Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹8.3 L+₹51,036.54 (6.56%)Rejected-Finance C O 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being not a lowest | |
| 3 | L3₹9.5 L+₹1.7 L (21.9%)Rejected-Finance | L3 | Rejected-Finance Being not a lowest | |
| 4 | L4₹10.9 L+₹3.1 L (39.7%)Rejected-Finance | L4 | Rejected-Finance Being not a lowest |
Tender Value
₹10.5 L
EMD Value
₹21,000
Closing Date
28 Nov 2022, 6:00 pmClosed
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
SPECIAL REPAIR TO BLDG NO T-1, T-2, T-2A, T-12, T-15 AND T-22 UNDER AGE BR-I OF GE (WEST) PATHANKOT
2022_MES_560161_1
GE/PKT-50/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹21,000
Yes
22 Dec 2022
28 Oct 2022
30 Nov 2022
28 Oct 2022
28 Nov 2022
14 Nov 2022
29 Oct 2022 - 10 Nov 2022
Amount
Demolition of brick work , built in cement mortar or cement lime mortar including all quions, arches, pillars, etc including demolition of precast rcc articles and disposal of debris out of MoD land complete all as specified and directed.
M&L for Brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
All as per item No 02 above but except bricks. Note:- Old burnt clay bricks retrieved from demolition shall be used.
Demolition of cement concrete or lime concrete (unreinforced) in ground floors and Pavings not exc 15 cm thick (below or above ground level ) and removing the debris outside from defence land complete all as specified and directed .
Material and labour for Cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and complete all as specified.
M&L for 25mm thick Cement concrete in sub base for receiving floor tiles and mass concrete using Type B-1,1:2:4 (using 20 mm graded crushed stone aggregate) complete all as specified and directed. Note:- Finishing surfaces of concrete to be even and rough to receive the topping layer or floor tiles etc
M&L 40 mm thick plain cement concrete type B-1 , 1:2:4 (using 20 mm graded crushed stone aggregate) finished even and smooth without using extra cement as in flooring complete all as specified and directed. Note- Glass dividing strips shall be measured & paid separately as supply only.
M&L for 75 mm thick cement concrete type D-2, 1:4:8 using 40mm graded crushed stone aggregate complete all as specified and directed.
Demolition of cement concrete or lime concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing the debris outside from defence land complete all as specified and directed .
Material and labour for PCC in foundations, filling and mass-concrete type D-2 (1:4:8) using 40 mm graded crushed stone aggregate complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 in surface channels and drains complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises and removing the debris outside from defence land complete all as specified and directed .
Dismantaling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortor complete all as specified and directed.
M&L for 20mm thick granite (pure black) work (table rubbed and polished) in steps, jambs pillars, window cills ,cooking platform and like including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade or granite over including 15mm thick screed bed or bedding layer in cement mortar 1:6 etc complete all as specified and directed. Note:- The stone slab shall be in one piece over kitchen plateform,window cill and making gas pipe holes 25mm dia with rounded holes and all open edges to be half rounded.
Material and labour for coloured Glazed ceramic tiles in vertical surface such as dado etc 450mmX 300mmX 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:4 complete all as specified and as directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles.
Supply and fixing joint free non skid coloured Ceramic tiles 07mm to 08mm thick (square/ rectangular) polished, area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles.
M & L machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over screed bed or bedding layer 20 mm thick in cement mortar 1:4, complete all as specified and as directed. Note:- Rate included for all cutting ,waste including machine cutting to make it square or rectangular,cutting and polishing by machine & size of kota stone shall not be less than 550 mmx550mm .
M & L machine cut kota stone slab 14-16mm thick in riser of steps, skirting, dado and pillar laid over backing coat 10mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed. Note:- Rate included for all cutting ,waste including machine cutting to make it square or rectangular,cutting and polishing by machine & size of kota stone shall not be less than 550 mmx550mm .
Demolition of Roofs, floors (other than ground floors), beams staircases, landing, cooking platform ,chajjas, & similar suspended work cement concrete is reinforced (reinforcement cut as required to facilitate demolition) and disposal of debris out of MoD land complete all as specified and directed. Note:- Demolition will be done only by mechanical cutter only .
Material and labour for RCC type B-1 (1:2:4) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like such as cover slab of septic tank/soak well etc complete all as specified and as directed. Note:- Reinforcement shall be measured and paid separately).
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat complete all as specified and as directed
Material and labour for Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and as directed.
Taking down cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Material and labour for rendering 15mm thick in CM 1:4 mixed with liquid water proofing compound (as per manufacturer’s instructions) on fair faces of brick work ,concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed. (Note:- WPC shall be measured and paid separately)
Material and labour for two coat plaster 15 mm thick (10 mm + 5 mm) on rough concrete surfaces of fin, facia, chajjas and similar article in cm 1:3 with liquid water proofing compound (as per manufacturer’s instructions) mixed in both coats, finished even and smooth without using extra cement including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed.(Note:- WPC shall be measured and paid separately) Note :- Two coat plaster shall be carried out as mentioned in clause 14.18 of SSR-2009, Part-I complete all as specified and directed.
Material and labour for rendering 10 mm thick in cm 1:6 on other than fair faces of brick work , concrete surfaces of wall,finishing surfaces even and smooth without using extra cement including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed.
Material and labour for preparation of newly plastered internally surfaces of wall and applying min 1.5 mm thick wall care putty on the surfaces & making the surface absolutely smooth surface and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion finished without any brush marks on the surface in any colour including necessary scaffolding up to four storeys height of bldgs if required ,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
Material and labour for complete removal of existing treatment internally surface of wall and applying min 1.5 mm thick wall care putty on the surfaces and making surface absolutely smooth and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion without any brush marks on the surface in any tint including necessary scaffolding up to four storeys height of bldgs if required ,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
Material and labour for preparation of old painted steel and iron surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint in any colour finished without brush mark on surface including necessary scaffolding up to four storeys height of bldgs if required,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer all as specified and directed.
M & L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
Taking down chowkhats or frames exc 1.50 and n.exc 4 Sqm each (without talking off shutters from the freme) complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site complete all as specified and directed .
Taking down shutters of any description exc 1 sqm but not exc 2 sqm each and removing from site complete all as specified and directed.
S & F pressed steel frames 105 x 60 x1.25 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate including one shop coat of primer complete all as spd and directed
M & L for cement concrete type C-0, 1:3:6 using 12.5 mm graded crushed stone aggregate as in back filling of hollow portion of frame with plain cement concrete and for fixing of hold fast complete all as specified and directed.
S & F pressed steel frames 125 x 60 x1.25 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate including one shop coat of primer complete all as spd and directed
S&F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, confirming to IS- 2202(Part-I-1999), ISI Marked complete all as specified and directed
S&F 35mm thick factory made 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed . Note: wire cloth shall be measured separately
Supply and fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed .
S&F Steel window/ventilator factory made, made out of mild steel box type and shutter suitable for double shutter i.e. Glazed and gauged shutter. Glazed shutter made out of hollow' section with sash bar and gauged shutter made out of hollow section without sash bar including hinges, tower bolt, handle, grill 10 mm sq bar including two coat of synthetic enamel paint over one coat of red oxide primer, tarred hold fasts, PCC bed blocks for fixing hold fast , including plain/figured glass and wire mesh complete all as per details shown in drawing No CEPZ/TD-245/01 sheet No 1/1 and CEPZ/TD-246/01 sheet No 1/2 & 2/2 including taking down existing spoiled and unserviceable windows/ventilators of any type ( wooden/steel) complete all as specified and directed
M&L in repair for 18/19mm thick Prelaminated particle board,ISI marked, exterior grade,prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with screws rawal plug to timber frame work including all exposed edges with 6mm thick teak wood lipping and finish with french polished as in cupboards, kitchen cabinets,shelf etc complete all as specified and directed.
S&F for Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass, polished complete all as specified and directed
S&F hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws, Size of hasp and staple in mm 100 complete all as specified and directed.
S & F Continuous (piano) hinges 30mm Width of flaps (when open) ,mild steel, bright finish or electrogalvanised complete all as specified and directed
Supply and fixing Aluminium, anodised, barrel tower bolts of extruded section and fixed, Length of bolt in 150mm complete all as specified and directed
Supply and fixing Aluminium, anodised, barrel tower bolts of extruded section and fixed, Length of bolt in 200mm complete all as specified and directed
Supply and fixing Aluminium handles, cast type, anodised Size of handle in 150mm complete all as specified and directed.
Supply and fixing Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed Length of bolt in 250 mm complete all as specified.
Supply and fixing Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor Overall length of cover plate 140mm complete all as specified and directed.
S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate including welding to steel frames complete all as specified and directed.
Supply and fixing in repair harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc.all as specified and directed.
Welding in repairs n. exc 2.5cm in length thickness of metal to be welded n exc 6mm complete all as specified and directed.
Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed.
S&F 15mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed.
Fixing only 15mm bore old Steel water tubing including all new galvanized fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. (Note: - Old Steel water tube/pipe any type retrieved from taking down shall be used along with all new GI fittings)
Taking up or down 20mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed.
S&F 20mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed.
Fixing only 20mm bore old Steel water tubing including all new galvanized fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. (Note: - Old Steel water tube/pipe any type retrieved from taking down shall be used along with all new GI fittings).
S&F Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
S&F Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
S&F Rotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling of old broken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed.
S&F Rotational moulded polyethlene water storage tanks three layers of 1000 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling of old broken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed.
S & F in repair 15 mm bore long body CP Bib taps cast copper alloy fancy type with capstan heads (chromium plated),and cup screwed down , high pressure for iron pipe complete all as spd & directed.
S&F in repair 15 mm bore Stop valves, fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair stop valves (ISI marked), 15mm dia, cast copper alloy,chromium plated fancy type with long shank and cup(concealed type) screwd down,high pressure with crutch or butter fly handle,screwed both ends for iron pipes or for unions and fixed in pipe all as specified and directed.
Supply and fix for in repairs CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks & fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair tubular towel rail, 20mm dia, D type, 60cm long between flanges all as specified and directed.
S&F in repair soap dish (minimum weight 300 grams) of stainless steel fixed to wall with aluminium screw, complete all as specified and directed.
S&F in repairs Viterous China wash basin, white, flat back, size 550x400mm excluding taps etc but including brackets,including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specfied and as directed.
S&F in repair sink with drainage board made of stainless steel 1 mm thick with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of angle iron and connecting union to pipe over all size 915 mm x460 mm and bowl size 410mmx330mmx 160mm complete all as specified and directed.
S&F in reapir Stainless steel plate rack(Utensil Rack) of size (900mm x 750mmx250mm ) made out of AISl 304 stainless steel 0.63 mm thick sheet fixed with brass screw of required size including necessary fittings/nuts,bolts & washers complete all as specified and as directed.
S&F in reapir 15mm dia 600 mm long PVC connection including brass check nut at both ends screwed both end for iron pipes complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, PVC/AC or Reinforced concrete) set in cement mortar,and taking out of trenches, if required, Internal dia of pipe in 75MM/100mm complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed.
Taking down eaves gutter and rain water pipe any size any pattern , PVC/ AC pipe including all fittings ,heads shoes, bends etc including removal to store ,Internal dia of pipe in 75MM/110mm complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed. (ISI MARKED)
S&F PVC (SWR) bends any radius 75mm dia all as specified and directed. (ISI MARKED)
S&F PVC (SWR) bends any radius 110mm dia all as specified and directed. (ISI MARKED)
S & F in repairs 75mm PVC floor trap, ISI marked with cp grating with/without waste pipe hole incl jointing to waste pipe fixed with solvent cement complete all as specified and as directed.
Dismantling asbesots cement (corrugated, semi-corrugated etc) sheets in roof coverings Complete all as specified and directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling wall and ceiling boards or insulation boards any thickness, any description including cover fillets complete all as specified and directed
S & F for suspended false ceiling system using chicago metallic (E grid)exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) complete all as directed.
Dismantling structural steel work including doors gates but excluding framed truss etc.complete all as specified and directed.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to a common rafters and rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410-W(Gde-E-250) quality B complete all as specified and directed.
Supply only glass dividing strips 3mm thick and 35mm wide complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed
Taking down old unserviceable copper/aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses, lamp holder, regulators and sockets by unscrewing carefully from boards etc and making good disturbed surfaces of walls, as per existing finishes complete all as spd and directed. (Note:- The damaged surfaces to be made good with plastering (1:6) & applying colour wash in required coats to matching with existing surfaces as directed by Engr-in-charge. Cost of the same deemed to be included in the quoted rates and nothing extra on this account admissible.)
M&L Point wiring with 1.5 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade drawn through and incl PVC rigid concealed conduit (ISI Marked) suitable size with all accessories having thickness not less than 1.8mm incl sheet steel/ CI terminal box of adequate size having thickness not less than 2mm including 3mm thick hylem/masonite sheet including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor multistranded cable of green colour as earth conductor connected to common earth dolly complete all as specified and directed for one light / fan point controlled by one switch 5 Amp, SP, one way, 240 Volts. Note: 1. Connections of cable with MCBs/Switch Sockets shall be done through proper size copper/brass thimbles. 2. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit in not feasible. 3. Proper colour code will be used for wiring as per the electrical rule and as directed.
All as per Srl item No 96 here-in-before but for one 5 pin 5 Amp socket outlet point on inependent board controlled by one switch SP, one way 5 Amp, 240Volts complete all as specified and directed.
All as per Srl item No 96 here-in-befor but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed.
M & L for point wiring with 2.50 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable in existing PVC concealed conduit terminated in new anodised pressed steel sunken box having thickness not less than 2 mm with 3 mm thick ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed piping ,including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green).
S & F switch piano flush button single pole one way 5 Amp AC 240 volts, all as specified and as directed.
S & F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed.
S & F socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
S & F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed.
M & L for ceiling rose, PVC/Polycarbonate, insulated body, surface Bakelite 65mm dia three terminals all as specified and as directed.
Supply and fixing ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed.
S & F LED bulb, B22 type ,14 watt, complete all as specified and directed.
S&F 22W surface / wall mounted batten LED luminair, extruded aluminium housing with PC diffuser and ind electronic driver with high efficiency long life, CRI = 80 (Minimum), PF > 0.95, luminous efficacy > 100 lumens/Watt operating voltage 140V-240V, CCT (K) > 6500, THD < 10% complete including 22W LED tube rod with all accessories internally prewired and including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and directedories prewired and including making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed.
Supply and fixing LED luminaire 600 mm X 600 mm , 35/36 watt 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver holder & driver & LED lamp suitable for roof ceilingincluding connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.
S&F in replacement Energy saving, surface mounted, bulk head LED luminaire 10 W with PDC aluminium housing and polycarbonate diffuser with IP 66 protection complete including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Taking down ceiling fan by disconnecting the electric connection and dismantling the blades and removing from ceiling/roof of bldg by descrewing the nut, bolt etc complete all as specified and directed.
Rehanging only of ceiling fan and connecting up including provision of PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50Sqmm from ceiling rose or connector to fan including minor repairs such as replacement of locking pin, reel insulators, bolts, nuts etc and spraying one coat of synthetic enamel paint of required color all as pewr required and directed by Engr-in-charge.
S & F of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
S&F MCB SP 240V, 50Hz, 10 KA, 'B' curve of rating 6 to 32 Amp all as specified and directed.
S&F MCB SPN 240V, 50Hz, 10 KA, 'B' curve of rating 6-32 Amp all as specified and directed.
M&L for sub Main Wiring with 2 run of single core, 6 Sqmm FRLS PVC insulated and unsheathed, multi starndedcopper conductor cable using colour code for phase red and neutral black with and including 6 Sqmm FRLS PVC insulated and unsheathed copper conductor cable in green colour as earth conductor connected to common earth dolly, drawn in and including concealed PVC rigid conduit of suitable size having thickness not less than 1.8mm (ISI marked) with and including all accessories complete and making good to disturbed surface of wall/floor with cement mortar and finishes to match existing surface including taking down of existing unserviceable surface/cocealed sub main wiring any type complete all as specified and directed. Note: Two run of submain wire (phase and neutral), and one run of earth including PVC conduit and accessories will be measured as one run.
S & F bldg secuirty light fitting energy saving high efficiency LED street light fitting 30 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 32 mm dia bent to shape having length on less than 1.5 mtr fixing with clamp etc and making connections using cord flexible 3 core copper cable of size 23/ .0076 from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.25 metre deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as showin in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust, common salt all around Earth plate upto 150 mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40 mm thick RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregrate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including test on completion. (Note :- The rate quoted include cost of min 7.5 metre earthing wire)
S & F in replacement of old unsv sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a)MCCB FOUR POLE 100 AMPS AC 415 VOLTS 25 KA= 01 NO = ICS =ICU=100 % adjustable thermal & magnetic release as incoming and 12 nos. MCB SP 40 Amps, 10 KA , ISI marked C series as outgoing (i) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(ii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iii) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (iv)MCCB's and MCB's should have a same make as of DB.
M & L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing MS ventilating fans Single phase, 230 volts 480 mm or 12” H.D EX Fan (900 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge.
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, 25 Sq mm, 3.5 core in replacement including taking out/down of old UNSV cable any description complete all as spd and directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as spd and directed by Engr-in-charge.
M&L for old size Brick covering with equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified.
Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified.
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 34534.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 3% (Three percent) of the accepted contract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
VAISHNAVI BUILDERS
M/S Raghuvanshi Builders
V K Sharma and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .