Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹16.7 L+₹1.3 L (8.27%)Rejected-AOC MAHALAXMI ENCLAVE OPPOSITE SLP COLLEGE MORAR GWALIOR MP | GWALIOR | GWALIOR | MADHYA PRADESH | L2 | Rejected-AOC Rejected | |
| 3 | L3₹19.1 L+₹3.6 L (23.4%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
₹16.5 L
EMD Value
₹33,000
Closing Date
23 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JHANSI
HQ CWE JHANSI
RENEWAL/REPLACEMENT OF OH ELECT LINE WITH UNDERGROUND CABLING AT NCC OTA, GWALIOR
2023_MES_582571_1
CWE/JHA/GWL/TOKEN/102 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GWALIOR
As per tender documents
8 documents required · 8 mandatory
₹500
GE GWALIOR
₹33,000
Yes
9 May 2023
23 Feb 2023
30 Mar 2023
23 Feb 2023
23 Mar 2023
10 Mar 2023
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand filling/cushioning in trenches for cable protection including consolidation complete all as specified and directed.
Supply and laying reinforced precast concrete cable, cover, but Class LV, Type I, falt, size 250 mm x 150 mm x 400 mm complete all as specified and directed.
M&L for repair/replacement of stay assembly with 20 mm dia rod complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and directed.
M&L for repair/replacement of loop type insulator, vitreous porcelain white ,brown or green large size over all dimension 90 X 140mm, clearance of the hole 25.5mm for stay assembly complete all as specified and directed.
Supply, laying and testing of cable XLPE insulated, armoured,heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts grade, of following size:-
16 Sqmm 4 core.
25 Sqmm 3.5 core.
35 Sqmm 3.5 core.
50 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 Sqmm 3.5core.
240 Sqmm 4 core
Felling of trees exc 30 cm girth including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to a distance of exc 50 m and clearing site complete all as specified and directed.
M&L for GI Pipe light grade complete with fittings laid in floor/ trenches/ wall as cable protection of 100 mm dia all as specified and directed.
M&L for GI Pipe light grade complete with fittings laid in floor/ trenches/ wall as cable protection of 50 mm dia all as specified and directed.
M&L End joint Heating kits indoor/outdoor type for LT cable of size 6 to 16 sqmm, XLPE armoured cable 4 core complete all as specified and directed.
M&L End joint Heating kits indoor/outdoor type for LT cable of size 25 to 50 sqmm, XLPE armoured cable 3.5 core complete all as specified and directed.
M&L End joint Heating kits indoor/outdoor type for LT cable of size 70 to 95 sqmm, XLPE armoured cable 3.5 core complete all as specified and directed.
M&L End joint Heating kits indoor/outdoor type for LT cable of size 240 sqmm, XLPE armoured cable 3.5 core complete all as specified and directed.
Supply & Fixing junction box for street light of size 200mm x 155mm x 80mm made of polycarbonate with IP 65 degree of protection (EN60529), dust proof, water tight, light weight, acid resistant, corrosion proof inslated & shock proof, fire retardant, self extinguishing, halogen & silica free non-toxic material, UV resistant, with internally ebbedded gasket fitted with required terminals , should have to be test certificate and veryfied by glow-wire test in accordance with IEC60695-2-11. Including MCB SP 10A 240V - 01 fitting arrangement complete all as specified and directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP 32 Amps in the DB box/ Panel complete with connection testing and commissioning complete all as specified and directed.
Supply, installing, testing and commissioning of outdoor Bus Bar panel board 400 Amps aluminium busbar, 415 Volts, 3 phase, 4 wire - (01 No incomming) with incomming MCCB 415V,200A, 4 pole, 36 KA, factory fabricated powder coated, cubical, weather and vermin proof outdoor kiosk type, front opening, floor mounted made out of 3.15 mm thick CRCA sheet of size (70 x 70 x 50) cm suitable for mounting the various size of electric distribution armoured cable with glands, lugs as per sit reqd to be fixed, mounted on steel angles supports of suitable size with grouting 4 Nos supports of aprox 60 cm height angle iron above the ground level in PCC 1:2:4 type B1 complete with separate compartment for housing with proper arrangement for air circulation and including the 400 Amp rating aluminium Busbar all as specified and directed.
All as per Ser item No 19.00 above but 150 Amp rated aluminium busbar of size (70 x 70 x 50) cm, with 100 Amp MCCB 4 Pole 16 KA incomming complete all as specified and directed.
All as per Ser item No 19.00 above but 100 Amp rated aluminium busbar of size (70 x 70 x 50) cm, with 63 Amp MCCB 4 Pole 16 KA incomming complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenches technology using ultra sound technique and necessary machine including HDPE pipe of 100mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply and erecting 9 mtr height octagonal Steel Pole with base plate, bottome size 185mm, Top dia 75mm and sheet thickness 10mm complete all as specified and directed.
M&L for cement concrete (1:4:8), type D-2, using 40 mm graded crushed stone aggregate for foundation of poles/struts/stay assembly etc all as specified and directed.
M&L for cement concrete (1:3:6), type C-1, using 20 mm graded crushed stone aggregate for pedestal of poles/coping including necessary form work, fair finishes to the exposed surface using extra cement all as specified and directed.
All as per Ser item No 26.00 but 200 Amp bus bar and Incomming MCCB 100 Amp, 415V, 4 pole, rupturing capacity 16 KA- 01 No, Outgoing MCCB 63 Amps, 415V, 4 pole, rupturing capacity 16KA complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in single red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
Supply and install HT 11 KV out door type gang operated air- break switch suitable for horizontal or vertical mounting with drop out fuse having 12 insulators of rating upto 200 Amps complete all as specified and directed.
M&L lighting arrester( expusion) having voltage rating 12 KV, Rated frequency-50 HZ, Nominal Discharge current 65 KA(Heavy duty) complete with all fittings , suitable for 11KV, 3-Phase, earthed distribution system ISI marked complete all as specified and directed..
Dismantling insulators any type, any size complete all as specified and directed.
Taking out street light with bracket carefully from PCC pole and refixing the same on new pole complete all as specified and directed
Dismantling PCC pole/struts any size and removing from site complete all as specified and directed.
Dismantling of cross- arms, clamps, danger plate of MS channel or angle sections etc.and removing from site complete all as directed.
Dismantling steel earth wire from existing overhead service feeder etc all as specified and directed.
Dismantling ACSR conductor of any size from existing overhead service feeder etc all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron stripe of size 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or directed including testing on completion complete all as specified and directed.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
M.S. ENGINEERS
Om Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .