Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹40.2 L Quoted ₹41.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹46.9 LRejected-AOC SUMOHAN STATION ROAD MAKERI KARWAR UK KARNATAKA 581 306 | KARWAR | UTTARA KANNADA | KARNATAKA | 581306 | ₹46.9 L | L2 | Rejected-AOC Not Being L1 |
| 3 | L3₹47.3 LRejected-AOC FLAT NO 1004 BUILDING NO L 11 KEDAR HOUSING SOCIETY 10TH FLOOR SECTOR NO 21 TALOJA PHASE 2 PANVEL RAIGAD NAVI MUMBAI 410208 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410208 | ₹47.3 L | L3 | Rejected-AOC Not Being L1 |
| 4 | L4₹49.0 LRejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹49.0 L | L4 | Rejected-AOC Not Being L1 |
| 5 | 65₹50.0 LRejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHATRAPATI SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKTA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹50.0 L | 65 | Rejected-AOC Not Being L1 |
| Sl No | Description | Qty | Unit | sanjay prabhu L2 | Shree Ayyappa Engineering L4 | cooltech engineering services L5 | M/s ASPIRE ENGINEERING ENTERPRISES L3 | shakti engineering and electrical works L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for yearly Inspection of cranes by checking & testing all parts /safety device including Load testing and provide inspection report /certificate from authorised rep(crane inspector) complete all as specified for the Electrically operated Overhead Traverse crane with the testing load as recommended by OEM for the rated tonnage of crane for the specific period with and including arrangement for safe test load for 3 to 5 ton cranes for 04 nos of cranes. Note :- Load testing is inclusive of shiffting /Transporting the load place to place, unloading will be arranged by the contractor including required ropes,manpower etc for handilling the load. | 1 | Each Job | 20,300 ₹20,300 | 21,000 ₹21,000 | 21,400 ₹21,400 | 20,440 ₹20,440 | 17,900 ₹17,900 |
| 2.00 | Material and labour for Painting of 3 to 5 ton cranes for 4 nos of cranes with two coat of synthetic enamel yellow paint after cleaning and scraping of old paint, oil, rust etc complete including writing SM Nos with white synthetic enameled paint complete all as per specified as directed by Engineer - in - charge. | 4 | Each Job | 1,523 ₹6,092 | 1,575 ₹6,300 | 1,605 ₹6,420 | 1,533 ₹6,132 | 1,343 ₹5,372 |
| 3.00 | M&L for yearly Inspection of cranes by checking & testing all parts /seafty deviceincluding Load testing and provide inspection report /certificate from authorised rep complete all as specified for the Electrically operated Overhead Traverse crane complete with the testing load as recommended by OEM for the rated tonnage of crane for the specific period complete with and including arrangement for safe test load for 0.5 to 2.0 ton cranes for 18 nos cranes. Note :- Load testing is inclusive of shiffting /Transporting the load place to place, unloading will be arranged by the contractor including required ropes,manpower etc for handilling the load. | 1 | Each Job | 30,450 ₹30,450 | 31,500 ₹31,500 | 32,100 ₹32,100 | 30,500 ₹30,500 | 26,850 ₹26,850 |
| 4.00 | Material and labour for Painting of 0.5 to 2 ton cranes for 18 nos of cranes with two coat of synthetic enamel yellow paint after cleaning and scraping of old paint, oil, rust etc complete including writing SM Nos with white synthetic enameled paint complete all as per specified as directed by Engineer - in - charge. | 18 | Each Job | 1,015 ₹18,270 | 1,050 ₹18,900 | 1,070 ₹19,260 | 1,008 ₹18,144 | 895 ₹16,110 |
| 5.00 | Repair maintenance of electrically operated travelling (EOT/HOT) cranes, once in a month of crane up to 60 mtr span, 0.5 ton to 5 ton capacity, medium duty floor operated comprising of Hoist motor ,micro motor , long travell motor, cross travell motor, gear box, control panel etc, installed as per list attached - 22 Nos ( Appx 'A') including carry out daily check and periodical services as per Appx'B' attached ,repair /maintenance of unserviceable damaged parts such as bearing bushes all type of shoes headers, control cards, connector/ links, wielding of crack/ broken MS Parts, safety parts, mechanically safety lock , Control push button assembly including all connected accessories complete with push button ,inclusive repair of harness wiring of control panel , minor repair to panel ,for safety and smooth functioning of Cranes, cutting wall making good disturbed surface with masonry work to make the existing surface, cable as per requirement or safety operation of cranes, maintenance of unserviceable /worn out parts such as warm wheel, warm shaft, bushes, thrust bearing and necessary packing including cleaning, alignment of gear box assembly after repair/replacement of worn-out parts re-assemble and fixing with existing machine with proper alignment complete maintenance, binding of loose wire at control panel and painting to rust portion of crane. | 11 | Each month | 17,815 ₹2.0 L | 18,900 ₹2.1 L | 19,260 ₹2.1 L | 18,176 ₹2.0 L | 16,000 ₹1.8 L |
| 6.00 | Supply and fixing Control contactors ,TP,415V, capacity 9 to18 amps (Type MNX 09-18 ) of L&T or equivalent Make in Legrand & Siemens. | 4 | Each | 855 ₹3,420 | 1,418 ₹5,672 | 1,445 ₹5,780 | 1,380 ₹5,520 | 1,208 ₹4,832 |
| 7.00 | Supply and fixing Control contactors ,TP,415V, capacity 32 to 45 amps, Type MNX 32-45 of L&T or equivalent Make in Legrand & Siemens. | 4 | Each | 2,913 ₹11,652 | 3,014 ₹12,056 | 3,071 ₹12,284 | 2,206 ₹8,824 | 2,569 ₹10,276 |
| 8.00 | Supply and fixing Over load protection relay, 3 phase, 415 V ratings 6 to 15 amps Type MN 2 of L&T or equivalent Make in Legrand & Siemens. | 4 | Each | 800 ₹3,200 | 1,314 ₹5,256 | 1,339 ₹5,356 | 1,279 ₹5,116 | 1,120 ₹4,480 |
| 9.00 | Supply and fixing Over load protection relay, 3 phase, 415 V ratings 20 to 32 amps Type MN 2 of L&T or equivalent Make in Legrand & Siemens. | 4 | Each | 3,654 ₹14,616 | 3,780 ₹15,120 | 3,852 ₹15,408 | 3,679 ₹14,716 | 3,222 ₹12,888 |
| 10.00 | Supply and fixing Over load protection relay, 3 phase, 415 V ratings 30 to 50 amps Type MN 5 of L&T or equivalent Make in Legrand & Siemens. | 4 | Each | 3,908 ₹15,632 | 4,043 ₹16,172 | 4,120 ₹16,480 | 3,935 ₹15,740 | 3,446 ₹13,784 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
9 Feb 2026, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR/MAINT OF EOT/HOT CRANES, LIFTS, BOOM BARRIER, MOTORISED DOOR OF VARIOUS HANGERS AND DG SET, AMF PANEL, OTHER MISC WORKS AT DIFFERENT LOCATION, FIRE ALARM SYSTEM, CONTROL PANELS, MAINT OF ETP ETC AT TECH AREA AND MISC WORKS AT 1BRD AF STN OJHAR
2026_MES_749429_1
8375/E8
Open Tender
Electrical and Maintenance Works
335 days
Ojhar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹90,000
Yes
9 May 2026
21 Jan 2026
11 Feb 2026
22 Jan 2026
9 Feb 2026
2 Feb 2026
M&L for yearly Inspection of cranes by checking & testing all parts /safety device including Load testing and provide inspection report /certificate from authorised rep(crane inspector) complete all as specified for the Electrically operated Overhead Traverse crane with the testing load as recommended by OEM for the rated tonnage of crane for the specific period with and including arrangement for safe test load for 3 to 5 ton cranes for 04 nos of cranes. Note :- Load testing is inclusive of shiffting /Transporting the load place to place, unloading will be arranged by the contractor including required ropes,manpower etc for handilling the load.
Material and labour for Painting of 3 to 5 ton cranes for 4 nos of cranes with two coat of synthetic enamel yellow paint after cleaning and scraping of old paint, oil, rust etc complete including writing SM Nos with white synthetic enameled paint complete all as per specified as directed by Engineer - in - charge.
M&L for yearly Inspection of cranes by checking & testing all parts /seafty deviceincluding Load testing and provide inspection report /certificate from authorised rep complete all as specified for the Electrically operated Overhead Traverse crane complete with the testing load as recommended by OEM for the rated tonnage of crane for the specific period complete with and including arrangement for safe test load for 0.5 to 2.0 ton cranes for 18 nos cranes. Note :- Load testing is inclusive of shiffting /Transporting the load place to place, unloading will be arranged by the contractor including required ropes,manpower etc for handilling the load.
Material and labour for Painting of 0.5 to 2 ton cranes for 18 nos of cranes with two coat of synthetic enamel yellow paint after cleaning and scraping of old paint, oil, rust etc complete including writing SM Nos with white synthetic enameled paint complete all as per specified as directed by Engineer - in - charge.
Repair maintenance of electrically operated travelling (EOT/HOT) cranes, once in a month of crane up to 60 mtr span, 0.5 ton to 5 ton capacity, medium duty floor operated comprising of Hoist motor ,micro motor , long travell motor, cross travell motor, gear box, control panel etc, installed as per list attached - 22 Nos ( Appx 'A') including carry out daily check and periodical services as per Appx'B' attached ,repair /maintenance of unserviceable damaged parts such as bearing bushes all type of shoes headers, control cards, connector/ links, wielding of crack/ broken MS Parts, safety parts, mechanically safety lock , Control push button assembly including all connected accessories complete with push button ,inclusive repair of harness wiring of control panel , minor repair to panel ,for safety and smooth functioning of Cranes, cutting wall making good disturbed surface with masonry work to make the existing surface, cable as per requirement or safety operation of cranes, maintenance of unserviceable /worn out parts such as warm wheel, warm shaft, bushes, thrust bearing and necessary packing including cleaning, alignment of gear box assembly after repair/replacement of worn-out parts re-assemble and fixing with existing machine with proper alignment complete maintenance, binding of loose wire at control panel and painting to rust portion of crane.
Supply and fixing Control contactors ,TP,415V, capacity 9 to18 amps (Type MNX 09-18 ) of L&T or equivalent Make in Legrand & Siemens.
Supply and fixing Control contactors ,TP,415V, capacity 32 to 45 amps, Type MNX 32-45 of L&T or equivalent Make in Legrand & Siemens.
Supply and fixing Over load protection relay, 3 phase, 415 V ratings 6 to 15 amps Type MN 2 of L&T or equivalent Make in Legrand & Siemens.
Supply and fixing Over load protection relay, 3 phase, 415 V ratings 20 to 32 amps Type MN 2 of L&T or equivalent Make in Legrand & Siemens.
Supply and fixing Over load protection relay, 3 phase, 415 V ratings 30 to 50 amps Type MN 5 of L&T or equivalent Make in Legrand & Siemens.
Supply and fixing main power contactor Type ML- 1.5, 25 amps of L&T or equivalent Make in Legrand & Siemens.
Supply and fixing only main power contactor Type ML- 2, 32 amps of L&T or equivalent Make in Legrand & Siemens.
Supply and fixing main power contactor Type ML - 3, 40 amps of L&T or equivalent Make in Legrand & Siemens.
Supply and fixing relays Over load protection relay, 3 phase, 415 V ratings 6 to 10 amps Type ML 1.5 Contactors of L&T or equivalent Make in Legrand & Siemens.
Supply and fixing relays Over load protection relay, 3 phase, 415 V ratings 13 to 21 amps Type ML 3 Contactors of L&T or equivalent Make in Legrand & Siemens.
Supply and fixing Add on aux contact block MNX 9-80 A of L&T or equivalent Make in Legrand & Siemens.
Supply and fixing Brake shoes suitable for 3 to 5 ton crane Make-L&T/Siemens/BCH
Supply and fixing Brake shoes suitable for 0.5 to2 ton crane
Supply and fixing solinoid coil / oil immersed magnetic coil for 3 to 5 ton crane of any make
Supply and fixing solinoid coil / oil immersed magnetic coil for 0.5 to2 ton crane of any make
Supply and fixing push button switch for EOT crane with element 6 Amp 415 Volt 50 Hz (with 2 push button).
Supply and fixing push button switch for EOT crane with element 6 Amp 415 Volt 50 Hz.(with 4 push button).
Supply and fixing indicating lamp LED type R,Y & B colours.
Overhauling of the gear box assy of 3 to 5 ton capacity crane after cleaning and draining the gear oil, checking the gears, shaft, and replacement of worn out bushes, nuts bolts of the couplings, studs,gear and brake liner set , new gasket / oil paper if reqd and refilling the gear box with new gear oil upto the capacity brought in sealed container. Spreading out steel rope in the shell sequentially, physical checking of leads for damage or abbression, after cleaning with linament, lubricating the steel rope, cleaning the drum and sheaves streaching the rope and testing for functioning without crese, abression, and jerk.
Repair/maintenance of control Panel of crane by taking down unserviceable cut outs, relays, contactors, connectors, control wiring, and cleaning the surfaces, supply and fix new set of cut outs, control contactors, and relays for the operation of the crane complete and rewiring with 2.5 sq mm copper conductor stranded insulated and unsheathed flexible cable including maintaining the sequence and synchronising of movements complete all as specified and as directed
Taking down unserviseable damaged trolly connection cable complete with steel wire and reel insulator, supply, fix and connect stranded copper cable pvc insulated pvc sheathed unarmoured 1100 volts grade 1.5 sqmm 12 to 16 core complete with new reel insulators complete all as specified and directed.
Taking down unserviseable damaged trolly connection cable complete with steel wire and reel insulator, supply, fix and connect stranded copper cable pvc insulated pvc sheathed unarmoured 1100 volts grade 2.5 sqmm 3 core complete with new reel insulators fixing at lift, hanger door and crane complete all as specified and directed.
Supply & fix Steel Wire Rope of 8 mm dia. Make:- Usha Martin
Supply & fix Steel Wire Rope of 10 mm dia. Make:- Usha Martin
Supply & fix Steel Wire Rope of 12 mm dia. Make:- Usha Martin
Supply and fixing in repair limit switch with 2/4 contacts rated 40 amps upto 500 V,AC with suitable IP protection of dust/vermin.
S&F in repair DSL safe track link with insulation sleev for 0.5 Ton to 5 Ton crane at various bays.
S&F in repair PCB as per existing with all connections suitable for all operations of crane travels for 3 Ton to 5 Ton at various Hanger.
Taking down existing unsv electric motor 3 phase, 415 volts, 50 HZ , capacity 4 to 7 KW motor of any make from the Crane/ motorised Gate/Lift after disconnecting all electrical connection and shift to workshop for repair. Dismantling the motor , removing old burnt winding, cleaning the slots, checking and setting the stampings, providing a coat of insulating warnish, rewinding with super enamelled copper conductor winding wire of suitable gauge, packing the slots with insulating sleeves. drying in controlled temperature, re-assembling the motor with new set of bearings and connecting with its original place of the crane /motorised door /lifts.
All as per item no-34 but 3 phase, 415 volts, 50 HZ , capacity 1.5 to 3 KW motor of any make
All as per item no-34 but 3 phase, 415 volts, 50 HZ , capacity 0.5 to 1 KW motor of any make
Supply and fixing in replacement complete gearbox assembly with 5 HP electric motor and brake shoe, suitable for crane duty operations. Includes electromagnetic/AC/DC brake shoe, coupling, mounting base, bearing housing, input/output shafts, oil filling, lubrication, alignment, and all necessary hardware and all electrical and mechanical connections, wiring to control panel, brake rectifier (if DC brake), terminal box, complete all as specified and directed by Engg.in charge
Supply, install, test, and commission a complete VFD control panel for 5-ton overhead crane, including metal enclosure, VFD unit, contactors, MPCBs, thermal overload relays, control transformers, control push-button stations, power wiring, control wiring, interlocking wiring, terminal blocks, busbars, cable glands, labeling, internal wiring accessories, and any additional components required for proper operation. Includes connection to motor(s), limit switches, pendant controls/radio remote controls, safety interlocks, braking arrangements, and integration with crane electrical system and complete all as specified and directed by Engg.in charge
Supply and fixing PVC flexible copper cable multistranded 4 core 2.5 sqmm fixed with wall with suitable size of clamp complete all as specified and as directed by engr-in-charge.
Repair maintenance of motorised hanger door /sliding gate( As per Appx 'B' ) including carry out daily check and periodical services once in a month of electrically operated hanger door with repair /maintenance of auxilary components gear box assembly, lifting mechanism control PCB panel board and repairs/replacement of contractor 240V, 32A, limit switch, reverse/forward switch AC 240V,50 Hz as per sample also replacement of rack and pinion to the length as per existing including lubracating all moving parts, unserviceable damaged parts such as bearing bushes, welding of crack/ broken MS Parts complete re-assimbling and refixing and setting for smoth operation with the help of remote or On/Off switch complete all as specified and directed. Note:-
Taking down reduction gear arrangement of motorised hanger door after disconnecting the elecrical connections and shifting to civil work shop for repairs / overhaul. Dismantling the reduction gear assembly, separating gears and shaft. Cleaning the shell, shaft and gears fixing back gears on the shaft including repacement of worn out or unservieable gears/doing required fabrication and applying the proper grade of lubricant. Opening the outer cover of the induction motor, cleaning the internals including the old lubricants; refixing the electric motor after replacing the dameged parts lubricating and connecting up after replcement of necessary spares. Note:- Spares as required for replacement in the process of repair/overhaul will be measured and paid separatly under the relevent item here in after.
Supply only Spur gear ( driven shaft ).
Supply only Driving chain with 30 mm pitch not less than 10 mm dia with 25 mm wide links and minimum of 2250 mm length complete with locking links and arrangements all as per the existing
Supply only Sprocket wheel fixed complete on the drive shaft all as per existing.
Supply only Coupling for the motor and worm reduction gear shaft complete with rubber, PVC, neopphrin packing, spider & locking/split pin complete all as specified.
Supply only Ball bearing all as per sample for sliding the heavy duty gate 13to 15 mtr high, Make SKF/NBC/TATA
Supply only Supply only the main shaft of gear assembly copuled with motor as per existing complete all as specified.
S&F in repairs Handle Assembly for operation of geared drive for standby operation of door closing system coupled to the motor operated reduction gear arrangement. The system speed on handle operation shall be one cycle for every rotation of handle and not less than the driven wheel all as per existing.
Repair/maintenance of control Panel of Motorised hanger door by taking down unserviceable cut outs, relays, contactors, connectors, control wiring, and cleaning the surface, supply and fix new set of cut outs, control contactors, and relays if reqd for the smooth operation of the Motorised hanger door complete and rewiring with 2.5 sq mm copper conductor stranded insulated and unsheathed flexible cable including maintaining the sequence and synchronising of movements complete all as specified and as directed
S&F in repairs mild steel corrugated Black sheet in wall clading, steel gates and simlar work, cut to size, holes punched; including round headed screw, clout nails or rebates and fixed to wood or steel framing with plane 40 mm lape joint with rebated or welded seams, including bending or turning up, matired angles, etc of thickness 0.8mm complete including painting inside and outside with two coat of aluminium paint all as specified and as required.
Supply and fixing complete hangar door panels, including fabrication, structural framing, cladding, insulation, weather seals, glazing (if applicable), operating hardware, electrical control system, safety devices, brackets, corrosion protection, finishing, testing, adjustments, and all associated accessories and components necessary to complete and fully operational system, all as directed by engg-in-charge.
Supply and fixing 3HP Electric motor with gear box , shaft, chain, break shoe etc all connected itemsor vertical gear motor with RPM 750/900 and secondary speed 100-10,for hanger doors.
Supply and fixing Door Wheel 9"with chin rachet for hanger doors
Supply and fixing starter panel for control door control panel with 32 Amp MCB & indicator 4 MI starter relay 3.59Amp for hanger doors
Supply and fixing limit switch for hanger doors
M & L for cement concrete 1:2:4 nominal mix type B1 using 20mm graded stone aggregate in foundations, filling and mass concrete.Complete all as specified and directed by Engineer-in-charge.
S/F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings, (exclusive or steel sheeting or other covering), running rails and guides and hanging; also fastening and fixing complete of grade fe 410 E-250 grade Aetc completed and as directed by Engr in charge
M & L two coats of synthetic enamel paint on MS/Steel surfaces incl of a single hanger door of any size over one coat of red oxide or zinc chrome primer compete all as specified as directed by Engineer -in -charge
Removing of concrete debris from site including loading and unloading of debris and thrown away up to 1.5 km distance from the site and as directed by Engr in charge etc complete and as directed
Repair maintenance of lifts including carry out daily check and periodical once in a month as per Appx'C' attached of semi/fully automatic electrically operated lift 500/1000 Kg with repair /maintenance of unserviceable damaged parts such as bearing bushes all type of shoes headers, hangers , car door, door lock, control cards, connector/ links, wielding of crack/ broken MS Parts, repair of unsv damaged door, safety edge or sensor mechanically safety lock , car position indicator, door seal, card, wiring, hall push button assembly including all connected accessories complete with push button ,inclusive repair of harness wiring of control panel , minor repair to cabin, cabin light, fan etc ensure safety and smooth functioning of lifts, cutting wall making good disturbed surface with masonry work to make the existing surface, cable as per requirement or or safety operation of lift, , maintenance of unserviceable /worn out parts such as warm wheel, warm shaft, bushes, thrust bearing and necessary packing including overhauling , cleaning alignment of gear box assembly after repair/replacement of worn-out parts re-assemble and fixing with existing machine with proper alignment complete maintenance of car top, binding of loose wire at control panel and rust painting at car top and door and allied parts with testing.
Comprehensive inspection, testing, and certification of the lift system as per OEM guidelines from the lift inspector, IS standards (including IS 14665), and statutory lift regulations. The scope includes full functional testing of lift operations; verification of car and landing operating panels; door operation checks; leveling accuracy; limit switch performance; testing of all safety devices; conducting rated load test using calibrated test weights; examination of motor performance, braking efficiency, overspeed governor operation, safety gear engagement, buffer test, and emergency operations including ARD (Automatic Rescue Device). Also includes thorough electrical system testing covering the control panel, wiring, earthing, interlocks, alarms, emergency lights, and power supply integrity. The job further covers issuance of the required Lift Testing Certificate along with all documentation such as test reports, checklists, calibration certificates, and endorsement by an through authorized Lift inspector. Charges include statutory approval submission (if applicable), transportation of test weights, manpower, tools, and all minor consumables required to complete the work as directed by Engr in charge.
Supply only Cut out with brass contacts NS type 10 Amps.
Supply only Relays PLA with eight conacts 4NO & 4NC
Supply only Power and control contactorsTP type MN up to 20 Amps
Supply only Limit switch operated through actuaters
Supply only Solinoid coil for control of actuated contacts for up movement and down movement.
Supply only Printed circuit board for control of regulated supply
Supply and fixing Brake shoes suitable for 500/1000 Kg lifts
Dismantling and taking down old COP panel with assembly and Supply and Fixing new COP with illuminated push Button for existing lift of G+1 Storey bldgs , including necessary wiring as reqd at site
Taking down the thruster brake assembly, cleaning the coils, housing and frame,warnising with class of insulation packing the assembly with suitabe insulating materials.replacing the breake shoes with set of high quality, non abressive, liners connecting up after assembly and testing.
Supply and fix in repair coil assembly for the thruster brake complete with the casing suitable for the class of brake of the capacity of lift.
Supply and fix in repair long body stud made out of alloy steel for the adjustment of brakes for the thruster brake assembly complete suitable for the class of brake of the capacity of lift.
Supply & fix Lift Wire Rope of 16 mm dia. Make:- Usha Martin
Dismantling & Design, supply, installation of new car cabin suitable for 500 kg goods lift at RSDM and RSDL (old ) building (G+1) tech area with platform alongwith 5mm aluminium Chequred plate, with aluminum sil & centre auto door of 900mm opening in SS Hairline finish of 18 gauge with car door track, alongwith SS false ceiling as per existing size, all as specified and directed by Engineer-in-Charge consisting of following items :- (i) Type of car cabin - goods lift . (ii) Load capacity - 500 Kgs (iii) Car door type- Centre opening/ one side , sliding type, hair line of 18 SWG.or as per existing size (iv) Door opening inside : 900mm (W) x 2000mm (H) or as per existing size (v) Car enclosure : Standard manufacturing with MS frame & SS panels, with false ceiling with 04 Nos LED light fitting on ceiling and concealed fan with fan grill. (vi) Fixing only 3D infra red sensor for safety edge of door for entire height. (vii) Fixing only COP suitable for (G+1) with luminous buttons (ix) Safety instruction board in car. (x) Do's and Don'ts board in car. (xi) Emergency telephone numbers board in car. (xii) Flooring : Aluminium Chequered plate 5mm thick complete. (xiii) Replacement of PCB card, relay with control wiring for G+1Storey Building.
Dismantling and taking out unserviceable old control panel with control wiring up to mid way Junction and supply & fix new control panel with control wiring up to mid way Junction comprising with multiple micro controlled programmed chip based link to each other in net work, thermal over load protection comprising with variouble voltage, variable frequancy drive (VVVF) Make : Yashikawa Japan /Schneider suitable up to 7.5 HP Motor based on micro controller and controlled by pulse with modulation complete with all safety devices such as over load, over current protection, Auto phase revers etc.including proper connection with proper lugs,terminal connectors screws and motor connection with galvanished sheet trucking 24 SWG including wiring of main motor with suitable size of standered copper cable etc, complete all as directed by Engineer-in-Charge.
Disconnecting and taking out old/unserviceable shaft wiring, supply and fixing of new shaft wiring in hoist way upto lower limit with PVC insulated copper conductor cable single core, 1100 Volts grade 0.75 Sqmm 24 Nos single core & 1.0 Sqmm for earth wire duly bunched with wire binding locking strip, drawing through in and including galvanished sheet metal trucking of 24 SWG up to ground floor in hoist for control to all function including in built connection for control panel, PCB, Hall push button, fire switch and lower limit switch all as specified and directed by the Engineer-in-Charge.
Disconnecting and taking out unserviceable COP assembly, Supply and fix new Panel assembly complete with illuminated push button for floor position, alarm, non stop door open, door close, cabin fan, cabin light stop, attend out key etc with direction indicator with LED display with CPI card of stainless steel face plate in and including necessary wiring for illuminating push button complete all as specified and directed by Engineer-in-Charge. for G+1 Storey buildings,Lifts.
Dismantling and taking out unserviceable old landing push button box along with illuminated call button with control wiring and supply & fix landing push button box alongwith illuminated call button with control wiring for G+1 storey building complete all as directed by Engineer-in-Charge.
Dismantling and taking out old un serviceable landing door from various floors & supply and fixing new Landing door complete with door headers comprise of 02 Nos power operated auto centre opening ( or one side opening as reqd at site ) by horizontal sliding stainless steel panel of 18 SWG flush type complete with door Headers Suitable for (500 kg goods lifts),including all necessary cutting opening in masonry work & making good the disturbed surface to match with the existing complete in building complete all as specified and directed by Engineer-in-Charge. Location :-
Dismantling and taking out old un serviceable car door from car cabin (500 kg goods lifts) supply and fixing new car door comprise of 02 Nos power operated auto centre opening ( or one side opening as reqd at site ) by horizontal sliding stainless steel panel of 18 SWG flush type complete with VVVF door drive unit (Make: Yaskawa Japan,Schneider) with card,Air cord,aluminium sill, incl of safety edge full beam infrared sensor (Lamda), aluminium safety in full length and Car door headers complete all as specified and directed by Engineer-in-Charge. :-
Disconnecting and taking out old/unserviceable travelling cable from hoist way and supply and fix new travelling cable PVC Insulated 16 core with stranded copper conductor, 1100 volts grade of size 0.75 Sqmm conforming to relevant IS including criping with lugs appropriate thimples complete all as specified and directed by Engineer-in-Charge. Make :- Polycab/Finolex
Supply and fixing for Outdoor Floor Mounted cubical Street Light panel Box , self supported, front openable, double door ,hinged type with locking arrangement & sloping top canopy ,suitable ventilation, with wire mesh, IP52 protection with Dust & Vermin proof etc made of 3.15 mm CRCA sheet duly powder coated , mounted/fixed on MS Angle iron 50*50*6 mm thick duly painted with black enamel synthetic paint over coat of red oxide zink chrome primer, duly grouted in PCC 1:3:6 Type C1 using foundation ,suitable size of MS Gland with gland plate, and aluminum lugs/ for all incoming and outgoing cables ,etc. Havells Cat Part No: IHXSS0312A or equivalents .Complete all as directed including and accommodating with the following, (a) MCB 63Amp TPN 415 Volts KA - 01 Nos (b) Contactor 65 A TP (c) Astronomical Timmer
S&F MS Single arm bracket 1.50 mtr long 40 mm dia, fixing with suitable nut bolt and washer as described in OEM manual complete all as as directed by Engr-in-charge.
Material and labour for cable joint termination box PVC body housing suitable for housing and including 100 amps rated, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tublar pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 amps MCB, SP, 240 volt for street light supply complete all as as directed by Engr-in-charge.
Dismantling of old and unservicable cross arms and M&L for cross arms, bracings, supports, clamps and back plates fabricated from strucural steel sections including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated, with & inclusive of one coat red oxide primer & one under coat and one finishing coat of synthetic enamel paint after preperation of surfaces all as soecified, as directed by engg in charge.
M&L for Periodical maintenance of Effluent Treatment Plant (ETP) 6 KLD Effluent streams handling with - Cyanide, Chrome & Acid/Alkali, once in three month by checking & Testing all connected part complete all as directed by Engr-in-charge comprising with the following:- Checking the serviceability of following tanks and repair any leakage found and cleaning of tanks Cleaning of Acid Alkali, tank 2000 ltrs Cleaning of chrome tank 2000 ltrs Cleaning of cynide tank 2000 ltrs Cleaning of Neutalite tank 6000 ltrs Cleaning of Tube settelar tank 2000 ltrs Cleaning of Sludge tank 2000 ltrs Cleaning of Sand filter by removing sand and charcoal Cleaning of Carbon filter and removing filter Cleaning of filter Press Checked serviceability of Filter Press, Charcaol Filter (ACF), Bag filter System ,Pressure Sand Filter (PSF), Resin Filter (RF) and and cleaning the same as per OEM Instruction complete all as directed by Engr-in-charge General checking of all water and pump and servicing of motor including greasing of all parts
Supply only Caustic soda
Supply only Ferrous sulphate
Supply only Lime powder
Supply only Allum powder
Supply only Bleching powder
Supply only Hydocloric acid (HCL)
Supply only sand as per sample
Supply only Charcoal as per sample
Supply / Fixing in replacement Digital PH meter size 96X96 mX115 mm, range 0.00 to 14.00 pH, 220 Volt, AC, cailibrated on 7 PH Make as per sample.
Supply / Fixing in replacement Chemical dosing pump PT 200 max flow rate 6-25 LPH, 125 PSI/8.6 bar, 50 Hz, 45 watt Make as per sample.
Supply & Fixing in replacements reaction tank for Acid /alkali made of PP ( Poly propylene ) as per existing design, size , thickness and capacity ( Approx 2000 Ltrs ) with supporting frame work at ETP plant Tech area including all connection of water supply and electric supply as reqd at site for fully function of plant incl painting in blue colour and writting tank name with white in colour of suitable size complete all as specified and as directed by Engr-in-charge incl taking down old unserviveable tank.
Supply & Fixing reaction tank for cynide made of PP ( Poly propylene ) as per existing design, size , thickness and capacity ( Approx 2000 Ltrs ) with supporting frame work at ETP plant Tech area including all connection of water supply and electric supply as reqd at site for fully function of plant incl painting in blue colour and writting tank name with white in colour of suitable size complete all as specified and as directed by Engr-in-charge incl taking down old unserviveable tank.
Supply & Fixing reaction tank for neyterlisation tank made of PP ( Poly propylene ) as per existing design, size, thickness and capacity ( Approx 6000 Ltrs ) with supporting frame work at ETP plant Tech area including all connection of water supply and electric supply as reqd at site for fully function of plant incl painting in blue colour and writting tank name with white in colour of suitable size complete all as specified and as directed by Engr-in-charge incl taking down old unserviveable tank.
Taking down existing unsv electric motor 3 phase, 415 volts, 50 HZ , capacity 0.5 to 1 KW motor of any make after disconnecting all electrical connection and shift to workshop for repair. Dismantling the motor , removing old burnt winding, cleaning the slots, checking and setting the stampings, providing a coat of insulating warnish, rewinding with super enamelled copper conductor winding wire of suitable gauge, packing the slots with insulating sleeves. drying in controlled temperature, re-assembling the motor with new set of bearings and connecting with its original place.
Taking down existing unsv electric motor 3 phase, 415 volts, 50 HZ , capacity 1.5 to 3 KW motor of any make after disconnecting all electrical connection and shift to workshop for repair. Dismantling the motor , removing old burnt winding, cleaning the slots, checking and setting the stampings, providing a coat of insulating warnish, rewinding with super enamelled copper conductor winding wire of suitable gauge, packing the slots with insulating sleeves. drying in controlled temperature, re-assembling the motor with new set of bearings and connecting with its original place.
Taking down existing unsv rusted iron base frame of suitable size of 1 HP motor with pump at ETP Plant and supply and fixing New pump moter base brame as per existing size complete all as specified and as direceted by engr-in-charge.
Supply and fixing in replacement of filter press cloth as per existing size and sample
Supply and fixing in replacement gear oil for ETP pump motor
Supply,install,testing & commissioning in replacement of End suction Horizontal centrifugal chemical process pump Model No :NSRP50TBGV1L Make:ANTICO ,Flow -4 Cum/Hr,DNS(mm)-50,DND(mm)-40,1HP motor,14N 1440 RPM (HSN:84137091),including the MS Fabricated base frame suitable for 80 frame size 1Hp/1440 RPM ,coupling for pump motor ,MS coupling guard for Pump+motor,pump+ motor mounting bolts & MS foundation bolts.(The Job includes dismantelling of old base frame and construction of new base frames along with PCC work and fabrication work complete all as specified & as directed by Engineer-In -Charge.
Material & labour for MS Fabricated base frame (Net weight 18Kg)suitable for 80 frame size of 1Hp/1440 RPM ,coupling for pump motor ,MS coupling guard for Pump+motor,pump+ motor mounting bolts & MS foundation bolts. (The Job includes dismantelling of old base frame and construction of new base frames along with PCC work and fabrication work complete all as specified & as directed by Engineer-In -Charge.
Taking down existing unsv electric motor 3 phase, 415 volts, 50 HZ , capacity 3 KW motor with shaft , supply and fixing new electric motor 3 phase, 415 volts, 50 HZ , capacity 3 KW motor with existing size of shaft with new set of bearings and connecting with its original place complete all as specified and as direceted by engr-in-charge.
Taking down existing unsv flange/head of existing electric motor 3 phase, 415 volts, 50 HZ ,and supply and fixing pump- head/flange suitable for 1 HP pump motor complete all as specified and as direceted by engr-in-charge.
Supply and fixing PVC Pipe 40 mm dia for water supply connection of various pump motor to tank complete all as specified and directed by Engineer- in-charge.
All as per item no-109 but PVC Elbow 40 mm dia
All as per item no-109 but PVC Tee 40 mm dia
All as per item no-109 but PVC Socket 40 mm dia
All as per item no-109 but PVC Union 40 mm dia
All as per item no-109 butPVC NRV 40 mm dia
All as per item no-109 but PVC Pipe 25 mm dia
All as per item no-109 but PVC Elbow 25 mm dia
All as per item no-109 but PVC Tee 25 mm dia
All as per item no-109 but PVC Socket 25 mm dia
All as per item no- 109 but PVC Union 25 mm dia
All as per item no-109 but PVC NRV 25 mm dia
All as per item no-109 but PVC Stop cock butter fly 15 mm dia
All as per item no-109 but PVC Stop cock butter fly 25 mm dia
All as per item no-109 but PVC Stop cock butter fly 40 mm dia
PVC flexible wire 2.5 sqmm 4 core
PVC Flexible pipe 20 mm dia
PVC Conduit pipr 20 mm dia
Multi function meter
Indicating lamp
MCB SP 2Amp
MCB TP 6 Amp
Contactor (MNX 09 , 3 Phase 1No+1NC as per sample
Relay as per existing size
Material & labour to collect waste water from ETP technical area 11 BRD in container,sending it to acreeditted NABL lab/MPCB lab , to carry out chemical analysis as well as phisical parameter test from approved lab for following parameter (i) BOD (ii) COD (iii)total suspended solid (iv) Ph:7-8 (v) Cynide (vi)Nickel vi) Chromium Viii) Acidity ix) Alkalinity
M&L for inspection /periodical maintenance/ brake down maintenance incl servicing of Fire alarm system any type and make of different location of 11 BRD tech area ( Fire alarms, smoke detectors, fire panel , sesor etc ) by checking & Testing to ensure proper function compete all as specified and as directed by Engr-in-charge , comprising of the following. Testing of smoke detectors and fire alarms to be functional Cleaning of fire alarm sensor and other parts to prevent dirt and dust buid-up Ckecking of sesors and wiring to be all functional of Signal Section Make Bosch-01
All as per Item No-134 above but location RSDM Building Make - Bosch-01
All as per Item No-134 above but location RSDL (New) Building Make -Honeywell -03
All as per Item No-134 above but location RSDL (Old) Building Make - Bosch-01
All as per Item No-134 above but location ASD-30 Hanger and Ejection Seat Ba Make - Hochiki and Honey well -03
All as per Item No-134 above but location Launcher Bay Building Make - Siemens-01
All as per Item No-134 above but location PZ bay Make - Honey well-01
All as per Item No-134 above but location 762 SU Make - Bosch &Honey well-02
All as per Item No-134 above but location IT Make - Bosch-01
Supply ,install,testing & commissioning Addressable photoelectric smoke detector with base suitable for different type of Make as Siemens, Bosch, Honey well or as existing make as approved by engr-in-charge complete all as specified & as directed by Engineer-In Charge
Supply ,install,testing & commissioning addressable manual call point suitable for different type of Make as Siemens, Bosch, Honey well or as existing make as approved by engr-in-charge complete all as specified & as directed by Engineer-In Charge
Supply ,install,testing & commissioning control relay for module for hooter suitable for different type of Make as Siemens, Bosch, Honey well or as existing make as approved by engr-in-charge complete all as specified & as directed by Engineer-In Charge
Supply ,install,testing & commissioning hooter cum strobe suitable for different type of Make as Siemens, Bosch, Honey well or as existing make as approved by engr-in-charge complete all as specified & as directed by Engineer-In Charge
Supply ,install,testing & commissioning isolater module suitable for different type of Make as Siemens, Bosch, Honey well or as existing make as approved by engr-in-charge complete all as specified & as directed by Engineer-In Charge
Supply and lay 2 core 1.5 sq mm armoured FRLS copper cable for interconnecting devices in PVC conduit of 20 mm dia,complete all as specified & as directed by Engineer-In Charge
M&L for GI tubing light grade with all fitting laid in trenches or fixed to wall or ceiling with clamps or fixed to floor complete all as specied and directed of size 20 mm bore, complete all as specified & as directed by Engneer-in Charge.
All as per item no- 150 above but DG Set 200 KVA Location -RSDL(N)
All as per item no- 150 above but DG Set 125 KVA Location -MAP Sub STn
All as per item no- 150 above but DG Set 125 KVA Location -HQ
All as per item no- 150 above but DG Set 82.5 KVA Location -IT
All as per item no- 150 above but DG Set 75 KVA Location -OTS Hall
All as per item no- 150 above but DG Set 75 KVA Location -Tapovan
All as per item no- 150 above but DG Set 65.5 KVA Location -LSW server
All as per item no- 150 above but DG Set 40 KVA Location -ASD-29
All as per item no- 150 above but DG Set 40 KVA Location -Pump House Raksh Nagar
All as per item no- 150 above but DG Set 40 KVA Location -MT
All as per item no- 150 above but DG Set 40 KVA Location -CIMD
All as per item no- 150 above but DG Set 40 KVA Location -KV Sub stn
All as per item no- 150 above but DG Set 40 KVA Location -Airmen Mess
All as per item no-150 above but DG Set 40 KVA Location -STP-1
All as per item no- 150 above but DG Set 30 KVA Location -CIMD 3 D
All as per item no- 150 above but DG Set 30KVA Location -SMC
Supply and Fix in Replacement of Spares for Repairing of DG Set 250/200 KVA:- Make:- Cummins/KOLE
Supply and Fix in Replacement Lub Oil filter suitable for 200 KVA , Make:- Cummins
Supply and Fix in Replacement Diesel Fuel filter suitable for 200 KVA , Make:- Cummins
Supply and Fix in Replacement Air filter (inner and outer) suitable for 200 KVA , Make:- Cummins
Supply and Fix in Replacement Hose Pipe Set suitable for 200 KVA , Make:- Cummins
Supply and Fix in Replacement Hose Clip Set for 200 KVA , Make:- Cummins
Supply and Fix in Replacement V belt Set suitable for 200 KVA , Make:- Cummins
Supply and Fix in Replacement Solenoid fuel pump. suitable for 200 KVA , Make:- Cummins
Supply and Fix in Replacement DG set auto controller 3 phase, 415 volt Ac , door mounted having all input output suitable for DG set 200 KVA make cummins complete with PCB , wiring and Display unit make - HMI211, powerica etc at RSDL new as per existing .
Repaire maint/ serviceing of Starter 200/250 kva DG
Supply and Fix in Replacement Supply and Fix in Replacement of Spares for Repairing of DG Set 125/82.5 KVA:- Make:- Cummins Lub Oil filter suitable for 125 KVA/82.5 , Make:- Cummins
Supply and Fix in Replacement Diesel Fuel filter suitable for 125 KVA/82.5 , Make:- Cummins
Supply and Fix in Replacement Air filter (inner and outer) suitable for 125 KVA/82.5 , Make:- Cummins
Supply and Fix in Replacement Hose Pipe Set suitable for 125 KVA82.5 KVA , Make:- Cummins
Supply and Fix in Replacement Hose Clip Set for 125 KVA/82.5 KVA , Make:- Cummins
Supply and Fix in Replacement Supply and Fix in Replacement of Spares for Repairing of DG Set 75 KVA:- Make:- KirloskarDiesel Fuel filter suitable for 75 KVA
Supply and Fix in Replacement Lub Oil filter suitable for 75 KVA
Supply and Fix in Replacement Air filter (inner and outer) suitable for 75 KVA.
Supply and Fix in Replacement Hose Pipe Set suitable for 75 KVA.
Supply and Fix in Replacement V belt Set for 75 KVA
Supply and Fix in Replacement Solenoid fuel pump. for 75 KVA.
Supply and Fix in Replacement Starter Solonoid for 75 KVA.
Supply and Fix in Replacement Starter Servicing for 75 KVA.
Supply and Fix in Replacement VMR Panel Mounting for 75 KVA.
Supply and Fix in Replacement Fly wheel Gear Ring for 75 KVA. And 125 KVA DG set.
Supply and Fix in Replacement Head Gasket suitable for 75 KVA.
Supply and Fix in Replacement following Spares for Repairing of DG Set of Capacity 62.5 KVA:- Make:- Cummins Diesel Fuel filter suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement Lub Oil filter suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement Air filter (inner and outer) suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement Hose Pipe Set suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement V belt Set suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement Solenoid fuel pump. suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement Starter Solonoid suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement AMF Controller suitable for 62.5 KVA.
Supply and Fix in Replacement Fly wheel Gear Ring suitable for 62.5 KVA.
Supply and Fix in Replacement Head Gasket suitable for 62.5 KVA
Supply and Fix in Replacement Tappet Cover Gasket suitable for 62.5 KVA. & 75 KVA .
Supply and Fix in Replacement of Spares for Repairing of DG Set 40 KVA:- Make:- Kirloskar Diesel Fuel filter suitable for 40 KVA.
Supply and Fix in Replacement Lub Oil filter suitable for 40 KVA.
Supply and Fix in Replacement Air filter (inner and outer) suitable for 40 KVA
Supply and Fix in Replacement Hose Pipe Set suitable for 40 KVA.
Supply and Fix in Replacement V belt Set for 40 KVA.
Supply and Fix in Replacement Solenoid fuel pump. for 40 KVA.
Supply and Fix in Replacement Starter Solonoid switch for 40 KV
Repai/maint of unserviceable Starter for 40 KVA.
Supply and Fix in Replacement Engine Safety Unit for 40 KVA.
Supply and Fix in Replacement Wiring Harness for 40 KVA.
Supply and Fix in Replacement Fly wheel Gear Ring
Supply and Fix in Replacement Head Gasket suitable for 40 KVA.
Supply and Fix in Replacement DG set auto controller 3 phase, 415 volt Ac , door mounted having all input output suitable for DG set 40 and 82.5 KVA make cummins & KOEL/ Greaves cotton complete with PCB , wiring and Display unit make - HMI211, powerica etc at RSDL new as per existing .
Supply and Fix in Replacement Supply and Fix in Replacement of Spares for Repairing of DG Set 30 KVA:- Lub Oil filter suitable for 30 KVA , Make:- Cummins
Supply and Fix in Replacement Diesel Fuel filter suitable for 30 KVA , Make:- Cummins
Supply and Fix in Replacement Air filter (inner and outer) suitable for 30 KVA , Make:- Cummins
M& L for cleaning and descaling of radiator assembly upto 40/62.5/75/82.5 KVA capacity by using suitable chemical and blower fan ,injecting water with high pressure in water tubings so as to remove all dirts in the fins, taking down the copper bottom portion of tank for welding / brazing and refitting the all disconnected components after replacing the unserviceable and damaged fins tank cap rubber bush and refix the same at the engine of DG sets complete all as per manufacturer's instructions and as directed.
Supply only coolant concentrate Make : Valvoline
Dismantling and taking out Dynamo/alternator assembly of 12 Volts/24 Volts from the DG sets replacing the spare parts such as carbon brushes, springs, spring holders, brushes, bearings or any other part required for full functioning of machine and fixing and testing complete as specified and directed by Engineer-in-Charge
Dismantling and taking out dynamo/alternators from DG set for rewinding and taking out the old coil, cleaning thoroughly and wound with new super enameled copper cord of existing size and gauge, varnishing, drying, heating as per manufacturer norms and fixed with dynamo/alternator properly testing and commissioning suitable for40 to 62.50 KVA all as specified and directed by Engineer-in-Charge
S&F in replacement of radiator hoses of any size and any capacity of DG set and fixed properly with new jublee clips, clamps, nuts and testing complete as directed by Eng-in-charge
Dismantling and taking out the FIP (PT Pump Assy) for repairing by replacing the worn out gasket, filter, suction valve, discharge valve and fixing the same after calibration and testing complete all as directed by Engr-in-charge of capacity 200 KVA / 250 KVA/ DG set. Note : Repairing & Calibration shall be carried out by authorised dealers only.
As per item No 225 above but for DG set of capacity 82.5KVA/75KVA/62.5KVA
As per item No 225 above but for DG set of capacity 40KVA
Supply and fixing in repair AVR unit for 250/200 DG Set & testing etc complete as specified and directed by Engr-in-charge Make : Kirloskar/Cummins
Supply and fixing in repair AVR unit for 125/82.5KVA/75KVA/62.5KVA DG Set and testing complete as directed by Engr-in-charge . Make : Kirloskar/Cummins
Supply and fixing in repair AVR unit for 40KVA DG Set and testing etc complete as directed by Engr-in-charge . Make : Kirloskar/Cummins
Dismantling and taking out the water body pump assembly complete from the DG set upto capacity 75 KVA at site and Supply and fixing of new water body pump complete.
Supply & fix battery terminals made of brass superior quality incl taking down old one etc complete as directed.
Dismantling and taking out the defective self starter assembly of any capacity (12V/24V) form the DG set and re-fixing the same after repair works including replacing the spare parts such as carbon brushes, springs, spring holder bushes, bearings, or any other spare part not mentioned herein but essentially required for proper functioning of the starter assembly complete all as specified and directed.
Dismantling and taking out self starter from DG set and taking out unserviceable old coil , cleaning thoroughly slot and rewinding the starter with super enameled copper conductor of existing size and gauge including varnishing drying, heating and re-fixing the same after repair incl testing all as specified and directed.
Supply & Fixing flexible pressure hose for lubricant oil and fuel for any size/capacity/model/make of DG set incl taking down old one etc complete all as specified.
Dismantling the radiator of 82.5 to 40 KVA DG set its position and soldering of copper pipes, where leakage incl rectifying leaks & cleaning radiator and PVC hose and fitting the same place and testing complete as specified
Material and labour for draining out old engine/lubrication oil from chamber of the DG sets, cleaning of chamber thoroughly and filling new engine/lubrication oil of grade 20W40 complete all as specified and directed.
S & F battery leads 95 Sqmm copper cable unth as reqd at site etc complete as specified and directed by Engr-in-charge
Material and labour for dismantling and taking out the alternator above 40 KVA but upto 82.5 KVA capacity from the DG sets from coupling and opening the stator & rotor including cleaning of dust from windings for proper ventilation, renewal of carbon brushes with brush holder and re-assembling the rotor & stator complete including applying suitable greasing & oiling of bearing & moving parts and refixing the same on its position and testing complete all as specified and directed.
Material and labour for rewinding of exciter field of the alternator of capacity 40 KVA to 82.5 KVA using same quality same gauge of copper wire,varnishing re-assembling the rotor & stator complete including applying suitable greasing & oiling of bearing & moving parts and refixing the same on its position and testing complete all as specified and directed.
Material and labour for rewinding of exciter rotor of the alternator of capacity 40 KVA to 82.5 KVA using same quality same gauge of copper wire,varnishing re-assembling the rotor & stator complete including applying suitable greasing & oiling of bearing & moving parts and refixing the same on its position and testing complete all as specified and directed.
Supply & Fix in replacement AVR suitable for DG set from 40KVA to 82.5KVA
Supply & Fix in replacement Diode set (+ve &-VE)suitable for DG set from 40KVA to 82.5KVA
Supply & install Vacuum cleaner of capacity Vaccum-210 Mbar ,Container Capacity – 12L ,Voltage – 230V/50 Hz ,Motor – 1.4 Kw ,Weight – 5.4 Kg,Model No - SE 33 of Make STIHL or Equivalent in Bosch/Stanly complete all as specified and directed.
Supply and Fix in repair Genset Harness of any capacity of DG set
Supply and Fix in repair Relay Assembly of any capacity of DG set
Supply and Fix in repair Interface Harness of any capacity of DG set
Supply and Fix in repair Engine Harness of any capacity of DG set
Supplying, fixing lead acid battery, 12 volts, 150/180 AH with lead acid suitable for DG set including initial charging (Make- EXIDE / AMRON ) including connction and testing incl taking down old one complete as specified and directed .
Supplying, fixing lead acid battery, 12 volts, 100/110 AH with lead acid suitable for DG set including initial charging (Make- EXIDE / AMRON ) including connction and testing incl taking down old one complete as specified and directed .
Supplying, fixing maintance free rechargeable lithium ion battery designed for continuous duty in fire alarm and life safty system, , 12 volts, 12 AH with including initial charging (Make- EXIDE / AMRON ) including connction and testing incl taking down old one complete as specified and directed .
Supply only distilled water for batteries.
Supplying & fixing Exhaust Gasket as per existing make/model/type of capacity of DG set 40 KVA DG Set incl taking down old one etc complete as specified and directed Note : 132 to 171 - (i) DG set should be repair within 12 hours after receiving the massage from department. If the contractor fail the repair of DG set within perioud, the penality should be paid 250/per hours to department. (ii) Any minor material/spare reqd for proper functioning wheather not cover in CA Contractor will provide the same for functioning of D G set.
Material and labour for servicing/repair of AMF Panel of DG Set up to 250 KVA capacity for smooth functioning of the same with renewal / repair/replacement all connection to DG sets and LT panel and reassemble the AMF panel after repair / replacement of old unserv parts including fixing only the serviceable parts/ new parts of AMF panel, wiring control timer, engine starting relay, contact kit repalacement, AMF relay, HRC fuse of existing rating etc complete for DG sets installed at various pockets under AGE E/M Ojhar all as specified and as directed wiring & VMR & controller ,DG set & AMF panel controller caliberation to synchronised all safety parameter of from 40 to 250 KVA DG sets,recrimping of cable,rewiring with new set of wiring of suitable size, recommissioning and test run from authorised rep of company of company,testing for following parameter i) High water temperature ii)Low oil pressure trip iii)High voltage trip iv) Under Voltage trip iii) Under Frequency trip,submitting its service report complete all as specified & as directed by Engineer in charge.(Note:- The rate quoted by the contractor shall be deemed to included the cost of spares/relays or any other part not mentioned herein but essential required to make the AMF panel completely functional and no extra payment shall be made for the same.)
Supply & fix in replacement Voltage monitoring relay complete as specified and directed .
Supply & fix in replacement AMF controller complete as specified and directed .
Supply & fix in replacement three phase contactor with new contactor of 100 amps capacityof Make : Siemens/L&T/Legrand complete as specified and directed .
Supply and fixing Batter charger 12 V,DC, 2 Amp complete suitable for 40 to 75 KVA Dg set complete all as specified and directed .
Supply and fixing Foam sound obsorver as per existing make, suitable to fit in DG set door inner side up to 82.5 KVA DG Set incl taking down old one etc complete as specified and directed .
Supply and fixing in replacement of Door Hinges suitable for DG set canopy complete as specified and directed .
Supply and fixing in replacement of Door lock as per suitable size and model of existing make and model complete as specified and directed .
Supply and fixing push button as per existing make, model and capacity etc suitable for 40/62.5 KVA DG Set incl taking down old one etc complete as specified and directed .
Supply & Fixing in repairs "ON LOAD" type Change over switch 200 Amps TPN in sheet metal box with front handle operated, , suitable for three phase, 415V, 50 Hz AC supply of following ratings :- Make - L&T/Schneider/C&S/indoasian/HPL
All as per Item No 265 above but 100 Amps
All as per Item No 265 above but 63 Amps
S&F MCCB TP of capacity 100/63 Amps, 50 Hz, 415V with rupturing capacity of 16 KA with fixed thermal magnetic settings including spreader terminals complete incl taking down old one etc complete all as specified and directed.
Current Transformer with CT ratio 100/5 as per sample.
Contactor FP, 3 Phase 63 A FP , AC as per sample
M&L for maintenance of DG set Canopy door by taking down door from DG set denting the damaged portion of MS door and weilding the same if reqd for any desire shape and cleaning the old painted srface of Door and painting with synthetic enamel paint as existing colour to achive good finish.
M&L for painting to the entire body of DG sets ,Base frame,exhaust muffler enclosure by scrapping out the old paints , denting, spray painting to the DG set with minimum two coats of synthetic enamel paint to achieve bright finish over a coat of primer and writing of MES/SM No of DG set all as directed,removing algae from the plith of DG set and painting it with cement based paint for the capacity of DG sets up to 250 KVA .
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.30 MB
GENPAGE8375.pdf
Tender Documents • 0.55 MB
CREDIT8375.pdf
Tender Documents • 0.19 MB
PSEM8375.pdf
Tender Documents • 0.79 MB
BOQ_839314.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid