Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical ALL DOCUMENT ARE AS PER NIT DOCUMENT |
| 2 | Accepted-Technical | Accepted-Technical ALL DOCUMENT ARE AS PER NIT DOCUMENT |
| 3 | Accepted-Technical | Accepted-Technical ALL DOCUMENT ARE AS PER NIT DOCUMENT |
Tender Value
Refer Docs
EMD Value
₹20,341
Closing Date
8 Dec 2025, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SARPANCH GRAMPANCHAYAT
GRAMPANCHAYAT OFFICE SASPADE
Construction Of Grampanchayat Office Building at Saspade
2025_SATAR_1254048_1
1
Open Tender
Civil Works
Percentage
180 days
GP
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹20,341
Yes
10 Dec 2025
1 Dec 2025
9 Dec 2025
1 Dec 2025
8 Dec 2025
1 Dec 2025
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means Item / Page No : 2 / 153 Specification No : Bd.A.1 Spec. Page No : 259
Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foundations including necessary form work, compacting and curring, excetra complete. (with reversible drum type mixer without Supervisory Control and Data Acquisition with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 4 / 81 Specification No : CD.3 Spec. Page No : 160 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 31 / 179 Specification No : Bd.F.5, B-7 Spec. Page No : 300, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 50 / 181 Specification No : Bd.F.6, B-7 Spec. Page No : 300-301, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 1 / 197 Specification No : Bd.G.1 Spec. Page No : 313 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : Bd.G.5 Spec. Page No : 315 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
For Ground Floor Item / Page No : 5 / 197 Specification No : As per Item No 6a Spec. Page No : --- Additional Specifications : As per Item No 6a
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre placed at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 6 / 197 Specification No : Bd.G.7 Spec. Page No : 316 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing internal cement plaster 6 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 1 / 209 Specification No : Bd.L.1 Spec. Page No : 367 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 4 / 209 Specification No : Bd.L.2, Bd.L.10 Spec. Page No : 368, 370 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing waterproof plaster in water closet and bath 12 milimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of one kilogram per bag of cement of approved make and manufacturer and curing, excetra complete. (Excluding Tiles) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 6 / 205 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in charge. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 7 / 209 Specification No : Bd.L.4 Spec. Page No : 368 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying antiskid ceramic tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to Indian Standard 15622:2006 (Group BIIa) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 67 / 220 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying ceramic tiles of having sizes 30 centimetre X 60 centimetre and confirming to corrosponding Indian Standard for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 27 / 215 Specification No : Bd.M.13 Spec. Page No : 386 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 40 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 41 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edge
Metric Ton
per instructions of Engineer in charge.
Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For First Floor) Item / Page No : 2 / 264 Specification No : Bd.U.1 Spec. Page No : 537
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For First Floor) Item / Page No : 9 / 246 Specification No : Bd.T.34 Spec. Page No : 499
Providing and fixing 10 centimetre poly vinyl chloride nahani trap with grating, excetra complete. (For First Floor) Item / Page No : 67 / 281 Specification No : Bd.V.32A Spec. Page No : 551 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and constructing brick masonry inspection chamber 60 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation, 1:2:4 cement concrete channels, half round glazed stoneware pipes, brick masonary, plastering from inside and farme fixed in cement concrete Cover medium duty 140 kilogram with frame excetra complete. (using ARTIFICIAL SAND). Item / Page No : 12 / 275 Specification No : Bd.V.43 Spec. Page No : 574 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing, laying and fixing polyvinyl chloride pipe of 110 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete. Item / Page No : 28 / 277 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and fixing on walls / celling / floor, 20 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For First Floor) Item / Page No : 56 / 280 Specification No : Bd.V.5 Spec. Page No : 551 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and fixing on walls / celling / floor, 25 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For First Floor) Item / Page No : 57 / 280 Specification No : Bd.V.5 Spec. Page No : 551 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and fixing chromium plated two way bib cock of approved make including necessary sockets / union nut, excetra complete. (For First Floor) Item / Page No : 80 / 282 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing and fixing chromium plated bib cock with wall flange of approved make including necessary sockets / union nut, excetra complete. (For First Floor) Item / Page No : 83 / 283 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing and fixing Orissa type white glazed earrthenware 575 milimetre water closet pan including "S" trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall, 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories excetra complete. (For First Floor) Item / Page No : 30 / 277 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 11 / 209 Specification No : Bd.L.7 Spec. Page No : 369 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra comple
Compressive Strength of Cement Concrete Cube 1 Test for quantity upto 5 cubic metre, 2 Tests for quantity above 5 cubic metre and upto 15 cubic metre, 3 Tests for quantity above 15 cubic metre and upto 30 cubic metre, 4 Tests for quantity above 30 cubic metre and upto 50 cubic metre. For quantity 50 cubic metre and above - 4 Tests + 1 Test for each additional 50 cubic metre
Sieve Analysis Test for Metal 40 milimetre and above (Hand Broken) 1 Test per 200.00 Cubic Metre
Sieve Analysis Test for Metal below 40 milimetre 1 Test per 200.00 Cubic Metre
Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks 1 Test per 50000.00 Number
Compressive Strength of Cement Mortar 1 Test per Day
Water Absorption, Modulus of Rupture Test for Ceramic / Vitrified Tiles 1 Test per 2000.00 Number
Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend / Rebend Test, Proof Stress (Steel Bar upto 16 milimetre) 1 Test per 5.00 Metric Ton
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.07 MB
BOQ_2161711.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .