Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAdmitted-Finance | ₹20.2 L | L1 | Admitted-Finance |
| 2 | L2₹21.0 L+₹77,452 (3.84%)Admitted-Finance | ₹21.0 L+₹77,452 (3.84%) | L2 | Admitted-Finance |
| 3 | L3₹22.4 L+₹2.2 L (10.7%)Admitted-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | ₹22.4 L+₹2.2 L (10.7%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | - | - | Rejected-Technical SLOW PROGRESS |
| Sl No | Description | Qty | Unit | Paragon Electrotechnics L3 | M/S J J ENTERPRISES L2 | JAYESH ASSOCIATE AND DEVELOPERS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down DB/main switch of any size and making good disturbed surface of wall/floor complete all as specified and directed. | 14 | EACH | 50 ₹700 | 11 ₹154 Lowest | 50 ₹700 |
| 2.00 | Taking down carefully sub-main wiring of any description and making good to ther disturbed surfaces to match the existing complete all as specified and directed. | 293 | RUNNING METRE | 20 ₹5,860 | 11 ₹3,223 | 5 ₹1,465 Lowest |
| 3.00 | Material and labour for sub main wiring (concealed/surface as required) complete with four single core 10 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 32 mm dia rigid non-metallic PVC conduit medium grade and conduit accessories including 10 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.
Note: 5 run of 10 sqmm & one run of PVC conduit shall be measured as single unit | 20 | RUNNING METRE | 1,800 ₹36,000 | 1,310 ₹26,200 | 1,150 ₹23,000 Lowest |
| 4.00 | Material and labour for sub main wiring (concealed/surface as required) complete with four single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit medium grade and conduit accessories including 6 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.
Note: 5 run of 6 sqmm&one run of PVC conduit shall be measured as single unit | 30 | RUNNING METRE | 790 ₹23,700 Lowest | 1,010 ₹30,300 | 800 ₹24,000 |
| 5.00 | Material and labour for sub main wiring (concealed/surface as required) complete with two single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit medium grade and conduit accessories including 6 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.
Note: 3 run of 6 sqmm&one run of PVC conduit shall be measured as single unit | 45 | RUNNING METRE | 475 ₹21,375 Lowest | 790 ₹35,550 | 500 ₹22,500 |
| 6.00 | Material and labour for sub main wiring (concealed/surface as required) complete with two single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit medium grade and conduit accessories including 4 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note: 3 run of 4 sqmm&one run of PVC conduit shall be measured as single unit | 180 | RUNNING METRE | 345 ₹62,100 Lowest | 520 ₹93,600 | 400 ₹72,000 |
| 7.00 | All as per serial item No 6 above but 20 mm dia rigid non-metallic PVC conduit medium grade with two runs of 2.5 Sqmm and earth continiuty conductor of size 2.5 Sqmm all as specefied and directed. Note : 3 run of 2.5 sqmm&one run of PVC conduit shall be measured as single unit | 18 | RUNNING METRE | 265 ₹4,770 Lowest | 370 ₹6,660 | 280 ₹5,040 |
| 8.00 | Taking down carefully any type point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed. | 481 | POINT | 20 ₹9,620 | 10 ₹4,810 Lowest | 10 ₹4,810 Lowest |
| 9.00 | Material and labour for point wiring (concealed) on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit medium grade accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls by cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes ,,inner and outer cover of suitable make and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed.
(a) One light point controlled by one switch. | 120 | POINT | 700 ₹84,000 | 595 ₹71,400 Lowest | 600 ₹72,000 |
| 9.01 | (b) One fan point controlled by one switch | 30 | POINT | 700 ₹21,000 | 605 ₹18,150 Lowest | 750 ₹22,500 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
11 Aug 2026, 6:00 pmClosed
SHRI DARSHAN KUMAR, EE
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR MAINTENANCE AND REWIRING OF INTERNAL ELECTRIFICATION AT VAYUSENA NAGAR, NAGPUR
2026_MES_778535_1
8842/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF NAGPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹50,000
3 Sept 2026
14 Jul 2026
13 Aug 2026
14 Jul 2026
11 Aug 2026
28 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down DB/main switch of any size and making good disturbed surface of wall/floor complete all as specified and directed. | 14 | EACH | - | - |
| 2Taking down carefully sub-main wiring of any description and making good to ther disturbed surfaces to match the existing complete all as specified and directed. | |||||
| 3 | Material and labour for sub main wiring (concealed/surface as required) complete with four single core 10 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 32 mm dia rigid non-metallic PVC conduit medium grade and conduit accessories including 10 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.
Note: 5 run of 10 sqmm & one run of PVC conduit shall be measured as single unit | 20 | RUNNING METRE | - | - |
| 4 | Material and labour for sub main wiring (concealed/surface as required) complete with four single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit medium grade and conduit accessories including 6 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.
Note: 5 run of 6 sqmm&one run of PVC conduit shall be measured as single unit | 30 | RUNNING METRE | - | - |
| 5 | Material and labour for sub main wiring (concealed/surface as required) complete with two single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit medium grade and conduit accessories including 6 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.
Note: 3 run of 6 sqmm&one run of PVC conduit shall be measured as single unit | 45 | RUNNING METRE | - | - |
| 6 | Material and labour for sub main wiring (concealed/surface as required) complete with two single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit medium grade and conduit accessories including 4 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note: 3 run of 4 sqmm&one run of PVC conduit shall be measured as single unit | 180 | RUNNING METRE | - | - |
| 7 | All as per serial item No 6 above but 20 mm dia rigid non-metallic PVC conduit medium grade with two runs of 2.5 Sqmm and earth continiuty conductor of size 2.5 Sqmm all as specefied and directed. Note : 3 run of 2.5 sqmm&one run of PVC conduit shall be measured as single unit | 18 | RUNNING METRE | - | - |
| 8 | Taking down carefully any type point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed. | 481 | POINT | - | - |
| 9 | Material and labour for point wiring (concealed) on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit medium grade accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls by cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes ,,inner and outer cover of suitable make and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed.
(a) One light point controlled by one switch. | 120 | POINT | - | - |
| 9.01 | (b) One fan point controlled by one switch | 30 | POINT | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_871969.xls
BOQ • 0.38 MB
TENDERDOC8842.pdf
Tender Documents • 0.50 MB
SOC8842.pdf
Tender Documents • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .