| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | ₹1.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.1 Cr+₹12.0 L (11.8%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | ₹1.1 Cr+₹12.0 L (11.8%) | L2 | Rejected-Finance Quoted amount higher than L1 |
| 3 | L3₹1.2 Cr+₹18.8 L (18.5%)Rejected-Finance CHAMAVILA CHEELI CHITTADI POST PALAKKAD DIST KERALA 678706 | PALAKKAD | KERALA | 678706 | ₹1.2 Cr+₹18.8 L (18.5%) | L3 | Rejected-Finance Quoted amount higher than L11 |
| 4 | L4₹1.3 Cr+₹25.7 L (25.3%)Rejected-Finance 16 176 A BHARATHI PURAM NAGAI NAGAR DINDUGUL 3 | DINDUGUL | DINDIGUL | TAMIL NADU | ₹1.3 Cr+₹25.7 L (25.3%) | L4 | Rejected-Finance Quoted amount higher than L1 |
| 5 | L5₹1.3 Cr+₹27.2 L (26.8%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹1.3 Cr+₹27.2 L (26.8%) | L5 | Rejected-Finance Quoted amount higher than L1 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
1 May 2024, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
Spl repair to Bldg No P142 and dining hall in officers Mess and toilets sheds in annexes and hard standing behind LCA hanger near Admin complex replacement to BER Air conditioner and LT UG cables and connected works at AFS Sulur
2024_MES_650299_1
CWE(AF)/TVM/82503 E8 Spl repair Sulur
Open Tender
Civil Works
Item Rate
90 days
Sulur
Class B category a(i)
6 documents required · 6 mandatory
₹1,000
GE AF Sulur
₹2.2 L
Yes
17 May 2024
17 Apr 2024
3 May 2024
17 Apr 2024
1 May 2024
24 Apr 2024
17 Apr 2024 - 23 Apr 2024
Amount
SCHEDULE 'A'
Taking down chowkats or frames with shutter n.exc 1.5 Sqm each without taking off shutter from the frame.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, includingcover fillets
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Demolition of cement concrete(reinforced) of any description and in any position not otherwise specifically provided for
M&L Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed
Demolition of brick work masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any soft/ hard soil.
Removing excavated material n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified.
M&L Cement concrete PCC 1:4:8 Type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete
M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width type C-1 1:3:6 using 20mm graded stone aggregate and setting in mortar 1:6 straight or curved on plan exc 6m mean radius, built in cement mortar 1:6
M&L for rendering 10mm thick on fair face of brick-work or concrete surface in cement mortar 1:4 and rendering is to be finished even and smooth (without using extra lime or cement)
M&L Preparing new surfaces of plastered or unplastered wall and applying two of oil bound destemper over providing over plaster of paris putty of 2 mm thickness over alkali resistant priming paint over 2mm thick plaster of paris putty over plastered surfaces to prepare the surface even and smooth.
M&L Rendering 15mm thick on surface other than fair face of brick-work or on one side of lathing in cement mortar 1:4 and rendering is to be finished even and smooth (without using extra lime or cement)
M&L Preparing new surfaces of plastered or unplastered wall and applying two coats of cement based paint over a coat of alkali resistant primer complete.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M&L Reinforced cement concrete (nominal mix Type A 1:1.5:3 (20mm graded stone aggregate)) as in Beams, cantilevers, bressummers, lintels over 1.5m span
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of concrete.
M&L Reinforced cement concrete ((nominal mix Type A 1:1.5:3 (20mm graded stone aggregate)) as in Chajjas
M&L Reinforced cement concrete (nominal mix Type A 1:1.5:3 (20mm graded stone aggregate)) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete.
S&F 12mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required.
Hardcore of broken stone/boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L 100mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) under floors
M&L Vitrified Ceramic tiles 10 mm thick, LIGHT shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer, 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M&L Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:3 complete all as specified and as directed.
M&L 75mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded stone aggregates), as in Plinth protection/ Path including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
S&F Steel work in tubular trusses and columns including special shaped washer etc complete using ERW or induction butt,welded tubes conforming to IS 1161-1979 grade ST-240 complete all as specified
S&F Framed brackets of angles or tees with web and flanges cutshape, drilled and countersunkfor screw, including bending and welding angles, as necessary,gusset plates, riveting, etc.. n exc10 kg each brackets, conformingto Fe.290.Gde-E-16(Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified
M&L Pre painted Coloured corrugated Galvalume roofing sheet 0.50 mm thick having Zinc aluminum alloy coating any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as directed.
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted , bolted or welded attachment.(Fe 410 -W (Gde- E-250) quality -A complete steel all as specified
M&L MS Plates (Plain or chequered) channels (confirming to Fe 410 W Gde E-250 A quality), square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment including dismantling existing steel complete all as specified and as directed
M&L for Joist, channel, angle, or tee sections, fixed independently (confirming to Fe 410 W Gde E-250 A quality), without connecting plates, etc. including dismantling existing steel complete all as specified and as directed
M&L for preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
M&L False ceiling using GI snap grid size 60x60cm with main runner 38x24,wall angle & cross tee 29x24mm wall angle 24x24mm suspended with 4mm dia GI Wire fixed with steel dash fasteners carrying max load upto 8.1 Kg/Sqcm with 4mm thick designer ceiling board Including taking down existing one complete all as specified and as directed by Engineer-in-Charge.
Aluminium powder coated of three track sliding window outer frame top & sides (section no-20831) of size 92.0x31.75x1.5mm weighing 1.06 Kg/m, frame bottom (Section No 20832) of size 92.0x31.75x1.5mm weighing 1.248Kg/m , shutter to plain vertical (Section No 21093) of size 39x18x1.5mm weighing 0.634 Kg/m, shutter interlock vertical frame (section 21094) of size 39x18x1.55 weighing 0.734 Kg/m, shutter bottom horizontal frame (Section No 20551) size 40x20x1.5mm weighing 0.484 Kg/m, with powder coating of min thickness 50 micron , sliding type with out sash bars, 4mm thickness colour glass, rubber packing, snap beading screws with stainless steel wire mesh, completet all as specified
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n exc 5cm long diameter of neck 5 to 10mm icomplete all as specified and directed.
S&F MS flat iron wind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc. , and similar work conforming to Fe-290 Gde E-165 all as specified and as directed.
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L Preparation of new steel surface of any description n. exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L Polythene film, 150 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m all as specified and directed
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
M&L In cement concrete 1:2:4, type B-0 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary formwork all as specified and directed
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thickwalls built in CM 1: 4 complete all as specified and directed.
S & F Powder coated aluminium door shutters,aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each doors, hinges anodised aluminium snap beading screws etc including taking down existing one complete all as specified and directed. Note:-Glazing and particle board work shall be measured and paid seperately.
S & F 9mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination fixed with screws to aluminium frame including taking down existing one complete all as specified and as directed.
S & F Coloured tinted float glass and glazing, 5.5 mm thick with oil putty in squares not exceeding 0.5 Sq.m in each pane, with glazing clips and oil putty, including taking down existing one complete all as specified and directed.
S & F Mortice lock brass 4 levers vertical type of size 100mm fixed as including taking down existing one all as specified and directed.
S&F Aluminium extruded section body door closer hydraulically regulated,designation No.3, universal type, suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 kg and fixed including taking existing one complete as directed by Engr-in-charge.
Taking down chowkhat or frame(wooden/steel) exceeding 1.50 Sqm not exceeding 4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
M & L Cutting holes in brick wall exc half brick and n.exc one brick in cement mortar for inserting hold fasts/lugs and making good dismantled portion in cement mortar 1:3 or 1:2:4 type B-1 concrete as required complete all as specified and as directed.
S&F MS work (flat iron) 25mm x 3mm thick, in small articles such as hold fast and similar small articles conforming to Fe 290 Gde E-165 including taking down existing one complete all as directed.
M&L Complete removal of existing finishes on plastered wall surfaces and applying two coats of oil bound distemper over a coat of primer including two coats of putty [as 1st coat of putty (1.50mm thickness) and 2nd coat of wall putty (1.0 mm thickness)] all as specified and directed.
M&L for preparation of new texture painting to walls Royale Glitz Luxury Emulsion is an ultra sheen interior paint which provides a rich luxirious finish to walls. It also offers unmatched stain repellency to keep the walls beautiful. It provides Luxury with Teflon combination the best of decor and performence design complete all as specified and as directed by Engr-in-charge.
M&L Removal of existing treatment,cleaning the existing surface with wire brush and water completely, including preparation and applying two coats of cement base paint over a coat of primer on external surfaces of wall and curing to CBP upto required period complete all as specified and as directed.
S&F of 3 to 6mm thick any colour or any design PVDF coating Aluminium Composite Panel for Exterior walls and gates(fire proof, Mould Proof etc.
M&L Framed work such as grills, gratings, angles etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of static water tanks and similar work con- forming to Fe.290.Gde-E-165 including dismantling/ taking down existing framed work complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Mild steel black sheet 0.80mm thick in wall cladding, steel gates and similar works, cut to size, holes punched including round headed screws, clout nails for rebates and fixed to steel framing with plain 40mm lap joints with rebated or weilded seams including bending or turning up mitred angles etc as required complete all as specified and as directed.
M&L Brick work with modular flyash bricks, straight or curved on plan to any radius, built in cement mortar 1:4 complete all as specified and as directed
M&L Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement including taking down existing cement plaster and removal of debris outside MD land complete all as specified and as directed
M&L Rendering 5 mm thick cement plaster on concrete surface in CM 1:4 finished even and smooth without using extra cement including taking down existing cement plaster and removal of debris outside MD land complete all as specified and as directed
M&L Preparing new surfaces of plastered or unplastered wall and applying three coats of white wash complete all as specified and as directed
M&L Preparing new surfaces of plastered or unplastered ceilling and applying three coats of white wash complete all as specified and as directed
M&L Granite 18 to 20mm thick (table rubbed and polished) in steps, Jambs, Pillars, Windows, cills, platforms and like CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with marble shade of Granite over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) all as specified and as directed Incl demolition of stone slabs
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, M&L Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectaangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified and as directed
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, M&L Glazed ceramic coloured tiles in vertical surface 350x250x7 mm/450x350x7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match including 10mm thick backing coat in CM 1:4 complete all as specified and as directed
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed.
S&F Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded both side prelaminated PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelaminated PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of both side prelaminated PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and as directed (Stile and rails feathered at edges)
S & F 100mm long Butt hinges medium weight cold rolled stainless steel, and fixed complete all as specified and as directed.
S&F 150 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed
S&F 125mm extruded aluminum alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast- aluminum alloy and fixed complete all as specified and as directed.
S&F in repair Vitreous china wash down water closet pan (pedestal pattern) white with fixing bolts including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and as directed
S&F in repair PVC valveless syphonic action type flushing cistern,10 Ltr capacity low level white with inlet ball valve, float and handle including brackets and Flush pipe of polyethylene of low or high density of PVC 32 mm dia, for low level cistern complete all as specified and as directed
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified
S&F in repairs Toilet paper holder with flat recessed type stainless steel complete all as specified and as directed
S&F CP 2 way bib cock with wall flange fancy type screwed down screwed for iron pipe in repairs 15mm bore CAT Part No-QT F2006163, HT 3001163 of CERA or equivalent in Parryware ,or as per list of makes Including taking down existing one complete all as specified and as directed by Engineer-in-Charge
S&F in repair Vitreous China wash basin, white, flat back, size 550 x 400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and as directed
S&F in repairs vitreous china urinals bowl type urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws pointing around urinal back with cement (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
S & F in repairs Chromium plated urinal spreader suitable for 15mm bore pipe complete all as specified and directed.
S&F in repair Bib tap of 15mm bore dia cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed
S&F in repair 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed
S&F in repair Pillar tap 15 mm dia bore cast copper alloy, with capstain heads, chromium plated, fancy type screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed
S&F in repair Stop valves 15 mm dia bore fancy type chromium plated screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed
M&L in repairs grating doom 125mm dia with waste hole of PTMT(minimum weight 40gms) Including taking down existing one complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F in repairs Chromium plated brass shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed
S&F in repairs Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour (Minimum weight 40gms) complete all as specified and as directed
S&F in repairs CP Soap dish CAT Part No- F 5007106 of CERA or equivalent make of Parryware /Hindware complete all as specified and as directed.
S&F in repairs Vitreous china urinal partition white of size 310x770 mm complete all as specified and as directed
M&L in repair PVC (SWR) floor trap (dia of outlet 75mm), plain with grating including jointing with solvent cement complete all as specified and as directed
S&F in repairs aluminium anodised ventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members and half portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass incl necessary channel frame work, including rubber gasket and aluminium beading complete all as specified and as directed
S&F 3-layer 25 mm PP-R poly propylene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls ceilings or in floors etc complete all as specified and as directed
Taking up or down steel tubing of 15mm bore and connections, including cleaning for refixing or removal to store complete all as specified and as directed
S&F in repairs 25mm outer dia of pipe PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed
S&F PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
S&F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
S&F in repairs 75mm dia PVC (SWR) bends any radius complete all as specified and as directed
S&F in repairs 110mm dia PVC (SWR) bends any radius complete all as specified and as directed
S&F in repairs 110mm dia PVC (SWR) vent cowl complete all as specified and as directed
S&F in repairs 75mm dia PVC (SWR) junction single, (single T), equal or unequal complete all as specified and as directed
S&F in repairs 110mm dia PVC (SWR) junction single, (single T), equal or unequal complete all as specified and as directed
S&F in repairs Brass chromium plated bottle traps 32mm bore dia for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed
Excavating in post holes (or similar holes) each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good surface as in hard / dense soil complete all as specified and as directed.
M&L Hardcore of gauge of broken stone or boulders n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed
M&L 75mm thick PCC 1:4:8 type D2 (using 40mm aggregate) and making surface even and fair without using extra cement complete all as specified and as directed
M&L 100mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates), as in hardstanding including making joints @ 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as per specified and as directed. Note :-The rate is deemed to be included for the supply of additional qty of sand from out side MD land In case sufficient sand not obtained from excavation as directed by the Engineer-in-Charge.
S&F Fly ash bricks using modular bricks as in cable protection cover including taking down existing bricks of any size complete all as per specified and as directed.
M & L Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed. The quoted rates include the following:- (i) Earth work excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (iii) Removing excavated material to out side MD land (iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 as in road
Supply only GI pipe 80 mm bore Light grade for cable protection complete all as specified and as dierced by Engr-in-Charge.
Supply only GI pipe 100 mm bore Light grade for cable protection complete all as specified and as dierced by Engr-in-Charge.
S & F XLPE insulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 150 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
S & F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 120 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
S & F XLPE insulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 95 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
S & F XLPE insulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
S & F XLPE insulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 70 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
S & F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note for item No. 125to 129 :- Necessary excavation and earth work, sand cushioning & bricks for protection shall be measured and paid separately.
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed. Note (a) All Joints should be joined by Exothermic Welding or Brazing. (b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab. (d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Earth continuity conductor or main earthing lead fixed to wall on batten ground or drawn in conduit/pipe or or recess or chases or buried in fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR complete all as specified and as directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2 of capacity 2 TR complete all as specified and as directed.
Supply and fixing in replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5 % and capacity 4 KVA complete all as specified and as directed.
Supply and fixing in replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5 % and capacity 5 KVA.complete all as specified and as directed.
Sub main wiring with 2 runs of 4 sqmm PVC insulated unsheathed 1100 volts grade multi stranded copper conductor cable in and incl non metallic rigid PVC conduit/ casing caping with all accessories fixed to wall /roof/ ceiling/floors along with 4 sqmm PVC insulated unsheathed copper ondutor multi stranded cable 1100V grade as earth contuity conductor and connected to common earth dolly. Note: 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and PVC conduit/casing caping shall be measured as one length.
S&F metal clad socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps complete all as specified and as directed.
Supply and fixing on distribution boards including replacement of single pole MCB 10 to 32 Amps, 240V, 50 Hz AC suitable for 'C' curve, 10 KA breaking capacity conforming to IS 8828 of 1996 as as specified.
Supply and fixing of SPN distribution board 4 waywith 200 Amps rated bus bar fabricated through sheet metal enclosures.
Total of Schedule 'A'
KUMAR AGENCIES
jk construction
S KUMARAN
Lucky Enterprises
A.GOVINDARAJ
P Natesan and Co
S.RAMACHANDRAN
KRISHNA ENTERPRISES
K S MUTHU CONSTRUCTTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .