&F LED flood light 250 watt with pressure die cast aluminium housing complete with all accessories including taking down old unserviceable flood light complete all as specified and directed.
S&F in replacement of GI pipe light grade 50 mm dia for laying of protection of UG cable complete all as specified and directed.
S&F in replacement of GI pipe light grade 40mm dia for laying of protection of UG cable complete all as specified and directed.
Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
M&L in replacement Earth continuity conductor or main earthing lead of size 25 x 4 mm (GI strip) fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc complete all as specified and directed.
S&F in replacement of timer switch astronomical type, 415 Volt three Phase of 63 Amps rating with Three Pole ML-4 contactor including one toggle switch for auto, off and Manual function and incomming MCB TP internally pre wired complete and fitted inside steel enclosure all as per site requirement complete all as specified and directed.
S&F service cable 1100 volts grade heavy duty PVC insulated aluminium multistranded conductor served with inner sheathing of size 10 Sqmm 2 Core complete including taking down of old unserviceable cable complete all as specified and directed.
M&L for servicing of AMF panel of any size/make, check all loose connections of end terminals, screws, nuts, bolts thimbles, clean all electric/electronic parts by using CRC spray, check contactors connections and its serviceability, check all relay setting of AMF panel and check all internal connections of AMF Panel and hinges and locking devices complete all as specified and directed.
M&L for preparation of new steel or iron surface over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Pradeep Bros
SNOWY ENGINEERING INC
V.V CONSTRUCTIONS
HONEY COLLECTION
V M CONSTRUCTION
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .