Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹11.8 L+₹86,223 (7.85%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L2 | Rejected-Finance Other Than L1 |
Tender Value
₹12.9 L
EMD Value
₹26,000
Closing Date
22 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cdr, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
Provn of visitor room in 3 Arty Bde, Three Phase Power Supply alongwith connected works and partitions for SML Room cum Trg Cell of 334 Msl Regt under GE 860 EWS
2023_MES_581424_1
138WE/L-76/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 860 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 860 EWS
₹26,000
Yes
27 Sept 2023
17 Feb 2023
29 Mar 2023
17 Feb 2023
22 Mar 2023
3 Mar 2023
Amount
Excavation in trenches n.exc 1.5M wide and n.exc 1.5M depth and n.exc 10 Sqm on plan and getting out in any kind of soilcomplete all as specified and as directed by the Engr-in-charge.
M & L for PCC 1:4:8 type D-2 ( Nominalmix) using 40 mm graded stone aggregate as in foundation filling and similar work complete.
M&L TMT bars 10mm dia and over in reinforcement cut to length bent to shape required incl hooking ends and binding with MS wire (annealed) not less than 0.9mm diacomplete all as specified and as directed by the Engr-in-charge.
M&L TMT bars for reinforcement 5mm to 10mm dia as in stirrups/spacers/binders etc. cut to length bent to shape required including bending cranking and hooking ends and binding with including MS wire not less than 0.9mm(annealed) dia complete all as specified and as directed by the Engr-in-charge.
M & L for providing RCC nominal mix Type B1 1:2:4 (20mm graded aggregate) Beams, cantilevers,and lintels over 1.5m span etccomplete all as specified and as directed by the Engr-in-charge.
M&L for formwork to sides of concrete roof beam, LBs sides and soffits (if any) of similar work; vertical or to batter for rough finished flat surfaces of concrete complete.
Returning filling in incl spreading leveling, watering, and well, ramming in layer nexc 25 cm in layers complete all as specified and as directed by the Engr-in-charge.
Removing excavated material to a distance n. exc50 m and depositing where directed at a level n. exc 1.50 m above the starting point.
M & L Precast cement concrete block masonry type C1 1:3:6 (20mm graded aggregate) with solid blocks, exc. 10cm in width and, setting in cement mortar 1:6 complete all as specified and as directed by the Engr-in-charge.
M&L for Rendering 10mm thick in cement mortar 1:6 on PCC block walling or concrete surfaces, finished even and smooth without using extra cement complete.
M&L for Rendering 15mm thick, in cement mortar 1:4 on PCC block walling or concrete surfaces and finished even and fair without using extra cement complete all as specified and as directed by the Engr-in-charge.
M&L Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface in broken stone or boulders complete all as specified and as directed by the Engr-in-charge.
M&L for Cement Concrete type C-2, 1:3:6 (20 mm graded aggregate) - 100mm thick as Sub base complete all as specified and as directed by the Engr-in-charge.
Material and labour for 25mm thick type B1 PCC 1:2:4 (20mm graded aggregate in sub base even smooth without using extra cement complete all as specified and as directed by the Engr-in-charge.
M&L for preparation of new plastered surfaces and apply two coats of cement base paint complete all as specified and as directed by the Engr-in-charge.
M&L for preparation surface and apply two coats of oil bond distemper over a coat of primer on newly plastered surface complete all as specified and as directed by the Engr-in-charge.
M&L for 75mm thick cement concrete 1:3:6 type C1 (using 20mm graded crushed stone aggregate) as in plinth protection complete all as specified and as directed by the Engr-in-charge.
S&F of pre- painted galvalume aluminum zinc coating GI based corrugated/ trapzodal, semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws / L-type or J-type or cranked hook bolts in lieu of screws with bituminious washer as specified and directed by Engr in Charge
S&F of steel work in tubular trusses inclulding special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161-1998 grade St-240 including steel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at contractor's workshop before fabrication complete all as specified and directed by Engr-in-Charge
M&L 5mm thick prelam PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining,Insulated PVC Wall Lining, and Solid PVC Cement and fixing at site.Partitions inclusive of Solvent Cement and fixing at site complete all as specified and as directed by the Engr-in-charge.M
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on wall to make PVC frame as per specification and drawing
M & L exposed metal frame ceiling with calcium Silicate board of 8mm silceous and calcareous material reinforced with cellulose fibre for fixing in 600mm X600mm grid (frame work for ceiling shall be measured and paid separately)
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified for size 605x605mm
S &F for anodised aluminium snap grid frame work for false ceiling size of grid 605x605mm all as all as specified and as directed by the Engr-in-charge.
S&F laminated flooring 8mm thick of any coloured manufactured by Direct pressure laminated (DPL) wherein the empty abrasive aluminium oxide overlay alongwith metamine impregnated decorated film is directly fused with the back with flooring locking profile in designed with double click locking system on the length and single locking width alongwith desire locking strength complete all as specified and directed by Engr in Charge
S&F aluminium anodised windows with side hung shutters / sliding shutters and frame made with aluminium section with and including glass/particle board 12mm thick (as specified below) Aluminium sections shall be of size as given below:- Frame : 44.5x44.5x1.60mm thick Top/bottom rail; 90x44.5mmx1.60mm thick side style/rails of shutter-44.5x44.5mmx1.60mm thick Glass : 5mm thick plain glass, sun control film fixed with rubber gasket with aluminium beading . Aluminium fitting such as peg stay, aluminium hinges, aluminium handle 100mm long, aluminium tower bolt 100mm long and making good of wall surface with matching to existing surface all as specified and as directed by the Engr-in-charge.
S&F aluminium anodised glazed door complete with shutter size of style top rail and lock rail 83x45x1.60mm thick and bottom rail 114x44x1.60mm thick and door frame size 63x38x1.60 mm including aluminium mongry fitting, hinges, tower bolt, handle, lock etc all necessary fittings and glazing with 5mm thick tinted glass/12mm thick pre laminated particle board complete including rubber lining at sides for air locking with & incl floor springall as specified and as directed by the Engr-in-charge.
S&F 4mm thick sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5sq. m in each pane complete all as specified and directed by Engr in Charge
Providing and fixing anodised aluminium work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and othersections of approved makeconforming to IS: 733 and IS:1285,fixing with dash fasteners ofrequired dia and size, includingnecessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed chanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P.brass/ stainless steel screws, all complete as per architectural drawings complete all as specified and as directed by the Engr-in-charge.
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge. Note : Punned thickness only to be measured.
Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 70 sq mm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as specified and directed by Engr-in-Charge.Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 63 Amps, 415 Volt, AC ,35 KA = 01 Nos (I/C) (b) MCCB 4 pole, 40 Amps, 415 Volt, AC ,35 KA = 02 Nos (O/G) (c) On load change over switch (side handled) 4 pole, 100 Amps, 415 Volt = 01 Nos Make : Havells (d) MCB SPN 63 Amps, 230 Voltst, AC = 2 Nos (O/G) (e) Multifunction meter MFM 440 LED meter Cl 0.5S with RS485 Make : L&T (f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
M&L Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
M&L Chemical Earthing complete with copper earth plate electrode 90 cm x 60 cm x 5 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Copper strip 50 x 6mm as earthing lead by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to Panels all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron strip 25×4mm as earthing lead included upto 7.5 mtr by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to Panels all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
M&L and labour for point wiring with 1.5 Sqmm copper conductor (Multi Standard) PVC insulated and unsheathed electric cable 1100 Volts in and including PVC casing and capping of 25mm and above (as per conducter run) with all fittings/accessories and including PVC insulated and unsheathed electric 1100 Volts 1.5 Sqmm (multi standard) copper conductor single core (Green Colour) cable as continuous earth wire connected to earth dolly incl 50mm deep box made of 2nd class hard board of required size and shape etc covered with 3mm thcik plastic laminated sheet for one light point/fan point independent controlled by one, one way switch complete all as specified and directed by Engineer-in-Charge. .
All as per Ser No 37 here-in-before but for one socket outlet 3pin, 5 Amps on independent board,
All as per Ser No 37 here-in-before but with 2.5 Sqmm FRLS copper wire with 1.5 sqmm FRLS copper earth wire for independent 15 Amp point. Note : The point wiring for power point will not be mixed with light/fan point circuit or not in the conduit pipe.
Supply and fixing switch piano flush button single pole one way 5 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing switch socket combination, two-in-one, 5 pin, 5 Amp universal type 230 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing switch socket combination, two-in-one, 6 pin, 5/15 Amp multipurpose shutter type 230 volts complete all as specified and directed by Engineer-in-Charge
Supply and fixing ceiling rose, surface bakelite, 65 x 50mm, three terminals complete all as specified and directed by Engineer-in-Charge
Supply and fixing LED lights fittings 1 x20w, 220V, AC decorative box type with driver, holder suitable size from ceiling rose complete.
Supply and fixing round shape 15 watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
M&L for sub main wiring 2 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main D, drawn in separate, ISI marked, non metallic, casing caping accessories & fittings/junction boxes/inspection covers etc with and incl cutting chasing and making good of distrubed surface of wall/floor/ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : 1. The cost of casing caping and accessories to be included in quoted rates. 2. The two run of 6 Sqmm wire and one run of 4 sqmm wire will be measured as one unit.
Supply and fixing sheet metal enclosure double shutter type for DB's 240 Volts single pole and neutral 4 way with 200 Amps rates bus bar complete including wooden board of required size duly painted with matching colour paint complete all as specified and directed by Engineer-in-Charge
Supply and fixing SPN 40 to 63 Amp rating 240V, 10 KA 'C' curve miniature, circuit breaker (MCB) of single pole and neutral in the MCB DB complete with connection testing and commissioning.
Supply and fixing SP 5 to 32 Amp rating 240V, 10 KA 'C' curve miniature, circuit breaker (MCB) of single pole and neutral in the MCB DB complete with connection testing and commissioning.
M/s Aman Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .