| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.3 LAccepted-AOC GURDASPUR ROAD OPP WAREHOUSE PATHANKOT 145 001 PB | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Quoted lowest and reasonable | |
| 2 | L2₹81.5 L+₹15,200 (0.19%)Rejected-Finance POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Quoted high rate | |
| 3 | L3₹86.9 L+₹5.6 L (6.83%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L3 | Rejected-Finance Quoted high rate | |
| 4 | L4₹88.0 L+₹6.7 L (8.23%)Rejected-Finance | L4 | Rejected-Finance Quoted high rate | |
| 5 | L5₹96.4 L+₹15.1 L (18.6%)Rejected-Finance 79 MAHATMA GANDHI MARKET SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L5 | Rejected-Finance Quoted high rate |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
21 Mar 2025, 6:00 pmClosed
Col Alex Antony CWE Sri Vijaya Puram
Commander Works Engineer, Military Engineer Services, Minniebay, Junglighat PO, Sri Vijaya Puram - 744 103
PROVN OF LT UG CABLE FOR POWER SUPPLY FROM CG POWER HOUSE TO TRV AND OTHER SANCTIONED WORKS UNDER GE HADDO SRI VIJAYA PURAM
2025_MES_697685_1
81165 PROVN OF LT UG CABLE UNDER GE HADDO SRI VIJAYA PURAM
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Sri Vijaya Puram
As per NIT
8 documents required · 8 mandatory
₹1,000
GE Haddo
₹1.9 L
Yes
8 Jul 2025
14 Feb 2025
25 Mar 2025
14 Feb 2025
21 Mar 2025
7 Mar 2025
Amount
Supply, laying, testing and commissioning of LT XLPE insulated, sheathed, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of size 3.5 core x 400 sq.mm. (laid in trenches, ducts, pole, wall etc.) complete all as specified and as as directed by engineer in charge. Note: Rate of under ground cable excludes earth Work, sand cushioning, brick or PCC covering, light Grade GI tubing where necessary,testing etc. all as specified.
Supply and laying in trenches or in cable ducts, HDPE DWC pipe of size 120mm (OD) x103.5mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT cable protection complete all as specified and as as directed by engineer in charge.
Supply and laying in trenches or in cable ducts, HDPE DWC pipe of size 40mm (OD) x 32mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT cable protection complete all as specified and as as directed by engineer in charge.
Supply and laying in trenches or in cable ducts, HDPE DWC pipe of size 50mm (OD) x 38mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT cable protection complete all as specified and as as directed by engineer in charge.
S&F PCC cable route indicators with suitable reinforcement of size 50 X 20 X 10 cm with letter inscribed on both sides as "MES LT CABLE" of specified font size not less than 60 mm as directed and mounted on PCC 40x 30x30 cm complete using PCC 1:2:4 B1 using 20mm graded stone aggregate and including painting using cement based paint to the satisfaction of Engr in charge. Note :- Each cable route indicator will be grouted at 50 RM distance.
M&L for bituminous road cutting to a width of 60cm and depth 90cm for laying of LT cable and making good with PCC (1:3:6) type B1(using 20mm grade stone aggregate) complete all as specified and directed.
Supply, install, testing and commissioning of factory made outdoor type sheet metal enclosure LT cable jointing box of minimum dimensions 90cm length x 75cm width x 70cm height size, CPRI approved of 3 way suitable for LT 1.1KV grade 3 phase 3 wire system with 09 Nos epoxy insulators with bus bar sizes for phase 40mmx20mm aluminium flat (03Nos) and neutral 40mmx10mm aluminium flat and bus bar support of epoxy type and made out of 3.15mm powder coated CRCA sheet having gasketed front hinged split doors with bottom detachable gland plate for upto 3 cable entry and exit of size 500 sqmm with suitable size of cadmium plated and nuts, bolts and wshers and incl weatherproof, bottom hole, outdoor triple key weather proof pad lockings. The panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The panel shall be of powder coated colour red complete all as specified and directed.
M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead strip of size 32X6 mm by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through 40 mm dia GI pipe for protection of GI pipe including 20mm dia GI pipe for watering GI funnel , PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing all as directed by Engr-In-Charge.
M&L earth continuity conductor or main earthing lead of size 32x6mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to ples or any other indicated situation for loop earthing etc complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtrs wide and not exv 1.5 M deep in soft/loose soil and getting out complete all as specified and directed.
Returning, filling in incl spreading, levelling and well ramming in layers not exc 25 cm in soft / loose soil complete all as specified and directed.
Removing excavated soil to a distance not exc 50M and depositing where directed at level not exc 1.5 m above starting point complete all as specified and directed
Supply and fix GI pipe from the road crossings/ obstructions and supply & laying GI Pipe 100mm dia medium grade complete all as specified and as as directed by engineer in charge.
M&L for Precast cement concrete (PCC) type C2 1:3:6 (using 40mm graded aggregate stone) for making foundation of Pole/stay assembly complete all as specified and directed.
M&L for Precast cement concrete (PCC) type B1 1:2:4 (using 20mm graded aggregate stone) for making copings including use and waste of form work complete etc. complete all as specified and directed.
Taking down the old light fittings, dismantling old unserviceable RCC poles from ground level and removing from the site complete all as specified and directed.
Suppply an fixing Octagonal hot deep galvanised poles of 7 Mtr height with stiffener, including single bracket/arm of 1mtr length of required size, with base plate of size 220mm x 220mm Square type, thickness of base plate 12 mm, sheet thickness of pole 3 mm, dia of bottom of pole 130 mm and top dia of pole 70 mm with openable door and electric system with 01 No MCB SP 6 Amp and 32 Amps connector 3-phase and 3 core 1.5 Sqmm PVC insulated cable run for connecting street light fitting from MCB including fixing by nuts and botls of size not less than 20mm dia of length min 600mm, qty 4 nos complete as per OEM and all as per IS 4759/ IS 2629 and as directed.
All as item No 17 above but with double bracket complete as per OEM and all as per IS 4759/ IS 2629 and as directed. Note for Item No 17.00 & 18.00 :- (i) The quoted rate shall deemed to include the cost of foundation of pole as designed by OEM. (ii) The DWC HDPE pipe of size 63mm(OD)x 50mm(ID) shall be placed in pole foundation diagonally for passing the cables as specified and directed. DWC pipe shall be measured and paid separately under relevant item.
S & F LED Street lights of cap 60 watt aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection alongwith 10Kv SPD including taking down the old unsv light fitting of any type. complete all as specified and directed.
Supply, laying, testing and commissioning of underground LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 2x6 sqmm (laid in trenches,ducts,pole,wall etc.) incl taking down old unsv cable complete all as specified and directed.
All as per above item No. 23 here in before but cable size 4x16 sqmm. complete all as specified and directed.
All as per above item No.23 here in before but cable size 4x25 sqmm. complete all as specified and directed.
M&L for cutting the road/ footpath/ hard standing etc for laying of pipe complete all as specified and directed.
S&F FRP pole box 140x140x95 mm (inside dimension) consisting of 1 No of 50 A 4 pole connector and 1 No 6 A MCB SP including taking down the old/unserviceable junction boxes complete all as specified and directed.
S&F FRP pole box 240x130x95 mm (inside dimension) consisting of 1 No 50 A 4 pole connector and 1 No 6-16 A MCB SP(as required) including taking down the old/unserviceable junction boxes all as specified and directed.
S&F LED flood light made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection of cap 150 Watt ,220V 50Hz supply, pressure Die cast aluminium housing and IP 66 Class-I protection, System efficacy ≥ 110/120LPW 10KV SPD included, to be fixed on pole mounted iron frame or bracket including removing of the old unserviceable halogen/any type of light fittings complete all as specified and directed.
All as per Item No 26 hereinbefore but for capacity 135 Watts complete all as specified and directed.
S & F of LED floodlight 70 watt, made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. System efficacy ≥ 110/120LPW, 10KV SPD included, ,220V 50Hz supply , to be fixed on pole mounted iron frame or bracket including removing of the old unserviceable halogen/any type of light fittings complete all as specified and directed.
M&L in repair for twin core 4 Sqmm stranded aluminum conductor, PVC sheathed and PVC insulated from light fitting to loop-in/ loop-out box including 15mm dia non-metallic rigid PVC conduit medium grade with conduit accessories fixed with saddles along the pole including taking out old unserviceable conductor complete all as specified and directed.
Supply and fixing of outdoor type Decorative Post top for 360° indirect light with IP 65 protection, resistant to impact and corrosion of 240V,50Hz of capacity 40 watt LED suitable for mounting on 60 mm OD pipe on necessasry PCC works complete all as specified and directed.
M&L in repair for 40 mm dia or bore galvanised steel tubing, medium grade, with all fittings and fixed to walls/ poles or laid in floors complete as in protection of cables complete all as specified and directed.
M&L in replacement of 50 mm dia or bore galvanised steel tubing, medium grade, with all fittings and fixed to walls/ poles or laid in floors complete as in protection of complete all as specified and directed.
M&L in repair for street light mounting bracket made up of 32 mm dia galvanised steel tubing, medium grade, 1.20 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of flat iron of size 50x6 mm, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Taking down old timer panel and supply and fixing of out door type Street light timer Panel/Distribution Boards with pole, panel etc as directed alongwith 65A 3 pole/230 Volts contactor and Digital 24 hrs/ Analog Time Switch, 63 A MCB, Manual and Auto Mode Toggle switch cable connectors, cable gland etc including suitable fixing arrangement with Angle iron structure duly embeded with PCC suitable complete all as specified and directed. Note:- Angle iron and PCC work will be paid and measured under relevant items as separately
Supply and fixing Cross Arms, bracings, supports, clamps, eye hook etc structural steel sections including pole clamps stay clamps, D clamps nuts, bolts, washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed
Earthing complete with galvanised earth plate electrode 60 cm x 60 cm x 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth wire 4 MM Dia as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. Including taking down old unserviceable.
Supply & fix in replacement of Cable Junction Box of size 130x180x77mm, IP 66 (Grey) with integrated membranes/metric knockouts for cable entry of size upto 10.00 sqmm twin core with earth, Lightening Outgoing cable: 3C x 1.5/ 2.5 Sq.mm cable, Degree of protection: IP66, Lighting MCB Rating: 10A,SP, B-Curve, current carrying capacity: 40A, Material: PC-GFS (polycarbonate) , Weatherproof, resistant to weather influences including taking down the old/unserviceable junction boxes all as specified and directed.
Supply & fix in replacement of Cable Junction Box of size 155x210x92mm, IP 66 (Grey) with integrated membranes / metric knockouts for cable entry of size upto 25 sqmm twin core with earth, Lighting Outgoing cable: 3C x 1.5/ 2.5 Sq.mm cable, Degree of protection: IP66, Lighting MCB Rating: 10A,SP, B-Curve, current carrying capacity: 40A, Material: PC-GFS (polycarbonate) , Weatherproof, resistant to weather influences including taking down the old/unserviceable junction boxes complete all as specified and directed.
S & F in replacement of PVC Insulated and PVC Round Sheathed 3 core 1.0 sqmm Bright Annealed Bare Copper Conductor Heavy Duty Flexible Cables for Voltage Grade 1100 Volts for connection of lights from junction box complete all as specified and directed.
BHARAT MULTITECH INDUSTRIES PVT LTD (BID ID -3261779)
Prasur Electricals & Engineering Co. (BID ID -3262639)
AMR TRADERS (BID ID -3262704)
Gulmarg Electrical Service (BID ID -3262666)
M/S ISLAND REALCON INDIA PVT. LTD (BID ID -3262280)
Tropical Refrigeration (BID ID -3268098)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .