Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L1 | Accepted-AOC Accepted being lowest bidde4r | |
| 2 | L2₹41.4 L+₹1.4 L (3.53%)Rejected-Finance 3RD FLOOR VVIP RESIDENCY MAHINDER VIHAR CHAKRATA RD NEAR RAMADA HOTEL DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Rejected being not lowest bidder | |
| 3 | L3₹49.2 L+₹9.3 L (23.2%)Rejected-Finance GALA NO B 128 129 130 SATYAM INDUSTRIAL ESTATE OFF KARVE ROAD OPP SNDT COLLEGE ERANNDWANE PUNE 411038 PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | L3 | Rejected-Finance Rejected being not lowest bidder |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
8 Sept 2022, 6:00 pmClosed
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
REPAIRS AND REPLACEMENT OF FILTERS UNSV CONTROL VALVES SERVICING OF AHUS DESCALING OF CONDENSER COOLING TOWER DUCTS AND CONNECTED ACCESSORIES FOR WATER COOLED SCREW CHILLED AIR CONDITIONING PLANT 3 X 200 TON CAPACITY AT PH-I BLDG MH KIRKEE UNDER
2022_MES_543774_1
CWE/KKE/TOKEN-17 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
KIRKEE
As per tender documents
5 documents required · 5 mandatory
₹1,000
Yes
GE MH AND RH KIRKEE
₹1 L
Yes
23 Sept 2022
6 Aug 2022
10 Sept 2022
6 Aug 2022
8 Sept 2022
26 Aug 2022
8 Aug 2022 - 12 Aug 2022
Amount
Carrying out annual maintenance of 200 TR water chiller plant by OMC (original manufacturing company i.e Kirlosker) including following routine work if necessary. Completed all as specified and directed by Engr-in-Charge :- (a) Quarterly visit by OMC engineer to carryout preventive maintenance checks and number of break down calls (b) Carry out preventive maintenance for betterment of the chiller (c) Carry out oil inspection as and when required including testing of the same for the serviceability for better life of lubrication parts and semi hermatic motor.
(d) Checking the set parameters in the controller taking and safety fault trips taking control test contacts cleaning (e) Checking the actual performance /operationing parameters of the chiller with the help of log reading recorded during the previous month and actual parameter of the chiller
(f) Taking up repair /replacement of parts /spares/driers/oil as required by OMC Engineer. (g) Carrying out condenser descaling by OMC Engineer if required (h) Servicing, including detail check up and maintenance/ calibration of relays of microprocessor based Control panel of all three 200 TR AC Plant and keep the same functional all as specified and directed.
Note : (i) Refrigent leak test is to be carry out under supervision of OMC engineer or by OMC Engineer. (ii) The tool replaced for any special purpose and general purpose tools will be supplied by contractor and rate will deemed to be included in unit rate. (iii) The responsibility of Payment in advance to OMC will be lying on contractor. (vi) This contract will cover lifting /shifting of any type material ,up/down the building or shipment cost or freight of any material from site to OMC or any sub venders works.All other charges and transit insurance will be included in this contract. (v) All spare /store required during repair and maintenance which shall be genuine Parts of OMC and measured and paid under relevant items and supply only
Supply and replacing the following defective / worn out spares / controls for the chiller Plant. Complete all as specified and directed by Engr -in-Charge. Make Kirloskar / voltas / Blue star
Sensor Pressure TI 500, 20 FT for MCS Controller for KW4 220.17 OS Make : Kirloskar/Blue star / Dun-Ham-Bush
Sensor Temperature TI100 for MCS Controller for KW4 220.17OS Make : Kirloskar/Blue star / Dun-Ham-Bush
Valve Solenoid Modle- EVR 20, Connection Size -1-1-/8 INCH X 1-1/8 INCH ODF, supply 24V AC For KW4 220.17 OS Make : Kirloskar/Blue star / Dun-Ham-Bush
Gasket and O-Ring Kit,Oil Filter For KW4 220.17 OS Make : Kirloskar/Blue star / Dun-Ham-Bush
Valve Solenoid 7/8IN. ODS 110V/10W for KW4 220.17 OS Make : Kirloskar/Blue star / Dun-Ham-Bush
Valve Non return 36 Bar Flange type for KW4 220.17 on discharge line Make : Kirloskar/Blue star / Dun-Ham-Bush
Valve Electronic Expansion, Model-EX8-I21, Connection-1-5/8 ODF For KW4 220.17 OS Make : Kirloskar/Blue star / Dun-Ham-Bush
Suction Strainer F-4 For KW4 220.17 OS Make : Kirloskar/Blue star / Dun-Ham-Bush
Valve Safety, Set PR-21 Bar,size-1" NPT(M)X1"NPT(F), CE Certified as per PPS-NM40011 For KW4 220.17 OS Make : Kirloskar/Blue star / Dun-Ham-Bush
Valve Safety, Set PR-13 Bar,size-1/2" NPT(M)X3/4"NPT(F), CE Certified as per PPS-NM40011 For KW4 220.17 OS Make : Kirloskar/Blue star / Dun-Ham-Bush
Glass fuse for master Board power supply Make : Kirloskar/Blue star / Dun-Ham-Bush
Gasket for water nozzle-round flange (Conderser) Make : Kirloskar/Blue star / Dun-Ham-Bush
Glass for water nozzle (Evaporator) Make : Kirloskar/Blue star / Dun-Ham-Bush
Pressure relief valve Make : Kirloskar/Blue star / Dun-Ham-Bush
Current transformer 250/0.2A with AC to DC Converter card and mounting bracket for KW4. Make : Kirloskar/Blue star / Dun-Ham-Bush
Current sensor Make : Kirloskar/Blue star / Dun-Ham-Bush
Retrofit of Electrical & Electronics Control wiring Make : Kirloskar/Blue star / Dun-Ham-Bush
Replacement of PLC Controller and SMPS Make : Kirloskar/Blue star / Dun-Ham-Bush
Expansion Board and EVD board Make : Kirloskar/Blue star / Dun-Ham-Bush
PGD O LED Display, Feed Batch Make : Kirloskar/Blue star / Dun-Ham-Bush
T Lan Card and control fuse and accessories Make : Kirloskar/Blue star / Dun-Ham-Bush
M&L for descaling of complete condenser units for central/ package type AC plant Model No : T7FAA48 - 02 MK-1of capacity 200TR by means of adding descaling chemical solution or equivalent in the cooling tower sump of required quantity and circulating the liquid to remove the scales inside the pipes and removing side covers of condenser, cleaning the water tubes by scrubbing with nylon brushes and flusing with fresh water, re fixing the covers, Inlet and out let pipes including replacement of neoprene rubber gasket etc. Completed all as specified and directed by Engr-in-Charge
Repairing /servicing and overhauling the centrifugal pump by dismantling the pump coupled with induction motor, opening the pump, inspecting for defects and replacing the worn out parts like gland bush, bearings, gland bolts and nuts,gland packing, gasket, water seal etc including repairs to pump shaft by remetalling, grinding, polishing and reassembling the same and replacing the rusted nuts, bolts, washers etc and coupling with motor testing complete for the following capacity of pumps Completed all as specified and directed by Engr-in-Charge
Chiller Pump 60 HP
Condensor pump 25 HP
M & L for taking out the centrifugal pump motor and transporting to work shop, split opeing the motor removing the u/s burnt winding wire, cleaning the slots, re winding with super enameled copper conductor wire of suitable size including insulating materials, varnishing and drying and reassembling and transporting back to site , coupling with pump testing and commissioning all as directed for the following capacities of motors : -
Chiller Motor 60 HP
Condensor Motor 25 HP
M & L for taking out the motor and transporting to work shop , split opeing the motor removing the u/s burnt winding wire, cleaning the slots, re winding with super enameled copper conductor wire of suitable size including insulating materials, varnishing and drying and reassembling and transporting back to site, refixing the motor, testing and commissioning all as directed for the following capacities of motors : -
Blower Motor of Cap 7.5 HP Make : Kirloskar/ Bharat Bijali
Blower Motor of Cap 5 HP Make : Kirloskar/ Bharat Bijali
Blower Motor of Cap 3 HP Make : Kirloskar/ Bharat Bijali
Dismantling the covers of cooling tower and the cooling fan blades from the position, electrical connections and taking down the cooling tower motor, split opening the motor, removing the burnt out winding, cleaning the slots re winding with super enameled copper conductor wire of suitable size including insulating materials, varnishing and drying and reassembling and transporting back to site and testing on commissioning of AC Plant 200TR Capacity complete all as specified and directed by Engr-in-Charge .
Descaling of cooling tower by dismantling the cooling tower fins removing the scales in the fins, sump by scrubbing with wire / nylon brush and refixing the fins in position including replacing the float valve for supply water line, painting the steel/wooden surfaces with two coats of enamel paint over a coat of zinc oxide primer and testing the cooling tower of AC Plant 200TR capacity complete all as specified and directed by Engr-in-Charge .
M & L for for painting of following pump sets with two coats of approved synthetic enamel paint all as directed . Make : Asian Paints/ Burger / Nerolac
Condenser Pump
Chilled water Pump:
Supply and replace the worn out 'V' belts of blower motor. (Make : Eco drive / fenner / reenolds rubber)
SPA1600 mm
SPA1400 mm
SPA1200 mm
SPB 1600 mm
SPA 1250 mm
SPB 2000 mm
SPA 2300 mm
SPA 1030 mm
SPA 1050 mm
Supply only Gas R-407C in cylinder for charging / topping up whenever required including leak testing all ass specified and as directed.
S&F in replacement of double fitted polymer fabric HDPE fresh air filter(Filter class-G3 as per EN 779) washable/cleanable type having efficiency 95% to 99% down to particle size of 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, of make Thermadyne/ Pall supralon filter / naveen filter all as specified by of following sizes :-
S&F in replacement of double fitted polymer fabric HDPE fresh air filter(GL-type) washable/cleanable type having efficiency 95% to 99% down to particle size of 5 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, including taking down of make Thermadyne/ Pall supralon filter / naveen filter all as specified by of following sizes :-
500mmx400mmx300mm bag type filter 5 micron
S&F in replacement of filter "HEPA"(EN-1882) with fibre glass paper filtering media capacited 1000 CFM efficiency 99.97% down to particle size of 0.3 to 0.5 micron aluminium frames box type of size 500x400x300mm including taking down of make Thermadyne/ Pall supralon filter / naveen filter complete all as specified and directed by Engr-in-Charge .
S&F in replacement butter fly valve of dia 100 mm suitable for condensing /chiller water line with ISI marked including jointing with proper gasket ,nut,bolts washer complete all as specified and directed by Engr-in-Charge. Make CRI, Kirloskar, L & T
S&F in replacement butter fly valve of dia 125mm suitable for condensing /chiller water line with ISI marked including jointing with proper gasket ,nut,bolts washer complete all as specified and directed by Engr-in-Charge. Make CRI, Kirloskar, L & T
S&F in replacement butter fly valve of dia 150 mm suitable for condensing /chiller water line with ISI marked including jointing with proper gasket ,nut,bolts washer complete all as specified and directed by Engr-in-Charge. Make CRI, Kirloskar, L & T
S&F in replacement NRV of dia 150 mm suitable for condensing /chiller water line with ISI marked including jointing with proper gasket ,nut,bolts washerall as specified. Make CRI, Kirloskar, L & T
S&F in replacement of water pressure gauge 4" dial type with cock 0-7 Kg/Sqmtr complete all as specified and directed by Engr-in-Charge. Make Emerald/ Wika / Rexroth
S&F in replacement of refrgerant/ Water Temp. gauge 4" dial type cock 0C to 50 C all as specified and as directed. Make Emerald/ Wika / Rexroth
S&F in repair 3 KW Strip Heater suitable for existing AHU incuding taking down complete all as specified and directed by Engr-in-Charge. Make : Omega / Platinum / finned
S&F in repair 2 KW Strip Heater suitable for existing AHU incuding taking down complete all as specified and directed by Engr-in-Charge. Make : Omega / Platinum / finned
S&F in replacement of following ball bearing suitable for cooling tower motor ,chillar motor,Blower motor,condenser motor etc removing of existing unserviceable bearing of any type or make complete all as specified and directed by Engr-in-Charge. . Make : SKF/TATA/FAG/ Nachi
Number - 6204zz
Number - 6205zz
Number - 6206zz
Number - 6207zz
Number - 6208zz
Number - 6304zz
Number - 6308zz
Number - 6309zz
Number - 6311zz
Number - 6313zz
S&F in replacement of following ball bearing model - P212 with housing suitable for AHU Blower etc removing of existing unserviceable bearing of any type or make complete all as specified and directed by Engr-in-Charge.
Supply Erecrtion testing and commissioning in repair O closed cell elastomeric nitrile rubber with aluminum foil laminated on oneside, having thermal Temperaturte, of 20 c as per EN 12667, moisture diffusion resistance factor or u Value of minium 7000 for base insulation material without the foil as per EN 12086, fire performance such that it passes Class 1 as per BS476 Part 7 for surface spread of flame and also fire performance of V0, HB as per UL 94, 1996, density without the foil between 40 to 55 KG/ Cum. the insulation material shall be FM ( factory Mutual) USA approved and dust & fiber free. the Aluminium foil shall be 60 microns thick and its weight shall be 193 gms as per EN ISO 2286-2, tensile strength 90 N/ 15 mm as per EN ISO 527-3 with elongation>10% as per EN ISO 527-3. All complete as specified in particular specification 19 mm thick thermal insulation as directed.
S&F in replacement MCCB of following capacities complete all as specified and directed by Engr-in-Charge. Make : L & T, Seimense, Legrand
400A,TP.415V,50 Hz, 36 KA adjustable type
250A,TP.415V,50 Hz 36 KA adjustable type
160A,TP.415V,50 Hz 36 KA adjustable type
125A,TP.415V,50 Hz, 16KA adjustable type
25 to 100A,TP,415V,50Hz,16KA
S&F 415 Volt 10 kA 'C' curve MCB of TP upto 100 Amps and current carrying capacity in the DB \ Panel all as specified and as directed. of Make : L & T, Seimense, Legrand
S&F in replacement of contactor of following capacities suitable for existing of panel and sample all as directed and as specified. of Make : L & T, Seimense, Legrand
70A, TP with 2 NO + 2 NC
3TF 52 with 2 NO + 2 NC
3TF 54 with 2 NO + 2 NC
S&F in replacement of over load relay following capacities suitable as per the existing sample and all as directed. Make : L & T, Seimense, Legrand
MN5 of rating 20-33A
Supply only Lub oil for Frame 4 compressor Part No . 55.400.81.303 for topping up whenever required complete all as specified and directed by Engr-in-Charge
Supply and replace the temperature and humidity sensor coupled with actuators complete all as specified and directed by Engr-in-Charge
Supply and replace three way mixing /modulating valve (Actuator) of diameter 125 mm proportional linear type, motorised mixing valve BS 4540 PN-10 -PN 40 having manual over ride facility with proportional thermastat/Humodity sensor and interconnecction wiring with 1.5 sq mm copper conductor multi core cablecomplete all as specified and directed by Engr-in-Charge Make : Honeywell / Rapid / Energy
All as per item no 31 above but of dia 80 mm Make : Honeywell / Rapid / Energy
All as per item no 31 above but of size 50/65 mm dia complete all as specified and directed by Engr-in-Charge Make : Honeywell / Rapid / Energy
Supply and replace unservisable cooling pad in AHU's with necessary supports etc of following size as per OEM complete all as specified and directed by Engr-in-Charge
Supply and replace unservisable blower motor base plate sutiable for 5 HP and 3 HP as per site requrment all as directed
Repair and replacement of old unserveacble AHU doors of any size door double skin pannel with pressure injected CFC & HCFC free PUF having 'K' value of 0.02 W/C/m & dinsity of 40 kg/ms pre coated, pre plasticized , galvanized outer and inner skin 0.06mm thick, air tight casing using gasket and self adhesiv,PVC Nylon hinges, handels view port and marine lamp ,limit switch etc complete all as specified and directed by Engr-in-Charge Make : Kirloskar / Blue star / Voltas
Supply and Replacement AHU blower DIDW fan blower having out velocity not exceeding S.P.(mm/wg) 50-60 m/s energy effincent fan with double inlet , double with forward or backward curved impeller for high static pressure mounted on aluminum extended side rail base frame, existing AHU of following complete all as specified and directed by Engr-in-Charge
Model : BDB-250-CM D20
Model: KAT"9/9" S D20
M&L for disconnecting and removing oid unserviceable AHU dranage line of MS pipe, S & F of new dranage line of 50 mm dia UPVC Pipe includind all fittings and necessary clamping complete all as specified and directed by Engr-in-Charge
Supply & replace unserveacble syphon with cock 3/8"complete all as specified and directed by Engr-in-Charge Make : Sant / H Guru / Poineer
Supply & replace unserveacble HRC fuse 315 Amps complete all as specified and directed by Engr-in-Charge. Make : L & T/ Seimense / Havells / Legrand
Supply & replace unserveacble water flow switch complete all as specified and directed by Engr-in-Charge . Make : Pascal / Honeywell / Adcon / Rapid cool
Supply & replace unserveacble flot valve 25 mm complete all as specified and directed by Engr-in-Charge . Make : Parag / Jaquar / Coronet
Supply & replace unserveacble dehumidifier pump 0.75 hp complete all as specified and directed by Engr-in-Charge . Make : Crompton / Kirloskar / KSB / CRI Pumps
Supply & replace unserveacble dehumidifier pump 0.5 hp complete all as specified and directed by Engr-in-Charge . Make : Crompton / Kirloskar / KSB / CRI Pumps
Repair to Microprocessor based control panel display unit for 200 TR AC chiller unit. Make : Kirloskar / Dun-Ham-Bush / Blue star
M&L for descaling of Cooling coil of AHU's of any capacity by means of adding descaling chemical solution or equivalent of required quantity and circulating the liquid to remove the scales inside the pipes and cleaning the water tubes by scrubbing with nylon brushes and flusing with fresh water, re fixing the covers, Inlet and out let pipes including replacement of neoprene rubber gasket if required etc. complete all as specified and directed by Engr-in-Charge
M & L for brazing the leaking cooling coil of any capacity with suitable material and testing complete all as specified and directed by Engr-in-Charge
S&F control transformer with incoming voltage 380/400/420/440 VAC with outgoing 12/24/36/48/110 VAC with Capacity 300 to 600 VA all as per existing plant design and parameter complete all as specified and directed by Engr-in-Charge
Painting of 200 TR capacity existing cooling tower with existing color all as per directed and specified
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .