| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹10.1 L+₹9,325 (0.94%)Rejected-Finance | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹10.1 L+₹13,796.50 (1.38%)Rejected-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹10.2 L+₹24,576.50 (2.47%)Rejected-Finance | L4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L5₹10.3 L+₹34,288 (3.44%)Rejected-Finance | L5 | Rejected-Finance BEING L5 BIDDER |
Tender Value
₹9.3 L
EMD Value
₹18,600
Closing Date
27 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I DARJEELING
AGE I DARJEELING JALAPAHAR CANT DIST - DARJEELING
REPAIR/REPLACEMENT OF EXTERNAL WATER SUPPLY SYSTEM, CLEANING OF WATER RESERVOIRS AND ALLIED WORKS AT LEBONG UNDER AGE I DARJEELING
2023_MES_600039_1
9071/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
LEBONG
AS PER NIT
7 documents required · 7 mandatory
₹500
AGE I DARJEELING
₹18,600
Yes
30 Jun 2023
1 Jun 2023
28 Jun 2023
1 Jun 2023
27 Jun 2023
15 Jun 2023
Amount
M&L for cleaning of Semi-undeground RCC sump of capacity 50000 gallons at lebong by following methods.- (a) Draining out reserved water by opening drain out valve/ dewatering system. (b) Removing all scale, dirt, mud inside the tank by using TERBACK G10 Chemical and scrubbing the wall of tank. (c) Cleaning indide surfaces of the tank with fresh water by high speed jet pump. (d) First bacteria screening for sterilisation by using TERBACK G5. (e) Cleaning the floor of the water tank by heavy duty industrial vaccun cleaner. (f) Second bacteria screening for sterilisation by using UV rays. (g) Third bacteria screening for sterilisation by using TERBACK G65. Note: (i) On completion sterilisation certificate to be submitted to the Engg-in-Charge. (ii) Re-writing the letter not exceeding 25 cm in high as 'Tank cleaned on indicating date,month and year of cleaning with synthetic enamel paint white in colour on black background. (iii) The quoted unit rate is included for removal of mud, grits & deposits etc properly from site of work.
All as per ser item No. 01 above but for capacity of 30000 Gallons, complete all as specified and as directed by Engineer-in-charge.
All as per ser item No. 01 above but for capacity of 25000 Gallons, complete all as specified and as directed by Engineer-in-charge.
All as per ser item No. 01 above but for capacity of 10000 Gallons, complete all as specified and as directed by Engineer-in-charge.
All as per ser item No. 01 above but for capacity of 5000 Gallons, complete all as specified and as directed by Engineer-in-charge.
All as per ser item No. 01 above but for capacity of 200000 Gallons, complete all as specified and as directed by Engineer-in-charge.
All as per ser item No. 01 above but for above ground Steel water tank of capacity 30000 Gallons, complete all as specified and as directed by Engineer-in-charge.
All as per ser item No. 01 above but for above ground Steel water tank of capacity 9000 Gallons, complete all as specified and as directed by Engineer-in-charge.
All as per ser item No. 01 above but for above ground Steel water tank of capacity 5000 Gallons, complete all as specified and as directed by Engineer-in-charge.
All as per ser item No. 01 above but for above ground RCC sump of capacity 4000 Gallons, complete all as specified and as directed by Engineer-in-charge.
All as per ser item No. 01 above but for above ground PVC water tank of capacity 10000 Ltrs, complete all as specified and as directed by Engineer-in-charge.
All as per ser item No. 01 above but for above ground PVC water tank of capacity 5000 Ltrs, complete all as specified and as directed by Engineer-in-charge.
All as per ser item No. 01 above but for above ground PVC water tank of capacity 2000 Ltrs, complete all as specified and as directed by Engineer-in-charge.
M&L for periodical maintanance of Pressure Filter Plant 35 Cum/Hr by dismantling of GI/MS pipe connections, opening manhole and removing/taking out old filter medias i.e. sand, gravels, PVC stainers etc and cleaning serviceable filter media by washing properly removing dirts/muds etc and staking them after segrigation process for refilling in the tank incl replacement of unserviceable PVC stainer as required and refixing pipes, manhole cover etc to existing position using new gasket, tightening of nuts & bolts, washers etc after refilling of serviceable gravells/sand media with new gravells/sand media and disposed off old unserviceable gavels/sand at a distance not less than 100m from site complete all as specified and directed. Note :- (a) PVC strainers shall be paid and measured seperately under relavent item as 'Supply only' here-in-after. (b) Refilling of filter media shall be measured under relavent item here-in-after.
M&L for filling of gravel of size 20mm to 12mm on the filter bed of the pressure filter uniformly after washing/cleaning to remove dust, dirts etc. in layers complete all as specified and as directed by Engineer-in-charge.
M&L for filling of gravel of size 12mm to 06mm on the filter bed of the pressure filter uniformly after washing/cleaning to remove dust, dirts etc. in layerscomplete all as specified and as directed by Engineer-in-charge.
M&L for filling of gravel of size 6mm to 03mm on the filter bed of the pressure filter uniformly after washing/cleaning to remove dust, dirts etc. in layerscomplete all as specified and as directed by Engineer-in-charge.
M&L for filling of gravel of size 3mm to 1.5mm on the filter bed of the pressure filter uniformly after washing/cleaning to remove dust, dirts etc. in layerscomplete all as specified and as directed by Engineer-in-charge.
M&L fresh sand of size 0.35mm to 0.5mm and co-efficient of uniformity shall be between 1.3 to 1.7 and silica content should be not less than 90%, filling in layers as filter bed, complete all as specified and as directed by Engineer-in-charge.
M&L for anthracite compound (carbofilt of RMCO or equivalent approved make by E-in-C or CE EC ) of size 25mm to 12mm suitable for removing tubidity and bad odour from raw water, complete all as specified and as directed by Engineer-in-charge.
Supply only PVC strainer for pressure filter, complete all as specified and as directed by Engineer-in-charge.
M&L for painting to internal surface of the Pressure filter chamber/steel tank etc with two coats of black bituminus paint (Lead free) suitable of drinking purpose after necessary surface preperation by means of scraping, brushing etc, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old external surface by scrapping, brushing etc and painting to external surface of the Pressure filter chamber or other MES installations with two coats of synthetic enamel paint of approved colour , complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old painted surface of brick/stone/plaster surface and painting by one coat of cement based paint over a coat of primer, complete all as specified and as directed by Engineer-in-charge.
M&L for rough excavation in slit/ sand/ shingle/ gravel boulder/leaf/stem/branches etc. not exc. 0.5 cum in hilly stream source, re-diverting and re-aligning tha intake point for river stream including dissposal off excaveted materials on the bank at a distance not exc. 10 mtr etc incl all allied T&P, protection tools, complete all as specified and as directed by Engineer-in-charge. Note - Date wise record shall be kept and measured.
M&L for cleaning of slit and mud clay mixed with sand, shingle, gravels/leaf/stem/branches etc. not exc. 0.5 cum etc from the collector pond with using suitable arrangement whenever necessary including cleaning of choked/partially choked intake pipes and sedimentation tank incl all allied T&P, protection tools and disposed off at a distance not less than 50m, complete all as specified and as directed by Engineer-in-charge. Note - Date wise record shall be kept and measured.
Demolition of unreinforced cement concrete in ground floors and pavings not exc. 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge.
M&L for hardcore of guage not exc. 63mm deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulders, complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C-1 (20mm graded stone aggregate) as in foundation, mass filling and staging of MS tank/PVC storage tank box repair to floor, path incl necessary form work and fair finishing without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair rotational moulded polyethylene water storage tanks double layered ISI Marked (cylindrical, vertical with closed top) of 2000 Ltrs capacity hoisted and fixed in position all as specified and directedin SSR Pt I.
Demolition of brick work built in any cement mortar complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with sub-class flyash brick straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with flyash bricks with honeycomb walling built in CM 1:6 complete all as specified and as directed by Engineer-in-charge.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface finishing even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of cement based paint on walls over a coat of alkali resistant primer, complete all as per specified and as directed by Engineer-in-charge.
S&F cast iron mechanical water meter woltman type, Flanged, PN16, Epoxy Powder coated suitable for 100 mm dia pipe including all necessary arrangement (Standards as per ISO 4064:2005), complete all as specified and as directed by Engineer-in-charge.
Taking up or down steel tubing GI 80mm and connections, including cleaning the pipes free from scaling and refixing of old steel tubing and connection in new or old position including, cutting threads if required fixing with old/new bends, elbows, socket, nipple, tapers, and reducers etc and laid in floors, walls and testing for leakages, complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S TSHERING BHUTIA
Damdoo Bhutia
Darjeeling Enterprises
KWOK YING CHIU
HIRA SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .