| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.5 LAccepted-AOC | ₹79.5 L Quoted ₹79.7 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹81.8 L+₹2.1 L (2.58%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | ₹81.8 L+₹2.1 L (2.58%) | L2 | Rejected-Finance Higher Bidder |
| 3 | L3₹82.9 L+₹3.2 L (3.96%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | ₹82.9 L+₹3.2 L (3.96%) | L3 | Rejected-Finance Higher Bidder |
| 4 | L4₹88.7 L+₹9.0 L (11.3%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹88.7 L+₹9.0 L (11.3%) | L4 | Rejected-Finance Higher Bidder |
| 5 | L5₹99.4 L+₹19.7 L (24.7%)Rejected-Finance CHATAI SHEEP WARD NO 07 NEW MARKET ROAD AHIWARA DURG CHHATTISGARH 490036 | DURG | CHHATTISGARH | 490036 | ₹99.4 L+₹19.7 L (24.7%) | L5 | Rejected-Finance Higher Bidder |
Tender Value
₹88.3 L
EMD Value
₹1.6 L
Closing Date
17 Feb 2022, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
MANNING AND OPERATION OF LIFTS AT HQ KNA NSRY NOM MESS AND PATANJALI AT NAVAL BASE KARWAR AND MANNING AND OPERATION INCLUDING REPAIR AND MAINTENANCE OF DISTRIBUTION SUB STATION DSS 01 AND DSS 08 AT NAVAL BASE KARWAR AND DSS 17 AT AMDALLI UNDER GE S
2022_MES_502713_1
85557/E8
Open Tender
Civil Works
Item Rate
334 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE SB KARWAR
₹1.6 L
Yes
4 May 2022
20 Jan 2022
19 Feb 2022
20 Jan 2022
17 Feb 2022
3 Feb 2022
Amount
LIFTS AT HQ KNA, NSRY, NOM MESS & PATANJALI
Notes for Item Nos 1 to 4:- (a) The Contractor shall not employ same tradesman continuously for more than 11 months. (b) The contractor shall provide 02 uniforms to each operator and design of uniform shall be got approved from Engineer-in-Charge. In case contractor fails to provide the uniform, recovery @ of Rs 100/- per day per operator shall be recovered (c) The rate quoted shall deemed to be inclusive of safety gear & required tools for minor maintenance. In case of failure to provide tools kit & safety kit (Gum boots-02 pairs) a penalty of Rs 3000/- shall be recovered and levied. (d)The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maintenance is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly.
(e) Each shift duration shall be 08 hours & duty timing will be decided by Engineer-in-Charge. (f) In case of failure due to absence of operative staff,the contractor shall be liable to pay compensation at twice the cost of a day's Manning & operation derived from pro rata rate of Sch'A' quoted rates or Rs.1000 per person per shift whichever is higher. (g)The operator shall ensure general area cleanliness and upkeep of the lift on daily basis. (h) The contractor shall pay the wages to the operator through e-payment i.e Aadhar linked bank accounts and Credit to their bank account. The wages shall not be less than prevailing minimum wages fixed by state Govt or central Govt whichever is more.
(j) It is the responsibility of contractor to deposit the employees provident fund (EPF) to the concerned authority as per the prevaling scales as laid down by Ministry of labour for all operator/helper (as applicable) and necessary proof to this regard shall be submitted to the Engineer-in-charge for verification & record. The quoted rates shall be deemed to be included of above provisions. In case contractor fails to produce the proof of EPF, the same shall be recovered from his dues as per the prevailing scale plus 15 percent. (k) The contractor shall provide board at proper location near each installations duly writing the name of operators and Mobile Numbers shiftwise. (l) Contractor shall display the lift safety precautions as per Appendix ‘C’ enclosed as serial page Nos.148 & 149 are enclosed herewith and as directed by the Engineer-in-Charge. (m) The rates quoted shall be inclusive of all taxes, cess, levies etc as applicable including GST (n) The prevailing rate,wage,contribution etc shall be as applicable as on the bid submission end date.
(o) In view of COVID-19 alerts various restrictive instructions issued concerned authorities from time to time. Hence additional precautions essential for the work shall be taken by the contractor by way of provisioning of masks, hand sanitizers, gloves etc to workmen and all local instructions issued by the Concerned Authorities and Station Authorities shall be complied with all relevant safety precautions covered under Model Rules for the protection of health and sanitary arrangement for workmen (Annexure ‘C’) of IAFW-2249) shall be strictly followed. Nothing extra is admissible on this account (p) The contractor shall also deploy additional man power as relief against weekly off,leave,holidays etc all as per existing Labour Act and shall substitute the operator accordingly for which no extra payment admissible. The unit rate quoted against items in Schedule ‘A’/BOQ shall be inclusive of this provision also.
Inspector of lift for worthiness certificate during the period of contract including load testing as per lift ACT and submitting the worthiness certificate to Engineer-in-Charge all as specified and as directed Location : HQKNA-02 Nos,NSRY -02Nos,PATANJALI - 04 Nos, NOM - 01 Nos Total Lifts - 09 Nos Note:- All lifts shall be inspected once in six months period by the competent person recognized under Department of Factories, Health & Safety, and copy of Certificate should be displayed on each lift.
Supply and Fixing in replacement of Automatic Rescue Device in 26 Passenger Lift in Patanjali Building complete all as specified & directed.
Supply and Fixing in replacement of Automatic Rescue Device in 8 Passenger Lift in HQKNA/NOM/NSRY complete all as specified & directed.
Supply and Fixing in replacement of Automatic Rescue Device in 1500 KG Goods Lift in NSRY complete all as specified & directed.
Supply and Fixing in replacement of A R D Batteries suitable for ARD complete all as specified & directed.
DSS-01 & 08 AT NAVAL BASE KARWAR
Manning and Operation of Distribution Sub Station (DSS - 1) at KNOFRA Little Binaga, the main load centre at officer's residential area for three shifts of 8 hours each on all days including Sundays and holidays including routine preventive maintenance / checks, attending emergency breakdowns at Distribution Sub Stations DSS 1, DSS 1A and connected feeder pillars all as directed
Manning and Operation of Distribution Sub Station (DSS - 8), the main load centre at sailor's residential area for three shifts of 8 hours each on all days including Sundays and holidays including routine preventive maintenance / checks, attending emergency breakdowns at Distribution Sub Stations DSS 8, DSS 9, DSS-10 & DSS-11 connected feeder pillars all as specified and as directed
Notes for Item Nos10 to 11:- (a) The rates quoted shall be inclusive of all taxes ,cess, levies etc as applicable including GST (b) The prevailing rate,wage,contribution etc shall be as applicable as on the bid submission end date. (c) Shift timings:1st shift from 0600 hrs to 1400 hrs,2nd shift from 1400 to 2200 hrs and 3rd shift from 2200 hrs to 0600 hrs respectively (d) Contractor has to employ minimum one No skilled electrician /operator per shift of 8 hour each,(Total 06 shifts per day) having minimum ITI qualification in Electrician trade from Govt recognized institute with adequate knowledge with minimum 2 years experience in Maintenance & Operation of HT & LT electrical installation. The operator must be competent to carry out the routine maintenance and attending breakdowns all as directed (i) The contractor shall pay the wages to the operator through e-payment i.e Aadhar linked bank accounts and Credit to their bank account. The wages shall not be less than prevailing minimum wages fixed by state Govt or central Govt whichever is more.
(ii) It is the responsibility of contractor to deposit the Employees Provident Fund (EPF) to the connected authority as per the prevailing scales as laid down by the Ministry of labour for all Electrician/operator/helper (as applicable) and necessary proof to this regard shall be submitted to GE for verification and records. The quoted rate shall be deemed to be included of above provisions. In case contractor fails to produce the proof of EPF, he shall be liable for action as deemed fit. Decision of GE in this regard shall be final and binding. (e) The unit rate quoted shall be deemed to include for cost of labour for daily routine maintenance as mentioned in particular specifications for trouble free functioning of installations. (f) The operator employed by the contractor shall be capable of carrying out minor maintenance & unit rate quoted shall be deemed to be include for cost of stationery, ink cartridge for printer, cotton waste ,petroleum jelly for battery terminals etc. (g) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maintenance is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge. (h) Cost of stationery is deemed to include in the unit rate quoted against Item No 5.00 & 6.00 of Sch 'A'. (j) The contractor will ensure general area cleanliness and upkeep of the installation on daily basis.
(k) The contractor shall maintain all the registers under various labour law rules, 2017 and shall be produced to GE and as well as officers detailed by labour department. (l) Cost of routine maintenance spares will be measured and paid separately under respective item here in after. However cost of labour is deemed to be included in the unit rate quoted above. (m) The unit rate quoted shall deemed include for maintenance for earth pits, cutting & removing of vegetation and upkeep of the surrounding area, all around the bldg up to 6m from the plinth protection all as directed by Engineer-in-Charge. In case of failure, a penalty of Rs 2000/- per month will be levied and recovered from dues. (n) In the case of absence of operator, penalty will be charged as doubled as quoted rate or Rs 1000/-per shift whichever is higher besides any loss/damages occurring during the period which will have to be made good by the contractor
(o) The contractor shall provide 02 uniforms to each operator & helper and design of uniform shall be got approved from Engineer-in-charge. In case contractor fails to provide the uniform, recovery @ of Rs 1200/- per uniform will be recovered. (p) The rate quoted shall deemed to be inclusive of safety gear & required tools for minor maintenance. In case of failure to provide tools kit & safety kit (Gum boots-02 pairs, hand gloves), a penalty of Rs 3000/- will be recovered and levied (q) In view of COVID-19 alerts various restrictive instructions issued concerned authorities from time to time. Hence additional precautions essential for the work shall be taken by the contractor by way of provisioning of masks, hand sanitizers, gloves etc to workmen and all local instructions issued by the Concerned Authorities and Station Authorities shall be complied with all relevant safety precautions covered under Model Rules for the protection of health and sanitary arrangement for workmen (Annexure ‘C’) of IAFW-2249) shall be strictly followed. Nothing extra is admissible on this account (r) The contractor shall also deploy additional man power as relief against weekly off,leave,holidays etc all as per existing Labour Act and shall substitute the operator accordingly for which no extra payment admissible. The unit rate quoted against items in Schedule ‘A’/BOQ shall be inclusive of this provision also.
Supply only Ammeter Analog type suitable to 0 - 100 Amps all as specified and as directed
Supply only Aluminum lugs suitable for 25 sqmm to 50 sqmm cables all as specified and as directed
Supply only Aluminum lugs suitable for 70 sqmm to 150 sqmm cables all as specified and as directed
Supply only Aluminum lugs suitable for 150 to 300 sqmm cables all as specified and as directed
Supply only Sheared rubber gasket suitable to LT panel board any description all as specified and as directed
Supply only Indicator lamp LED type 'RYB' all as specified and as directed
Supply only Volt meter Analog type 0-500 Volts all as specified and as directed
Servicing of dry cast transformer 1600KVA , 11 KV/433V by disconnecting incoming & outgoing power supply, opening up, cleaning the transformer internally & externally inspecting all the metering equipments, tightening all electrical connections checking & recording insulation resistance on both LT & HT sides, checking & recording earth resistance complete through authorised Service Engineer of OEM all as specified and as directed. Location : DSS-1/ DSS-1A/ DSS4/ DSS-4A/ DSS-6/ DSS-8/ DSS-9
Servicing of oil cooled transformer 500 KVA , 11 KV/433V by disconnecting incoming & outgoing power supply, opening up, cleaning the transformer internally & externally inspecting all the metering equipments, tightening all electrical connections checking & recording insulation resistance on both LT & HT sides, checking & recording earth resistance complete through authorised Service Engineer of OEM all as specified & as directed. Location : DSS-10 and DSS-11 at corritop
S&F in repair ACB 4 Pole, 415 V, Manual Draw out type with microprocessor release of capacity 800 Amps complete all as specified and as directed.
M& L for repairs Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm all as specified and as directed.
M & L for Calibration of relays by primary current/voltage injection test complete for 33 KV/11 KV VCB panels and ACB panels/DG panels complete all as specified and directed.
Supply, jointing & testing in repairs Indoor end termination type heat shrinkable 11 KV HT joint kit suitable for 3 core 120/185 Sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed.
M & L for testing of resistance of earthpits of transformer, panels etc, after testing report shall be furnished to Engineer-in Charge in standard format approved by Engineer-in Charge all as specified and as directed.
Supplying and laying in repairs synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. complete all as specified and as directed.
Supplying and laying in repairs synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1 complete all as specified and directed.
Supply and fixing in repairs MCCB 4 pole, 415 volts fixed overload & fixed short circuit setting including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for capacity 160 Amps with breaking capacity 36 KA all as specified and as directed.
All as per Item No.28 here in before, but for 200 Amps with breaking capacity 36 KA all as specified and as directed.
All as per Item No.28 here in before, but for 250 Amps with breaking capacity 36 KA all as specified and as directed.
All as per Item No.28 here in before, but for 350 Amps with breaking capacity 36 KA all as specified and as directed.
All as per Item No.28 here in before,but for 400 Amps with breaking capacity 36 KA all as specified and as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 4.50 meter below normal ground level (with top edge of earth plate not less than 3.25 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board /panel etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round MS bar handle, GI light grade watering pipe 15 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed
Supplying and fixing in repairs 32mm X 6mm ,GI earth strip all as specified and directed
Supply and laying in repairs GI tubing 'Light' grade with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area/road for 100 mm dia size all as specified and as directed.
All as per Item No.35 here in above but for 50 mm Bore all as specified and as directed.
All as per Item No.35 here in above but for 80 mm bore all as specified and as directed.
M&L for Filtration of existing Transformer Oil including heating to improve di- electric strength of oil to minimum 60 KV BDV including testing of BDV of the filtered oil before & after all as specified and as directed.
M& L for low viscosity transformer oil, ISI marked to make up /top up oil deficiency in transformer all as specified and as directed.
S & F in repairs Silica Gel Breather of Transformers complete 500 KVA to 1000 KVA all as specified and as directed.
M & L for Painting of Transformer of 1600 KVA /500 KVA Capacity complete with Two Coats of Synthetic enamel paint externally and painting with a coat of Oil Resistant Paint inside the Transformer Shell complete all as specified and as directed.
S & F in repairs Strip heater/Panel Space Heaters 30-110 degree, SS 304 cartridge heater inside Black powder coated body, suitable for indoor panel of existing size/model complete all as specified and directed.
S & F in repairs Thermostat with setting 0-80C of existing size/model complete all as specified and directed.
M & L for Servicing of 11 KV Vaccum Circuit Breaker (VCB) 400/630/800/1250 amps by authorised service engineer of OEM (Original Equipment Manufacturer), drawing out circuit breaker mechanism, cleaning throughly inside & outside, lubricating the mechanism, adjusting the required various mechanism setting, checking & lubricating the various interlocks, checking the breakers operations, checking the healthiness of pole by meggering, lubricating racking mechanism, checking the operation of various limit switches, checking the operation of the breaker & the racking mechanism, testing the unit on no load & on load complete all as specified & directed.
Supply and fix in repairs exhaust fan, steel body AC single Phase, 230V of size 300m sweep with, blades, and frame and louvers and connected with flexible cord of size 23/0/0076 stranded copper conductor PVC insulated of length not less than 0.7m complete all as specified and directed. Note : Old unserviceable exhaust fan shall be deposited in MES store by the contractor.
DSS-17 AT AMDALLI
Manning and Operation of Main Receiving Distribution Sub Station (33KV/11KV) (DSS-17), 11 KV/433 Volt HT supply installation at site B, Amdalli town ship Karwar for three shifts of 8 hours each on all days including Sundays and Holidays including minor daily maintenance/checks and also attending breakdown at DSS-17A & DSS-17B, all as specified and as directed . The installation comprises of following equipments :- (a) 33 KV, indoor type HT VCB - 1 No (b) Indoor type Power transformer 2 MVA, 33 KV/11KV - 1 Nos. (c) Main LT Panel board 415 V with ACBs & main switches MCCBs etc (d) Battery bank for auxillary supply. (e) 55 Nos of batteries to maintain 110 V battery bank with charging panel.
Notes:- (a) The rates quoted shall be inclusive of all taxes ,cess, levies etc as applicable including GST (b) The prevailing rate,wage,contribution etc shall be as applicable as on the bid submission end date. (c) Contractor has to employ minimum following staff for Manning and operation of the DSS -17 in all 3 shifts 8 hours each. (i) One skilled electrician/operator per shift (3 shifts per day) having minimum ITI qualification in Electrician trade from Govt recognised institute with adequate knowledge for HT & LT electrical installation. The operator must be competent to carryout the routine preventive maintenance of Main distribution sub station all as directed. (ii) One No semi skilled supervisory minimum 10th class pass per shift (03 shift per day). (d) Cost of spares if any to be replaced will be measured & paid separately under respective item here in below. However cost of labour is deemed to be included in the unit rate quoted in this item
(e) Each shift duration shall be 8 hours and duty timings will be decided by Engineer-in-Charge. (f) The unit rate quoted shall be deemed to include for maintenance for earthpits, cutting & removing of vegetation and upkeep of the surrounding area, all around the bldg upto 6m from the plinth protection all as directed by Engineer-in-Charge. In case of failure, a penalty of Rs 2000/- per month will be levied and recovered from dues. (g) The contractor shall pay the wages to the operator through e-payment i.e Aadhar linked bank accounts and Credit to their bank account. The wages shall not be less than prevailing minimum wages fixed by state Govt or central Govt whichever is more. (h) In the case of absence of operator, penalty will be charged as doubled as quoted rate or Rs 1000/-per shift whichever is higher besides any loss/damages occurring during the period which will have to be made good by the contractor
(j) It is responsibility of contractor to deposit the employees provident fund (EPF) to the connected authority as per the prevailing scales as laid down by the Ministry of labour for all operator/helper (as applicable) and necessary proof to this regard shall be submitted to GE for verification and records. The quoted rate shall be deemed to be included of above provisions. In case contractor fails to produce the proof of EPF, shall be liable for action as deemed fit. Decision of GE in this regard shall be final and binding. (k) The contractor shall maintain all the registers under various labour law rules, 2017 and shall be produced to GE and as well as officers detailed by labour department. (l) The contractor shall provide 02 uniforms to each operator & helper and design of uniform shall be got approved from Engineer-in-charge. In case contractor fails to provide the uniform, penlty of Rs 1200/- per uniform shall be recovered. (m) The rate quoted shall be deemed to be inclusive of safety gear & required tools for minor maintenance. In case of failure to provide tools kit & safety kit (Gum boots-02 pairs, 33 KV HT hand gloves), a penalty of Rs 3000/- shall be recovered and levied
(n) In view of COVID-19 alerts various restrictive instructions issued concerned authorities from time to time. Hence additional precautions essential for the work shall be taken by the contractor by way of provisioning of masks, hand sanitizers, gloves etc to workmen and all local instructions issued by the Concerned Authorities and Station Authorities shall be complied with all relevant safety precautions covered under Model Rules for the protection of health and sanitary arrangement for workmen (Annexure ‘C’) of IAFW-2249) shall be strictly followed. Nothing extra is admissible on this account (o) The contractor shall also deploy additional man power as relief against weekly off,leave,holidays etc all as per existing Labour Act and shall substitute the operator accordingly for which no extra payment admissible. The unit rate quoted against items in Schedule ‘A’/BOQ shall be inclusive of this provision also.
S & F in repair HRC Fuse 250 Amps, type-3 NW of Cat No-3NW TKF250 complete all as specified and as directed
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
Supply & filling distilled water first quality in sealed container of standard capacity all as specified and as directed
S & F in repairs Strip heater/Panel Space Heaters 30-110 degree, SS 304 cartridge heater inside Black powder coated body, suitable for indoor panel of existing size/model complete all as specified and directed.
S & F in repairs Thermostat with setting 0-80C of existing size/model complete all as specified and as directed
M&L for Inspection of step down 33 KV / 11KV upto 3MVA transformer any make, plinth/floor mounted, indoor/outdoor type, inspecting the transformer for any leakage of transformer oil, removing the top cover of transformer attached with the gasket and rectifying any leakages found by replacing with new gasket of requisite size, inspecting all the metering equipments, tightening all electrical connections, checking & recording insulation resistance on both LT & HT sides, checking & recording earth resistance complete through authorized service engineer of OEM (Original Equipment Manufacturer) all as specified and as directed. The following tasks will be performed: (a) Strip opening of the transformer and removing the transformer top cover for checking/rectified the faults of the transformer. (b) Replacement of defective HT/LT bushes, brass spindles etc. (c) Refixing the transformer top cover with nuts, bolts and washers. (d) Testing of transformer. Notes: (i) Transformer oil (if required) for topping shall be measured and paid for separately under relevant item of Sch A/BOQ. (ii) Cost of hiring T&P, megger or any other instrument required at site deemed to be included in the cost of repair
M&L for Inspection of step down 11 KV / 0.433KV upto 750KVA transformer any make, plinth/floor mounted, type, inspecting the transformer for any leakage of transformer oil, removing the top cover of transformer attached with the gasket and rectifying any leakages found by replacing with new gasket of requisite size, inspecting all the metering equipments, tightening all electrical connections, checking & recording insulation resistance on both LT & HT sides, checking & recording earth resistance complete through authorized service engineer of OEM (Original Equipment Manufacturer) all as specified and as directed. The following tasks will be performed:- (a) Strip opening of the transformer and removing the transformer top cover for checking/rectified the faults of the transformer. (b) Replacement of defective HT/LT bushes, brass spindles etc. (c) Refixing the transformer top cover with nuts, bolts and washers. (d) Testing of transformer. Note: (i) Transformer oil (if required) for topping shall be measured and paid for separately under relevant item of Sch A/BOQ. (ii) Cost of hiring T&P, megger or any other instrument required at site deemed to be included in the cost of repair.
M&L for filtration of existing Transformer Oil including heating to improve di- electric strength of oil to minimum 60 KV BDV including testing of BDV of the filtered oil before & after all as specified and as directed
M&L for low viscosity transformer oil, ISI marked to make up /top up oil deficiency in transformerall as specified and as directed
M & L for Servicing of 33 KV Vaccum Circuit Breaker (VCB) 400/ 630/ 800/1250 amps by authorised service engineer of OEM (Original Equipment Manufacturer), drawing out circuit breaker mechanism, cleaning throughly inside & outside, lubricating the mechanism, adjusting the required various mechanism setting, checking & lubricating the various interlocks, checking the breakers operations, checking the healthiness of pole by meggering, lubricating racking mechanism, checking the operation of various limit switches, checking the operation of the breaker & the racking mechanism, testing the unit on no load & on load complete all as specified and as directed
All as per item No 56 here in before but 11 KV Vaccum Circuit Breaker (VCB) all as specified and as directed Note for item No 56 & 57: (a) Servicing of breaker to be carried out by qualified engineer. The servicing of breaker will include:- (i) Inspection & cleaning the mechanism house. (ii) Operation of door interlock, interlocking plate & shutter operation inside of panel. (iii) Check the mechanical ON-OFF function, electrical & mechanical operation & damage parts of VCB. (iv) Re-greasing & oiling of breaker mechanism, adjustment of various mechanism setting as required, checking contact tightness, contact erosion pins, manually vacuum check of VCB.
(v) Rack in-rack out operation in test & service position of VCB trolly. (vi) Megger test( IR value-1 KV/2.5 KV) E-RYB, RY-YB-BR, R'R.Y'Y.B'B. (vii) CRM test (contact resistence) of vaccum interrupter R,Y,B in on condition out side of panel. (viii) Time test of contact pole by test kit(in mili second) (ix) Function of closing coil, Trip coil, spring charge motor, auxiliary contact, limit switch etc. (x) Checking & lubrication of various interlocks. (xi) Submission of test report in standard format of vacuum circuit breaker(VCB). (b) Tools & testing instruments reqd for servicing of VCB will be arranged by the contractor. (c) The unit rate quoted shall be deemed to include the cost of grease, cleaning material service & list of spares required for preventive /breakdown maintenance (d) After servicing report will be furnished to Engineer-in Charge in standard format approved by Engineer-in Charge. (e) List of spare parts required for preventive maintenance/emergency breakdowns shall be submitted to Engineer-in Charge after 1st inspection.
Taking out ACB of make Siemens of capacity 800 Amps to 1500 Amps, 3pole ,415 Volts, 125 KA indoor type from its sub cubicle and carrying out routine maintenance as per manufacturer maintenance manual, examine the moving isolating contacts for any dis colouration, cluster contacts, remove the arc chutes, check the SMC moulding are intacts, examine the moving contacts, main contacts silver tips, spring mechanism, clean all contacts with a suitable solvent and contacts re-greased with HP multipurpose grease, check setting of all contacts, re-adjusted if required, and re-greased with HP multipurpose grease, testing of all tripping device like manual trip, under voltage, shunt trip release, over current and earth fault tripping device, readjusted and confirm all tripping device is in healthy condition, check and record IR value of ACB with 1.1. KV LT megger calibrating ground fault / short circuit, overload relays for tripping & timing complete and rendering test report all as specified and as directed.
Notes : (a) Rates is inclusive of fixing of spares if any reqd. (b) Spare parts which required to replace will be paid under respective items of Sch 'A'. (c) The scope of work includes the following :- (i) Inspection & cleaning the mechanism house (ii) Operation of door interlock, interlocking plate & shutter operation inside of panel. (iii) Check the Mechanical ON-OFF function, electrical & mechanical operation and damage part of ACB. (iv) Re-greasing and oiling of breaker mechanism, adjustment of various mechanism setting as required, checking contact tightness, contact erosion pins, manually vacuum check of ACB. (v) Rack in-Rack out operation in Test & service position of ACB trolley. (vi) Megger test (IR value - 1KV / 2.5KV) E-RYB, RY-YB, BR-R'R, Y'Y, B'B. (vii) CRM Test (contact resistance) of Vacuum Interrupter R, Y, B in on condition out side of panel (viii) Function of closing coil, Trip coil, spring charging motor, auxiliary contact, limit switches etc.
(ix) Checking & lubrication of various interlocks. (x) Submission of test report in standard format of Air circuit breaker. (xi) Tools & testing instruments required for servicing of ACB will be arranged by the contractor. (xii) The unit rate quoted shall be deemed to include the cost of grease, lubricating material, cleaning material service & list of spares reqd for preventive / breakdown maintenance (d) After servicing report will be furnished to Engr-in Charge in standard format approved by Engineer-in Charge. (e) List of spare parts required for preventive maintenance/emergency breakdowns shall be submitted to Engineer-in Charge after 1st inspection.
M & L for testing of resistence of earthpits of transformer, panels etc after testing report will be furnished to Engineer-in Charge in standard format approved by Engineer in Charge.
M & L for calibration of relays by primary current/voltage injection test complete for 33 KV/11 KV VCB panels and ACB panels/DG panels complete all as specified and directed.
M & L for painting to old steel surfaces of transformer, cable trays, panel board / LT out door panel board of DSS 17, DSS 17 A & B with one coat of synthetic enamel paint of approved shade using spray gun including cleaning/ removing, dust, dirt etc complete all as specified and as directed.
S&F in repair of current transformer 33 KV indoor type of ratio 100/1-1 single phase, 50hz, current ratio 800-400, including removing of old unserviceable CT complete all as specified and as directed.
S&F in repair of potential transformer indoor type, primary voltage 33KV, secondary voltage 11 KV single phase, 50hz, current ratio 800-400, including removing of old unserviceable PT all as specified and as directed.
S/F in repair of 11 KV bus bar supporting spout / insulators 130 MM LONG 60 MM DIA /as per sample single pole for indoor use 400 to 800 Amp suitable for existing panel complete all as directed and specified.
S/F in repair of Brown 33 KV Epoxy Bus Bar Support Insulators 300 /100 MM DIA /as per sample single pole for indoor use 400 to 800 Amp suitable for existing panel complete all as directed and specified.
Supply, jointing & testing in repair Indoor end termination type heat shrinkable 33 KV HT joint kit suitable for 3 core 185 Sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed.
S& F in repairs ACB 1250 Amps 4pole 415 V, manual draw out type with microprocessor release of capacity 630 Amps complete all as specified and as directed.
S& F in repairs ACB 630 Amps 4pole 415 V, manual draw out type with microprocessor release of capacity 630 Amps complete all as specified and as directed.
S&F in repairs MCCB 400 Amps 4 pole 36 KA breaking capacity,415 Volt adjustable type all as specified and as directed.
S&F in repairs MCCB 250 Amps 4 pole 36 KA breaking capacity,415 Volt adjustable type all as specified and as directed.
S&F in repairs MCCB 160 Amps 4 pole 36 KA breaking capacity,415 Volt adjustable type all as specified and as directed.
S&F in repairs MCCB 125 Amps 3 pole 25 KA breaking capacity,415 Volt adjustable type all as specified and as directed.
S&F in repairs MCCB 25 to 100 Amps 3 pole 16 KA breaking capacity,415 Volt fixed type all as specified and as directed.
Servicing of battery bank at DSS - 17 AUXILIARY D.C. POWER SUPPLIES FOR PRIMARY & SECONDARY SUBSTATIONS by disconnecting incoming & outgoing power supply, opening up, cleaning the battery bank, internally & externally, inspecting all the equipments,terminals, tightening all electrical connections, checking & cleaning , filling of D M water for battery, recording earth resistance complete through authorised service engineer of OEM (Original Equipment Manufacturer) all as specified & directed.
Material and labour for changing Silica gel breather assembly suitable for 11 KV,630 KVA cap outdoor step-down transformer all as per specified and directed.
Material and labour for changing Silica gel breather assembly suitable for 33 KV,2000 KVA cap outdoor step-down transformer all as per specified and directed.
ANKIT SHIP REPAIRERS AND SUPPLIERS
DURGAI ELECTRICALS
cooltech engineering services
M/S SANTOSH CONSTRUCTION CO
AGRAWAL ASSOCIATES
OM SAI POWER SYSTEMS
M/S Kumar Contractors
M/s SCHOLASTIC ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .